PROVN OF CHILDREN SCHOOL (PRIMARY SCHOOL) AT AF RACE COURSE AREA AT AFS AMBALA
2023_MES_583450_2
CEWAC/AMB/T-30/2021-22
Open Tender
Civil Works
Lump-sum
547 days
GE (AF) AMBALA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE (AF) AMBALA
₹3.6 L
Yes
15 Mar 2024
21 Jul 2023
2 Sept 2023
21 Jul 2023
26 Aug 2023
7 Aug 2023
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only.
Provision of Children School (Primary Wing). with permanent specification complete all as shown on drawings and as specified
NOTE: Schedule ‘A’ Part II to X under Ser No 2.01 to 2.09 are Prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “AREA DRAINAGE " as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD, PATH AND CULVERT ” as listed in Schedule ‘A’ Part- VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for "DEMOLITION AND DISMANTLING” as listed in Schedule ‘A’ Part X
SCHEDULE `A' PART - XII MISC ITEMS (B/R & E/M) is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifie this fact only.
INTERNAL ELECTRIFICATION
S&F of lamp holder PVC insulated body with back plate for batten fitting , including 09 Watt LED bulb, complete all as specified and as directed.
S&F LED light fitting 1x10 watt, 220 V, AC, box type with driver, holder connecting up with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and as directed.
S&F LED light fitting 1x40 watt, 220 V, AC, box type with driver, holder connecting up with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and as directed.
S&F LED security 30 watt input 110 to 220 volts as per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and dirver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and as directed
S&F MCB TPN 63 Amps, C curve type 10 KA breaking capacity, 415 Volts complete all as specified and as directed.
S&F MCB SPN 40 Amps, C curve type 10 KA breaking capacity, 240 Volts complete all as specified and as directed.
S&F MCB SP 6 to 32 Amps, C Curve type 10 KA breaking capacity, 240 Volts complete complete all as specified and as directed.
Supply, installetion, commissioning of water cooler partialy stainless steel, electric driven (single phase), having approx storage capicity of 120 Ltr and nominal cooling capacity of 60 ltr per hour. complete all as specified and as directed.
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stablized at 230 Vv with accuracy of +- 2.5% and of capacity 2 KVA. complete all as specified and as directed.
Supply and fixing switch piano flush type single pole 5 Amps 2 Way complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
S&F LED security light fitting 90 Watt, input 110 to 280 Volts volts, Provn of auto shut down on high voltages, life> 50000 Hrs operating temp 1 degree to 50 degree, as per IP 65 luminaries comprsing of rectangular shape, pressure die cast aluminium housing with weather proof gaskets for lamp and driver must be constant current type having THD< 10% and power factor> 0.95 with short circuit protection, open circuit protection, revserse circuit protection, high voltage protection, protection against 10KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60958/IS10322, complete all as specified and as directed.
S&F Secuirty light bracket with GI pipe light grade 40 mm dia bent to shape of lenght 1.2 mtr including flat iron clamp made of FI 40 MM X5MM, nuts, bolts, washers etc duly painted with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F out of door type SMC junctino box of size 250x150x105mm one pice moulded SMC door hinged fxed based with hinged right or left side and fixed to the foundation pole with sutiabel fixing arragement bus bar with single eleectolytic aluminium for both phase and neutal supported on FRP insulator and cut out compelte fixed on teh pole with suitale inlet and ouelet, provisio for cable connectio, kit kat fuse 6 Am,p cap for controllign the pile light, includ9ign ocnnection wtih 4 Sqmm two core PVC unsulated aluminium cable to be down through pole for suitable length from SMC box to fitting complete all as specified and as directed.
S&F PVC copper conductor cable 2x1.5 sqmm through PVC conduit on pole for security light fitting complete all as specified and as directed.
Supply , installtion , commissioning and testing of transformer step down, 11KV/433 volt as pwer IS-1180, Out door type copper wound, suitable for AC, three phase, 4 wire, 50Hz system of capacity 100/KVA, oil immered having Vector group DYN-11 naturally cooled type complete with and including first filling of transformer oil of dielectric strength ≥50 KV, delta connection on HT side, star connection on LT sidem manually operated, off- load tap changer on HT side to vary secondary voltage to +7.5% and -7.5% in steps of 2.5% each losses on 50% load 435W & at 100% load 1500 W cable box at HT & LT side, LT side cable box shall also be fitted with suitable size of cable glands for making connections with all the accessories and the under mentioned fittings all as specified and as directed :- Note : The cost of foundation as per anufacturer recommendation shall be included in the quoted rate and the drawign of the foundation shall be got approved by GE before construction. (a) Rating plate and terminal marking plate. (B) Two earthing terminals for body eathing and two additional for neutral brought out on a bushing (C) Lifting lugs(D) Drain Valve with plug or cover plate(E) Dehydrating breather(F) Oil level indicator with minimum and maximum amrking (G) Cooling Radiator (H) thermometer pocket (I) Conservator (J) Oil filling hole with coverK ) Thermometer 100mm dia/stem type with metal guard having maximum temprature indication with resettng(L) Any other fittings as recommended by the Manufacturer of effecient functioning of the Transforemr (M) Silica gel breather duly filed with slica Gel.
Supply installing testing and commisioning factory made tested (incuding CPRI type test certified frm) out door type, floor mounted LT pannel board cubicale type suitabel for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system havign insulated aluminium bus bar 4 Nos of rating 300 Amps including bus bar chamber, installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protetion and made of 3.15 mm CRCA MS sheet and 40 X40x6mm thick MS anglle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer front opening type, including internal wiring wiht PVC insulated solid copper conductor cable, IS-694 marked, 1100 Volts grade of appropriate size (butno less than 4.0 sqmm) alongwith provision of suitable pawer factor capacitors and capacitors and comprising of the following:-
Incoming: (a) MCCBS 4 Pole, 415 Volts grade, 200 Amps rating and ICU=ICS=25 KA rupturning capacity : 01 Nos main panel) (b) Multifunction Engergy meters in 96x96sqmm flush mounted case with six direct access keys & backlit LCD display, accuracy class 1.0, 5A CT input LV networks AC Auxiliary Supply, Measurement: V, I, In P,Q,S, PF, F, Ea, Er & Es, THD for V & I - 01 set Make: HPL (DIRIS A20) or equivelant modal approved by GE. (c) CTs of ratio 200/5, class-1, VA burden 15-01 Set of three each (d) Indicating lamps-01 set of three Outgoing (a) MCCBs, 4 POLE, 415 volts grade, 160 Amps rating and ICU=ICS=25 KA rupturning capacity: 02 Nos (b) MCCBs 4 pole, 415 volts grade, 100 Amps rating and ICU=ICS=16 KA rupturning capacity: 01 Nos (c) MCB TPN 6-32 Amps 240 Volt and 10 KA rupturning capacity-01 Nos (for street light) (d) Time switch 0.6 Sec 12 Hrs Single phase, 415 volts AC, 15 Amps, 50Hz, complete with synchronous motor, Contractor-01 Nos(for street light) (e) Complete internal wiring with suitable size (min 2.5 sqmm) of PVC FRLS copper stranded wire
M&L for cable path indicator made out of MS sheet 3 mm thick of size 300x250mm spot welded with angle iron of size 40x40x5 mm thick 750mm long embeded in PCC 1:3:6 type as including painting with two coat of synthetic enameled black paint over a coat of red oxide primer and sign writing with white paint showing grade of HT/LT cable and size complete all as specified and directed.
M&L for single side information board of size 0.90x0.6mm of 2 mm thhick aluminium sheet angle iron frame 35x35x5 mm duly welded with 2 Nos 40mm OD pipe heavy duty stainless 1.8 mtr long with retro reflective high intensity grade complete with writing MES/SL No. make/ Capacity, date of installation, SM No. Area etc including grounting in ground with PCC work in cement mortor 1:2:4 and earth work including taking out old unserviceable existing information board made out from PVC, acrlic sheet of any size complete all as specified and directed.
S&F danger ntoice board of 1.6mm thick mild steel sheet, vitreaous enameled white, white letters, figure and conventional skull and bones in signal red colour fixed with MS clamps, bolts and nuts, for HT of 25 x 20cm size complete all as specified and as directed.
DEMOLITION AND DISMANTLING
Taking down old MCB DB of any way / type and size complete all as specified and as directed.
Taking down old MCCB of any rating complete all as specified and as directed.
Disconnection and taking out old unserviceable submain wiring any description sealing cable end and removing from site complete all as specified and as directed.
Disconnection and taking down old unserviceable AC box and removing from site complete all as specified and as directed.
Taking out old unserviceable LT under ground cable of any size and removing from site complete all as specified and as directed.
Taking down Ceiling/Exhaust fan of any size, sealing cable end, dismantling blades and removing/handing over fan and blades to E/M store complete all as specified and as directed.
ANNPOORNA ENGINEERS & BUILDERS
Baljeet Singh Choudhari
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .