| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | ₹17.5 L Quoted ₹18.5 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹18.9 L+₹36,260 (1.96%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹18.9 L+₹36,260 (1.96%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹21.6 L+₹3.1 L (16.6%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹21.6 L+₹3.1 L (16.6%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹23.1 L+₹4.6 L (24.8%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹23.1 L+₹4.6 L (24.8%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹26.7 L+₹8.2 L (44.2%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹26.7 L+₹8.2 L (44.2%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 Jun 2022, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-T-09/2022-23 REPAIRS / MAINTENANCE / SERVICING / REPLACEMENT OF LT PANELS, FEEDER PILLAR BOXES, LT CABLES AND CONNECTED ITEMS IN DOMESTIC AREA AT AF STATION AMBALA UNDER GE (AF) AMBALA
2022_MES_526246_1
GE AF/AMB-T-09/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹60,000
Yes
8 Aug 2022
25 May 2022
24 Jun 2022
25 May 2022
22 Jun 2022
9 Jun 2022
1 Jun 2022 - 6 Jun 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directeddisposing off complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in coping, bases of poles, post holes, etc. complete all as specified and as directed
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out old cables and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
3.5 core 95sqmm
3.5 core 70sqmm
3.5 core 50sqmm
3.5 core 35sqmm
4 core 25sqmm
4 core 16sqmm
4 core 10sqmm
Supplying, fixing / laying in repairs PVC insulated aluminium conductor cable, 2 core 10sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in connections complete all as specified and as directed
Supplying, fixing / laying steel water tubing, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed for the following bores:
80mm bore
50mm bore
40mm bore
M&L for cutting into roads / paths / hard standing, concrete / tiled / bituminous, etc. for insertion of GI protection / passing through pipes 50 to 80mm bore, at any length at any location including making good the disturbed surfaces after laying of pipes complete all as specified and as directed
M&L for carrying out tests for locating faults in LT cable of any size with the help of fault locator machines, etc. at any location complete all as specified and as directed
M&L for digging up loop of 3.5 core aluminium armoured LT XLPE cable at any location for finding faults and changing the joints and repairing as required and relaying of cable complete all as specified and as directed Notes: (i) Rate shall be inclusive of all excavation, earthwork in any type of soil and making good the disturbed surfaces (ii) Cable joints will be measured and paid separately under respective items herein (iii) Testing to ensure funstionality of the line after repairs shall be done as required. Rate shall be deemed to be included in quoted rate
M&L for cable jointing kit for 1.1kV grade cable for straight through heat shrink type joint, indoor/outdoor type with jointing material and accessories suitable for 4 core, 16/25/35mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for straight through heat shrink type joint, outdoor type with jointing material and accessories suitable for 3.5 core, 50/70/120/150mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for straight through heat shrink type joint, outdoor type with jointing material and accessories suitable for 3.5 core, 185/240/300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, outdoor type with jointing material and accessories suitable for 3.5 core, 150/240mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, outdoor type with jointing material and accessories suitable for 3.5 core, 70/120mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, outdoor type with jointing material and accessories suitable for 4 core, 16/25/35/50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
S&F bus bar chamber, IP-42, of size 600x600x450mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 400A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
M&L for carrying out repairs / maintenance of existing LT panels at any position / location and of any size, by disconnecting connections, etc. cleaning the entire compartments, arranging cables in proper manner, changing burnt lugs by providing new lugs, thimbles, etc., taping with insulated tapes of all naked cable joints/ends, preparation of old treated surfaces and applying one coat of grey synthetic enamel paint including all necessary welding works to reinstate broken / damaged doors, hinges, supports, legs, etc. and cleaning the surrounding upto 2m all around complete all as specified and as directed
M&L for preparation of old steel surfaces including welding work to doors of panels/feeder pillars/junction boxes, replacing hinges with locking arrangement and applying one coat of synthetic enamel ivory paint (smoke grey/ivory colour) after disconnecting all electrical connections and reconnecting after painting complete all as specified and as directed
S&F in repairs stainless steel lock suitable for LT panels / feeders, etc. with two sets of keys of existing pattern complete all as specified and as directed
S&F cover, doors of LT panels/feeders fabricated from CRCA sheet of 2mm thick powder coated (smoke grey tint) of any size including locks, all necessry fittings, handles, hinges, nuts, bolt, etc. as required complete all as specified and as directed
Supply, installation, testing & commissioning of powder coated totally enclosed compartmentalized LT feeder pillar panel, of size 2000x1500x450mm (LxHxD), weather proof, dust & vermin proof, degree of protection IP-55, outdoor type, double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens grey) with matt finish with seven tank pre-treatment process, with gasket between all adjascent units and beneath all covers to render the joint dust proof, doors and covers with cylindrical panel locked fully gasketed with neoprene rubber, with alluminium bus bars, electrolytic grade of adequate rating, as specified, bus bars and interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB and black colour coding, supported on unbreakable, non hygroscopic, SMC insulated supports at sufficiently close interval to prevent sagging of bus bars duly housed in a dedicated compartments, prewired with FRLS PVC insulated coper conductor cable of suitable size properly tagged and secured, joints and connection made with galvanised or cadium plated high tensile nuts, bolts and washers with heavy duty steel cable glands of adequate size for incoming & all outgoing cables including 04Nos. 50x50x6mm thick angle iron supports of not less than each 1.0m height duly painted with anti-corrosive black paint and grouted in PCC 1:3:6 type C-1, at suitable depth as per site requirement including taing down and disposing off old LT panel complete all as specified and as directed for the following:
Panel with the following: (i) 600A rated aluminium bus bar suitable for 3 phase 4 wire system Incoming (ii) MCCB 4P 400A 36kA breaking capacity with adjustable thermal & adjustable magnetic over load protection with ics=100% ocicu= 01No Outgoing (iii) MCCB 4P 200A 25kA breaking capacity with fixed thermal & fixed magnetic over load protection with ics=100% of icu - 02Nos. (iv) MCCB 4P 100A 25kA breaking capacity with fixed thermal & fixed magnetic over load protection with ics=100% of icu - 02Nos
Panel with the following: (i) Aluminium bus bar 600A rating suitable for 3 phase 4 wire system Incoming (ii) MCCB 4P 400A 36kA breaking capacity with adjustable thermal & adjustable magnetic over load protection with ics=100% ocicu= 01No. Outgoing (iii) MCCB 4P -100A 16kA breaking capacity with fixed thermal & fixed magnetic over load protection with ics=100% of icu - 03Nos. (iv) MCCB 4P 63A 16kA breaking capacity - 4Nos.
Panel with the following: (i) Aluminium bus bar 400A rating suitable for 3 phase 4 wire system Incoming (ii) MCCB 4P 250A 36kA breaking capacity with adjustable thermal & adjustable magnetic over load protection with ics=100% - 01No Outgoing (iii) MCCB 4P 160A 16kA breaking capacity with fixed thermal & fixed magnetic over load protection with ics=100% -01No. (iv) MCCB 4P 100A 16kA breaking capacity with fixed thermal & fixed magnetic - 01No (v) MCCB 4P 63A 16kA breaking capacity- 4Nos
Notes for serial item Nos. 34 to 37: (i) The location of installation shall be as directed by the Engineer-in-charge (ii) Panels shall be of manufacturer as detailed hereinafter (iii) Contractor shall submit shop drawings from CPRI approved manufactures / fabricators for approval before procurement (iv) Drawings of panels showing location of switchgears shall be got approved from the GE before incorporation at site (v) Single line circuit diagram in A3 sze showing the arrangements of circuit inside the panel shall be provided inside the panel door duly laminated and fixed / pasted (vi) Panel shall be with manufacturer name plate, skull & bone danger notice board, etc.
S&F energy efficient LED street light fitting (beamer), 90W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, minimum 50000 burning hours, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, 90W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down old fittings any type and disposing off complete all as specified and as directed
S&F in repairs on load change over switch 415V 63A 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
S&F in repairs on load change over switch 415V 125A 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
S&F in repairs on load change over switch 415V 250A 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
Supplying, fixing, connecting, testing and commissioning MCCB 63A, 4 Pole, 16kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 100A, 4 pole, 16kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 200A, 4 pole, 25kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 250A, 4 pole, 25kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 315A, 4 pole, 35kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 400A, 4 pole, 35kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 630A, 4 pole, 50kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
S&F in repairs aluminium thimbles complete all as specified and as directed of the following sizes:
16 to 50sqmm
70 to 120sqmm
150 to 240sqmm
300 to 400sqmm
S&F 10mm thick CI cover with handle, duly hinged in mild steel angle iron frame of size 300x300x300mm made out of MS angle iron of size 40x40x6mm thick duly fixed to existing earthing pits and entirely painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer including dismantling and taking down old pit cover and disposing off complete all as specified and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws, taking down and disposing off old unserviceable block complete all as specified and as directed
S&F in repairs air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed
M&L for brazing / welding works on joints of any type of earth strip complete all as specified and as directed
S&F in repairs identifier legend plate of GI of size 300x200x1.6mm mounted on 25mm dia GI pipe of 0.9m length including cutting to required shape/size, welding, marking, necessary painting and writing the date, type of earth pit and resistance value, etc. having approved font type and size complete all as specified and as directed
M&L for preventive maintenance to functional earthing GI/Cu any type, by mechanically checking earth resistance value and bringing up the same to required state by developing and adding new chemical mixture of sodium carbonate, magnesium sulphate, common salt, charcoal, etc. and ensuring required earth resistance value on completion including all necessary excavation/earthwork complete all as specified and as directed
S&F in repairs GI strip of size 32x6mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F in repairs aluminium strip of size 25x3.15mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F PVC / porcelain insulators fixed on walls, etc. complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to steel poles 9/11m high/long with two coats of synthetic enamel paint in black & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to concrete surfaces of electric poles with one coat of synthetic enamel paint in black & white alternate stripes, upto a height of 1m from ground, including writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular black synthetic enamel paint base complete all as specified all as directed
M&L for disconnecting and taking out capacitor bank panel from foundation, in any location, removing to store / workshop for repair works including testing and calibration of APFC relay, repairs to on delay timer, repair/replacement to indicating lamps, repair to all necessary internal wiring of panel with required size copper lead along with lugs, repairs to power capacitor, repair/replacement of 3 position spring return switch with NO & NC elements, repair to ON Delay suitable for mounting on contactors timer and reinstalling panel in its original position including making good the disturbed foundation / platform complete all as specified and as directed Note: Rate quoted shall be inclusive of all necessary T&P, loading / unloading, carting to and fro to workshop, etc.
S&F in repairs power capacitor, cylindrical, power quality heavy duty 25kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power capacitor, cylindrical, power quality heavy duty 20kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power capacitor, cylindrical, power quality heavy duty 5kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power factor controler PFC, 8 stage relay, three phase, 415V, 50Hz of existing type complete all as specified and as directed
S&F in repairs power capacitor duty contactor 3 pole AC1, coil voltage 240V 40A including all connections and testing complete all as specified and as directed
S&F in repairs power capacitor duty contactor 3 pole AC1, coil voltage 240V 63A including all connections and testing complete all as specified and as directed
S&F in repairs MCB TP, C curve, 415V, 6 to 32A, 10kA complete all as specified and as directed
S&F in repairs MCB TP, C curve, 415V, 40 to 63A, 10kA complete all as specified and as directed
S&F in repairs illuminated type push button for control & signalling units, flush integral LED type 230V AC complete all as specified and as directed
S&F in repairs phase indicator lamp with lamp suitable for low/high input, on/off indication, increase/decrease voltage indication, set of 2 pieces each 230V, single phase complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to concrete surfaces of earthing pit walls, etc. with two coats of synthetic enamel paint (of approved tint) complete all as specified all as directed
M&L for preventive maintenance to functional earthing GI/Cu any type, by mechanically checking earth resistance value and bringing up the same to required state by developing and adding new chemical mixture of sodium carbonate, magnesium sulphate, common salt, charcoal, etc. and ensuring required earth resistance value on completion including all necessary excavation/earthwork complete all as specified and as directed
M&L for earthing using GI earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item No. 80: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm light grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
Esha Engineers
The Rahul Vig
sanjeev enterprises
Raman Electric Trading Co
M/S Sonu Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .