Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 CrAccepted-AOC | ₹17.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹18.5 CrRejected-AOC | ₹18.5 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹18.5 CrRejected-AOC BANKERS VILLA VAZHOTTUKONAM VATTIYOORKKAVU P O TRIVANDRUM 695 013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | ₹18.5 Cr | L3 | Rejected-AOC L3 |
| 4 | Rejected-Technical MASTHIKUND HOUSE CHENGALA POST KASARAGOD KERALA 671541 | KASARAGOD | KERALA | 671541 | - | - | Rejected-Technical Non-Responsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non-Responsive |
| Sl No | Description | Qty | Unit | Bankers Construction L3 | SREEKUMAR K S L1 | M/s Crescent Construction Company L2 |
|---|---|---|---|---|---|---|
| 0.00CIVIL WORKS | ||||||
| 1.00SITE CLEARENCE | ||||||
| 1.01 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared | 2,400 | sqm | 16.15 ₹38,760 | 15.91 ₹38,184 | 16 ₹38,400 |
| 1.02EARTH WORK | ||||||
| 1.03 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil | 1,185.86 | cum | 324.93 ₹3.9 L | 320.27 ₹3.8 L | 350 ₹4.2 L |
| 1.04 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.Ordinary rock | 289.36 | cum | 453.91 ₹1.3 L | 447.39 ₹1.3 L | 700 ₹2.0 L |
| 1.05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 948.69 | cum | 282.89 ₹2.7 L | 278.83 ₹2.6 L | 250 ₹2.4 L |
| 1.06 | Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge | 139.13 | cum | 575.32 ₹80,047.15 | 567.06 ₹78,897.89 | 900 ₹1.3 L |
| 1.07 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavatedor stacked materials.All kinds of soil | 292.99 | cum | 116.39 ₹34,101.11 | 114.72 ₹33,611.81 | 250 ₹73,247.50 |
| 1.08PCC WORKS | ||||||
Tender Value
₹16.6 Cr
EMD Value
₹5 L
Closing Date
16 Jun 2025, 3:00 pmClosed
ASSOCIATE VICE PRESIDENT
HLL Lifecare Limited, HLL Bhavan, No26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai 600 100, Tamilnadu
Construction of Critical Care Block (50 Bedded) at TATA Hospital, Kasargode District, Kerala
2025_HCDPS_768167_1
HLL/CMO/HCD/CCB/KGD/25-26
Open Tender
Civil Works - Buildings
365 days
TATA HOSPITAL KASARGODE
Please refer Tender documents.
19 documents required · 19 mandatory
₹17,700
Yes
₹5 L
Yes
4 Oct 2025
5 Jun 2025
17 Jun 2025
5 Jun 2025
16 Jun 2025
5 Jun 2025
Amount
CIVIL WORKS
SITE CLEARENCE
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.Ordinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge
Extra for every additional lift 1.5 m or part there of in excavation / banking excavatedor stacked materials.All kinds of soil
PCC WORKS
Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size)
Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering -All work above plinth level up to floor five level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
RCC WORK
Providing and laying in position ready mixed M-30 grade concrete for reinforcedcement concrete work, using cement content as per approved design mix,manufactured in fully automatic batching plant and transported to site of work intransit mixer for all leads, having continuous agitated mixer, manufactured as per mixdesign of specified grade for reinforced cement concrete work including pumping ofR.M.C. from transit mixer to site of laying, excluding the cost of centering, shutteringfinishing and reinforcement including cost of admixtures in recommendedproportions as per IS: 9103 to accelerate/ retard setting of concrete, improveworkability without impairing strength and durability as per direction of the Engineer- in -charge. All work upto plinth level
Providing and laying in position machine batched and machine mixed design mix M?30 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge.All work upto plinth level.
Providing and laying in position ready mixed M-30 grade concrete for reinforcedcement concrete work, using cement content as per approved design mix,manufactured in fully automatic batching plant and transported to site of work intransit mixer for all leads, having continuous agitated mixer, manufactured as per mixdesign of specified grade for reinforced cement concrete work including pumping ofR.M.C. from transit mixer to site of laying, excluding the cost of centering, shutteringfinishing and reinforcement including cost of admixtures in recommendedproportions as per IS: 9103 to accelerate/ retard setting of concrete, improveworkability without impairing strength and durability as per direction of the Engineer- in -charge.All work above plinth level upto floor V level
Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more
Providing and laying in position machine batched and machine mixed design mix M?25 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge. Note:- Cement content considered in this item is @330 kg/ cum. Excess or less cement used as per design mix is payable or recoverableseparately.All work above plinth level upto floor V level
Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain windowsills, staircases and spiral stair cases up to floor five level excluding the cost ofcentering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarsesand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up to floor five level excluding cost of centering,shuttering, finishing and reinforcement:1:5:10 ( 1 cement : 5 coarse sand : 10 gradedstone aggregate 40 mm nominal size)
FORM WORK
Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc
Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases)
Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges
Centering and shuttering including strutting, propping etc. and removal of form workfor:Foundations, footings, bases for columns
STONE WORKS
DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site
MASONRY WORKS
Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for foundation and basement including all cost of materials,labour charges etc
Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) includingcost of scaffolding complete
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
PLASTERING
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
Extra for plastering exterior walls of height more than 10 m from ground level forevery additional height of 3 m or part thereof.
STEEL WORK
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approvedsteel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required.
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved steel primer, including welding and bolted with special shaped washersetc. complete
DOORS & WINDOWS
Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately).Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)decorative type, core of block board construction with frame of I st class hard woodand well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.35 mm thick including ISI marked Stainless Steelbutt hinges with necessary screws
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressedbutt hinges bright finished of required size with necessary screws. ( Shutter area to bemeasured)
Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Providing and fixing aluminium extruded section body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), withdouble speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pairof handles of approved quality for aluminium door, with necessary screws etccomplete as per direction of Engineer- in- charge.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross?section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame.
Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames
Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the endby end locks, mounted on specially designed pipe shaft with brackets, side guides andarrangements for inside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strength conforming to IS:4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rollingshuttersExceeding 10.00 sqm and upto 16.80 sqm in the area
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilatorsand partitions etc., with G.I. beading of appropriate size. made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applyinga coat of approved fire resistant primer on G.I. beading etc., complete all as perdirection of Engineer-in-chargeWith clear fire resistant glass panes 6 mm thick ofapproved brand, having minimum 60 minutes fire resisitance
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (costof glass excluded ) (overall area of door shutter to be measured):Rectangular orsquare
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & springtype fixing arrangement and making necessary holes etc. for fixing required doorfittings, all complete as per direction of Engineer-in-charge ( Door handle, lock andstopper etc to be paid separately)
Providing and fixing of glass door SS Patch Lock with out handle in toughened glassdoor including all necessary screws etc. complete.
Providing and fixing Steel S.S- 304 (D) Door Pull Both Side Handle of 12 inch, oneSet (2 Handles) ( best make of approved quality ) for Glass, Wooden or similar doorsincluding necessary cutting and making good etc. complete
Supplying and fixing of 2mm thick lead sheet on masonry, wooden, RCC surfaces,etc. using specially treated screws. The lead sheet should be covered with 1 mm thicklaminated plywood of 8mm thick using necessary adhesive, treated screws, etc. Thework should meet the AERB standards, Plated on necessary areas and up o necessaryheight as per the design or the direction of the engineer in charge. Also the corners,joints are covered with lead strips of necessary width, The rate inclusive of labour,materials, the necessary frame work, strips, studs, adhesives, shifting charges, etc.Area 6*3m = 18 Sqm, Add 5% Wastage= 18.9 Sqm
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angleiron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittingscomplete, including applying a priming coat of approved steel primer.Using M.S.angels 40x40x6 mm for diagonal braces
46 mm thick Steel Fire Check Door (Double/Single leaf) of 120 minutes Fire ratingconfirming to BS:476 Part-22 and IS:3614 Part-II. Door shutter are fabricated with0.8 mm thick galvanized steel sheet pressed formed to provide a 46 mm fully flushdouble skin panel lock with seam joint. The internal construction of panel speciallydesign Honey comb structure with reinforcement at all around. The door frames aremade from 1.2 mm thick galvanized steel sheet pressed form of size 100 mm x 57mm
ALUMINIUM WORKS
Providing and fixing factory made uPVC white colour casement/casement cumfixed glazed windows comprising of uPVC multi-chambered frame, sash andmullion (where ever required) extruded profiles duly reinforced with 1.60 +/-0.2mm thick galvanized mild steel section made from roll forming process of requiredlength (shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, stainless steel (SS 304 grade) frictionhinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps andnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, mullion (if required) shall be also fusion weldedincluding drilling of holes for fixing hardware's and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled withweather proof silicon sealant over backer rod of required size and of approvedquality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement windowdouble panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead/ double glazing bead of appropriate dimension. (Area ofwindow above 1.50 sqm).
Providing and fixing casement handle made of zinc alloyed (white powder coated) foruPVC casement window with necessary screws etc. complete.
Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron)
Providing and fixing 100 mm brass locks ( best make of approved quality ) foraluminium doors including necessary cutting and making good etc. complete
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides
Providing and Fixing Aluminium Double U channel of required size for sliding doors
Providing and fixing frosted film in the fixed glass etc. Complete as per the directionof departmental officers
Providing and fixing glazing in door, window, ventilator shutters and partitions etc.with EPDM rubber /neoprene gasket etc. complete as per the architectural drawingsand the directions of engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item): toughened glass of 6 mm thickness.
CUPBOARD WORKS
Providing and fixing Thomson Multi wood board or equivalent make, in shelves withscrews and fittings wherever required, edges to be painted with polyurethane primer(fittings to be paid separately) as per the direction of site Engineer-in-charge.
Providing and fixing concealed hinge of approved quality for 19-20mm thick doorwith stainless steel screws complete
Providing and fixing special quality bright finished brass cupboard or ward robe lockswith four levers of approved quality including necessary screws etc. complete.40 mm
Providing and fixing magnetic catcher of approved quality in cupboard/ward robeshutters, including fixing with necessary screws etc. complete.Triple strip verticaltype
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:75 mm
providing and fixing powder coated telescopic drawer channels 300 mm long withnecessary screws etc. complete as per directions of Engineer -in-charge.
TILE WORKS
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm infloors, jointed with neat cement slurry mixed with pigment to match the shade of thetiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -in?Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to bespecified by the manufacturer), of 1st quality conforming to IS : 15622, of approvedmake, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thickcement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints withwhite cement and matching pigment etc., complete
Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm
Extra for providing opening or required size & shape for wash basin/kitchen sink inkitchen platform, vanity counter and similar location in marble/granite/ stone work,including necessary holes for pillar taps etc. including moulding, rubbing andpolishing of cut edges etc. complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by themanufacturer), with water absorption less than 0.08% and conforming to IS : 15622,of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps,laid with cement based high polymer modified quick set tile adhesive (water based)conforming to IS : 15477, in average 6 mm thickness, including grouting of joints(Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm
Supply and installation of Fire stop mortar system CP 636 - with 63 mm thicknessfor minimum 2 hours fire rating when tested in accordance with UL 1479 standards,for openings in floors or slabs after passing service lines like Metal Pipes. The mortarshall be a light weight cementitious product and shall carry test certificate inaccordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57:and product shoud be LEED certified Test for Vibration-Time-history method andVERTEQII for seismic zone 4. The product shall be age tested as per Dafstb andDIBT standards. The product shall carry test certificate for mold resistance rating of 0as determined by ASTM G21-96. The product shall be UL listed & classifiedand shall bear the UL approval logo on the packing. The rate shall include themineral wool And other miscellaneous items etc.., If none of UL test certificatecomply with actual application, an EJ document prepared by a qualified personneland based on nearest third party tested & approved systems like UL testcertificates & in accordance with IFC guidelines shall be producted bymanufacturer.Firestop installation should be done by hilti recommended applicatorhaving FIT certificate / HAFSC
GLAZING AND CLADDING WORKS
Design supply & installation of suspended Spider Glazing system designed towithstand the wind pressure as per IS 875 (Part-III). The Suspended System held withSpider Fittings of SS-316 Grade Steel of approved manufacturer with glass panelhaving 12 mm thick clear toughened glass held together with SS- 316 Grade Stainlesssteel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass finsand glass panel assembly shall be connected to Slab/beams by means of SS- 316Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of50x25x2mm using fastener & anchor bolts, non staining weather sealants of approvedmake, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, allcomplete to perform as per specification and approved drawings. The completesystem to be designed to accommodate thermal expansion & seismic movements etc.The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channelof the assembly to be filled with non staining weather sealant, so as to make the entiresystem fully water proof & dust proof. The rate shall include all design, Engineeringand shop drawing including approval from structural designer, labour, T&P,scaffolding, other incidental charges including wastage, enabling temporary servicesall fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channellaminated glass etc. all complete. For the purpose of payment, actual elevation area ofGlazing including thickness of joints and the portion of Glass panel inside the SSchannel shall be measured.
Providing and fixing 40mm thick cladding comprising of Wooden framework using25x50mm sections at a maximum spacing of 600mm in any one direction (includingadding members as required) covered with 12mm thick BWP ply layered with 4mmthk. veneer on one side pasted and pressed with adhesive to give a uniform andsmooth finish. including 4mm thk. S.S. strip framework on all sides of veneer panelswith wooden member surround, top moldings / margins, excluding primer and polishetc. to finish the thickness, as shown complete in drawing. All members / ply etc.shall be treated with anti- termite solution as per norms. No extra shall be paid formaking of openings, door / window frames and for making provisions for electricconduits.Details of cost for 10sqmAdd wastage @ 20%
FALSE CEILING
Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size and other endof angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specificationand direction of the Engineer in Charge but excluding the cost of painting with:12.5mm thick tapered edge gypsum moisture resistant board
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm intrue horizontal level, suspended on inter locking metal grid of hot dipped galvanizedsteel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting ofmain "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to centerand cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mmlong spaced between main "T" at 600 mm center to center to form a grid of 1200x600mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mmthick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to formgrids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceilingtiles of approved texture in the grid including, required cutting/making, opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T"runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at1200 mm center to center along main T, bottom exposed width of 24 mm of all T?sections shall be pre-painted with polyester paint, all complete for all heights as perspecifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fullyPerforated Gypsum Board tile made from plaster board having glass fibre conformingto IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mmc/c with centre borders of 48 mm and the side borders of 30 mm, backed with nonwoven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of0.79, with 50 mm resin bonded glass wool backing
Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size and other endof angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and also includingthe cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specificationand direction of the Engineer in Charge but excluding the cost of painting with:12.5mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1
MODULAR OT
Providing and fixing 2 mm anti static seamless conductive Epoxy Flooring (Primer,Screed, ESD Carbonized Coating, Self-leveling Mix Carbonized compound and finalcoating) for Clean room. The floor should be scratch resistant, fire resistant, chemicalresistant, non-corrosive, slip resistant, smooth, anti-fungi, antimicrobial imperviousmaterial conductive enough to dissipate static electricity but not conductive enough toendanger personnel from electric shock. The floor finish should pass over a concealedcove former and continue up the wall for 100mm. The floor should be provided flat towithin a tolerance of ±3mm over any 3-meter area. Copper grounding strip(0.05 thick, 50 mm width) should be laid flat on the floor in the conductive adhesiveand connect to copper wire of grounding. The connection from copper grid should bebrought out uniformly at places to form equipotential grid. A self-leveling compoundshould be laid prior to lying of the floor finish. One earthing lead should be broughtout of from every 150 Sq.ft. area and attaching it to main earthing strip/ground. Finished Floor should be highlydurable with resistance to shock, scratch proof and indentation. Corners should beuniformly Coved Up to 10 cm height. The conductive material should be uniformlyimpregnated as grains. The floor should be inert to body fluids, chemicals, detergentsand disinfectants and it should not be affected by temperature variation within theOT. Colour should be uniform, pleasant and matching with ambiance. The floorshould have electrical resistance (Point to ground) within 2.5x10 to 2.5x106 Ohms asper NFPA-99/ DIN 51953/ATMF-150 B1 class of fire resistance. The floor shouldefficiently discharge electric charges up to 2 KV. The floor should not allow build-upof electrical charge beyond 100 volts due to anti static effect. It should fulfill productrequirements as per EN649. The corner should not be terminated sharply andconcealed cove-former (Aluminium) should be used overlap to a height ofapproximate and sealed perfectly and uniformly. Self-leveling compounds should beused for this purpose.
Providing, Fixing, Installation, and Commissioning of Automatic HermeticallySealing door 1.2 to 1.8m wide, 2.1 to 2.3m height, having high pressure laminate onboth sides that could withstand high abrasion, vision panels (300x500mm). Highgrade aluminium extrusion profile to carry any door weight (till size 2400mm inwidth X 2400mm in height) with deep indentations to ensure perfect hermetic sealing.The door leaf should have high quality synthetic rubber gasket with long life toensure hermetic sealing to maintain pressure differential. Air tightness 99.99% at apressure 100KPa (Test certificate for hermetic sealing with door frame should beprovided with pre-despatch documents. The finished door on either side of the doorshould be perfectly level (maximum permissible difference +1mm). P Door core of 60mm thick built up with 4mm thick HPCL (High Pressure Compact Laminate) skinat both side of the door to provide better strength and rigidity. CFC-free, high densitypolyurethane puff (density 40 kg/m3), thickness 52mm to provide better insulation.Door core is surrounded by 2.5 mm thick high-grade aluminium extrusion profileswith natural anodizing of 15 microns finish. Epoxy Polyester Powder coated as perRAL colours or SS Finish (matt/ mirror finish) The aero- dynamic design of profilesmakes the door ROBUST in its segment league. Gaskets Door blade is made with 3-tier specially designed 3 side heavy duty replaceable EPDM gasket against wallframe. Bottom sealing with 2-tier heavy duty EPDM gasket to flush with finishedfloor. Stainless Steel 304 grade lever handle on both side of the door blade for smoothand easy door opening and closing. High Quality double glazed flush vision windowof Wall Frame High Grade Aluminium extrusion with natural anodized 15-micronfinish wall frame profile. This wall frame profile is 3-sided blind fixed with claddingon wall cut-out section from inside and outside of the room. Including Labour,Transportation, Conveyance etc. The door interlock and access control system shallbe provided with combination of proximity card based, numerical key pad lock basedand push button-based system & foot operating system. The system shall becomplete with access logic controllers, door electromagnets, door release footoperating push button, touchless sensor opening & Closure, emergency doorrelease buttons, PC communicator, control and power wiring and cabling and otherrequired accessories, hardware and software. The access control system shall bepowered through UPS supply for uninterrupted operation even during mains powerfailure. The door Electromagnetic Lock shall be suitable for installation ondoors/frames. The electromagnetic lock and armature shall be constructed anddesigned to provide trouble free service. MAKE: METAFLEX/REBBONE/ALTOSor Equivalent
Supply Installation Testing & Commissioning (SITC) of Wall panels made up ofGI powder coated of 0.4 mm thick sheet on both sides, with 50 mm thick class'O' PUF of min.38kg/m3 density sandwitched in between. The GI sheetshall have 80 micron thick powder coating by hot dip galvanizing with zinc coatingnot less than 180gm/sqm both side of the panel. Scope includes bottom runner, interconnecting profiles, fixingarrangements, silicon sealant application and all other accessories required tocomplete the work as per site requirement. Colour: Powder coated, complete with allnecessary hardware, accessories, fittings and fixtures, as per description in individualitems, technical specifications, drawings and instructions of the EngineerInchargeSelf-supporting wall provided in modular units consisting of external skin in PCGI/PCGI which will be 0.4mm thick ,with protective film to prevent surface damageduring shipping and installation. Movable Wall Includes a) Puff Instulation40kg/m³ b) GI frame work c) Silicon Sealant (Clear/White/Winsil Gray) Note:Necessary cutopens to be made for service outlets and finished after passing theservice outlets, nothing extra will be paid on this account.
Supply Installation Testing & Commissioning (SITC) of modular false ceilingwith powder coated Galvanized Iron of 0.4 mm thick sheet on both sides, 50 mmthick class 'O' PUF of min.38kg/m3 density sandwiched in between. The surface shall be coated with 80-micron thick powder coating by hot dip galvanizingwith zinc coating not less than 180gm/sqm both side of the panel. Scope includesrunner, covings, interconnecting profiles, fixing arrangements, silicon sealantapplication and all other accessories required to complete the work as per siterequirement. Internal GI framework if necessary for support, Silicon Sealant(Clear/White/Winsel Gray), complete with all necessary hardware, accessories,fittings and fixtures, as per description in individual items, technical specifications,drawings and instructions of the Engineer-In charge.
CURTAIN WORKS
Supplying and laying polyester, washable and stain free cloth(Bio-Active fabricwashable germ free suitable for sterile area) curtain curtain system with maximumcurtain curtain cloth height 230 cm(top 30 cm white colour net and 200cm light bluecolor as per approval) stitching with stifiner tape, pleats, ironing and laying aroundeach bed using PVC runner with hooks & stopper for hanging/sliding etc. as perthe direction of engineer in charge including conveyance to site, laying in line andlevel, sealing all cutting in false ceiling with powder coated MS cup, all leads and liftsincluding all labour charges etc. complete. (unpleated length of the clothmeasurement will be considered for payment also the bottom and top foldings will notbe considered in cloth measurement)/ supplying and fixing powder coated 20mm dia.GI round tube hanging support of required length(app. length 1.10m) one end fixingfrom slab by using 6mm dia expansion bolt at a distance not more than 2m, c/c downend fixed to powder coated aluminium channel frame 45 x 20mm x 1mm thicksection by using SS screw as per the direction of engineer in charge includingconveyance.
Providing and fixing of vertical/roller blinds width 100 mm regular quantity madefrom 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure completeopaquety with zero light transmittance, having suitable coating on exterior, includingall fixtures and fittings complete in all respect as per design and instruction ofEngineer in-charge and as per site conditions. The colour will be approved by thecompetent authority.<br> and inclusive of all labour charges.
PAINTING
Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete
Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm
Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete.
Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work
Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerin?charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm
Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerin?charge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm
Applying priming coats with primer of approved brand and manufacture, having lowVOC ( Volatile Organic Compound) content.With ready mixed pink or grey primeron wood work (hard and soft wood ) having VOC content less than 50 grams/ litre
Providing and mixing integral crystalline admixture for waterproofing treatment toRCC structures like basement raft, retaining walls, reservior, sewage & watertreatment plant, tunnels / subway and bridge deck etc.. at the time of transporting ofconcrete into the drum of the ready-mix truck , using integral crystalline [email protected]% (minimum) to the weight of cement content per cubic meter of concrete) orhigher as recommended by the manufacturer's specification in reinforced cementconcrete at site of work. The material shall meet the requirements as specified in ACI?212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, comparedwith control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure.The crystalline admixture shall be capable of self-healing of cracks up to a width of0.50mm. The work shall be carried out all complete as per specification and thedirection of the Engineer-in-charge. The product performance shall carry guaranteefor 10 years against any leakage.
Melamine polishing of approved brand and manufacture on wood work ( one or morecoat).
PLUMBING AND SANITARY FITTINGS
Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid
Providing and fixing white vitreous china flat back half stall urinal of size580x380x350 mm with white PVC automatic flushing cistern, with fittings, standardsize C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) withwaste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P.brass, including painting of fittings and cutting and making good the walls and floorswherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete.
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approvedquality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadthweighing not less than 45 gms
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials withsnap fittings of approved quality and colour, weighing not less than 105 gms
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge.
Providing and fixing C.P brass long nose bib cock of approved quality conforming toIS standards and weighing not less than 810 gms.15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:20 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia
Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10Kgf/cm2 - External work - Exposed on wall
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.15 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.32 mm nominal outer dia pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank.
Providing and fixing PTMT extension nipple for water thank pipe, fittings ofapproved quality and colour .20 mm nominal bore, weighing not less than 40 gms
Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100mm diameter and 1.20 m long complete as per standard design
Providing and fixing of wall mounted foot operated 2 way handwash sink with backsplash (S.S 304 grade top 1.5mm thick and covering 1mm), of overall size 1500mm,600mm, 950(+500) mm. The rate includes material, carriage, shifting up to 5th floor,placing, labour charges, etc., except tap. the placement as per the direction ofengineer in-charge.
Providing and fixing C.P. brass pillar taps with elbow operated levers ISI marked, 15mm nominal bore.
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 263 gms
Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulatedas per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimumcross section as 23 mm x 25 mm and over all minimum length 263 mm and width as165 mm with minimum 112 mm space between protruded legs having 2 mm tread ontop surface by ribbing or chequering besides necessary and adequate anchoringprojections on tail length on 138 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and havingmanufactures permanent identification mark to be visible even after fixing includingfixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design
Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of requiredshape and approved quality.L D - 2.5Rectangular shape 600x450 mm internal dimensions
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32mm nominal outer dia pipes
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow operated levers
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x 1040 mm bowl depth 225 mm
Constructing R.C.C manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) withR.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick withcement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size ) finished with a floating coat of neatcement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg( weight of cover 58 kg and weight of frame 58 kg):
Flexible (coil shaped) PVC waste pipe for sink and wash basin 40 mm dia withlength not less than 700 mm i/c PVC waste fittings.
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solventcement, trenching , refilling & testing of joints complete as per direction ofEngineer in Charge. 150 mm dia 6 Kgf/cm2
Supplying and placing of 5000 Litre 1mm thick stainless steel water tank of 1750mmdia , 2600mm height, Stainless steel mounted stand around 180kg and grade ofASTM A240 gr.304/ SS316 BA/2B as per the direction of Engineer in-charge. Therate inclusive of all the transportation, Steel stand support, loading and unloadingcharges, fixing charges, Labour charges, etc. Nothing shall be additionally paid in thisitem.
Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover withframe (light duty)2x2m internal dimensions, total weight of cover with frame to benot less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slabwith 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominalsize) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3coarse sand) finished smooth with a floating coat of neat cement on walls and bedconcrete etc. complete as per standard design::With common burnt clay F.P.S (nonmodular) bricks of class designation 7.5
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 150 mm dia6Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-ChargeConcealed work, including cutting chases and making good the wall etc. 15 mm pipe10kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2
Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mmdiameter of the inner hinged round grating
ROAD WORKS
Construction of granular sub- base by Providing close graded Material conforming tospecifications, mixing in a mechanical mix plant at OMC, Carriage of mixed materialby tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting withvibratory power roller to achieve the desired density, complete as per specificationsand directions of Engineer-in- Charge.With Material conforming to Grade - I ( sizerange 75 mm to 0.075 mm) having CBR Value- 30
Providing , laying spreading and compacting graded stone aggregate ( size range 53mm to 0.075 mm) to wet mix macadam (WMM) specification including premixingthe material with water at OMC in mechanical mix plant, carriage of mixed materialby tipper to site, for all leads & lifts, laying in uniform layers with mechanicalpaver finisher in sub - base / base course on well prepared surface and compactingwith vibratory roller of 8 to 10 tonne capacity to achieve the desired density, completeas per specifications and directions of Engineer - in- Charge.
2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hotbitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively,including a tack coat with hot straight run bitumen, including consolidation with roadroller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately):WithRefinery Modified Bitumen CRMB 55 conforming to IRC:SP:53 - 1999
Tack Coat - RS Bitumen Emulsion - On W.B.M / W.M.M @ 0.4 kg/ sqm - UsingPacked Bitumen Rates <br> Providing and applying tack coat using bitumenemulsion conforming to IS : 8887, using emulsion pressure distributor includingpreparing the surface & cleaning with mechanical broom. <br> 1. WithRapid Setting Bitumen Emulsion <br> 1. On W.B.M / W.M.M @ 0.4 kg/ sqm
SIGNAGES
Design, providing and fixing Digital Printed vinyl signage boards with transparent3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete asper the per the direction of Engineer in charge. <br>
NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design,Supplying andfixing Name Board as per the technical specifications given -1 Inch GI pipe frame(16Guage) for Frame (Sizeproportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets(Aluminum Composite Panel)for Box area, 18mm thick Multi wood Lettering for Name Board as approvedby<br> Engineer in charge.<br>For Measurement purpose, only area of ACP sheet to be measured
Electrical
POINT WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
CIRCUIT WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in urface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including conduit and all accessories as required for complete installation and instructed by engineer in charge/consultant. 1Cx50sq.mm Copper Flexible Cable
SWITCH , SOCKET AND METAL BOXES
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxes, its interconnections etc. as required complete. Note: UPS sockets, switches and faceplates shall be distinctly color-coded during execution and as per drawing
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
DB,ENCLOSURE AND ITS ACCESSORIES
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - three phase double cover (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying and fixing 40A / 63A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current up to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A-40A, 4P, 30mA.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A, 4P, 100mA
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required up to 25/40A, 2P, 30mA
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A, 4P, 100mA
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 18/25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL (DU125D or similar)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40amps DP Isolator complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply, installation, testing and commissioning of following rating Change Over Switch conforming to IEC 60947-3, IS/IEC 60947 -3, with CRCA sheet powder coated enclosure, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation. 32/40A, 415V, FP COS
Supply, installation, testing and commissioning of following rating Change Over Switch conforming to IEC 60947-3, IS/IEC 60947 -3, with CRCA sheet powder coated enclosure, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation. 25A, 230V, DP COS
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
PANELS
Main Panel:-Supply, Installation, Testing and Commissioning of 415 V 50Hz LT Switch board OEM Design Verified Assembly Panel complying to IEC 61439 Part 1 & 2.The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type , Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition),cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer: - a) 1 Nos 630 A 50 kA 4P MCCB EDO μP based with 3O/C 1E/Releases & S/T O/V relay with CT at neutral earthing conductor b) 1 Set RYB Indication Lamp with control fuses and switches c) 1 no. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring V,A,F,KW,KVA,PF,THDd) 1 no. of Under Voltage/Over Voltage Relay.e) 1 no. Class B & Class C/ Class 1 & Class 2 Surge arrestor device with necessary HRC fuse for protection of same.Outgoings:- a) 1 No 320 A 50 kA TPN MCCB, TM based b) 1 No 250 A, 50 kA, TPN MCCB, TM based c) 6 Nos 160 A 50 kA TPN, MCCB, TM based d) 1 No 250A TPN, Isolator e) ON-OFF-TRIP Lamps with 2A fuse -9 sets f) Surge Protection Devices for Main Panel: Type 1-2 sets g) MFDM supporting RS485, with 2A fuse as per SLD -9 sets, 630 A 415V,50kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. All Breakers in the incoming side shall be with LSIG protection and all the breakers in the outgoing side shall be with LSI protection. ON/OFF/TRIP indicators shall be provided for all the breakers (incoming & outgoing). Necessary spreader terminals, extended ROH, phase barriers, shrouding etc shall be as per the rules. Details as shown in SLD.
Utility Panel: Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a) 160 A 36kA TP+ NL Thermal Magnetic Based MCCB - 1 No. b)1 Set RYB Indication Lamp c)1 No (0-160)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 100A 25kA TP+ NL Thermal Magnetic Based MCCB - 1 No b) 40A -63 A 25kA TP+ NL Thermal Magnetic Based MCCB - 6 Nos, 7 Sets of ON-OFF-TRIP Lamps with 2A fuse and 7 Nos. of Multifunction Digital meter V,A,F,KW,KVA,PF. 160 A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.
HVAC Panel: Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a) 320 A 36kA TP+ NL Thermal Magnetic Based MCCB - 1 No. b)1 Set RYB Indication Lamp c)1 No (0-400)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 100A 36kA TP+ NL Thermal Magnetic Based MCCB - 3 Nos b) 40A-63 A 36kA TP+ NL Thermal Magnetic Based MCCB - 9 Nos,12 Sets of ON-OFF-TRIP Lamps with 2A fuse and 13 Nos. of Multifunction Digital meter V,A,F,KW,KVA,PF. 400 A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.
SMDB-1 GF & FF (4 WAY) - Supply, installation, Testing and Commissioning of factory fabricated OEM 415 V 50 Hz 4 way complying to IEC 61439 part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wire meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc, complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300 mm and maximum upto 1800mm from the finished floor level complete as per the directions of engineer in charge. Incomer -1 no. 160 A 36 kA TP MCCB, Outgoing: 3 Nos 63A 25 kA TP MCCB and 1 Nos 40A TP 25 kA MCCB. Details as shown in SLD.
SMDB-2 SF (4 WAY) - Supply, installation, Testing and Commissioning of factory fabricated OEM 415 V 50 Hz 4 way complying to IEC 61439 part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wire meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc, complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300 mm and maximum upto 1800mm from the finished floor level complete as per the directions of engineer in charge. Incomer -1 no. 160 A 36 kA TP MCCB, Outgoing: 2 Nos 63A-100A 25 kA TP MCCB and 2 Nos 20-50A TP 25 kA MCCB. Details as shown in SLD.
UPS MDB (4 WAY) - Supply, installation, Testing and Commissioning of factory fabricated OEM 415 V 50 Hz 4 way complying to IEC 61439 part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wire meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc, complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300 mm and maximum upto 1800mm from the finished floor level complete as per the directions of engineer in charge. Incomer -1 no. 160 A 36 kA TP MCCB, Outgoing: 4 Nos 50A 25 kA TP MCCB. Details as shown in SLD.
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
Supply, installation, testing and commissioning of following rating MCCB conforming to IEC 60947-3, IS/IEC 60947 -3, with CRCA sheet powder coated enclosure, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation. 200A TP MCCB
CABLE SUPPLY AND LAYING
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but including sand cushioning and protective covering (in ordinary soil). 3.5 core 400 sq mm
Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but including sand cushioning and protective covering (in ordinary soil) 3.5 core 400 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 400 sq mm
Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.<br>120 mm dia (OD-120 mm & ID-103 mm nominal)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (22mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
CABLE TRAY
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
EARTHING PROTECTION
Supply, installation and tesing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, CI cover, CI frame, GI watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc. The CI cover frame/ chamber shall be of 1000mm x 500mm x 600mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. ( value of earth resistance should be less than 1 ohm )
Providing and laying 32 mm X 6 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with SS . nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of SS. nut bolt & spring washer spaced at 50mm)
Providing and fixing 32 mm X 6 mm copper strip on surface/Cable tray or in recess for connections etc. as required. Rate to include cost of suitable GI clamps SS hardware, making welded joints etc all complete with. No holes shall be drilled to the conductor for clamping purpose
Providing and fixing 25 mm X 3 mm copper strip on surface/Cable tray or in recess for connections etc. as required. Rate to include cost of suitable GI clamps SS hardware, making welded joints etc all complete with. No holes shall be drilled to the conductor for clamping purpose
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
LIGHT AND FAN FIXTURES
SITC of 2x 2 LED Recess mounted 36W light fixture, system efficacy >110 lm/W and system lumen output not less than 3600 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor >/=0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, UGR <19, SDCM<5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor < 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.
SITC of LED recessed downlight fixture Maximum 18W (+/-2) light fixture. System efficacy >110 lm/W and system lumen output not less than 1980 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor>/=0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, UGR <19, SDCM<5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLSPVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same
SITC of LED recessed downlight fixture Maximum 10W light fixture. System efficacy >110 lm/W and system lumen output not less than 1800 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor >/=0.95,THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, UGR <19,SDCM<5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same.
SITC of 4 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2200 lumens, luminaire efficacy > 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminium section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K, CRI > 80, power factor >0.95, SDCM < 5, THD <10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation.
SITC of 2 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1100 lumens, luminaire efficacy > 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminum section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K, CRI > 80, power factor >0.95, SDCM < 5, THD <10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation.
SITC of 10W LED BULKHEAD LIGHT fixture , System efficacy>=100 lm/W and system lumen output not less than 1000 lm. , driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor >0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, SDCM<5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make
SITC of 8W LED Spike focus light fixture, polyester coated aluminum, housed in ground/ bush light, offers safe and vibrant parking areas, pathways and gardens, with high illumination and a soothing experience, suitable for landscape lighting with IP 65 protection made of extruded aluminum housing and including all accessories necessary as required to complete installation.
SITC of Suspended LED High Bay Luminaire with a nominal system lumen output of 10000 lumens & minimum system efficacy of 125 lm/W. Luminaire Wattage should not exceed 80W. Luminaire should have a color temperature of 6500K. Driver of the luminaire shall have PF >0.9. Luminaire shall have 110 degree beam angle for better lighting distribution without any patches. Luminaire should be IP65 & IK07 rated. There should be in-built surge protection up to 2 KV. The driver shall comply with IEC 60598, IEC 62384, IEC 61347-2-13, IEC 61547, EMI- CISPR15 standards. The luminaire housing should be made of die cast aluminum with toughened glass front cover, including all accessories necessary as required to complete installation.
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supplying and fixing of required length 32 mm dia G.I. Pipe (light class) including painting etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
SITC of 250mm sweep Exhaust Fan, 900rpm light duty exhaust fan shutter type white colour, 9" or 10" star rated as per BEE, with its all accessories including mounting as required for complete installation.
SITC of 450mm sweep Exhaust Fan Heavy duty , 18 inch, 1400 rpm, single phase heavy duty exhaust fan in metal body with grill/louvers, with its all accessories including mounting as required for complete installation.
SITC of Exhaust Fan Celling mounted type with flexible horse of required length and vent cowl as bird net, Make similar to Luker LXC 200mm 21W 1050RPM Tubular Ventilating Ceiling Mounted Fan or equivalent with its all accessories including mounting accessories.
SITC of 450mm sweep Wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation.
SITC of 750mm sweep, 30 Inch (750 mm) , 3 blades Heavy duty wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply, with all accessories including mounting as required for complete installation.
80KVA Modular(N+1) UPS:-Supply, installation, and commissioning of MODUALAR UPS, suitable Frame size for N+1 with maximum 25kW modules in each frame of 3 phase modules three phase in and out and indoor (IP20) with surge protection system having 30 min backup battery @75 kW load battery sizing calculation to be provided from the OEM, with isolator for each bank battery of reputed approved make ,Input pf 0.99, Input THDi 3%, double conversion technology with input 400V, 50Hz three phase, output 400V, 50Hz three phase, SNMP card for network monitoring, BMS compatibility etc. It shall be 100% generator compatible, with Efficiency 96 % and output power factor Unity (kva = kW), Eco mode Efficiency 99% and including all accessories etc as required. The acoustic noise at 1m of the system should be<80dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE,IEC62040-4 or ISO14025 or equivalent relevant IS standard. The system shall be true online double -conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have 3 level IGBT rectifier and inverter. including rack and interconnecting cables. Battery backup time required is 30 Min. using external SMF batteries. The product offered sufficient battery Ah capacity for required backup.
LIGHTNING PROTECTION
Providing and fixing of fully solid 2m Vertical Air terminal made up of Semi-hard (E-AlMgSiO5), 16mm rod tapered to 10mm.
Providing and fixing of fully solid 3m Vertical Air terminal made up of Semi-hard (E-AlMgSiO5), 16mm rod tapered to 10mm.
Providing and fixing of fully solid 4m Vertical Air terminal made up of Semi-hard (E-AlMgSiO5), 16mm rod tapered to 10mm.
Providing and fixing of Interception Tip made up of Semi-hard (E-AlMgSiO5) to provide on the top of Vertical Air Terminal.
Providing and fixing of Stainless Steel SS 304 Wall Clamp to mount Vertical Air Terminal 1 meter to 5 meter.
Providing & fixing of Concrete Stone Mounting Block for fixing vertical air terminal.
Providing & fixing of Air terminal conductor joining clip for fixing vertical air terminal.
Providing & fixing of Horizontal air terminal conductor (8mm solid aluminium alloy round conductor) made up of Semi-hard (E-AlMgSiO5).
Providing & fixing of Down conductor (8mm solid aluminium alloy round conductor) made up of Semi-hard (E-AlMgSiO5).
Providing & fixing of Terrace conductor (8mm solid aluminium alloy round conductor) made up of Semi-hard (E-AlMgSiO5).
Providing & fixing of whether resistant Nylon Parapet Conductor Holder for fixing horizontal conductor & down conductors. The conductor holder has to fixed using fisher and SS Screws.
Providing & fixing of Terrace Conductor Fibre Reinforce Concrete holder for fixing Terrace Conductor.
Providing Adhesion glue for fixing terrace Conductor Fibre Reinforce Concrete holder.
Providing and fixing of Aluminium Alloy Ferrule T Connector to avoid bimetallic corossion. Crimping has to be done minimum in 9 points for strong bonding.
Providing and fixing of Stainless Steel Clamping Shoe.
Providing and fixing of Aluminium Alloy Expansion Piece to auto adjust climatic variations.
Providing and fixing of Aluminium Alloy Ferrule Straight Connector for Expansion Piece joints and other straight joints to avoid bimetallic corossion. Crimping has to be done minimum in 4 points for strong bonding.
Providing and fixing of Stainless Steel SS 304 Test Joint. The 8mm & 10mm Conductor has to be straightly connected to avoid risk of flash over and needs to have disconnection facility to measure values during testing. it has to be a butterfly type test joint having the provision to dissconnect 8mm Aluminium and 10mm copper bonded steel seperatly in order to test individual earth pit value Minimum 4 screw/bolt joints required for strong bonding.
Providing and fixing of Outdoor Glass Fibre Reinforced Polycarbonate Enclosure having minimum inner dimension of 110mm x110 mm x 67 mm.
Providing and fixing DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 with Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV safefail for 120 Min : 442 V. Health Status Indication in all catridges.Total Response time <25 nano seconds.
Providing and fixing of DIN Rail Surge Protection Device (4+0) Class B+C/ Type 1+2 with Total Impulse current-10 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV safefail for 120 Min : 442 V. Health Satus Indication in all the catridges.Total Response Time <25 nano seconds.
Providing and laying copper coated steel solid round conductor 10mm diameter with copper coating thickness of 100microns for laying conductor after test link and for ring earthing at a depth of 0.5 meters from ground level. Needs to be routed inside heavy duty 20mm PVC pipe after test link @ a height of 2.5 meters from ground level. Including 20mm Heavy Duty PVC Pipe + 20mm Quick Clip.
Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor.
Supply and installation of petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm for underground joints.
Providing and fixing of Stainless Steel SS 304 Earth Rod Connection Point to insert 10mm Copper bonded steel to 20mm Copper Bonded rod. The Connection has to be strongly bonded using strong bolt.
Providing and fixing of 1m earth rod (with 20mm diameter and copper bonding thickness of minimum 250 microns) with exothermically welded clamp on the top as per NBC 2016.
Providing and fixing of 1m earth rod (with 20mm diameter and copper bonding thickness of minimum 250 microns) with with bore and peg arrangement.
Providing and fixing of Impact Point for easy insertion of earth rod to soil.
Providing Earth Enhancing Mineral Compund (12.5kg) for improving earth soil conductivity. It should be pollution free and hazardous substances and chemically inert. Resistivity of the compound has to less than or equal to 0.2 ohm meter.
Providing Earth Enhancing Mineral Compund (5kg) for improving earth soil conductivity. It should be pollution free and hazardous substances and chemically inert. Resistivity of the compound has to less than or equal to 0.2 ohm meter.
Supply and installation of FRP Earth Electrode Inspection Chamber minimum dimenssion has to be 290x290x209mm. Minimum Weight Bearing Capacity has to be 60KN.
SAFETY MEASURES
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply & fixing Laminated drawings of electrical layout, schematic drawing etc. with teakwood frame work on wall as approved by the directorate of electricity
Supply and fixing of Shock treatment chart duly mounted on a wooden frame with glass on front as required in 2 languages (Hindi & English).
Providing & fixing electrical Insulating mats size of 1 Mtrx2Mtr as per IS 15652:2006, 2.0mm thick, suitable for 1.1 KV , fire retardant, no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .
PUMP SET
Supply, installation, testing, and commissioning of a Solar-assisted Heat Pump, an insulated pressurized SS storage tank, a hot water expansion vessel, insulated piping between the system, valves, and accessories required to complete the system in position with the following specifications: The system should have a capacity of 1500 Liters, consisting of Solar Hot Water Panels with an aggregate capacity of 750L (50% of the total requirement). The insulated Hot Water Storage Tank should be suitable for 6 bar pressure, made of SS 316 - 1 number, 1500 Liters, and can be either horizontal or vertical as per site requirements, Hotwater output range 55°c to 60°c. System operating temp. range - 15-43°c. The Heat Pump should have a COP of at least 4, with a minimum 12 KW heating capacity and a minimum 300 LPH flow rate. Storage tank shall include a back up electrical heater capacity of minimum 6KW. A circulation system with a pump (1 working + 1 standby) between the heat pump and storage tank, all inclusive of a control panel is required. Plumbing work should use CPVC pipes with suitable fittings, and brass fittings should include NRV, Y Strainer, Air Vent, MTA, FTA, and Flow Switches, with pipeline insulation. The price shall include all electrical work from the pump panel to the Heat Pump, including cabling, PVC conduits, contactors, suitable fittings, and all accessories in complete as required
Supply, installation, testing and commissioning of 5HP DOL Starter for starting the 5HP 3 phase Monoblock pump as per the direction of Electrical Engineer in charge
SITC of 5 HP Pure Copper Winding Domestic/ Industrial Three Phase Self Priming Monoblock Pump Discharge Range minimum 7.6 lps, as per the direction of Electrical Engineer in charge
Supply, installation, testing and commissioning of single phase pressure boosting pump, 0.6 KW/0.8 HP, 25 mm SUC, and 25 mm DEL., 6 outlets, 3 stages, CI impeller, SS shaft, Mechanical seal, suitable for 35 mtr to 6 mtr head and 20 lpm and 100 lpm discharge respectively, as per the direction of Electrical Engineer in charge
Supply, installation, testing and commissioning of DOL Starter for starting the 0.8hp to 1.5hp single phase pressure boosting pump as per the direction of Electrical Engineer in charge
SOLAR
Supply, Installation, Testing and Commissioning of 20kWp ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Half cut Mono Crystalline Bifacial TopCon solar cell, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required: a) Solar Photovoltaic Module of capacity 585 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
OT ELECTRIFICATION WORKS
Supply installation, testing and commissioning of following three phase to single phase UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with min 30 min backup battery with, input pf>.9, less input current consumption, IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 10kVA Double conversion online ups - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.
SITC of recessed 32W LED peripheral lighting of size 300 x 600 mm or 600mm x 600mm with optical antiglare system for adjustable light distribution and suitable for clean room application, Luminaries cover should be made of highly resistant, disinfectant proof laminated safety glass/acrylic with stylish fine-grained surface. Fittings should be sealed In accordance with the standard IP54
SITC of 10KVA Isolation Panel System, should have isolators provided through leakage relays with EN/CE/UL/BIS/FDA/IEC certification. Specification fault detection feature,medical grade Isolation, compact and mountable on wall.
ELEVATOR
BIDIRECTIONAL HT TOD NET METER
Supply, Installation, testing & commissioning of 3 phase 4 wire according to IS14697-1999, CBIP-325, IS 159595A, class: 0.2S, Bidirectional TOD meter with RS485 port, LCD / LED display of Electricity board approved make, in existing enclosure of Out door USS Transformer at the premises, including all necessary accessories for fixing and connection complete as required getting tested and approved from statutory authorities, TOD meters shall be with communication module with ethernet/Modbus communication protocol for communicating with SCADA software and IBMS. providing connection/inter-connections as required for complete installation and as instructed by engineer in charge/consultant.
DOCUMENTATION AND APPROVAL
DOCUMENTATION AND APPROVAL "Charges for Preparation of all drawings submitting and getting approval from Electrical Inspectorate and Fire Department, submitting of Completion certificates and arranging inspection, getting sanction and energization certificates, obtaining power allocation & power connection from Electrical Inspectorate & KSEB, Initial & Final NOC from Fire Department etc. including feasibility study. for commissioning of the whole installation. All statutory payments will be reimbursed on production of the original receipts. (for modification works)
HVAC - VRF SYSTEM
Supply, Installation, Testing and Commissioning of Air-cooled VRV (Variable Refrigerant Volume) / VRF (Variable Refrigerant Flow) Outdoor units (ODU) equipped with highly efficient, full DC inverter-driven Scroll compressors only, air- cooled heat exchanger having internally grooved copper tubes, and a low-noise condenser fan. The units to have auto-addressing, an auto-check function for connection errors, R-410A/R407C Refrigerant gas. The machine should be fitted with a Noise filter, High-Pressure Switch, Fan Driver Overload Protector, Over-Current Relay, Inverter Overload Protector, etc. The outdoor unit and the rest of the indoor units shall remain in operating condition even when the main line power supply of one or more indoor units fails. The efficiency of the ODU' to meet the latest ECBC/ASHRAE standards. The ODUs shall be provided with suitable vibration isolators. The system should operate up to a minimum ambient DB temperature of 52 degrees Celsius. The unit shall be equipped with an oil recovery system to ensure stable operation with long refrigeration piping lengths. The system must be provided with an oil balancing circuit to avoid poor lubrication. Compatibility with centralized control systems like BACnet, Lon Works, MODBUS is required. ODUs to be suitable for 3-phase, 415 V, 50Hz supply, along with suitable interconnecting control cabling between IDUs, ODUs, and the central controller. All the neccessary power cabling till ODU electrical panel, Pressure Testing, additional refrigerant charging for commissioning, etc., along with all associated accessories neccessary for commissioning of the machine shall be included in the scope of work. VRF Outdoor unit circuit schedule as per tender drawings/specification
Supply, Installation, Testing and Commissioning of VRV/VRF 0.8TR High wall-type Indoor unit complete with a Cordless remote. The machine shall be suitable for operation on 230V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc.
Supply, Installation, Testing and Commissioning of VRV/VRF 1.0TR High wall-type Indoor unit complete with a Cordless remote. The machine shall be suitable for operation on 230V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc.
Supply, Installation, Testing and Commissioning of VRV/VRF 1.6TR High wall-type Indoor unit complete with a Cordless remote. The machine shall be suitable for operation on 230V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc.
Supply, Installation, Testing and Commissioning of VRV/VRF 2.0TR High wall-type Indoor unit complete with a Cordless remote. The machine shall be suitable for operation on 230V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc.
Supply, Installation, Testing, and Commissioning of VRV/VRF 2.4TR Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc
Supply, Installation, Testing, and Commissioning of VRV/VRF 2.8TR Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc
Supply and Installation of INDOOR Refnet / Y-joint separation tubes for refrigeration pipe joints and headers in appropriate orientation to enable proper distribution of refrigerant. The distribution joints should be factory insulated with pre- formed section of expended polystyrene / equivalent.
Supply and Installation of OUTDOOR Refnet / Y-joint separation tubes for refrigeration pipe joints and headers in appropriate orientation to enable proper distribution of refrigerant. The distribution joints should be factory insulated with pre- formed section of expended polystyrene / equivalent.
Supply, Installation, Testing and Commissioning of Centralized Type Remote Controller, color touch screen type with UPS battery backup, all inclusive of necessary installation supports and wiring. The controller must function as an advanced air conditioning management system, providing complete control of VRV/VRF air conditioning equipment (including connected AHUs). It should offer user-friendly operation through its touch screen, icon display, and color LCD display. Units shall be compatible with either BACnet, LonWorks or MODBUS interface. The controller is required to control up to 64 groups of indoor units with the following functions: 1. Starting/stopping of air conditioners as a zone or group or individual unit. 2. Temperature settings for each indoor unit or zone. 3. Switching between temperature control modes, fan speed adjustment, and airflow direction control, including enabling/disabling of individual remote controller operation. 4. Monitoring of operation status, such as operation mode, temperature settings of individual indoor units, maintenance information, and troubleshooting details. 5. Scheduling Indoor Unit Operating Time 6. Displaying air conditioner operation history.
Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/4" (6.35 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:3/8" (9.52 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/2" (12.7 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:5/8" (15.88 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:3/4" (19.05mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:7/8" (22.2 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1.0" (25.4 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/8" (28.6 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/4" (31.8 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specification
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-3/8" (34.9 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/2" (38.1 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 17/18 Gauge with 19mm thick Insulation:1-5/8" (41.3 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels.The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 16/17 Guage with 19mm thick Insulation:1-3/4" (44.45 mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 16/17 Guage with 19mm thick Insulation:1-7/8" (47.62mm) gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant' approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer' (OEM) technical/recommended specifications.
Supply, laying and testing of Protective layer for Copper piping with woven fibre glass cloth wrapped around copper piping tubular insulation and with foster painting as required and as directed by Engineer in charge .
Supply, laying, and testing of shielded copper flexible communication/transmission cabling between VRF indoor units and outdoor units. The communication cable must be routed through PVC conduit. The sizing of the cable to be 2 Core x 1.5 SQMM (or) as per VRF-OEM' technical/recommended specification.
Supply, Installation, testing and commissioning of 25mm dia rigid UPVC condensate drain pipes of following size duly insulated with 9mm thick closed cell nitrile along with necessary clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification.
Supply, Installation, testing and commissioning of 32mm dia rigid UPVC condensate drain pipes of following size duly insulated with 9mm thick closed cell nitrile along with necessary clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification.
Supply, Installation, testing and commissioning of 40mm dia rigid UPVC condensate drain pipes of following size duly insulated with 9mm thick closed cell nitrile along with necessary clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification.
Supply Installation Testing and Commissioning of Condensate Drain Pump, with the following parameters - Max. flow 550L/h @ 0 head, Max. rec. head 5m. Single Phase Supply . All inclusive of accessories, wiring etc. necessary for fixing of the unit Brand: ASPEN / Similar
Supply, Installation, Testing and Commissioning of 8.5TR - 3200 CFM, 50mm E.S.P, VRF Compatible Dx type recirculating factory-built AHUs with 2 Stage Filtration, 6- row Dx cooling coil, Double skin AHU made of 40 mm thick panels consisting of 0.8mm Thick Pre-coated GSS on Outside, 0.8mm Thick Aluminium Sheet Inside with factory-injected PUF of minimum 40 Kg/m3 PUF density. AHU should be ceiling / Floor Mounted type along with Thermal Break Aluminium Extruded Profile at Corners and Joints, complete with Plug Fan with VFD, suitable class IE3 TEFC drive motor with IP55 protection suited for 415 plus/minus 10% volts, 50 Hz 3 phase AC supply, minimum two bend GSS/PVC eliminators, cooling coil section with aluminum finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic type air pre/fine filters (MERV 7 & MERV 14), mixing box, Aluminium VCDs on Fresh air, Return air & Supply air opening, drain connection, 18G Stainless Steel 304 with 19mm NBR Insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, VRF/Dx AHU Kit, Corded Remote Controller, Limits switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254nm wavelength radiation, 7.5 watt/sqft of coil surface area for equal distribution. Heaters (Capacity to be proposed by OEM) to be slip in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, Air stat/ Airflow switch and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power & control cabling, earthing between AHU / Strip heaters and control panel, all supporting GI hangers, ,MS angles, channels nut , bolts, washers etc. necessary for unit installation cost.shall be included in the scope of supply. Fans should be Eurovent/AMCA Certified. AHUs should be Eurovent/AHRI Certified
Supply, Installation, Testing and Commissioning of 11.0TR - 4400 CFM, 50mm E.S.P, VRF Compatible Dx type recirculating factory-built AHUs with 2 Stage Filtration, 6-row Dx cooling coil, Double skin AHU made of 40 mm thick panels consisting of 0.8mm Thick Pre-coated GSS on Outside, 0.8mm Thick Aluminium Sheet Inside with factory-injected PUF of minimum 40 Kg/m3 PUF density. AHU should be ceiling / Floor Mounted type along with Thermal Break Aluminium Extruded Profile at Corners and Joints, complete with Plug Fan with VFD, suitable class IE3 TEFC drive motor with IP55 protection suited for 415 plus/minus 10% volts, 50 Hz 3 phase AC supply, minimum two bend GSS/PVC eliminators, cooling coil section with aluminum finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic type air pre/fine filters (MERV 7 & MERV 14), mixing box, Aluminium VCDs on Fresh air, Return air & Supply air opening, drain connection, 18G Stainless Steel 304 with 19mm NBR Insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, VRF/Dx AHU Kit, Corded Remote Controller, Limits switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254nm wavelength radiation, 7.5 watt/sqft of coil surface area for equal distribution. Heaters (Capacity to be proposed by OEM) to be slip in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, Air stat/ Airflow switch and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power & control cabling, earthing between AHU / Strip heaters and control panel, all supporting GI hangers, ,MS angles, channels nut , bolts, washers etc. necessary for unit installation cost.shall be included in the scope of supply. Fans should be Eurovent/AMCA Certified. AHUs should be Eurovent/AHRI Certified
Supply, Installation, Testing and Commissioning of Inline Exhaust Fan 200CFM @ Minimum 15mm static pressure. Fans must be AMCA CERTIFIED for both air and sound performance. Fan casing shall have galvanized sheet steel. Installation shall be all inclusive of electronic speed regulator, power and control wiring between power supply and fan speed regulator, suitable enclosure, plug top for connecting to the socket, mounting brackets etc. including all necessary accessories as required.
Supply, Installation, Testing and Commissioning of Cabinet Fan (EXHAUST AIR) 600CFM @ Minimum 40mm static pressure. The casing shall be Double-Skin, internally acoustic lined and constructed of galvanized steel. Fans shall be with VFD compatible motor. Fans must be AMCA CERTIFIED for both air and sound performance. Fans shall be equipped with a HEPA filter having filtering efficiency of 99.7% down to 0.3 microns. Installation/quoted price shall be all inclusive of electronic speed regulator for single-phase fans. For three-phase fans, the price shall include a VFD starter panel, along with necessary power and control wiring connecting the power supply, fan, and speed regulator/VFD panel, suitable enclosure, mounting brackets etc. including all necessary accessories as required.
Supply, Installation, Testing and Commissioning of Cabinet Fan (EXHAUST AIR) 800CFM @ Minimum 40mm static pressure. The casing shall be Double-Skin, internally acoustic lined and constructed of galvanized steel. Fans shall be with VFD compatible motor. Fans must be AMCA CERTIFIED for both air and sound performance. Fans shall be equipped with a HEPA filter having filtering efficiency of 99.7% down to 0.3 microns. Installation/quoted price shall be all inclusive of electronic speed regulator for single-phase fans. For three-phase fans, the price shall include a VFD starter panel, along with necessary power and control wiring connecting the power supply, fan, and speed regulator/VFD panel, suitable enclosure, mounting brackets etc. including all necessary accessories as required.
Supply, Installation, Testing and Commissioning of Cabinet Fan (EXHAUST AIR) 1000CFM @ Minimum 40mm static pressure. The casing shall be Double-Skin, internally acoustic lined and constructed of galvanized steel. Fans shall be with VFD compatible motor. Fans must be AMCA CERTIFIED for both air and sound performance. Fans shall be equipped with a HEPA filter having filtering efficiency of 99.7% down to 0.3 microns. Installation/quoted price shall be all inclusive of electronic speed regulator for single-phase fans. For three-phase fans, the price shall include a VFD starter panel, along with necessary power and control wiring connecting the power supply, fan, and speed regulator/VFD panel, suitable enclosure, mounting brackets etc. including all necessary accessories as required.
Supply, Installation, Testing and Commissioning of Cabinet Fan (EXHAUST AIR) 1200CFM @ Minimum 40mm static pressure. The casing shall be Double-Skin, internally acoustic lined and constructed of galvanized steel. Fans shall be with VFD compatible motor. Fans must be AMCA CERTIFIED for both air and sound performance. Fans shall be equipped with a HEPA filter having filtering efficiency of 99.7% down to 0.3 microns. Installation/quoted price shall be all inclusive of electronic speed regulator for single-phase fans. For three-phase fans, the price shall include a VFD starter panel, along with necessary power and control wiring connecting the power supply, fan, and speed regulator/VFD panel, suitable enclosure, mounting brackets etc. including all necessary accessories as required.
Supply, Installation, Testing and Commissioning of Cabinet Fan (EXHAUST AIR) 3000CFM @ Minimum 60mm static pressure. The casing shall be Double-Skin, internally acoustic lined and constructed of galvanized steel. Fans shall be with VFD compatible motor. Fans must be AMCA CERTIFIED for both air and sound performance. Fans shall be equipped with a HEPA filter having filtering efficiency of 99.7% down to 0.3 microns. Installation/quoted price shall be all inclusive of electronic speed regulator for single-phase fans. For three-phase fans, the price shall include a VFD starter panel, along with necessary power and control wiring connecting the power supply, fan, and speed regulator/VFD panel, suitable enclosure, mounting brackets etc. including all necessary accessories as required.
Supply, Installation, Testing and Commissioning of Cabinet Fan (FRESH AIR) 800CFM @ Minimum 40mm static pressure. The casing shall be Double-Skin, internally acoustic lined and constructed of galvanized steel. Fans shall be with VFD compatible motor. Fans must be AMCA CERTIFIED for both air and sound performance. Fans shall be equipped with a 10-micron PRE-FILTER. Installation/quoted price shall be all inclusive of electronic speed regulator for single- phase fans. For three-phase fans, the price shall include a VFD starter panel, along with necessary power and control wiring connecting the power supply, fan, and speed regulator/VFD panel, suitable enclosure, mounting brackets etc. including all necessary accessories as required.
Supply, Installation, Testing and Commissioning of Cabinet Fan (FRESH AIR) 1000CFM @ Minimum 40mm static pressure. The casing shall be Double-Skin, internally acoustic lined and constructed of galvanized steel. Fans shall be with VFD compatible motor. Fans must be AMCA CERTIFIED for both air and sound performance. Fans shall be equipped with a 10-micron PRE-FILTER. Installation/quoted price shall be all inclusive of electronic speed regulator for single- phase fans. For three-phase fans, the price shall include a VFD starter panel, along with necessary power and control wiring connecting the power supply, fan, and speed regulator/VFD panel, suitable enclosure, mounting brackets etc. including all necessary accessories as required.
Supply, Installation, Testing and Commissioning of Cabinet Fan (FRESH AIR) 2500CFM @ Minimum 60mm static pressure. The casing shall be Double-Skin, internally acoustic lined and constructed of galvanized steel. Fans shall be with VFD compatible motor. Fans must be AMCA CERTIFIED for both air and sound performance. Fans shall be equipped with a 10-micron PRE-FILTER. Installation/quoted price shall be all inclusive of electronic speed regulator for single- phase fans. For three-phase fans, the price shall include a VFD starter panel, along with necessary power and control wiring connecting the power supply, fan, and speed regulator/VFD panel, suitable enclosure, mounting brackets etc. including all necessary accessories as required.
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 Thickness 1.00 mm sheet
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 1.00 mm thick
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrile rubber insulation - 25 mm
Supply, installation, testing and commissioning of Acoustic duct lining using 10mm nitrile rubber insulation open cell type inside the ducts, antimicrobial protection at the AHU/Ductable unit outlets upto 4m distance from fan outlet (or)as instructed by Engineer in-charge
Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator
Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
Supply and installation of Fresh Air/ Exhaust Air Louvre of aluminium powder coated with bird Screen as per specifications and drawings.
Supply, Installation and fixing- hanging of FACTORY fabricated fire retardant flexible Canvas connection of minimum 150mm width, at outlet of each Ducted Indoor unit with zipper to facilitate temperature measurement. The fabric to be made of Polyester cloth, black PVC coating on both sides along with galvanised steel seam.
Supply and fixing of prefabricated rigid polyurethane foam (PUF) for making boxing/Trap door ceiling for evaporator / AHU unit. The boxing shall be made out of sandwich panel of 50 mm thick PUF insulation (Nominal density 35 kg/m3), both sides of the panel shall be laminated with 0.50 mm thick galvanized steel sheet coated with polyester paint with strippable polythene sheet. The panel shall be air tight. The pre- fabricated fixing arrangement shall have sufficient thickness powder coated angle frame work, fixing screws, angle fasteners for fixing at ceiling / walls etc
OPERATION THEATRE - HVAC
Supply, Installation, Testing and Commissioning of 11.0TR - 4400 CFM, 100mm E.S.P, Dx type recirculating factory-built AHUs with 2 Stage Filtration, 6-row Dx cooling coil, Double skin AHU made of 40 mm thick panels consisting of 0.8mm Thick Pre-coated GSS on Outside, 0.8mm Thick Aluminium Sheet Inside with factory-injected PUF of minimum 40 Kg/m3 PUF density. AHU should be ceiling / Floor Mounted type along with Thermal Break Aluminium Extruded Profile at Corners and Joints, complete with Plug Fan with VFD, suitable class IE3 TEFC drive motor with IP55 protection suited for 415 plus/minus 10% volts, 50 Hz 3 phase AC supply, minimum two bend GSS/PVC eliminators, cooling coil section with aluminum finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic type air pre/fine filters (MERV 7 & MERV 14), mixing box, Aluminium VCDs on Fresh air, Return air & Supply air opening, drain connection, 18G Stainless Steel 304 with 19mm NBR Insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, Dx AHU Kit, Corded Remote Controller, Limits switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254nm wavelength radiation, 7.5 watt/sqft of coil surface area for equal distribution. Heaters (Capacity to be proposed by OEM) to be slip in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, Air stat/ Airflow switch and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power & control cabling, earthing between AHU / Strip heaters and control panel, all supporting GI hangers, ,MS angles, channels nut , bolts, washers etc. necessary for unit installation cost.shall be included in the scope of supply. Fans should be Eurovent/AMCA Certified. AHUs should be Eurovent/AHRI Certified
Supply, installation, testing and commissioning (SITC) of 11.0TR capacity TWIN Circuit air cooled inverter type Outdoor condensing unit with single/multi scroll compressor as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge R407C/R410A refrigerant gas, vibration isolator pads and saftey devices like thermal protector, pressure relief valve, over load relays single phase preventor, high-low pressure cut out, suitable for three phase 440V Supply.
Supply Installation Testing & Commissioning of Unidirectional Laminar Air Flow (L.A.F) Plenum of Size : 2400 X 1800 mm (8 'x 6'), constructed out of 1.2 mm thick SS 304 sheet with provision/cutout for mounting the swivel light set. The Plenum shall be covered with H13/H14 grade HEPA filters for unidirectional flow across the surface. On the bottom side, a perforated tablet-type stainless steel grill shall be provided as a cover. The cover shall be easily removed when required. The Plenum shall have a differential pressure port for measuring the pressure drop across the HEPA filters. The casing of the HEPA filter shall be made of aluminum, the media of microfiber glass paper, and the bonding of PU resin. Fins shall be aluminum fins-blended type. A polyethylene gasket shall be provided. The pressure drop shall be within 25 mm WC. Performance efficiency shall be 99.997%, and the grade shall be H13/H14 & penetration-0.3 submicron. The suspended laminar air flow (LAF) shall provide ultra-sterile Class 100 clean air and shall be designed to meet Class 5 of ISO 14644-1 standards.
Supply, Installation,testing and commissioning of suitable sized hard drawn copper refrigerant piping(both suction and liquid) including 13mm thick closed cell elastomeric insulation in between indoor and outdoor units as per site conditions
Supply,installation,testing and commissioning of control / transmission wiring between Indoor unit and Outdoor Unit. Cable must be routed through PVC conduits. Cable sizing to be as per OEM recommendation.
Supply, Store, installation, testing and commissioning of 22G (0.8mm) Aluminum duct work in Operation theatres of the above Gauge as appropiate with all accessories, supports, jointing materials, flanges complete all inline with SMACNA Standards and in line with the specifications, drawings etc. The system shall be complete in all respects for commissioning.
Supply, Store, installation, testing and commissioning of 20G (1.0mm) Aluminum duct work in Operation theatres of the above Gauge as appropiate with all accessories, supports, jointing materials, flanges complete all inline with SMACNA Standards and in line with the specifications, drawings etc. The system shall be complete in all respects for commissioning.
Supply, Installation and fixing- hanging of FACTORY fabricated fire retardant flexible Canvas connection of minimum 150mm width, at outlet of each Ducted Indoor unit with zipper to facilitate temperature measurement. The fabric to be made of Polyester cloth, black PVC coating on both sides along with galvanised steel seam.
Supply, Insulation, testing and commissioning of Aluminium volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrile rubber insulation - 25 mm
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator
Supply and installation of Fresh Air/ Exhaust Air Louvre of aluminium powder coated with bird Screen as per specifications and drawings.
Supply & Installation of Return Air Cabinet with 10 micron filter , Size : 22"x14" [Inch], Stainless Steel 304 construction and having internal anti microbial coating . Grill to be Stainless Steel 304 grade. The return air cabinets shall consist of an openable grill and shall be cleanable.
Supply and Installation of OT/Clean Room Parameter System equipped with displaying the following parameters: room temperature , relative humidity & differential pressure ; Instrument supplied should be complete with all necessary sensors, pressure transmission piping and other mounting accessories.
OT VALIDATION - Validation of all OT', as per ISO 14644 norms after commissioning, performing the following tests. • Temperature and Humidity check • Air particulate count • Air Change Rate Calculation • Air velocity at outlet of terminal filtration unit /filters • Pressure Differential levels of the OT with respect to ambient / adjoining areas • Validation of HEPA Filters by appropriate tests.
Supply and Installation of ALUMINIUM CLADDING (26G) for exposed AHU Ducting. Cladding shall be Weather Proof all inclusive of accessories
Supply and fixing of Underdeck insulation with 13 mm thick Fire retardant class nitrile rubber stuck with synthetic adhesive and held in position with GI screw, washer and cross braced with GI 20SWG wire netting
FIRE FIGHTING
PUMPS
Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 70 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 70 m Head
Supplying, installation, testing, and commissioning of an electrically driven pressurization pump suitable for automatic operation, consisting of the following components, complete in all respects, as required: (Jockey Pump) a. Horizontal type, multistage centrifugal pump with a cast iron body, bronze impeller, stainless steel shaft, and mechanical seal, conforming to IS: 1520. b. Suitable HP squirrel cage induction motor, TEFC type, designed for operation on415 volts, 3-phase, 50 Hz AC supply, with IP 55 protection for the enclosure. The motor will be horizontal foot-mounted type with Class-'F' insulation, conforming to IS: 325, and shal be IE3 rated with minimum 75% efficiency. c. M.S. fabricated common base plate, coupling, coupling guard, foundation bolts, etc., as required. d. Suitable cement concrete foundation, duly plastered, with anti-vibration pads. The system will be capable of delivering 180 LPM at a 70-meter head.
PUMP PANELS
PIPES AND ACCESSORIES
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :32 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :40 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm)
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.150 mm. Dia
VALVES
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required200 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required :150mm dia
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as requiredSingle headed Gunmetal
AIR RELEASE VALVE; Supply, installation, testing and commissioning of gunmetal air release valve 25 mm with necessary fittings etc. complete.
Supply, installation, testing and commissioning of lever operated 25mm dia Gate/ball valve conforming to IS 9890:1981 with forged body, brass/stainless steel ball and shall be internally threaded to receive pipe connections 25mm dia
Y STRAINER
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200mm dia
AIR VESSEL
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
SWITCHES
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.100mm dia
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall. d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304)
Supply, installation, testing and commissioning of weather proof hose boxes wall/pedestal type of size 600 x 250 x 400 mm made out of 18 gauge MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.
SPRINKLERS
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, centre bracket, stock bar of following sizes complete as required.1000mm
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Horizontal side wall sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Upright Sprinkler
FIRE BRIGADE
Providing and fixing standard fireman's axe with heavy rubber handle.
Providing fixing SS fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS standards complete with built-in check valves,with 65 mm dia flanged outlet complete with bolts, nuts and rubber insertions as required and as per IS standards
FIRE BRIGADE INLET : Supply, installation, testing and commissioning of 3 way tank filling Inlet connection of 63 mm dia. valves instantaneous coupling type arrangement to be connected to wet riser main.
FIRE EXTINGUSHERS
Supplying, installing and commissioning Portable Fire extinguishers of following type and capacity.Co2 type Fire Extinguisher, made from brand new seamless Steel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Wheel type valve with initial Charge and mounted on Rubber Wheels / wall mounted brackets as per IS: 16018 specification, bearing ISI Mark. 4.5 Kgs
Supplying, installing and commissioning Portable Fire extinguishers of following type and capacity -ABC powder type fire extinguisher with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc.complete, confirming to IS:15683 : 6 Kgs
Clean Agent Modular Type Ceiling mounted Fire Extinguisher 5 Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with Charge of Clean agent (Gas) is also known as HFC Blend A, It is a blend of Hydro Fluoro carbon and organic detossificant essence P26. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 680. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. The Extinguisher shall be externally epoxy powder coated as per IS: 5 Color Shade No. 538: 5 Kgs
SIGNAGES and OTHER
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters FIRE in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckets, duly painted over a coat of primer.
SITC of self glowing "FIRE EXITINGUISHER" sign boards of size (150 X 150 mm) in triangular shape fixed on the wall and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size:300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red /Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum) Double Side Display and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size:300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red /Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with Single Side Display and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Providing and fixing in position the signage " FIRE ORDER" on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non- reflective self adhesive vinyl painted foam board of 2' x 3' and shall be as per IS code 9457:2005, IS 12349, IS 12407
Providing and fixing of Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) on every floor, lettering size shall be 5 Cm. with contrasting colour from background. Size shall be 15cm x 30cm and shall be as per IS code 9457:2005, IS 12349, IS 1240
Providing and fixing of Floor identification signage (e.g., GROUND FLOOR, FIRST FLOOR, etc.) will be placed at each stair enclosure on every floor, displaying the floor number in words. The letter size will be 5 cm, with a contrasting color to the background. The dimensions of the signage will be 15 cm x 30 cm, and it will comply IS Code 9457:2005, IS 12349, and IS 12407.
Providing and fixing of signage : "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" with red letters, each 1.25 cm in height, on a white background. The board dimensions will be 25 cm x 30 cm and will be mounted at a height of 2 meters from the finished floor, positioned near manual call points. The signage will comply with IS Code 9457:2005, IS 12349, and IS 1240 standards.
COPPER PIPING
12mm OD X .7mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, nonarsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348: 2008.The pipes should also be accompanied with manufacturer test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
15mm OD X .9mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, nonarsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 2-01 and conforming to EN13348: 2008.The pipes should also be accompanied with manufacturers test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
22mm OD X .9mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, nonarsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 2-01 and conforming to EN13348: 2008.The pipes should also be accompanied with manufacturers test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
28mm OD X .9mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, nonarsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 2-01 and conforming to EN13348: 2008.The pipes should also be accompanied with manufacturers test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
35mm OD X .9mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, nonarsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 2-01 and conforming to EN13348: 2008.The pipes should also be accompanied with manufacturers test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
VALVES
12 mm BALL VALVE (MGPS) - SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 900 turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
15 mm BALL VALVE (MGPS) - SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 900 turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
22 mm BALL VALVE (MGPS) - SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 900 turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
28 mm BALL VALVE (MGPS) - SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 900 turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
35 mm BALL VALVE (MGPS) - SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 900 turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
GAS OUTLETS AND ACCESSORIES
Gas / Vacuum Outlets - SITC of Gas/Vacuum Outlets with Front loading type terminal outlets designed to dispense medical gases or an inlet for medical vacuum to the secondary equipment flow meters, Surgical Tools, Suction regulators, etc. Terminal unit sealed by O ring. The outlets should Quick Connect Type and gas specificity is accomplished by Diametric indexing / Geometric indexing Should have Push to IN and press-to-OUT mechanism for probes. Allows plugging of probes from front. Parking Type probe / connector Self-sealing valve on disengaging the probe (Quick disconnect) Smooth quite action Non return valve for on line servicing/ repairing , Indexed to eliminate interchangeability of gas services, Colorcoded gas specific front plate Flow rate exceeds the requirements of ISO 9170-1 Totally leak proof, safe & easy to operate Configurations possible: surface, flush ; Bead-head. The terminal outlets should comply with ISO and NFPA. Body shall be of one piece brass construction.
AGSS Outlets-SITC of AGSS Outlets with Front loading type terminal outlets designed to dispense medical gases or an inlet for medical vacuum to the secondary equipment flow meters, Surgical Tools, Suction regulators, etc. Terminal unit sealed by O ring. The outlets should Quick Connect Type and gas specificity is accomplished by Diametric indexing / Geometric indexing Should have Push to IN and press-to-OUT mechanism for probes. Allows plugging of probes from front Parking Type probe / connector Self-sealing valve on disengaging the probe (Quick disconnect) Smooth quite action Non return valve for on line servicing/ repairing , Indexed to eliminate interchangeability of gas services, Color-coded gas specific front plate Flow rate exceeds the requirements of ISO 9170-1. Totally leak proof, safe and easy to operate Configurations possible: surface, flush Bead-head. The terminal outlets should comply with ISO and NFPA. Body shall be of one piece brass construction.
Vacuum regulator with suction bottle - SITC of Single piece wall mounted suction collection & regulation unit With jar capacity of 600 ml each shall be provided at each of the bed side. Jars would be made of autoclavable materials. The units shall be clamped neatly to the wall using suitable clamps
Oxygen Flow meter with Humidifier Bottle - SITC of Flow meter Back pressure Compensated.Flow meter would be accurate gas flow measurement and control within a range of 0-15 liters per minute.It would meet strict precision and durability standards.Flow meter body would be made of brass material. Flow tube and shroud components would be made of clear, impact resistant polycarbonate. The humidifier bottle would be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier would have built in safety valve.
Master control alarm panel- SITC of Microprocessor based with an individualmicroprocessor on each module, A green LED indicator for normal and a red LED indicator for abnormal conditions, Up to 60 functions in a standard configuration, LED Alarm lights utilized for long life, Area Alarm Modules can be intermixed with Master Alarm Modules, maintenance mode for ease of trouble shooting, Self diagnostic circuitry for added reliability, Modules can be upgraded in the field to interface to a building management system or slave alarm, Alarm buzzer in excess of 90 decibels, All modules to be mounted on a hinged frame for easy accessibility, Last alarm flashes, acknowledged alarm shows continuous RED signal, Repeat alarm adjustable 1, 12, 24 hours or off, Dry contacts for remote monitoring of high and low alarms and the distance between the master module and source equipment can be up to 10,000 ft. (3,000 m) as required and as specified under the guidelines laid for Medical gas system, as approved by Engineer HLL
AREA VALVE SERVICE UNIT (AVSU) with Pressure Switch and Alarm of 2 gas - SITC of The AVSU can be installed as a flush or surface mounted and housed in a steel white epoxy coated box and a key operated 900 lock for security, A breakable glass front to the door gives an immediate indication as to the gas type, the allowing access to the valve, The valve type is a 90° shut off ball valve, which is operated via a handle, and each unit comes complete with a blanking plate, which can be fitted, to either side of the valve, Each NIST include non-return valves with 100% sealing, Non-interchangeable NIST connectors are fitted upstream and downstream of the valve. The NIST connectors provide the facility to purge a system before the working gas is introduced and also following any downstream interruption of the supply. The NIST connectors also allow for the pipeline pressure to be tested and provide an easily accessible point for gas sampling. Pressure switches if required can be fitted inside the box to enable local monitoring as specified under the guidelines laid for Medical gas system as approved by Engineer HLL.
AREA VALVE SERVICE UNIT (AVSU) with Pressure Switch and Alarm of 3 gas - SITC of The AVSU can be installed as a flush or surface mounted and housed in a steel white epoxy coated box and a key operated 900 lock for security, A breakable glass front to the door gives an immediate indication as to the gas type, the valve position and the gas flow. In an emergency the glass front can be broken thus allowing access to the valve, The valve type is a 900 lock; shut off ball valve, which is operated via a handle, and each unit comes complete with a blanking plate, which can be fitted, to either side of the valve, Each NIST include non-return valves with 100% sealing, Non-interchangeable NIST connectors are fitted upstream and downstream of the valve. The NIST connectors provide the facility to purge a system before the working gas is introduced and also following any downstream interruption of the supply. The NIST connectors also allow for the pipeline pressure to be tested and provide an easily accessible point for gas sampling. Pressure switches if required can be fitted inside the box to enable local monitoring as specified under the guidelines laid for Medical gas system as approved by Engineer HLL.
AREA VALVE SERVICE UNIT (AVSU) with Pressure Switch and Alarm of 4 gas - SITC of The AVSU can be installed as a flush or surface mounted and housed in a steel white epoxy coated box and a key operated 900 lock for security, A breakable glass front to the door gives an immediate indication as to the gas type, the valve position and the gas flow. In an emergency the glass front can be broken thus allowing access to the valve, The valve type is a 900 lock; shut off ball valve, which is operated via a handle, and each unit comes complete with a blanking plate, which can be fitted, to either side of the valve, Each NIST include non-return valves with 100% sealing, Non-interchangeable NIST connectors are fitted upstream and downstream of the valve. The NIST connectors provide the facility to purge a system before the working gas is introduced and also following any downstream interruption of the supply. The NIST connectors also allow for the pipeline pressure to be tested and provide an easily accessible point for gas sampling. Pressure switches if required can be fitted inside the box to enable local monitoring as specified under the guidelines laid for Medical gas system as approved by Engineer HLL.
AREA VALVE SERVICE UNIT (AVSU) with Pressure Switch and Alarm of 6 gas - SITC of The AVSU can be installed as a flush or surface mounted and housed in a steel white epoxy coated box and a key operated 900 lock for security, A breakable glass front to the door gives an immediate indication as to the gas type, the valve position and the gas flow. In an emergency the glass front can be broken thus allowing access to the valve, The valve type is a 900 lock; shut off ball valve, which is operated via a handle, and each unit comes complete with a blanking plate, which can be fitted, to either side of the valve, Each NIST include non-return valves with 100% sealing, Non-interchangeable NIST connectors are fitted upstream and downstream of the valve. The NIST connectors provide the facility to purge a system before the working gas is introduced and also following any downstream interruption of the supply. The NIST connectors also allow for the pipeline pressure to be tested and provide an easily accessible point for gas sampling. Pressure switches if required can be fitted inside the box to enable local monitoring as specified under the guidelines laid for Medical gas system as approved by Engineer HLL.
MGPS MACHINES
OXYGEN MANIFOLD 10X10 WITH High Pressure Tail Pipe and NRV - SITC of 10 + 10, 2 x 10 Cylinder Oxygen Manifold suitable to withstand a pressure of 140 Kg/Cm2 and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames would be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 pig at site /factory without any additional cost or claim by the contractor for certification and installation, all necessary arrangement for testing shall be under the scope of contractor.
BED HEAD PANEL- Supply,Installation,testing and commissioning of Bed head panels(1.2m) with Terminal unit with accessories - IV Stand, Monitor stand wall mounted, Ward vacuum unit clip, Provision for Gas/Vacuum outlets as follows - One oxygen outlet, One Vacuum outlet, One Compressed Air outlet 4 Bar, Provision for electrical and data connections as per the direction of Engineer in charge
BED HEAD PANEL- Supply, Installation,testing and commissioning of Bed head panels(1.2m) with Terminal unit with accessories - IV Stand, Monitor stand wall mounted, Ward vacuum unit clip, Provision for Gas/Vacuum outlets as follows - Two oxygen outlet, One Vacuum outlet, One Compressed Air outlet 4 Bar, Provision for electrical and data connections as per the direction of Engineer in charge
Emergency set for 2+2 Oxygen cylinder - SITC of Emergency set for 2+2 Oxygen cylinder (Without Cylinder) with regulator and 5 meters high pressure hose. All test certificates and QA/QC should be submitted along for approvals
AUTOMATIC OXYGEN CONTROL PANEL - SITC of automatic control panel having following features -Would be enclosed in a metal cabinet with a hinged cover. The side covers of the panel would be made of fiber glass. Panel cover would be fitted with a lock to prevent unauthorized access can be swung open for maintenance. It would be Fully Automatic Changeover operation and no manual action. The service gas would pneumatically operate gas change over system. Delivery of gas through control panel would not be dependent on electricity. Would be capable of delivering very high flow rate not less than 1300 litres per minute at delivery pressure. Would have Visual indication of the state of the manifold by 3 gauges within the control panel, which would be clearly visible through the transparent cover. Would have Audio – visual alarm indication for changeover of empty cylinder bank to filled cylinder bank. Built in transformer to ensure safe operation by low voltage. Microprocessor based alarm signal control with high siren system and can be operated with single/Three phase AC system at 50 Hz
NITROUS OXIDE MANIFOLD - 2X2 - SITC of 2+2 Size Nitrous Oxide Manifold would be suitable to withstand a pressure of 140 kg/cm2 and above along with high pressure copper annealed tail pipe with end Brass adapter suitable for Nitrous/oxygen Cylinder and Manifold. Top frame comprising of high pressure copper pipes of size 12mm O.Dx1.5mm wall thick, with high pressure brass fitting made of high tensile brass and connections through non –return values; high pressure copper tail pipes ,made of high pressure copper pipe of size 7mm I.d×1.5mm wall thick .The design of middle and bottom frames would be provide to fit both round and flat bottom cylinder safely.The manifold would be tested (hydraulically)at 3500 pig.Nitrous oxide 2+2 mainfold with IOX 14 type regulator for control outlets -Din point for emergency having suitable valve for both on and off purpose.
MEDICAL AIR SYSTEM WITH AIR RECEIVER AND CONTROL PANEL - The compressed Air System are installed 02 Nos 5HP Air - cooled, Splash lubricated and tank mounted Reciprocating type compressor. Capacity to produce 300-500 liters approximately free air delivery at maximum pressure of 90 PSI. It would be fitted with 5 hp capacity induction electric motor of class F insulation It will be pre fitted with slide rails.The compressor would be installed duly fitted with suction filters, after coolers with moisture separator. The moisture separator and after coolers duly fitted with electrically operated auto drain traps will also be provided before air receiver. This system would also have one number vertical MS air receiver as per IS 226 with construction code IS 2825 of 250 ltr WC duly fitted with safety valves, drain valves, pressure gauges etc. An automatic twin chamber heat less air drier would also be installed to dry 20 CFM compressed air at 90-psi pressure at a temperature of 0-40 degree centigrade. Outlet dew point temperature would be 40 degree centigrade. The dryer would be automatic duly fitted with pneumatic operated valve, set of filters, pre-filter, oil filter and duly fitted with pressure gauges for test the filter condition. This system would also be fitted with bypass airline, safety valve for pressure release and pressure indicators. * TECHNICAL SPECIFICATION : AIR COMPRESSOR: 5HP (2 nos) 1.TYPE Reciprocating, 2.Lubrication Splash Lubricated 3.Air delivery 500 lpm., 4.Working Pressure 60 psi, 5.Higher discharge 90-psi, 6.Driver Coupling, 7.Performance test As per IS 5456 8.Stages, 9.Mounting Skid (In case skid mounted) 10.Cooling Air, 11.Compressor speed 650 RPM. ELECTRIC MOTOR: 1.Capacity, 415V 3 Phase, 5.Electric supply 50 Hz. 6.Performance test as per IS 325 7.Starter direct on line 8.Insulation Class F Air Receiver: 1.Construction IS2825 2. Capacity 1000 ltrs, 3.Foundation skid, 4.Blast cap.300psi, 5.Fittings, Pressure gauge Safety valve, Drain trap, Inspection window. Air Drier:-*INLET CONDITIONS 1. Flow Rate 20 cfm 2. Pressure 60psi 3. Temperature 40c Max and Moisture Contents 100%
SITC of 4/7 Bar pressure control in the pipeline system with necessary accessories and all mounting requirements. The control must be easy to operate and have provision for displaying line pressure with necessary cut of valve
AIR DRYER AND BACTERIAL FILTER with 60CFM - SITC of Medical Breathing air dryer consists of Desiccant Air dryer, Pre filter, Fine filter, Carbon filter, Bacterial filter with Voltage : 100 - 240 VAC, 50/60Hz, 1ph Power Consumption : 40 Watt Max, Maximum working pressure : 16 bar (g), Minimum working pressure : 4 bar (g), Rated inlet Temperature : 38 deg0C, Rated inlet pressure : 7 bar(g), CO Level : 10 PPM, (Alarm set point) as per NFPA 99, Air Quality : 20C PDP (Alarm set point), as per NFPA 99, 0.01 micron particle level, Cycle Time : 4 min, Dewpoint dependent change over as per the direction of Electrical Engineer in charge. The air dryer should have large condenser for high ambient temperatures, The dryers have been designed for nominal standard inlet conditions as per ISO 7183 - 2007, Dryer quality class - ISO 8573 - 1 : 2010 (E) class, Working Pressure 15kg/cm2 , Dew Point : 40 Degree.
VACUUM PLANT 2nos of 5HP with 1000 litre Air receiver and Control panel - The vacuum system is installed by providing 2 nos. vacuum pumps of reputed make of single stage , 2 cylinders.This pump is stationary, air cooled; splash lubricated, base plate mounted reciprocating type.This pump would fitted on base plate and belts would be guarded. The company also provide 2 no. vaccum tank of suitable water capacity as per IS 225 and construction code as per IS 2825 with all its accessories like vacuum gauge, drain valve, inspection window etc.The company will provide interconnection copper piping of size 12mm 0.0 to 28mm OD with BSP vertical non return valve of required size with vacuum gauge of required size of bottom connection with silencer entire satisfaction of Hospitals authority. The capacity of the pump would be about 45 cfm per minute vacuum at 684mm (HB). TECHNICAL SPECIFICATION :VACCUM PUMP : (2 NOS), Lubrication Splash, Vacuum/ Suction 45cfm, Vacuum 684mm (HB)(MAX.), Driver Electric Motor, Performance test International Standard, Stages 2, Mounting Skid mounted Vertical, Cooling Air cooled 10. Vacuum speed 600 RPM, ELECTRIC MOTOR : Capacity 5H.P, Insulation Class F, VACCUM RECEIVER : Construction IS2825, Capacity 1000ltr (appox.), Foundation Skid 4. Blast Cap.300psi, Fittings, Pressure Gauge ,Safety Valve ,Drain trap Inspection Window. (Necessary rate for valves also included in this item). The system should have filter, NRV, Silencer, Differential pressure switch.
CARBON DIOXIDE MANIFOLD 1X1 - 1+1 Size carbon dioxide Manifold should be configured with 1 x 1 nos. should be suitable to withstand working pressure of 145 Kg/cm2, along with 2 nos. of high-pressure copper annealed tail pipes with end brass adapter suitable for Carbon dioxide cylinders and manifold.The manifold should be so designed that it should suit easy cylinder changing and positioning. The system should have non-return valves for easy changing of cylinders without closing the bank. The cylinder should be placed with the help of cylinder brackets and fixing chains which shall be zinc plated.
EQUIPMENTS
Single Arm ceiling pendant - Providing, Fixing, Supply, Installation, Testing and Commissioning Single Arm ceiling pendant with 1000mm long arm having weight carrying capacity of the arm will not be less than 100 Kgs, one monitor shelf and provision for six electrical sockets 6/16 Amp one number data and telephone socket and 8 nos of gas outlets.
Double dorm OT light - Supply, Installation, testing and commissioning of double dome OT light with 2,00,000 + 2,00,000 LUX, Field diameter 15-20cm, depth of field 110mm, colour temperature 4300K, colour rendering index 90Ra, intensity control 25-100, type of intensity control by control panel, LED average life of 50,000 hrs, 56 Nos of LED. Optional function: Shadow Compensation, handheld wireless remote controller; smooth light focus adjustment, mutual control for both lamp head, and other functions for your options. Make: MEDILUX ALPHA B
Surgeon Control Panel with Electrical Distribution Board - Providing, Fixing, Supply, Installation, testing and commissioning of Fully Touch Surgeon Control Panel( 6 services ) ,mounted flush in the theatre wall along Distribution Board comprising of the following -1 No Day time Clock (Digital) -1 No Lapse Time Clock (Digital) - Hands free telephone -1 No Medical Gas Alarm -1 Set indicator for temperature & humdity display - Peripheral Lighting On/Off with dimming Control.
M/s Crescent Construction Company (BID ID -2225978)
Bankers Construction (BID ID -2224957)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid