Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC 1ST FLOOR BUILDING NO 49 176 SYAMA BUSINESS CENTRE NH BYPASS VYTTILA ERNAKULAM 682019 | ERNAKULAM | ERNAKULAM | KERALA | 682019 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.2 L+₹37,850.75 (5.58%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.4 L+₹60,429.75 (8.90%)Rejected-Finance TC 25 2201 NNRA 97 NALANDA LANE KOWDIAR NANTHENCODE KOWDIAR P O 695003 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695003 | L3 | Rejected-Finance L3 |
Tender Value
₹7.8 L
EMD Value
₹19,390
Closing Date
2 Dec 2023, 6:00 pmClosed
Executive Engineer (Electrical)
University of Calicut
Providing Local Area Network (LAN) connection for new building of Physical Education
2023_UoC_624030_1
D3/E-Tender No.38/2023-24
Open Tender
Electrical Works
Item Rate
90 days
University of Calicut
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,841
₹19,390
14 Jul 2024
24 Nov 2023
6 Dec 2023
24 Nov 2023
2 Dec 2023
24 Nov 2023
Amount
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. Mm. (1.17.21)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. Mm. (1.17.12)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm. (1.21.1)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm. (1.21.2)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switc. (1.24.3)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outle. (1.24.5)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm). (1.27.2)
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable. (1.53.1)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm. (1.17.23)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door. (2.3.4)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole. (2.10.1)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps. (2.14.2)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (2.16)
Supplying and fixing layer 2, 24 gigabit ethernet port with additional 2 combo gigabit (SF/copper) switch with slot. (od152183/2023_2024)
Supply and fixing fibre module - 1G multi mode. (od152184/2023_2024)
Supplying and fixing 24 port CAT 6 Jack panel fully loaded including termination (Proper numbering should be done). (od152188/2023_2024)
Supplying and fixing SC to SC patch cord. (od152190/2023_2024)
Supplying and fixing media converter 10/100/1000(single mode single). (od152191/2023_ 2024)
Supplying and fixing four pole sheet steel enclosure on surface/recess along with 40 A 415 V 4 pole Isolator complete with connections,testing and commissioning etc.as required. (od152217/2023_2024)
Supplying and fixing 19" double section wall mount 9U 500D Rack with all accessories and including fixing charges. (od152218/2023_2024)
Supplying and fixing 19" double section wall mount 6U 500D Rack with all accessories and including fixing charges. (od152220/2023_2024)
Supplying and fixing fully loaded fibre patch panel (LIU) including complete fibre PiG Tails. etc completed. (od152221/2023_2024)
Supplying and fixing 24 port CAT 6 Jack panel fully loaded including termination (Proper numbering should be done. (od152222/2023_2024)
Supply and fixing optical patch cord (2 mtr) (SC to LC Duplex). (od152223/2023_2024)
Sup[plying and fixing of Cat 6 patch cord 1 mtr.. (od152224/2023_2024)
Supplying and fixing of Cat 6 patch cord 3 metre length. (od152225/2023_2024)
Supply and fixing surface mount box for fixing face plate. (od152226/2023_2024)
Supplying and fixing Cat FACE PLATE and information outlet (Key stone). (od152227/2023_2024)
Supply and drawing optic fibre cable 6 core. (od152228/2023_2024)
Supply & Clamping of DWC pipe ( 50/38 mm or nearest size.) along with accessories for mechanical protection to underground power / communication / OFC/ Signal cables. (od153568/2023_2024)
Supply & Laying of DWC pipe in Hard Soil 0.7 m below ground level including excavation for mechanical protection to underground power / communication / OFC/ Signal cables conforming to IS 14930 Part - II 50/38 mm or nearest size. (od153614/2023_2024)
Supplying and fixing one Splicing Box with complete Splicing for the OFC . (od154091/2023_2024)
Supply laying testing of 12 core single mode out door loose tube armoured 9/125M OS2 type optical, low water peak fibre indoor/ outdoor rated with loose tube diameter 1.8mm (Normal) outer sheath : anti radent anti termite and UV HD polyethylene - back, overall cable Dimensions (Normal) : 10.0 ± 1mm,Mass normal 130 Kg/Km ± 10% Max. Tensile strength Short term : 3400N, Min. Crush resistance- 4200N/10cm, optical performance Max attenuation At 1310mm :0.35 db/km at 1550mm : 0.20db/km, RoHS compliant Make : Molex, Belden, panduit, Commscope. (od154803/2023_2024)
Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe. (90.3.17.2)
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class) (90.16.2.4)
Labour Charges for re-arranging the circuit / light point and clamping the the existing pipe is required for lighting circuit. (od156289/2023_2024)
Supplying and fixing LC to LC patch cord. (od156290/2023_2024)
Mr ALFA Electronics
ELIGHT COMPLETE NETWORKING SOLUTIONS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_940076.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .