| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 CrAccepted-AOC A 31 RAJENDRA NAGAR BAREILLY UP 243122 | BAREILLY | BAREILLY | UP | 243122 | ₹9.0 Cr Quoted ₹9.1 Cr | L1 | Accepted-AOC Being L1 and reasonable. |
| 2 | L2₹9.5 Cr+₹38.9 L (4.28%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹9.5 Cr+₹38.9 L (4.28%) | L2 | Rejected-Finance Being other than L1. |
| 3 | L3₹10.4 Cr+₹1.3 Cr (14.2%)Rejected-Finance | ₹10.4 Cr+₹1.3 Cr (14.2%) | L3 | Rejected-Finance Being other than L1. |
Tender Value
₹8.5 Cr
EMD Value
₹7.5 L
Closing Date
29 Oct 2021, 6:00 pmClosed
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan, Station Road Bareilly Cantt Bareilly - 243001
ADDN/ALTN CUM SPECIAL REPAIRS TO OFFRS / JCOs / ORs MD ACCN UNDER GE (W) BAREILLY
2021_MES_475194_1
CEBZ/BLY/T-06 OF 2021-22
Open Tender
Civil Works
Item Rate
455 days
Bareilly
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (W) Bareilly
₹7.5 L
Yes
24 Dec 2021
14 Sept 2021
2 Nov 2021
14 Sept 2021
29 Oct 2021
13 Oct 2021
16 Sept 2021 - 6 Oct 2021
Amount
BLDG WORK
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed.
M & L for non-skid ceremic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of tiles and screed bed or bedding layer of mortar 15mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed.
All as per serial item No 3 as above but as in vertical surfaces including dismantling of tiles and rendering 10 mm thick in cement mortar (1:4), as in backing layer complete all as specified and directed.
M & L for non- skid ceremic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of tiles and screed bed or bedding layer of mortar 15mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M & L for non- skid ceremic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of tiles and screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for vitrified Ceramic tiles light shade 10mm thick (square/rectangular) polished, area of each tiles exc 0.16 sqm and not exceeding 0.36 sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement and including provn of 15mm thick screed bed 1:6 cement motar including dismantling of floor tiles and screed bed / rendering and hearthing complete all as specified and directed.
All as per serial item no 7 as above but as in vertical surfaces including dismantling of tiles and screed bed / rendering and provn of rendering 10 mm thick in cement mortar (1:4), as in backing layer complete all as specified and directed.
M&L for glazed (coloured) ceramic tiles wall 300x450x7mm thick on vertical faces of walls including 10mm thick rendering in CM (1:4) set jointed in neat cement slurry and pointed in coloured cement to match including taking down old dado/skirting complete all as specified and directed.
M&L for Providing & injecting chemical for post construction Anti Termite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in a portion with cement mortar (1:2) (1 cement : 2 coarse sand) to match the existing apron complete all as specified and directed. Make : Pidilite (Terminator) / Noban TC / Chloro 20.
M & L for Post Construction anti termite Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor complete all as specified and directed. Make : Pidilite (Terminator) / Noban TC / Chloro 20.
Taking down chowkats with shutters (without taking off shutters from the frames) area not exc 1.5 Sq.m each including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM (1:4) complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) area exc 1.5 Sqm each and not exc. 4.00 Sqm including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM (1:4) complete all as specified and directed.
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete all as specified and as per manufacturer's instructions and as directed. Make : M/s Safety doors LLP Delhi / Jairaj Composite Industries, Gujarat / Century Plywood / Duraplast.
Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified and as per manufacturer's instructions and as directed. Make : M/s Safety doors LLP Delhi / Jairaj Composite Industries, Gujarat / Century Plywood / Duraplast.
S&F 125mmx60mmx2mm thick pressed steel, frames for door with one or more rebates including filling and compaction with PCC (1:3:6) Type C-1 using 20 mm graded stone aggregate, necessary fixing lugs, hinges, lock strike plate, etc, complete including wooden texture finished paint on the frame surface complete all as specified and directed.
S&F 105mmx60mmx2mm thick pressed steel, frames for door with one or more rebates including filling and compaction with PCC (1:3:6) Type C-1 using 20 mm graded stone aggregate, necessary fixing lugs, hinges, lock strike plate, etc, including wooden texture finished paint on the frame surface complete all as specified and directed.
S&F 35 mm thick Factory made flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specified and directed.
M & L for 35mm thick plain framed glazed and skeleton shutter open rebated & prepared to receive glass, gauge etc, without sash bar edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc, of 2nd class hard wood , members of shutters as specified in SSR Part - I Section 8 clause 8.24 (a) fitted to chowkats complete all as specified and directed.
S&F in repairs factory made PVC cupboards frame of the size 75 mm x 40 mm with a wall thicknesss of 5 mm made out of extruded 5mm thick plain/prelam PVC sheet of density 600kg/cum, having bottom width of 50mm and thickness of 10 mm. All four frame lengths reinforced with 15 mm x 15mm M.S.square tubes of 19 quage thickness throughout the frame and mitre cut at two corners adjointed with 2 nos of 15mm long brackets of 10 mm x 10 mm M.S. square tubes. the door frame shall be fixed to the wall using 8/100 long MS screw through the frame by using PVC fastners. A minimum of 4 nos of screws to be provided for each vertical members and minimum of 2 nos of screw to be provided horizontal members etc. complete all as per manufacturer's specification and drawing and as directed. (Make : Rajshree, Supreme, Century)
S&F Factory made PVC cupboards flush type shutter/ shelve of 30 mm thick consisting of frame made out M S tubes of 19 guage thickness and size 19mm x 19 mm for stiles and rails. The inside panels shall consist of 20 mm thick multichamber hollow PVC section of 1mm wall thickness, bonded using solvent cement / cynoacrylate adhesive with 5mm thick plain/prelam PVC sheet, on both sides of inside panels including all four edges of the panels to be sealed with lipping of 10 mm thick and 20 mm wide PVC sheet baton( made by sticking 2nos PVC foam sheet of 5mm thickness using PVC solvent cement adhesive) and shelve will be rest on PVC fillet 18mm thick or on angle 25x25x3mm fixed with screw length equal to width of the shelve complete all as per manufacturer's specification and drawing and as directed. (Make : Rajshree, Supreme, Century)
M&L for bulit in steel cup board with pressed steel frame of size 75mmx 45mmx1.25mm thick with pressed steel shutter 1mm thick godrej pattern fixed to masonary wall by hold fast made out of 25x3mm flat iron including MS hanging rod of 10mm dia with brackte fixed on inner side of one leaf of shutter and on other leaf provision of ms peg set of three pegs including spray incl locking arrangermet painting with two coats of synthetic enamel paint over one coat of red oxide primer all around on steel surface of frame and shutter and making good distubred portion in CM (1:3) or PCC (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and directed.
S&F for 100mm long stainless steel butt hinges complete all as specified and directed.
S&F for 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150mm long aluminum handles, cast type anodised complete all as specified and directed.
S&F for 200mm long aluminum anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring. Fixed in floor complete all as specified and directed.
S&F 300mm long mild steel sliding door bolts plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F for 1.2mm thick aluminium anodised campsule mesh aperture not more than 1 cm fixing with screw in the door for protection of mosquito wire mesh complete all as specified and directed.
S&F galvanised Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire stapels complete all as specified and directed.
S & F 300 mm size, MS ordinary rat tail rod pattern springs including roller and roller plate complete including fixed to wooden and steel chowkats complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed..
M&L for painting to wood and wood based surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated surfaces complete all as specified and directed.
M & L for preparation of old steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for painting to steel surface over 10 cm in width or girth with two coats of synethic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surface complete all as specified and directed.
S&F for 0.71mm thick Aluminium plain sheeting Alloy 31000 H4, STUCCO Embossed finish with fixed with coach screw and Aluminium washer in roof and wall etc. with end laps stitched with 25x6mm G.I. bolts at 20cm apart including dismantling of old sheeting complete all as specified and directed.
S&F in repairs PVC boards 19/20 mm thick any colour as in cabinets incl shelves and shutters, fixed with screws and adhesives as per manufacturers instructions and as directed including piano hinges, magnet catcher, handles etc complete all as specified and directed.
M& L for 125 mm long Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
M & L for Plain Cement Concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in bed blocks for fixing hold fast / concrete filling in chowkhats and similar work etc complete all as specified and directed.
M&L for 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surfaces) in CM (1:4) including taking down old plaster including raking out joints, hacking for key, scrubbing down with water etc., finishing the surface even and fair without using extra cement and necessary scaffolding complete all as specified and directed.
M&L for 15mm thick cement plaster on bricks or concrete new surfaces (on external surfaces) in CM (1:4) finished even and fair without using extra cement and necessary scaffolding complete all as specified and directed.
M&L for 12mm thick cement plaster on bricks or concrete surfaces (on internal surfaces) in CM (1:6) including taking down old plaster including raking out joints, hacking for key, scrubbing down with water etc., finishing the surface even and fair and necessary scaffolding complete all as specified and directed.
M&L for 12mm thick cement plaster on bricks or concrete new surfaces in CM (1:6) finished even and fair without using extra cement and necessary scaffolding complete all as specified and directed.
M & L for rendering 5mm thick on old concrete surfaces of ceiling in CM (1:3) finished including taking down old plaster, finished even and fair without using extra cement and necessary scaffolding complete all as specified and directed.
M & L for rendering 5mm thick on new concrete surfaces of ceiling in cement mortar (1:3) finished even and fair without using extra cement and necessary scaffolding all as spd and directed
M&L for white washing three coats on ceiling surfaces including preparation of newly plastered untreated surfaces and necessary scaffolding all as specified and directed
M&L for applying 2 mm thick layer of wall care putty on wall/ceiling surfaces incl rubbing down the surfaces with sand paper after getting dried all as directed to obtain a smooth & even surface complete all as specified and directed. (Make : JK wall care / Birla putty)
M&L for Preparation of old decorated surfaces and applying three coat of white wash on ceilings surfaces and rubbing down with sand paper to have even and smooth surfaces complete all as specified and directed.
M & L for applying two coat of distemper oil emulsion white or tinted on old decorated wall surface including preparation of surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed.
M & L for applying two coat of distemper oil emulsion white or tinted on newly decorated or undecorated wall surface including preparation of surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed.
M & L applying one coat of cement based paint on old decorated or undecorated wall, roof surface including preparation of surfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified.
M&L for Two coats of cement base paint on new plastered wall surfaces over a coat of primer of any description including preparation of surfaces complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in CM (1:6) complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed.
M & L for cutting chases of hanging chajjas, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of sunshades, shelves, lintels, Chajja ( up to IInd floor) etc making good, cutting out exc 10cm and not exc 40cm girth in RCC chajjas in brick walls complete all as specified and directed.
Demolition of reinforced cement concrete, (other than ground floors), shelves, chajjas, slabs and stair case similar work carefully and matching to adjoining disturbed surfaces complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L form work to edges of concrete rough finished surface flats/ treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed.
Form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete not exceeding 200mm thick,complete all as specified and directed.
M & L for formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified and directed.
M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified and directed.
M & L for formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified and directed.
S&F TMT bars 10 mm dia and over, cut to length, bent to shape required,including cranking and binding with mild steel wire (annealed) not less than 0.9mm dia. complete all as specified and directed.
S&F TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia. complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in slab supported on wall, beams and columuns in floors, roofs, shelves and stair case etc complete all as specified and directed.
M&L for RCC (1:2:4) type B-1 (using 20mm graded stone agg) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified and directed.
M&L for RCC (1:2:4) type B-1 (using 20mm graded stone agg) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20 mm graded stone aggregate as as in chajjas and like complete all as specified and directed.
Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposing the reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical, apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx50 mm (10 mm gauge welded mesh ) & tack , securing with clips / linding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @3% by weight of cement and recron 3 S as per manufacturer instruction cleaning & removing of waste meterial etc as dirply two coat of Dr fixit /pidilite new coat ezee at interval of 8 hours cure for the surfaces complete all as specified and directed.
Demolition of cement concrete (unreinforced) , in any position and paving n.exc. 15 cm thickness( below or above ground level) including tile/ terrazzo floor complete all as specified and directed.
M & L for 75 mm thick plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in plinth protection finished even and fair complete all as specified and directed.
Providing water proofing treatment to RCC sunken slab as specified and directed as under:- (a) Cleaning the existing RCC sunken slab and vertical wall/RCC beam and hacking the surface. (b) 15mm thick plastering over the floor & vertical surface in CM (1:4), mixed with liquid water proofing compound @ 200ml per 50 kg of cement, trowelled to even and smooth finish without using extra cement .(Water proofing compound shall be measured and paid separately). (c ) filling the sunken portion with water for 72 hrs and carrying out the ponding test.(Any leakage /seapage noticed shall be repaired). (d) Applying two coats of elastomaric acrylic water proof coating Make: Dr. Fixit of pidilite or equivalent per sqm in each coat with roller application complete all as specified and directed.. (Note: Each coat of elastomaric acrylic compound requires 6-8hrs to dry up itself second coat shall be applied on getting the first coat completely dried up.) Make : Dr Fixit, Acrylic Polymer, Dobond Hydro build LW
Supply only liquid waterproofing compound complete all as specified and directed. Make : Dr. Fixit / Dura Build / Perma Shield.
M&L for cement concrete type E2 (1:5:10) (using 40 mm graded stone aggregate) as in mass concrete complete all as specified and directed.
S&F 32mm dia GI pipe, medium grade as in spout pipe in sunken floor complete all as specified and directed.
M&L for PCC (1:2:4) Type B0 using 12.5 mm graded stone aggregate as in levelling course, haunching, coping and similar works of over RCC roof surface including rounded or chamferred on edges etc complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of concrete roof surfaces in CM (1:4) with water proofing compound at the rate of 3kg/ 50kg bag of cement concrete surface complete all as specified and directed. (NOTE:- WPC shall be measured and paid separatly)
Dismantling of roof terracing cement mortar / brick padding / concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material outside of MOD land complete all as specified and directed.
M&L for 25mm thick plain cement concrete type B1 (1:2:4) using 20mm graded stone aggregate in floor finishes even and fair to receive floor tiles complete all as specified and directed.
Supply and providing water proofing treatment with polymeric standard water proofing membrane, Aquaflex manufactured by M/s Bengal Bitumen,MULTIPLAS STANDARD, manufactured by STP TEXAS Ltd/Hyperplas manufactured by IWL Ltd having 10 years guarantee for water tightness complete all as specified and directed and described as under :-
(a) Prepartion of RCC roof surface by wire brushing and cleaning top surfaces including flashings and junctions of parapets etc., and applying one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/Sqm, complete all as per manufacture's specification and as directed.
(b) Supply & providing water proofing treatment with polymeric proofing membrane of 3 Kg/Sqm HYPERPLAS STANDARD/MULTIPLAS STANDARD consisting of 100 micron HMHDPE film centre core including coating the surface with the compatible primer and torch application of membrane with 10 cm overlaps as required thereof, complete all as specified or as directed.
M & L for cement concrete tiles 250 x 250 x 22 mm thick, machine pressed, fixed with neat cement slurry and joint filled with sealing compound over and including 15mm thick screed bed in cement mortar (1:4) on roof top complete all as specified and directed.
M&L for 18-20 mm thick Granite (of any type) tile work machine cut, bedded and jointed with grey cement slurry (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. stone including grinding and polishing and 15mm screed bed in cement mortar 1:6 including dismantling of tiles, hearth etc complete all as specified and directed.
M&L for Granite (of any type) tiles 18-20 mm, thick machine cut and machine, polished,and moulding, as in window cills, riser of steps and urinal partition wash basin platforms and flooring, skirting/ dados like in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of marble laid over cement screed and jointed with grey cement slurry mixed with pigment to match including rubbing & mirror polishing and including 10mm thick cement plaster on brick surfaces or concrete surface in cm (1:4) finished even and rough as screed and dismantling of wall tile including cement mortar bedding complete all as specified and directed.
M & L for 20-25 mm thick machine cut pre polished kota stone slab flooring laid under stairs soffit area and jointed with grey cement slurry fixed with pigment to match to shade of the slab including rubbing and mirror polishing over and including 20 mm thick bedding layer of cement mortar (1:6) for laying floor finishes even and rough with and including dismantling floor, hearth or wall kota stone slab including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M&L for 20-25 mm thick machine cut pre polished kota stone slab in riser of steps skirting, dado and pillar,landing in single piece with round nosing with three numbers of serration using as front door steps, laid over cement screed and jointed with grey cement slurry mixed with pigment to match including rubbing & mirror polishing and inclucding 10mm thick cement plaster on brick surfaces or concrete surface in cm (1:4) finished even and rough as screed dismantling of wall tile including cement mortar bedding complete all as specified and directed.
S&F 18-20 mm thick green marble (of any type) work (table rubbed and polished) in riser & steps, and like jointed in grey cement slurry and including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed and making V-groove 5mm wide and 5mm deep in 3 nos on the tread in length wise 25mm centre to centre complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
S&F in repairs Vitreous china wash down water closet (pedestal pattern) with seamless flushing cistern square design duroplast slim seat cover, slow falling seat cover size 69x37x77 cm, including connection to drain pipe etc complete all as specified and directed.
S&F in repairs Vitreous China water closet squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) and connections to flushing cistern/pipe complete all as specified and directed.
S&F in repair 10 ltrs capacity (PVC), valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. (Model Sleek fresh dual push of hindware model No Postal size 47.6 cm x 15.5 cm x 32 cm Parryware cat no 8177, Cera cat no B1810110 Fitting snow white.)
S&F in repair CP stop valve/angle cock two/one way 15mm dia, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed complete all as specified and directed. (Model ARI 39053 of Jaquar hindware model No F320006, Parryware model No G4907A1)
S&F in repairs chromium plated fancy type concealed stop cock for 15 mm bore pipe complete all as specified and directed. (Model No 8118120 Prayag, ARI-39227 Jaquar, Cera - F1012751, F-4060102)
S&F in repairs chromium plated fancy type long body bib taps with cast copper alloy screwed down, screwed for iron pipe or for brass ferrule for 15 mm bore pipe complete all as specified and directed. (Model No CON - 107KN Make - Jaquar, 9008 - Prayag, F-3002152-Cera)
S&F fancy Bib tap 15mm dia cast copper alloy chromium plated with crutch or butter fly handle screwed down (Pressed for iron pipe) fixed in repairs complete all as specified and directed. (Model No Cera F-3002151, Prayag-8706, Jaquar-CON-047KN)
S&F in repairs 450mm long PVC connection 15mm bore with PTMT nuts complete all as specified and directed.
Taking up or down 15 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Refixing 15mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
Refixing 20mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
S&F for 15mm bore galvanised steel water tubing with all fittings 'medium grade' and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F for 20mm bore galvanised steel water tubing with all fittings 'medium grade' and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F in repairs 1 mm think stainless steel kitchen sink without drainage board of overall size 495x420mm and bowl size 410x330x160mm with lugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and directed. (Make : Cera / Parryware / Kaff)
S&F stainless steel kitchen sink with double bowl with drain board made of stainless steel 1 mm thick with plugs washers and waste pipe and coupling including bedding in cement mortar on dwarf walls including brackets and connecting union to pipe overall size of sink 1372x457 mm and bowl size 405x355 mm complete all as specified and directed. (Make : Cera / Parryware / Kaff)
S&F in repairs 75 mm x 32 mm dia chromium plated waste fitting special size suitable for stainless steel sinks including PVC flexible waste pipe of approved quality complete all as specified and directed.
S&F in repairs 100 mm x 100 mm stainless steel grating fixed in repairs complete all as specified and directed.
S&F in repairs towel rail cast copper alloy, chromium plated 600mm long with bracket in repair complete all as specified and directed.
S & F stainless steel plate rack not less than 5 Kg of size 31"X36"X10" complete all as specified and directed. (Make :- Silvershine SSK-135, BSKPR-315 bluestar)
S&F in repairs vitreous chinaware coloured wash hand basin with pedestal of size 55X40X82cm complete including CP Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed. (Make : WHB - Cat No 10072, Pedestal- Cat No. Ped 11029 Neptune of Hindware ,Parryware Cat No C0480 (SP) 181/CTH ,C 0375 pedestral, Cera Cat No 2090107Ped , Cat No S 2040112 WHB)
S&F in repairs vitreous chinaware coloured wash hand basin without pedastal of size 55X40X82cm complete including CP Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed. (Make : WHB - Cat No 10072 Neptune of Hindware, Parryware Cat No C0480 (SP) 181/CTH, Cera Cat No S 2040112 WHB)
S & F in repair chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union size 125 mm complete all as specifed and directed. (Make: F 7010305 of Cera, Hindware Model No F160006 , Parryware Model No T9985 A1 complete all as specified and directed)
S&F in repairs brass chromium plated wall mixer 2 in 1, 15mm for mixing hot & cold water screwed down three joints to steel pipes or union & plugging and screwed to wall complete all as specified and directed. (Model No - Cat No FUS29281 Fusion of Jaquar, F-390022 Hindware, G0216A1 Parryware)
S&F fancy type 15 mm dia chromium plated wall mixer 2 in 1, hot & cold with long swan for kitchen sink fixing and connections to pipes complete all as specified and directed.
S&F 15 mm dia brass CP health faucet with 1.0 mtr long and flexible PVC tube and wall hook screwed for iron pipe fancy type long body and hanging arrangement complete all as specified and directed. Model No - ALD573 of Jaquar, Hindware F160002, Parryware T9961A1.
S&F in repairs of PVC corner set of three of size (12'X12" ,9"X9" and 6" X6" ) with railling and complete all as specified and directed.
S&F in repairs centre hole basin mixer 15 mm dia chromium plated complete all as specified and directed.
S&F centre hole basin mixer 15 mm dia chromium plated complete all as specified and directed.
S&F low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls complete all as specified and directed.
S&F in repairs Mild Steel PVC coated Curtain Rod of 25 mm dia 1.8mm thick of approved quality with two number decorative design 3 mm thick brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod complete all as specified and as directed.
S&F in repairs stainless steel Curtain Rod 25 mm dia, 1.8mm thick of approved quality with two number decorative design 3 mm thick brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod complete all as specified and directed.
Dismantling water tanks and removing to store capacity exc 250 and not exc. 500 litres complete all as specified and directed.
Dismantling water tanks and removing to store capacity exc 500 and not exc.1000 litres complete all as specified and directed.
S & F 500 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and complete all as specified and directed. Make : Sintex pure / Vectus cool / Supreme smart.
S&F Rotational moulded polyethylene triple layered water storage tanks of 1000 Litre capacity white in colour (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I and complete all as specified and directed. Make : Sintex pure / Vectus cool / Supreme smart.
M&L for disconnection existing tanks, exc 250 ltr & n.exc 500 ltr setting aside (or lowering if required) for repairs, cleaning,etc and hoisting if required reconnection and re-fixing in position. (cleaning repairing, etc measured separately) complete all as specified and directed.
M&L disconnection existing tanks,Exc 500 & n exc 1000 setting aside (or lowering if required) for repairs, cleaning,etc and hoisting if required reconnection and re-fixing in position. (cleaning repairing, etc measured separately) complete all as specified and directed.
S&F 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete all as specified and directed.
S&F in repairs of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F Mild steel casing for Over head tanks, bands, straps, supports or stay, for rain water, ventilating pipes including bolts if reqd, hooks (stay) heavy for large gates hook and pintle large hasps and staple, chains hand made sliding bolts clamps, hold fasts wall ties etc hooks for hanging fans plain angle cleats for securing purlins to wood truss or rafter, knee piece inserts, two way and three way straps, plate washer and similar small articles confirming to Fe-290 Gde - E-165 complete all as specified and directed.
Taking up or down AC/PVC rain water pipe, soil/waste/vent pipe of any size with fittings etc complete all as specified and directed.
S & F PVC (SWR) 110 mm dia soil waste or rainwater drainage pipes single socketed in any length with rubber ring joint laid in floor or fixed on wall complete all as specified and directed.
S & F PVC (SWR) 110 mm bore bends complete all as specified and directed.
M & L 75 mm dia cast Iron Nahani trap with CP grating including jointing to waste pipe fixed in plain cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate complete all as specified and directed. (Make : Dharam Engineering, Hetech Metal casting Pvt Ltd, Dipra Enterprise)
S&F 100mm bore CI soil waste / vent pipe (spun type) in any length with or without ears with cement joint to wall with stack clamps out of 110mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing end of stays to wall or roof etc.all as specified including black japan paints complete all as specified and directed.
S & F spun iron soil, waste and vent pipe, 75mm bore, in any length with or without ear with cement joint fixed to walls complete all as specified and directed.
S&F in repairs CI 100mm bore Y-Junction piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed.
S&F CI 100mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed.
S&F CI 75 mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed.
S&F 100mm bore CI bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door complete all as specified and directed.
S&F 80mm bore CI bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door complete all as specified and directed.
S&F in repairs 80 mm bore CI cowl complete all as specified and directed.
M&L for run lead joint for 100mm bore for branch piece/soil waste pipe/ vent pipe etc complete all as specified.
M&L for run lead joint for 80mm bore branch piece/soil waste pipe/ vent pipe etc complete all as specified.
S&F powder coated aluminium frame for windows, ventilators and kitchen cupboards frame size 100x44mm and 2mm thick with one or more rebates including joining cleat for fixing etc and add for powder coating (minimum thickness of powder coating 50 micron) complete all as specified. Make : Jindal / Hindalco / Indalco. Note : 1. Weight of section should not be less than 1.12kg per RM. 2. Cost of rubber beading and required accessories shall be included in the rate of item and will not be paid extra.
S&F for powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) each shutter complete all as specified and directed. Make : Jindal / Hindalco / Indalco. Note : Cost of rubber beading and required accessories shall be included in the rate of item and will not be paid extra.
M&L for Peg set of six Aluminium alloy body 300 mm to 400 mm long complete all as specifed and directed.
M&L for 100 x 100 mm Stainless steel floor trap Anti cockroach proof complete all as specified and directed.
S&F aluminium power coated (colour) section as in kitchen cabinet/ cupboard shelf including hanging self for clothes with aluminium clip/strips, PVC beadings fixed with adhesive on edging window,ventilator,glazed with aluminium shutter (medium weight) of suitable size, one or more rebate,cut to jointed together with cadmium plated steel screws including rubber bending or gasket for aluminium sections for fixing glass/Xpm jalli and necessary fittingd,screws, plugs for fixing screws, etc complete all as specified and directed. (Weight of section should not be less than 0.55 kg per RM.) (Aluminium section shall be of make Jindal/ Hindalco/ Indalco). Note : Cost of rubber beading and required accessories shall be deemed including in the rate of items and will not be paid extra.
M&L for 6mm thick bakelite sheet prelaminated both side with decorative choice lamination work complete all as specified and directed.
M&L for stainless steel (AISI 304 Grade ) Non magnetic multilayer nikle chrome plated for multipurpose utensil container including frame work telescopic channels, handles etc as reqd and complete all as specified and as directed utensil sample, design and pattern of each basket to be approved by GE of the following size in each kitchen (A) plain basket 510x470x100mm or 520x485x100mm or 530x505x150mm slace godrej code 6126 Baan code LKY2PB 2014 -Evershine size 520x485x90mm (b) multisize plate basket of size 510x470x150mm or 520x485x150mm or 436x500x200mm (Clear depth 500mm) 01 nos make Silk Elnora BAAN code LKY-3CS214- Ever shine size 520x485x90mm approved by GE
(c) Cutlery Basket, with Perforated bottom and side of compacted -slots for holding cutlery of size 510x470x100mm or 520x485x100mm or 144x468x50 (Clear depth of 500mm) 01 nos make Silk Elenora (Asian Paint) code 600, size 530x505x100mm (Godrej Product code 6134 BAAN Code LKY2PC214/Ever shine size 520x485x95mm (d) Plain basket of size 510x470x200mm or 520x485x200mm or 486x500x200mm 02 Nos make Silk Elenora (Asian Paint) code 600, size 53x505x200mm- Godrej product code 6128 BAAN code LKY 2PB218- Evershine size 520x485x180mm (e) pull out with 2 basket each of size 150x485x80mm or 100x485x80mm 01 Nos make Sleek Elenora (Asian Paint ) code 250 size 180x500x590mm / Godrej product code 6141 baan code LKYNS2SP6/Ever shine size 610x485x90mm (f) dust bin as reqd 01 Nos Make 200 series of Hettich
S&F mild steel framed work such as grills grating etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars, barrel iron doors ladders framed balusters walk ways railing frame work of water tanks and similar work confirming to Fe -290 Gde-E-165 complete all as specified and directed.
S&F sheet glass 5.5 mm thick ordinary quality and glazing with oil putty in square exc 0.5 Sqm each pane complete all as specified and directed.
SEWAGE DISPOSAL
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft and loose soil complete all as specified and directed.
Removing excavated Soil material exc. 5 km and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for PCC (1:3:6) type (C-2) using 40 mm graded stone aggregate as in bedding of RCC drain pipe 150 mm bore class NP-2 including packing under and completely surrounding the pipes with concrete after they are laid and tested complete all as specified and directed.
M & L for 150 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and joints complete all as specified and directed.
M&L for cement concrete type D2 (1:4:8) (using 40 mm graded stone aggregate) in foundations filling and mass concrete complete all as specified and directed.
M&L for brick work in burnt brick with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in Coping, benching including necessary form work and finishing all exposed surfaces of concrete complete all as specified and directed.
Providing and fixing SFRC (Steel Fibre Reinforced Concrete) cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to IS-12592, total weight of cover and frame to each be not less than 182 Kg, fixed in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
Providing orange colour safety foot rest minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23mmx 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2 mm tread on top surface by ribbing or chequerering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block Plain type C-1 using 20 mm thick stone aggregate (1:3:6) (stone aggregate 20 mm nominal size) complete all as specified and directed.
M&L fot 15mm thick cement plaster mortar in cement and sand mortar (1:4) on faces of brick work or concrete surface mixed with water proofing compound @ 3Kg / 50Kg bag of cement, surface finished even and smooth without using extra cement complete all as specified and directed. (WPC shalll be measured and paid for separately)
M&L for 15mm thick cement plaster mortar in cement and sand mortar (1:3) on faces of brick work or concrete surface mixed with water proofing compound @ 3 Kg / 50kg bag of cement, surface finished even and smooth without using extra cement complete all as specified and directed. (WPC shalll be measured and paid for separately)
Supply only integral water proofing compound ISI marked complete all as specified and directed.
Cutting into existing manholes for connecting new drains internal dia of 150 mm bore NP-2 pipes, making good to pipe and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section) in plain cement concrete (1:2:4) type B-1 using 20 mm thick stone aggregates smooth finished, and reforming benching complete all as specified and directed.
M&L for Reinforced Cement Concrete in nominal mix Type B0 1:2:4 (12.5mm graded stone aggregate) as in cover slabs supported to walls for Manhole to fixing of SFRC cover Haevy duty HD-20 grade designation) etc complete all as specified and directed.
AREA DRAINAGE
M&L for brick work in burnt brick with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius in half brick thick walls built in, built in CM (1:4) complete all as specified and directed.
M & L for 50mm thick plain cement concrete type D-2 (1:4:8) (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
ROAD, PATH & CULVERT
M&L for Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed.
Dismantling of Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed.
M & L for 75mm thick plain cement concrete type D-2 (1:4:8) (40 mm graded stone aggregate) as in sub base flooring complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement and no pigment, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed.
M&L for PCC precast Kerb stone outer coloured surface machine pressed factory made of size 300mm long, 300mm wide and 150mm deep as in PCC (1:2:4) type B1 (using 20 mm graded stone agg) including form work weathering, slightly rounded or chamfered angles and throating complete all as specifed and directed
M&L for providing cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in benching, coping, bed blocks including necessary form work, weathering slightly rounded or chamfered angles and throating, complete all as specified and directed.
WALL / FENCING / GATE
Dismantling fencing wire mesh any type complete all as specified and directed.
Dismantling posts and struts (wood, steel or RCC) any section, including taking out embedded portion in concrete and making good disturbed ground complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum in soft/loose soil and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 mtr. complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 ( using 40 mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, wind ties, etc.; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
Supply only chain link fencing, galvanised mild steel of mesh 50mm x 50mm size, 3.8 mm gauge complete all as specified and directed.
Fixing only chain link fencing, including line wires 50mm x 50mm mesh, 4mm gauge galvanised mild steel to any type of standards, rails, straining bolts etc including provison of binding wire complete all as specified and directed.
S & F of Mild steel round bars 10mm dia and over Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F of Mild steel screw bolts (machine made) of neck diameter 10 mm & 50mm long with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st quality) over a coat of red oxide primer including preparation of new steel or iron surfaces exc 10 cm width or girth complete all as specified and directed.
M&L for Brick work in CM (1:6) with sub class 'B' bricks built in one brick thick with old bricks straight or curved on plain surfaces complete all as specified and directed.
M&L for PCC (1:3:6) type C1 using 20mm graded stone aggregate as in coping of wall incl necessary formwork etc complete all as specified and directed.
M&L for framed work as in doors or ornamental and intricate design gates of angle or other section with gusset plates, rails, braces, including pintal etc. complete, drilled for fixing of steel sheeting or othercovering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe-410- W(Gde- E-250) quality- B complete all as specified and directed.
INTERNAL ELECTRIFICATION
Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down carefully unserviceable main switch DBs of any description of an size in any position complete all as specified and directed.
Taking down submain wiring including all accessories complete all as specified and directed.
M&L for concealed type wiring for one light/ fan/ bell point controlled by one switch with 1.5 Sqmm (Nominal area) PVC insulated, unsheathed, stranded copper, conductor cable (1100Volts grade) FRLS, ISI marked, drawn in and including rigid PVC conduits, 20/25 mm dia all as directed with all fittings and accessories alongwith PVC insulated cable with solid copper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 2mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with brass screws,cap and washers incl. making good the disturbed surfaces complete all as below:- Make : Polycab / Havells / Finolex
(a) One light / fan/ exhaust fan point controlled by one switch.
(b) One 5 pin 5 Amp switch socket outlet point on an independent board.
(c) One 5 pin 5 Amp socket outlet point controlled by one switch on same board.
(d) One buzzer/ bell point controlled by one push button on the same board with other switches or independent
All as per item 204 here in before but for one 15 Amp 6 Pin switch socket out let independent with 2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded complete all as specified and directed.
M&L for sub main wiring with two single core 6.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. Make : Polycab / Havells / Finolex (Note :- Two runs of 6.0 sqmm (FRLS) and one run of 4.0 sqmm (FRLS) copper conductor shall be measured as one unit length.)
S&F sheet metal enclosure factory fabricated for Multiphase Out going suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable Amp rated bus bar having IP-42 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed. (Note : MCCB & MCB Shall be Measured and Paid Separately ) Make : C&S Cat No CSDBTPNVDD04S, Legrand Cat No 507720, Indo Asian Cat No 811893
S&F for MCCB 100 Amp,415 V 16 KA, 4 Pole including complete electrical connection by appropriate size of copper lugs complete all as specified and directed. Make : C&S Cat No CSE1M125ATM4P, Legrand Cat No 420415, Indo Asian Cat No 830272
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed. Make : Anchor, Cona, Plaza
S&F socket out let 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed. Make : Anchor, Cona, Plaza
S&F switch piano type 5/15 Amp flush type 240 volt complete all as specified and directed. Make : Anchor, Cona, Plaza
S&F socket combination out let 6 Pin 2 in 1, 5/15 Amp flush type 240 Volt complete all as specified and directed. Make : Anchor, Cona, Plaza
S&F bell push flush type 5 Amp complete all as specified and directed. Make : Anchor, Cona, Plaza
S&F bell ding dong musical ,AC, 230 Volt, single pole complete all as specified and directed. Make : Anchor, Cona, Plaza
Supply and Fixing ceiling rose PVC / Poly carbonate, Isolated body, three terminal AC 230 volts complete all as specified and directed. Make : Anchor, Cona, Plaza
M & L for replacement of lamp holder, PVC / Poly carbonate, insulated body with back plate batten/angle type for batten fittings complete all as specified and directed. Make : Anchor, Cona, Plaza
S&F MCB SPN 63 Amp 240 volt complete all as specified and directed. Make : C&S Cat No CSMBS1B63N, Legrand Cat No 408620, Indo Asian Cat No 811056
S&F MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed. Make : C&S Cat No CSMBS1B63, Legrand Cat No 408595, Indo Asian Cat No 811016
Supply and fix flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete including taking down old unserviceable complete all as specified and directed. C&S Cat No CSDBSPNDDA2+08, Legrand Cat No 507611, Indo Asian Cat No 811807
S&F in replacement LED mirror light fitting of 1 x 10 watt T-5 lamp type with electronic ballast of suitable capacity, clear acrylic cover including mounting on wall complete all as specified and directed. Make : Crompton Cat No LLL-10-CDL, Wipro Cat No Wipro Magma LED 10W, Havells Cat No ENDURALINEARNEOBS10WLED865SPCWH
Supply and fixing surface mounting LED light fitting PVC extruded T-5 batten , 20 Watt, 4 feet including connection with 23/0.0076 three core PVC flexible cable etc complete all as specified and directed. Make : C&S Cat No TATRA-Ei/20W, Crompton Cat No LCTL18CDL+LLT8-20, Havells Cat No ENDURALINEARNEOBS20WLED865SPCWH+CRYSTAL, 1213TBDSTL20WLED865SGLASS
Taking down carefully unserviceable ceiling fan and deposited to E/M store yard complete all as specified and directed.
Taking down carefully unserviceable exhaust fan and deposited to E/M store yard complete all as specified and directed.
Taking down carefully old unserviceable water heater(Geysers) complete all as specified and directed. (Note:- Old geysers should be deposited to AGE E/M store yard)
Taking down carefully the old unserviceable electronic/ electric meter from wooden board and deposited to E/M store yard complete all as specified and directed.
Material & Labour for earthing complete including taking out old unsv and replace with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 mm dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced complete all as specified and directed.
Supply only LED lamp 12 Watt, 230 V , AC integrated circuit complete all as specified and directed. Make : Crompton, Bajaj, C&S
Supply & Fixing security light fitting, LED type, 20 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source with integrated electronic driver complete with M&L GI pipe mounting bracket of size 25/32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed. Make : C&S Cat No LTESS20WLED/LS, Crompton Cat No LST-20-CDL, Surya Cat No SLE UL 20WIP66 LXN
Supply, installing, testing and commissioning BLDC (Brussless direct current) 5 star 230 volt ceiling fan of size 1200 mm sweep with compatible regulator operation complete all as specified and directed. Make : Bajaj, Havells, Orient, Philips.
Supply, installing, testing and commissioning exhaust fans (PVC body for Bathroom / Iron body for kitchen) 300 mm sweep, 230 volt, AC, 50 Hz single phase with louver complete and including cutting of wall of appropriate size for fixing of exhaust fan and making good complete all as specified and directed. Make : Bajaj, Havells, Orient
Supply, installing, testing and commissioning electric water heater(Geyser) 25 Ltrs capacity, AC, 50 Hz single phase BEE 5 star rated complete with flexible pipe for Hot and Cold water and including connecting up with flexible three core copper conductor etc complete all as specified and directed. Make : Havells-GHWAPXTIV025 / USHA / V-Guard
M&L point wiring for inverter point with provision of 5 Amp switch socket combination with single core wire suitable for inverter wiring in all board for light and fan point including all bedrooms, hall, kitchen toilet etc complete all as specified and directed.
Refixing of old serviceable LED tubelight of 20 W, 4 feet complete all as specified and directed.
S&F indoor decorative LED City-3 light fitting suitable for & including single 12 Watt LED lamp with polycarbonate body with upper globe complete all as specified and directed. Make : Crompton, Wipro, Havells
Supply, installation, testing & commissioning of 1 phase, 2 wire, prepaid Energy meters, BIS15884 marked in the existing meter board / floor / panels with pre payment capacitive touch Digital keyboard based having current range 10-60 Amp, 240V, accuracy class 1.0 along with parallel home display split unit, with inbuilt load control switch, containing provision for TOD & RTC, inbuilt feature sense the DG Mode, capable to define 4 tariff slabs, happy hour & holiday definition complete all as specified and directed. (Cost of connecting to existing system is deemed to be included in the rates quoted). Make : HPL / SECURE / L&T
Supply, installation, testing & commissioning of vending system through server, mapping of consumers complete all as specified and directed. Note : The cost of vending charges for meters commissioned during progress of work shall deemed to be included in the rates. (Per annum charges)
Supply, testing, laying of 6 core control cable to connect meter to Parallel Home Display split unit for remote access of data / operation including two cable end connectors (RJ-11), punching complete all as specified and directed. Make : Havells, Polycab, finolex
Supply and fixing 25 mm dia medium grade, ISI narked PVC conduit along with accessories laid on surface complete all as specified and directed. Make : Havells, Polycab, finolex
Supply and fixing of medium class casing & capping of size (20 mm x 12 mm) alongwith accessories in the surface complete all as specified and directed. Make : Havells, Polycab, finolex
Supply and fixing meter integrated charge's with MES Bareilly Cantt Server one time complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in Hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Hard and dense soil complete all as specified and directed.
M&L for sand cushioning to LT UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) with clean, dry and unwashed sand free from sharp particles including gently punning around cable complete all as specified and directed. Note :- Punned thickness only will be considered for payment.
M&L for laying well burnt brick sub class 'B', old size laid in trenches across the length of cable as protection of under ground cable complete all as specified and directed.
Supply & Laying & testing UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy Duty) 1100 volts grade with stranded aluminium conductor complete of following sizes all as specified and directed. Make : Havells / Kalinga / Paragon / Gloster / Grandlay
(a) 16 Sqmm, 4 core.
(b) 25 Sqmm, 3.5 core.
(c) 95 Sqmm, 3.5 core.
(d) 120 Sqmm, 3.5 core.
(e) 185 Sqmm, 3.5 core.
M&L for boring of holes under road / pavement / hard standing or any other situation means for 80 / 50 mm bore at depth not less than 1.0 meter below ground level for crossing the cable and making good both the ends complete all as specified and directed. Note : GI pipe shall be measured and paid separately.
M&L for galvanized iron pipes, light grade, 40mm bore with fittings laid for protection of LT UG cable under road crossing/culvert / drain or fixed to pole/wall with help of flat iron clamps etc. complete all as specified and directed. Make : Jindal / Prakash / TATA
Taking down of old aluminium conductor / hanging services mains of any description / size from LT poles, panel including dismantling cross arms, bracing, insulators and other steel accessories complete all as specified and directed.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make : Polycab / Havells / Everyday
S&F loop in and loop out box of size 20x15x15 cm made of 1.6 mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on top with provision of aluminium busbar of size 25x2 mm 02 Nos fixed on insulatore and MCB capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc complete all as specified and directed.
Supply, installation, testing and commissioning of LT feeder pillar outdoor type of size 2000 x 1500 x 600 mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in foundation of required / suitable size and as directed at site with angle iron frame of size 70 x 70 x 6 mm, 3 phase, 4 wire, 415 volts 50 Hz fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45 cm and gap between bus bar not less than one inch) and double door handle including locking arrangement with 1 no pad lock of 65 mm as directed before manufacturing the panel including dismantling / disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and same have the following electric controls :- Make : Havells / Schneider / Gaurav Energen
Insulated epoxy coated high conductivity aluminum bus bar 630 Amps (Size 60 mm x 6 mm thick) for phase and neutral complete all as specified and directed.
(A) Incoming
MCCB 250 Amp 35 KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting - 01 No Make : L&T / ABB / Legrand
(B) Outgoing
MCCB 160 Amp 25 KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As outgoing) - 03 Nos Make : L&T / ABB / Legrand
MCCB 100 Amp 16 KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As outgoing) - 02 Nos Make : L&T / ABB / Legrand
LED indicating lamp assembly R, Y, B phase - 06 Set
M&L for fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminium busbar of size 50 mm x 6 mm fixed on porcelain insulators TPN type outdoor weather / vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA sheet encloser 3.15 mm thick with one No. incomer MCCB 100 Amp 16 KA including making connection/ thimbles etc complete all as specified and directed. Make : Havells / Schneider / Gaurav Energen
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -2009 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)2009 complete all as specified and dirfected by Engineer-in-charge. Note : (i) If the desired earth resistance is not found within permissible limit, shall be redone by contractor at no extra cost. (ii) Cost of GI strip 32 x 6mm and 40 mm dia GI pipe light grade upto 7.5 m is included in the rate quoted for this item.
Supply and fixing / laying of galvanized iron strip of size 32 x 6mm as earth continuity conductor provided in between earth test point terminal and upto the equipment including nuts, bolts, and washers complete all as specified and directed. Make : Making of earth test point is also included in the quoted rate.
Supply installing testing and commissioning of AC 3 phase 50 cycle per second 400 KVA capacity transformer copper wound step down out door type 11000/433 volts ( at on no load) double wound oil imeressed neutrally cooled with internal cooling tubes delta connected on primary ( HV) side and star connected on secondary ( LV) side in accordance with vector symbol Dy-11 ( Vector group IV) with neutral brought on secondary ( LV ) ride and having at (+/-) 2.5%, (+/-) 5% and 7.5% taping to be changed by means of hand operated “ OF LOAD” tape changing gear. The maximum temp raised should not exceed 45 degree centigrate in oil and 55 degree centrigrate in HV & LV winding when measured by the resistance method after continuous full load run and in imfident temp of 40 degree C . The transformer shall be IS-1180 (Part-I) (Level-III) complete with standard fitting as mper IS: 1180 (Part-I) (Level-III) and mainly comprising the following:- (a) One cable box on LV side ( secondary side) consist of 4 Nos porcelain bushing with studs made out of copper with nuts and washers and one cable glands suitable for reception of taking out one No 3.5 core LT cable of requested size 1100 volts grade PVC sheathed and PVC insulated armoured heavy duty. Make : Mahendra Engg Ltd / ITE Gurgaon / Crompton Greaves
M&L for XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area3 core size 95 sq mm complete all as specified and directed.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of size 2000 x 1500 x 600mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 70x70x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel. Including dismantling/ disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-
Insulated epoxy coated high conductivity aluminium bus bar 800 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
(A) Incoming
MCCB 630 Amp 36KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting – 01 No. Make : L&T / ABB / Legrand
(B) Outgoing
MCCB 250 Amp 25KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 02 Nos. Make : L&T / ABB / Legrand
MCCB 100 Amp 16KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 02 Nos. Make : L&T / ABB / Legrand
LED Indicating lamp assembly R,Y,B Phase – 06 Set
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq 3.5 core complete all as specified and directed. Make : Polycab / Havells / Gloster
Supply and fixing Air break gang operated triple pole mechnically operated mounted on HT insulators and galvanised steel frame with operating rod of 25 mm bore medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt, 50 HZ supply incl 12 insulator and drop out fuse carrier element complete all as specified and directed.
M&L for construction of open platform for mounting transformer with fencing and gate complete all as specified and shown drawing No. CEBZ/TD-98 sheet 1/2 & 2/2. Fencing shall be made as per drawing CEBZ/TD-50 sheet 1/4 to 4/4, fencing posts shall be of RCC 1:2:4 and gate shall be made as per drawing CEBZ/ TD-120 sheet 1/4 to 4/4 complete all as specified and directed.
Supply and fix ceiling fans of Model MH classic 27W BLDC fan 5 star, 230 volt, 335 RPM, 1200 RPM with remote with all accessories 230V 1200 mm sweep complete all as specified and directed. Make : Bajaj, havells, Orient, Philips, RR fans.
Note : Tenderers may note that amount of credit Rs 14,02,662.50 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/s Arihant Builders
TEAM ACC INFRABUILD PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .