Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st lowest₹81.5 LAccepted-AOC | 1st lowest | Accepted-AOC 1st lowest Bidder | |
| 2 | 2nd lowest₹88.8 L+₹7.3 L (8.97%)Rejected-Finance | 2nd lowest | Rejected-Finance 2nd Lowest Bidder |
Tender Value
₹90.9 L
EMD Value
₹1.8 L
Closing Date
7 Aug 2023, 5:00 pmClosed
DGM Transmission Division 79 Tilla Agartala
DGM Transmission Division 79 Tilla Agartala 799006
As per Bid Document
2023_POWER_40265_1
DGM/TD/AGT/NIeT/2023-24/02 Dt. 15.07.2023
Open Tender
Electrical Works
Turn-key
120 days
Rokhia Generating Station
As per Bid Document
5 documents required · 5 mandatory
₹10,000
₹1.8 L
DGM Transmission Division 79 Tilla Agartala
7 Nov 2023
21 Jul 2023
8 Aug 2023
22 Jul 2023
7 Aug 2023
29 Jul 2023
24 Jul 2023 - 27 Jul 2023
28 Jul 2023
Amount
GROUP-A (SUPPLY) :
145 KV, 3 pole outdoor class SF6 Circuit Breaker of 2500 A rated normal current and breaking capacity 7500 MVA rated symmetrical breaking current 40 KA with required motor operated spring charge mechanism complete with Galvanized supporting Structure and standard accessories & tools complete with all accessories.
132KV Control relay and meter panel duplex corridor type sheet steel cubicle complete with wiring links fuses internal illumination, ammeter, voltmeter, electronic Multi Functional Meter, combined numerical type directional over current and earth fault IDMTL relay, Distance protection relay, auxiliary relay, master trip relay, LBB relay, semaphore, mimic bus diagram etc. for Feeder protection and control.
Retrofitting of following Numerical Relay at 132KV C.R. Panel of both side of 132KV link line at Rokhia .
a) Back up Earth Fault & Over Current Relay (MICOM-P-141)
b) Supply & Retrofitting of Line Differential Relay (MICOM-P-546) with Fiber approach cable
1.1 KV graded PVC Insulated (sheathed) 2.5 sq.mm Copper (Stranded) armored control cable.
i) 14 core 2.5 Sq.mm Control cable
ii) 10 core 2.5 Sq.mm Control cable
iii) 7 core 2.5 Sq.mm Control cable
iv) 5 core 2.5 Sq.mm Control cable
40 mm Dia, 6 mtr long MS Rod Earthing Electrode
50 x 8 mm GS Flat for equipment and structure earthing for main earth mat and risers
Supply ( DTPC equipment & accessories)
TeleProtection Terminal Equipment 19-Inch, Rack mountable. Network Interfaces: 1 x C37.94 protocol optical interface [with SFP] Substation Interfaces: -upto 8, 2-way independent-simultaneous binary command channels Management: SNMP/Telnet Port (RJ45 (F)), Serial Port (USB, DB-9 COM) Serial Port, EMS, Graphical User Interface (GUI) Installation Kit: System Core Cables, Mounting Hardware,Documentation, User Manual -2 x 48V DC Power Supply Input [Redundant] -Command Voltages : 110-125V DC / 220-250V DC -Command Voltages Set to 220-250V DC Includes: 1 x External Trip Counter Display 1 x External feed-through Terminal Block (TB) 60-I/O 1 x SFP, 13dB, 1310nm, 9.38 miles/15 km, SM (single mode)
24F Single-Mode, FODP, Rack Mount
12 Core Armoured Single-Mode Fiber Cable
Outdoor Joint Box
2 Core (2.5 sq.mm.) Armoured DC Cable
12 Core (2.5 sq.mm.) Armoured Control Cable
IP41 complied 19" Telecom Cabinet [1800 (H) x 600 (W) x 600 (D)]
GROUP "B" (ERECTION / TRANSPORTATION
145 KV, 3 pole outdoor class SF6 Circuit Breaker of 2500 A rated normal current and breaking capacity 7500 MVA rated symmetrical breaking current 40 KA with required motor operated spring charge mechanism complete with Galvanized supporting Structure and standard accessories & tools complete with all accessories.
132KV Control relay and meter panel duplex corridor type sheet steel cubicle complete with wiring links fuses internal illumination, ammeter, voltmeter, electronic Multi Functional Meter, combined numerical type directional over current and earth fault IDMTL relay, Distance protection relay, auxiliary relay, master trip relay, LBB relay, semaphore, mimic bus diagram etc. for Feeder protection and control.
Retrofitting of following Numerical Relay at 132KV C.R. Panel of both side of 132KV link line at Rokhia .
a) Back up Earth Fault & Over Current Relay (MICOM-P-141)
b) Supply & Retrofitting of Line Differential Relay (MICOM-P-546) with Fiber approach cable
1.1 KV graded PVC Insulated (sheathed) 2.5 sq.mm Copper (Stranded) armored control cable.
i) 14 core 2.5 Sq.mm Control cable
ii) 10 core 2.5 Sq.mm Control cable
iii) 7 core 2.5 Sq.mm Control cable
iv) 5 core 2.5 Sq.mm Control cable
40 mm Dia, 6 mtr long MS Rod Earthing Electrode
50 x 8 mm GS Flat for equipment and structure earthing for main earth mat and risers
Transportation of 132 kV single phase out-door type oil cooled wound primary type CT (3 Nos) from P.K Bari Sub-Station to Rokhia GTP including loading & unloading as per direction of Engg -in - Charge.
Transportation of 132 kV single phase out-door type oil cooled wound primary type CT (3 Nos) from Surjamaninagr Sub-Station to Agartala Grid Sub-station, 79 tilla including loading & unloading as per direction of Engg -in - Charge.
Erection of 132 kV single phase out-door type oil cooled wound primary type CT as per direction of Engg -in - Charge.
( DTPC equipment & accessories)
Installation & Commissioning , Retrofeting (DTPC + laying)
GROUP - "C" (DISMANTLING AND HANDING OVER OF MATERIALS)
Dismentling 145 KV, 3 pole outdoor class SF6 Circuit Breaker of 2500 A rated normal current and breaking capacity 7500 MVA rated symmetrical breaking current 40 KA with required motor operated spring charge mechanism complete with Galvanized supporting Structure and standard accessories & tools complete with all accessories.
Dismentling of 132KV Control relay and meter panel duplex corridor type sheet steel cubicle complete with wiring links fuses internal illumination, ammeter, voltmeter, electronic Multi Functional Meter, combined numerical type directional over current and earth fault IDMTL relay, Distance protection relay, auxiliary relay, master trip relay, LBB relay, semaphore, mimic bus diagram etc. for Feeder protection and control.
Dismentling of 132 kV single phase out-door type oil cooled wound primary type CT (3 Nos) from P.K Bari Sub-Station as per direction of Engg -in - Charge.
Dismentling of 132 kV single phase out-door type oil cooled wound primary type CT (3 Nos) from Surjamaninagr Sub-Station as per direction of Engg -in - Charge.
Dismentling Back up Earth Fault & Over Current Relay (MICOM-P-141) from 132 KV CR panel at Rokhia.
M/S Saha Trading
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .