Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC NEW NO 21 OLD NO 42 39TH CROSS ROAD 8TH BLOCK JAYA NAGAR BANGALORE KARNATAKA 560070 | BENGALURU URBAN | KARNATAKA | 560070 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹42.9 L+₹4.9 L (12.9%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹45 L+₹7.0 L (18.4%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
15 Apr 2024, 3:00 pmClosed
Chief Technical Officer with Full Powers of CE
Consultany Wing, Cabin No.245, KSEBL,Vydyuthi bhavanam, Pattom, Thiruvananthapuram
Supply Installation Testing and Commissioning of Pneumatic Tube Transport Systems for Taluk Hospital Kundara.
2024_KSEB_670846_1
CW/KSEBL/14/2023-24 dated 16.03.2024
Open Tender
Electrical Works
Item Rate
90 days
Taluk Hospital Kundara Kollam District
Refer Bid document
4 documents required · 4 mandatory
₹2,950
₹50,000
Thiruvananthapuram
23 Aug 2024
16 Mar 2024
18 Apr 2024
16 Mar 2024
15 Apr 2024
16 Mar 2024
22 Mar 2024
Amount
Pneumatic Tube Transport Systems
Supplying Installation Testing and Commissioning of Control PC with CPU with INTEL 17/linux system with maching hardware details satisfing the performance parameters of PTS with SMPS Cabinet, 3.4GHz/8GB RAM, 1 TB HDD, RS232 Ports, USB Ports, PCI Slot for ISDN/Modem Card, Data Port, Ethernet 100/1000 LAN Card, Standard Keyboard, Standard Optical mouse, 19”-22” flat LCD/LED Monitor, A4 printer, all software and hard ware accessories required and hardware required . including Supplying Installation testing and Commissioning of Control software (pre- loaded on Control PC)with Network viewing; System access and controls for each device on the network; Traffic flow analysis; Delay analysis; Logging of each transaction and error; with transaction ID, Carrier ID send station ID, Receive Station ID, start time and End / Receive time with dates including, Inventory controls; Location of carriers, Password controls, Carrier re-distribution; Pro-remote accessibility; Automatic Return feature of carriers to origin or to station with highest deficit, Programmable timetable for recurring functions etc complete as required.with Network viewing; System access and controls for each device on the network; Traffic flow analysis; Delay analysis; Logging of each transaction and error; with transaction ID, Carrier ID send station ID, Receive Station ID, start time and End / Receive time with dates including, Inventory controls; Location of carriers, Password controls, Carrier re-distribution; Pro-remote accessibility; Automatic Return feature of carriers to origin or to station with highest deficit, Programmable timetable for recurring functions etc complete as required.
Supplying Installation testing and Commissioning of Side Channel Blowers conforming to EC machines directives 98/37/EC and low voltage director 73/23/EEC; DIN EN292 for safety of machines EN60034-1 / DIN VDE 0530 Part 1 for rotating electrical machines; EN 60034-5 / DIN VDE 0530-5 classification of degree of protection DIN EN 60204 for safety of machine electrical equipment of machine, controll drives, starters, protective relays electrical switches,sensors, instrumentation accessories, etc. complete as required.
Supplying, installation, testing & commissioning of Horizontal lab receiving Station conforming to EU Director for Electromagnetic tolerance 2004/108/EC; EEC directive for low voltage devices 93/68/EEC; EEC machines directors 98/37/EEC. Motorised Receiving area with 1.5mtr length; the device should compact size and connected to dedicated and independent power lines. Stations should be equipped with RFID readers for various functions such as Carrier ID and inventory, Carrier ID with properties, permitted addresses or groups, prohibited addresses or groups, automatic destination, sensors,fixing accessories, supports, instrumentation etc. as required
Supplying, installation, testing & commissioning of Standard or Compact Stations conforming to EU Director for Electromagnetic tolerance 2004/108/EC; EEC directive for low voltage devices 93/68/EEC; EEC machines directors 98/37/EEC. Stations are equipped with RFID readers for various functions such as Carrier ID and inventory, Carrier ID with properties, permitted addresses or groups, prohibited addresses or groups, sensors, automatic destination, reject items not identifiable etc. complete as required.
Supplying, installation, testing & commissioning of 160mm System Tube Network which should be of special Imported tubes and U-PVC forwarding bends conforming to DIN6660. Tubes and bends should be smoothly connected with PVC sleeves welded together with special PVC welding glue after cleaning with PVC cleaner includind clamp,cable tie glue, muffle etc complete. The Tubes and bends should be mounted at site using thread rods & tube clips at every 2 to 3 meter distance and should be touch with low elastic distortion, high abrasive resistance difficult to inflame in accordance to DIN4102 — should only burn when it is decomposed by very high temperatures constantly of more than 180 degrees Celsius — including fixing accessories, supports, joining adhesives, clamps etc required as required.
Supplying, installation, testing & commissioning of System Forwarding 160mm Bends of Wall thickness 3.2mm, Radius 800mm. Special Imported U-PVC forwarding bends conforming to DIN6660 along with necessary accessories like Tube clips, tube clamps, special Glue, Special Cleaner, Pvc sleeves. etc. as required.
Supplying, installation, testing & commissioning of Power booster pack at strategic points; made of plastic case as per IP66/67 rating; 200VA. The power pack should be compatible for activation & de-activation of slave power packs through centralized built-in switch and L connection complete as required.
Supplying, installation, testing & commissioning of Carriers or Capsules with carrier rack for secure use; payload up to 3 kg; Impact resistant and crystal-clear polycarbonate middle body; With Loading Dimensions of 330mmH x l20mm ID /as per OEM; with Swivel caps for secure use; Metal-free design through rotation welding procedure etc. complete as required.
Supplying, installation, testing & commissioning of System Control Cable of high-grade composite with grounding, power and data combined all three in one and should be fully screened and use grounded system concept to minimize electromagnetic and radio- frequency interference, including protective pipes, clamps, termination of cables etc complete as required.
Supply installation testing and commissioning of 4 way TPN MCB DB with one number 32A, 4P, 100ma RCBO as incomer and 3 nos 25A TP and 3 nos 16A SP MCB as out going, supply and cablifrom DB to controll panel and control panel to motor, earthing etc complete
Description of Work / Item(s)
Amount
PTS - Comprehensive AMC charges
Comprehensive Annual Maintenance Cost(CAMC) after completion of Defects Liability Period
Comprehensive Annual Maintenance Cost(CAMC) for first year after completion of Defects Liability Period
Comprehensive Annual Maintenance Cost(CAMC) for second year after completion of Defects Liability Period
Comprehensive Annual Maintenance Cost(CAMC) for Third year after completion of Defects Liability Period
Comprehensive Annual Maintenance Cost(CAMC) for Fourth year after completion of Defects Liability Period
Comprehensive Annual Maintenance Cost(CAMC) for Fifth year after completion of Defects Liability Period
SUN MEDITEK PRIVATE LIMITED
SRISHTY MEDICAL PRIVATE LIMITED
MAXLIFE HEALTH ENTERPRISES PVT LTD
SRISHTY MEDICAL PRIVATE LIMITED
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .