Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹29.9 L Quoted ₹31.2 L | L1 | Accepted-AOC Accepted being lowest quoted |
| 2 | L2₹32.9 L+₹1.7 L (5.61%)Rejected-AOC | ₹32.9 L+₹1.7 L (5.61%) | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 3 | L3₹33.1 L+₹1.9 L (6.24%)Rejected-AOC | ₹33.1 L+₹1.9 L (6.24%) | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 4 | L4₹34.0 L+₹2.8 L (8.92%)Rejected-AOC | ₹34.0 L+₹2.8 L (8.92%) | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 5 | L5₹34.1 L+₹2.9 L (9.37%)Rejected-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹34.1 L+₹2.9 L (9.37%) | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
4 Jul 2022, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR MAINTENANCE OF LT OVER HEAD LINE UG CABLE LT PANEL AND OTHER ALLIED ELECTRICAL COMPONENT WITH EARTHING AT OTM ACCN AT MIL STN DHRANGADHRA
2022_MES_532808_1
GE(A)/GNR/TOKEN/23 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹60,000
Yes
24 Sept 2022
22 Jun 2022
6 Jul 2022
22 Jun 2022
4 Jul 2022
29 Jun 2022
22 Jun 2022 - 27 Jun 2022
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard and dense soil and getting out complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid.
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles/struts all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
Taking out sub class burnt bricks from the trenches and stacking at site serviceable /unserviceable bricks for reuse.
Supply and laying sub class old 'B' burnt bricks laid as cable protection cover complete all as specified and directed.
Laying only sub class brunt bricks as cable protection cover all as directed.
Dismantling old unserviceable Steel poles/struts, any size complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (09 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and directed . Note:- Excavation/PCC will be measured and paid separately under relevant items
Dismantling cross-arms of M.S channel or angle sections etc. complete all as specified and directed.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge for the following sizes of cable. Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
(a) 6 Sqmm 2 core
(b) 10 Sqmm 2 core
(c) 16 Sqmm 2/4 core
(d) 35 sqmm 3.5 core
(e) 50 sqmm 3.5 core
(f) 70 sqmm 3.5 core
(g) 95 sqmm 3.5 core
Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable obtained vide item No 7 above all as per existing make complete all as sepcified and directed for the following sizes of cable :-
(a) 35sqmm 3.5 core
(b) 50sqmm 3.5 core
(c) 70sqmm 3.5 core
(d) 95sqmm 3.5 core
Supplying & laying, XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed for following size of cable :-
(a) 6 sqmm 2 core
(b) 10 sqmm 2 core .
(c) 10 sqmm 4 core .
(d) 16 sqmm 4 core .
(e) 35 sqmm 3.5 core
(f) 50 sqmm 3.5 core
(g) 70 sqmm 3.5 core
(h) 95 sqmm 3.5 core
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for cable of following sizes :-
(a) 25 sqmm 3.5 core .
(b) 35 sqmm 3.5 core .
(c) 50 sqmm 3.5 core
(d) 95 sqmm 3.5 core
S&F, in repair, GI pipe 80mm bore, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed.
S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed.
Dismantling of old un-serviceable ACSR conductor of any size and make from LT over head line complete all as specified and directed.
M&L for ACSR squeral type conductor of any size drawn for over head line fixed to insulator with binding wire complete all as specified and as directed.
Re-stringing of existing LT aluminium conductor steel reinforced (ACSR) on over head line of any size on RCC / steel tubular pole by removing of binding wire from insulator and rebinding with aluminium binding wire including fixing of jumpers where necessary complete all as per specified and directed. Note: - Each conductor will be measured separately as one RM for payment.
M&L for stay assembly complete with accessories as shown in electrical plate No. 1, complete with galvanised stay strand of size 7/3.5mm with vitreous porcelain loop type insulator, white, brown or green with over all dimension 65x90 mm, clearance of hole16 mm, stay clamps made out of FI 50mmx 6 mm complete with nut, bolts and washer of galvanised iron including excavation & earthwork in any type of soil and concrete work in PCC (1:3:6) type C-2 using 40mm graded stone aggregate (Pit size 800x600x1200mm) complete all as specified and directed and including taking down old stay assembly.
M&L, in repair, Pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volt grade including taking down unservicebale insulator complete all as specified and directed.
M&L, in repair, shackle type insulator, porcelain vitreous, white, brown or green, 75 mm height, 90 mm dia for working pressure 1100 volt grade including galvanized mild steel straps, 31 x 3 mm washers, insulator GI bolts of 12 mm dia including taking down unservicebale insulator complete all as specified and directed.
Suplying, fabricating & fixing structural mild steel channel, angle, iron, flat iron and brackets etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners,eye hooks, bolts,pole clamps and back plates including nuts, bolts and washers, welding banding cold , or hot drilling holes for insulators bolts in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint complete.
M&L for horinzontal borring under the road in soft/loose strata for insertion of GI tube up to 80mm bore all as directed.
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed for the following capacity of MCCB :-
(a) MCCB of rating 250 Amp, 35/36 KA breaking capacity, 4 pole.
(b) MCCB of rating 200 Amp, 36 KA breaking capacity, 4 pole.
(c) MCCB of rating 160 Amp, 36 KA breaking capacity, 4 pole.
(d) MCCB of rating 125 Amp, 36 KA breaking capacity, 4 pole.
(e) MCCB of rating 100 Amp, 25 KA breaking capacity, 4 pole.
(f) MCCB of rating 63 Amp, 16 KA breaking capacity, 4 pole.
Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. Make : STANDRAD / HAVELLS / ABB/C&S/ L&T
(a) MCCB, 200 Amps, 35/36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 pole
(b) MCCB of rating 160 Amp, 36 KA breaking capacity, 3 pole
(c) MCCB of rating 125 Amp, 25 KA breaking capacity, 3 pole
S&F, in repair, on load change over switch open execution type, front handle operated, 4 pole, 415 volts, 50 Hz, AC supply of 250 Amps cofirming to IS 13947-3, complete all as specified and as directed. Make : Havells Cat Part No. IHCSTO0250 or equivalent to Standerd/ C&S/ L&T
S&F, in repair, on load change over switch open execution type, front handle operated, 4 pole, 415 volts, 50 Hz, AC supply of 200 Amps cofirming to IS 13947-3, complete all as specified and as directed. Make : Havells Cat Part No. IHCSTE0200 or equivalent to Standerd/ C&S/ L&T
S&F, in repair, on load change over switch open execution type, front handle operated, 4 pole, 415 volts, 50 Hz, AC supply of 160 Amps cofirming to IS 13947-3, complete all as specified and as directed. Make : Standard havells/ C&S/ L&T
S&F, in repair, on load change over switch open execution type, front handle operated, 4 pole, 415 volts, 50 Hz, AC supply of 100 Amps cofirming to IS 13947-3, complete all as specified and as directed. Make : Standard/ havells/ C&S/ L&T
S&F, in repair, on load change over switch open execution type, front handle operated, 4 pole, 415 volts, 50 Hz, AC supply of 63 Amps cofirming to havells/ C&S/ L&T IS 13947-3, complete all as specified and as directed. Make : Standard
M&L for fault finding of LT cable by using cable fault dectector machine and other necessary T&P, finding out the spot of cable fault and marking on ground complete for any size and length of cable all as specified and directed. (Note : Fault dectector and other necessary T&P shall be arranged by the contractor without pay any extra cost by the Dept.)
M & L for Danger notice plate of 1.6mm thickmild steel sheet, vitreous enamelledwhite, with letters, figures andconventional skull and bones insignal red colour and fixed withM.S. clamps, bolts and nuts ofapproved size, for LT, 20x15cmsize
Supply and erecting of CI Cable path indicators made out of MS sheet duly marked with LT cable 415 volts and with MS angle embeded in PCC 1:4:8 with 60 cm below ground level and 30cm above ground with sheet paintedby " Blue colour” complete all as specified and directed by Engr-in-charge.
M&L for painting of indoor/outdoor LT panel of any size with two coats of synthetic enamel grey colour paint after throughly scrapping/cleaning the rushed portion and fixing the LT panel door properly do the welding work if necessary and miscelleneous items complete all as specified and directed by Engr-in-Charge
Shree Builders
Marudhar construction company
SNEH TRADERS
M/s SK Traders
Ramdev and Sons
M/s PATEL ENGINEERING
Electricals India
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .