| 1 | L1₹7.8 LAccepted-AOC 21 KISHORE BHAWAN MALVIYA NAGAR AIR FORCE JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.2 L+₹4.3 L (54.6%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
7 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LAB JODHPUR
REPAIR AND MAINT OF STREET /SECURITY LIGHTS, GARDEN LIGHTS, POST TOP LANTERN AND OTHER RELATED WORKS AT DEFENCE LAB JODHPUR
2024_MES_673107_1
8610/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹19,000
Yes
7 Dec 2024
9 Sept 2024
9 Oct 2024
9 Sept 2024
7 Oct 2024
18 Sept 2024
10 Sept 2024 - 17 Sept 2024
Amount
Replacing wires / jumpers on street light poles as required for proper functioning of street light fittings complete all as specified and directed by engineer-in-charge.
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp including suitable size of wire of any length for all necessary connections including taking down old UNSV light complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED flood light 300 watt 230 V AC outdoor type, made up of pressure die cast aluminium housing with toughended glass, high power LED and secondary lenses with IP66 protection, NB/MB/WB, 10 KV SPD, system efficacy not less than 120/135 LPW including suitable size of wire of any length for all necessary connections, taking down old UNSV light including necessary foundation with plaster any size if required complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type made up of pressure die cast aluminium housing with toughended glass, high power LED and secondary lenses with IP66 protection, 10 KV SPD, system efficacy not less than 110/120 LPW including suitable size of wire of any length for all necessary connections including taking down old UNSV light complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type made up of pressure die cast aluminium housing with toughended glass, high power LED and secondary lenses with IP66 protection, 10 KV SPD, system efficacy not less than 110/120 LPW including suitable size of wire of any length for all necessary connections including taking down old UNSV light complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED bollard light fitting 10/12 Watt 230 V AC outdoor type made up of pressure die cast powder coated housing with PC diffuser, 360 degree light distribution with IP65 protection including suitable size of wire of any length for all necessary connections including necessary mounting arrangement including taking down old UNSV light complete all as specified and as directed by Engineer-in-charge.
S&F Driver for LED 60-300 Watt as per existing make complete all as specified and directed by Engineer-in-charge.
S&F Surge peotection device for LED 60-300 Watt as per existing make complete all as specified and directed by Engineer-in-charge.
S&F in repair FRP junction box of size minimum 620x330x240 mm dimension,off white color,door fixed with hinge on left side ,inlcuding 4 Nos vertical aluminium bus bar and 10 amp MCB for connection to the cable including taking down old UNSV junction box complete all as specified and as directed by engineer-in-charge.
S&F MCB SP ‘C’ curve, 10KA 6-32 amps including necessary connection including taking down existing unserviceable MCB from Junction box including taking down old UNSV MCB complete all as specified and directed by Engineer in charge.
S&F MCB SP ‘C’ curve, 10KA 40-63 amps including necessary connection including taking down existing unserviceable MCB from Junction box including taking down old UNSV MCB complete all as specified and directed by Engineer in charge.
S&F MCB SPN ‘C’ curve, 10KA 40-63 amps including necessary connection including taking down existing unserviceable MCB from Junction box including taking down old UNSV MCB complete all as specified and directed by Engineer in charge.
Supply, laying, jointing and testing 2.50 sqmm PVC insulated,unsheathed,multi-stranded,3 core,FRLS copper conductor cable for connection of security light to junction box or over head conductor including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-charge.
S&F in repair rigid non metalic PVC conduit (ISI Mark) of external dia 25mm with fixing accessories such as couplers,saddles,nuts,clamps etc all as required at site, complete all as specified and as directed by Engineer-in-charge. Note :- The cost of Clamps, nut bolts etc shall be included in the rate quoted.
Supply & fixing MCB TP 63 Amps 240 volt complete all as specified and directed by Engr- in charge
Supply & fixing in replacement LED bulb of 9 watt, 6500 K complete all as specified and directed by Engr- in charge
Supply and Fixing ,nature switch(using infrared sensor technology) based automatic street light panel. The sensor aloghwith suitable 3 nos Power contactors, 3 Nos incoming and 3 Nos outgoing MCBs each 63 Amp and circuit wiring minium 16 sqmm copper wire should be enclosed in a pole/wall mounted rust proof, electric shock proof termite proof and FR grade SMC enclosure confirming to IP 66. The circuit should also have the provision of manual operation(sensor by-pass operation). The sensor should have also part night operation facility of min 4 hrs to max max 12 hrs complete all as specified and as directed by Engineer-in-charge. Make- Swadeep Model - Swadeep- 02EC-25kw3p or equivalent
S&F 10 sqmm 2 Core aluminium cable (TC) heavy duty complete all as specified and as directed by Engineer-in-charge.
S&F in repair street light brackets made out of 40mm dia light grade GI tubing, bent to shape length not less than 1.20 metre fixed with suitable size of clamps, nuts, bolts etc all as required at site, complete all as specified and as directed by engineer-in-charge. Note :- The cost of Clamps, nut bolts etc shall be included in the rate quoted.
Supply & fix all-in-one solar street light 60 watt, with high efficiency monocrystalline PV module, LiFe PO4 battery with inbuilt BMS tecnology, MPPT charge controller, aluminium extruded body IP 65 with sericeable battery compartment, high efficacy LED not less than 150 LPW, water proof including necessary fixing arrangement on existing pole complete all as specified and directed by Engr- in charge
M&L in replacement MCCB 4 pole 100 Amps, 36 KA 415 Volts , electronic/ micro processor release type including necessary connection including taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge.
M&L in replacement MCCB 4 pole 160 Amps, 36 KA 415 Volts , electronic/ micro processor release type including necessary connection including taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge.
M&L in replacement MCCB 4 pole 200 Amps, 36 KA 415 Volts , electronic/ micro processor release type including necessary connection including taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge.
M&L in replacement MCCB 4 pole 250 Amps, 36 KA 415 Volts , electronic/ micro processor release type including necessary connection including taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge.
M&L in replacement MCCB 4 pole 400 Amps, 36 KA 415 Volts , electronic/ micro processor release type including necessary connection including taking down existing unserviceable MCCB complete all as specified and directed by Engineer-in-charge.
M&L for cable jointing kit for 440 volt grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm complete all as specified and directed by Engineer-in-charge.
M&L for triming of tree branches (tree prunning) of any girth/dia to clear the distance minimum 5 mtr radius of the street light by using JCB, Hydra,Crane including removing the cut branches from site and depositing at any places all as directed by Engineer-in-charge.
M&L for triming of tree branches (tree prunning) of any girth/dia to clear the route of LT over head lines around the 3 Mtr from the external conductors by using JCB, Hydra Crane including removing the cut branches from site and depositing at any places all as directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable withaluminium conductor, 1100 volts grade, cross area 25 sqmm 4 core including suitable size lugs and glands etc as required complete all as specified and as directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable withaluminium conductor, 1100 volts grade, cross area 35 sqmm 3.5 core including suitable size lugs and glands etc as required complete all as specified and as directed by Engineer-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed by Engineer-in-charge.
M& L for spreading clean dry sand(tibba sand) in trenches for cushioning to UG LT cable and punning to provide required cover to UG cable complete all as specified and directed by Engineer-in-charge. Note :- Punned thickness shall be measured for the purpose of payment.
Supply and laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti for cable cover 25 cm to 30 cm wide and not excedding 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated materials to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-charge.
Note:- Schedule of credit as per availabilty at site, Contractor will not claim for the same during execution of work.
vinayandsons (BID ID -3130549)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .