Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹22.9 L+₹30,667.76 (1.36%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹23.0 L+₹41,584.76 (1.84%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹23.5 L+₹91,330.76 (4.05%)Rejected-Finance DOOR NO 44 19 10 RAILWAY NEW COLONY BEHIND SIVALAYAM VISAKHAPATNAM AP 530016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹23.7 L+₹1.2 L (5.13%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹39.9 L
EMD Value
₹79,760
Closing Date
3 Nov 2022, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR /MAINT TO STREET / SECURITY LIGHTS, PERIPHERY LIGHTS, POST TOP LANTERNS, HIGH MASTS LIGHTS, GARDEN LIGHTS, LT FEEDER PILLAR BOXES, LT UG CABLES AND CONNECTED WORKS OF LT DISTRIBUTION SYSTEM AT INS EKSILA UNDER AGE E/M NO-II OF GE(U-I)(V)
2022_MES_557553_1
8478/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
Class D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹79,760
Yes
19 Nov 2022
13 Oct 2022
4 Nov 2022
13 Oct 2022
3 Nov 2022
27 Oct 2022
Amount
Excavation in trenches n.exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil all as directed.
Returning and filling in of excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each.
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection . Make : Tata / Jindal Steel / Prakash / Surya Roshini
M&L for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection . Make : Tata / Jindal Steel / Prakash / Surya Roshini
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable all as directed.
M&L for PCC type C2, 1:3:6 using (40 mm gradded stone aggregate) in foundations complete all as specified &directed.
M&L for PCC type B-1, 1:2:4 using (20 mm gradded stone aggregate) for coping, including form work complete all as specified & directed.
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade XLPE , armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. Make : Havells / Gloster / Polycab / KEI Industries Ltd / Asian Cable / Finolex
25 Sqmm 4 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
400 Sqmm 3.5 core
10 Sqmm 2 Core
16 Sqmm 4 core
10 Sqmm 4 core
Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps. Make: C&S / Schneider / L&T / Indoasian / GE / Havells
Supply and fix in repairs MCCBs of following current carrying capacity. Make: HPL / C&S / Schneider / L&T / Indoasian / GE / Havells
(a) 3 Pole MCCB 400 Amps, Adjustable type,415V, 36KA rating
(b) 3 Pole MCCB 250 Amps, Adjustable type, 415 V, 36KA rating
(c) 3 Pole MCCB 200 Amps, Adjustable type, 415 V, 36KA rating
(d) 3 Pole MCCB 160 Amps, Adjustable type, 415 V, 36KA rating
(e) 3 Pole MCCB 125 Amps, Adjustable type, 415 V, 16KA rating
(f) 3 Pole MCCB 100 Amps, Adjustable type, 415 V, 16KA rating
(g) 4 Pole MCCB 400 Amps, 415 V, Microprocessor release breaking capacity 36 KA
(h) 4 Pole MCCB 250 Amps, 415 V, Microprocessor release breaking capacity 36 KA
(j) 4 Pole MCCB 200Amps, 415 V, Adjustable type with breaking capacity 36 KA
(k) 4 Pole MCCB 160 Amps, 415 V, Microprocessor release with breaking capacity 36 KA, 160 A rated
(l) 4 Pole MCCB160 Amps , 415 V, Adjustable type with breaking capacity 36 KA
Supply and fix in repairs Isolator 415 Volts of following current carrying capacity. Make: HPL / C&S / Schneider / L&T / Indoasian / GE / Havells
(a) 4 Pole 63 Amps
(b) 4 Pole 100 Amps
(c) TPN 63 Amps
(d) TPN 100 Amps
M&L for detecting LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable indentification instrument , cable tracer for exact location of under ground cable routes.
Note: The rate quoted deemed to be inclusive of transportation of equipment and charges for service engineer . Note : The fault locator will be arranged by Contractor Only
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm. Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM / Denson
All as per Item No.15 herein before but for cable of size 3.5 core 95 to 120 sq.mm.
All as per Item No. 15 herein before but for cable of size 3.5 core 150 to 185 sq.mm.
All as per Item No. 15 herein before but for cable of size 3.5 core 240 to 300 sq.mm.
M&L for heat shrinkable Termination Kit (with colour limbs of Red, Yelllow, Blue & Black) for LT UG cable for making serviceable for aluminium conductor cable of size 3.5/ 4 core 50 to 95 sq.mm. Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM / Denson
All as per Item No.19 herein before but for cable of size 3.5 core 120 to 185 sq.mm.
All as per Item No.19 herein before but for cable of size 3.5 core 240 to 300 sq.mm.
Disconnecting, dismantling of existing feeder pannel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement, two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including horizontal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in : - (a) Incomming: MCCB high breaking capacity 4 pole 415 volt 35 KA breaking cap adjustable thermal release range 100 amp -01 No (b) Outgoing: (i) MCCB high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 63 amp of – 07 No (ii) Multifunction Meter, Phase indicator (R, Y & B) Make : C&S / Schneider / L&T / Indoasian / GE / Hevalls
Cuting of trees / bushes in surrounding of LT Panels of any size and complete cleaning of grass upto 1.5 mtr radius area around the panel area.
Excavation of cable size 70 Sqmm to 300 Sqmm from its loop, cleaning, cutting of old termination kit and refix with suitable lugs alongwith refilling of cable with existing sand and bricks.
M&L in repair for earthing with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 25 x 4mm by means of bolts, nuts, check nuts & washers of galvanished iron or steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),
"mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering and 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' of SSR and connected to earthing test point all as specified and indicated including testing on completion complete all specified and directed by Engineer-in-Charge.
M&L for Maintenance and attending complaints / breakdowns at INS Eksila area comprising of LT panels, over head lines/ underground LT cables upto main distribution boards at buildings including repairs of day to day maintenance of LT panels/Perimeter lights for smooth & trouble free LT power supply as directed by Engr-In-charge including rectification of minor defects to electrical controls gear/accessories.
Note :- The rate quoted is inclusive for the following :- (i) (a) Attending minor repairs/breakdowns without involving any new (major) materials. (b) Cost includes the tools for attending break down and minor materials like lugs and PVC tapes,Job Cards and Complaint registers etc. (c) Major repairs,Break downs involving S&F of materials such as cables,Joints,MCCBs etc are out side the scope of this item and shall be measured and paid separately. (ii) Contractor should ensure to carry out the work through qualified Technician/Electrician and assisted by the helper. Necessary tools & plants and transportation charges are deemed to be included in the unit rate quoted.
Supply and fix in replacement Electronic Timer suitable for street light timer panel/DG AMF panel/ Star Delta Starter panel . Make: L&T / Indoasian / GE / BCH / HPL
Supply and fix in replacement 3/4 Pole Contactor suitable for street light timer panel/DG AMF panel. Make: L&T / Indoasian / GE / BCH / HPL / C&S / ABB / Siemens
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note: a) The M/L for Items like electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items herein under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site. d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
Supply only the following spares suitable for street light/food light/post top lantern light fittings of
Electronic driver suitable for 120 to 150 W LED light fitting
Electronic driver suitable for 90 to 100 W LED light fitting
Electronic driver suitable for 70 to 80 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Dismantling LED light fitting of capacity 120 to 150 W ,strip opening the electronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs including soldering, replacement of pitted control wiring from LED panel to driver etc, including testing and commissioning complete all specified and directed by Engineer-in-Charge. Make: GE/Havells/CG/ Goldwyn/Bajaj /Philips /Surya Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items.
Dismantling LED light fitting of capacity 90 to 100 W ,strip opening the electronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs including soldering, replacement of pitted control wiring from LED panel to driver etc, including testing and commissioning complete all specified and directed by Engineer-in-Charge. Make: GE/Havells/CG/ Goldwyn/Bajaj /Philips /Surya Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of capacity 70 to 80 W ,strip opening the electronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs including soldering, replacement of pitted control wiring from LED panel to driver etc, including testing and commissioning complete all specified and directed by Engineer-in-Charge. Make: GE/Havells/CG/ Goldwyn/Bajaj /Philips /Surya Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items.
Taking down old unserviceable street light fittings from any height and Supply & fixing 60 Watt LED street light fittings comprising of epoxy powder coated housing, enclosed with cover in frame, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc and testing on completion all as specified and as directed. Make: Havells /Philips/ Bajaj/GoldMedal / CG Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable street light fittings from any height and Supply & fixing 90 Watt LED street light fittings comprising of epoxy powder coated housing, enclosed with cover in frame, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc and testing on completion all as specified and as directed. Make: Havells /Philips/ Bajaj/Goldmedal/CG Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable street light fittings from any height and Supply & fixing 100 Watt LED street light fittings comprising of epoxy powder coated housing, enclosed with cover in frame, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc and testing on completion all as specified and as directed. Make: Havells / Philips/Bajaj /Goldmedal /CG Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable street light fittings from any height and Supply & fixing 120 Watt LED street light fittings comprising of epoxy powder coated housing, enclosed with cover in frame, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc and testing on completion all as specified and as directed. Make: Havells /Philips/BAJAJ/Goldmedal/CG Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Dismantling old unserviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing 120 Watt LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type with ingress protection IP 65 and surge protection device of 10 KV capacity etc including necessary angle iron supports , clamps etc complete and testing on completion all as specified and as directed Make: Havells/Philips/Bajaj/Wipro/ Goldmedal/CG
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing 150-170 Watt LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc and testing on completion all as specified and as directed. Make: Havells / Philips / Bajaj /Wipro /GE / Goldmedal / CG
Taking down old unserviceable post top lantern fittings and Supply & fixing post top luminarie LED type of 40 W with IP 65 protection with die cast aluminium graphite grey powder coated finished body , polycarbonate opal diffuser, low power warm white (WW) LEDs with better heat dissipation, high efficient constant current electronic driver having operating voltage range from 140 to 280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 10 KV etc complete suitable for 60 mm OD pipe entry including suitable size loop in loop out boxes & flexible 3 core 1.5 Sqmm copper connecting cable from loop in loop out box to fitting etc complete all as specified & directed. Make: CG /Philips /Bajaj /Wipro /GE /Havells/ Goldmedal Note: The GI pipe if required will be measured and paid separately under relevant schedule items
Supply and erection, testing and commissioning of steel tubular swaged poles type 410 SP- 31 (9 meter long) complete with CI base plate,, finial taper plug, bolts, nuts & screws complete all as directed.
S&F in repair PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting testing and commissioning all as directed. Make: Havells / Gloster / Polycab / KEI Industries Ltd / Asian Cable / Finolex
Supply and fixing timelite distribution boards (street light DBs) 65 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one . Make: Indo Asian/ HPL/Havells
S&F loop-in/loop-out box of internal size 250 x 200 x 100 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc in the box, duly fixed to to steel tubular pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as specified & directed by Engineer-in-Charge. Make : National / Sintex / Hensal / HPL
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI pipe bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective. Make : Tata / Jindal Steel / Prakash / Surya Roshini
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ blackground etc complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of 11 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ blackground etc complete all as directed
M&L for fixing in repair adhesive sticker radium tape red coloured water resistant of approx 2 inches width around the circumference of pole at a approx height of two meters all as directed.
Excavation in trenches as in soil not exceeding 1.5mtr wide, exceeding 1.5mtr depth but not exceeding 3mtr complete all as specified & directed by Engineer-in-Charge.
VENKATESWARA ENGINEERS AND CONTRACTORS
AARAV POWER CONTROLS
ANJALI ENTERPRISES
SRIESWARI ENTERPRISES
GS ENGINEERS
DELTA CONSTRUCTIONS
MONITOR ENGINEERING WORKS
R AND A ASSOCIATES ENGINEERS CONTRACTORS
MSN ENGINEERING WORKS
SUPREET CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .