| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.0 LAccepted-AOC GRA 525 KATTIL KUNNATHU HOUSE GOWREESHAPATTOM PATTOM P O TRIVANDRUM 695004 | THIRUVANANTHAPURAM | KERALA | 695001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹71.0 L+₹1,092.92 (0.02%)Rejected-AOC VENUGEETHAM MRA T40 THACHANKARA LANE MARUTHANKUZHY TRIVANDRUM 695030 | THIRUVANANTHAPURAM | KERALA | 695030 | L2 | Rejected-AOC L2 | |
| 3 | L3₹72.4 L+₹1.4 L (1.93%)Rejected-AOC VP 10 323 CHITHRALAYAM NALANKALLU VILAVOORKAL MALAYINKEEZHU THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | KERALA | 695571 | L3 | Rejected-AOC L3 |
Tender Value
₹74.4 L
EMD Value
₹50,000
Closing Date
14 Nov 2023, 3:00 pmClosed
Associate Vice President (HCD)
HLL Lifecare Limited, Central Marketing Office, Chennai. HLL Bhavan, No 26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai-600 100
Civil and Electrical work for Setting up of Integrated Public Health Lab at Thrissur District, Kerala
2023_HCDPS_618288_1
HLL/HCD/IPHL/TRS/23-24
Open Tender
Civil Works - Buildings
Item Rate
300 days
Thrissur
Please refer Tender documents.
12 documents required · 12 mandatory
₹2,950
Yes
₹50,000
Yes
20 Mar 2025
2 Nov 2023
15 Nov 2023
2 Nov 2023
14 Nov 2023
2 Nov 2023
Amount
CIVIL WORKS
DISMANTLING AND DEMOLISHING
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge.
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge.
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm.
EARTHWORK EXCAVATION
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
PLAIN CEMENT CONCRETE
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size.
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, etc. and removal of form for Foundations, footings, bases of columns, etc for mass concrete.
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers.
MASONRY WORK
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand).
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ( 1 cement : 6 fine sand).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand).
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
TILE WORKS
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 800 x 800 mm.
STEEL WORK
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc.
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6 mm for diagonal braces
ROOFING
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing square rain water gutter pipes including jointing.<br>150 mm diameter.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth).
FALSE CEILING
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board.
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
PAINTING
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
SIGNAGES
NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING :Design, Supplying and fixing Name Board as per the technical specifications given -1 Inch GI pipe frame (16Guage) for Frame (Size proportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets (Aluminum Composite Panel) for Box area, 18mm thick Multi wood Lettering for Name Board as approved by<br> Engineer in charge.<br>For Measurement purpose, only area of ACP sheet to be measured.
Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 16" x 10". Complete as per the per the direction of Engineer in charge. <br>
Supplying and fixing 4mm thick Aluminium Composite Panel (ACP) Sheet in Aluminium frame (aluminium frame paid seperately).
ALUMINIUM WORKS
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron).
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron).
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): toughened glass of 6 mm thickness.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper.
Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete.
PLUMBING WORK
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore.
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2.
GENERAL ELECTRICAL WORK
POINT WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C.
CIRCUIT WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 16 sq. mm + 2 X 6 sq. mm earth wire.
PVC CONDUITING
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm.
SWITCH , SOCKET AND BOXES
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet.
DB,ENCLOSURE AND ITS ACCESSORIES
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43).
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43).
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43).
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A, 4P, 100mA.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
PANELS
SERVICE CUBICLE: Fabrication, supply, erection, testing and commissioning of Outdoor type CT metering panel cubicle type, dust and vermin proof, wall mounted, front operated, MV panel board made out of 16 SWG thick CRCA sheet fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components. It consist of 200A, 433V, 50Hz, TPN SDF - 1No RYB phase indicating LED lamps with control fuses and switches - 1No,125A HRC fuse 3nos and provision for 200/5A, CL:0.5, 15VA cast resin CT, provision for kWh meter after testing at Electricity Board TMR Division. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant.
MAIN PANEL: Fabrication, supply, erection, testing and commissioning of floor or wall mounting dust and vermin proof, cubicle type, front operated MV panel board as per IS 8623 - CPRI Certified made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. The panel shall be with Top/bottom entry to receive incoming &amp; outgoing, all opening parts of the panel shall be sealable. This panel should include surge arrester Type 1+2 as per IEC 61643 (IP 20) complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Incomer - 160A 36kA FP Thermal Magnetic based MCCB having isolation duty with 3 O/C and 1 E/F release, isolation duty type 160A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Multifunction meter having multiline LED display with following parameters -Phase wise instantaneous and Average values - Voltage, Current, Power Factor, Phase wise instantaneous and Average values - Active Power, Reactive Power lead and lag, Apparent Power, Import and Export Cumulative values - Active Energy, Reactive Energy lead &amp; lag, Apparent Energy, PF for 3 phases and average, Instantaneous Frequency, Total Harmonics Distortion - Phase wise Voltage and Phase wise Current - 1 Set RYB phase indicating LED lamps with control fuses and switches - 1 set. Class B and Class C/ Class 1 and Class 2 Surge arrestor device with Fuse set - 1 no. Outgoings: 63A 25kA FP MCCB Thermal Magnetic based - 6 nos.
CABLE SUPPLY AND LAYING
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm.
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp.
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp.
Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm.
CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm).
CABLE TRAY
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness.
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness.
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee&;s with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness.
Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness.
EARTHING PROTECTION
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm).
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG).
DG, UPS AND PUMP
Supply installation, testing and commissioning of following three phase to three phase UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with min 20 min backup battery with, input pf>.9, less input current consumption, IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 20kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 15Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.
Providing, Installing, Testing and Commissioning of ‘Silent Type&Diesel Generating set along with having Prime Power Rating of 82.5 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories and Synchronous alternator rated at 82.5 KVA, 415 volts at 1500 RPM, 3phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation, Including CPWD/EI/EB approved AMF panel, Base Frame, Fuel Tank, Battery with leads and other accessories with type competent approved Canopy as a complete set. Contractor has to arrange load test at site or at factory without any additional cost or claim. Including First fill of lube oil and Engine safeties – LLOP, HWT, Initial filling of diesel for standard testing procedure up to 6 hours minimum and 12 hours maximum.
Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust. 4" dia
LIGHT AND FAN FIXTURES
SITC of 4 feet surface mounted batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2400 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 4000K ,6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs.
SITC of recess mounted LED downlighter with a circular form factor with a power consumption of 18 W and a system level lumen output of 2000 lumens and a system level luminous efficacy 110 lm /W. The luminaire shall have a pressure die cast aluminum housing, a polycarbonate diffuser and a sleek design of product height not more than 40 mm. The luminaire shall have a CCT of 6500 K , CRI>80, power factor>0.9 and THD <10 %. The luminaire shall have a non integral LED driver with 50,000 burning hours as per L70B50 criteria, 2.5 kV surge protection. The luminaire shall be EMI/ EMC compliant and should have a Class B serviceability (The driver can be replaced at site level).The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports shall be submitted.
SITC of LED Recess mounted glare free luminaire (2x2) with a nominal system lumen output of 3600 lumens and a minimum system efficacy of 110 lm/W. The luminaire wattage shall not exceed 36 W. The luminaire should have a color temperature of 6500K and CRI>80. Driver of the luminaire shall have THD<10% and PF >0.9. The luminaire must be flicker free with ripple content less than 5 %. The luminaire housing should be made of powder coated metallic CRCA with high efficiency prismatic diffuser so that the UGR should be less than 19. The luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The luminaire must have a life class of 50,000 burning hours as per L70B50 criteria, 4 kV surge protection. The luminaire shall be EMI/ EMC compliant. The luminaire and driver shall be BIS and test certificates of LM79 and LM80 reports shall be submitted (Make: Philips RC380B LED36S-6500 G5 L60W60 PSU OD SG or equivalent).
DISMANTLING
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group A.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group B.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C.
Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
SAFETY MEASURES
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 2.0mm thick, suitable for 1.1 KV , fire retardant,no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply and installation of Co2 Fire Extinguisher (Trolley Mount - Wheel Operating) Type 4.5KG with MS clamps etc. for fixing on wall/wooden partition with 01 year warranty. I.S. No. 13849.
Supply & fixing Laminated drawings of electrical layout, schematic drawing etc. with teakwood frame work on wall as approved by the directorate of electricity.
Supply and fixing of Shock treatment chart duly mounted on a wooden frame with glass on front as required in 2 languages (Hindi & English).
Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.
DOCUMENTATION AND APPROVAL
DOCUMENTATION AND APPROVAL : Charges for Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energization certificates from Electrical Inspectorate & KSEB, obtaining power allocation & power connection etc. for commissioning of the whole installation. All statutory payments will be reimbursed on production of the original receipts. (for modification works).
ELV WORKS
SITC Of 16 Channel Power Supply with Input of 200-240VAC 50-60Hz, 3.5A Max and Output Voltage 12VDC 20A with metal Housing Desktop/Wall Hanging.
SITC Of 16 Channel 5MP DVR Support H.265 Pro+/H.265 Pro/H.265 video compression Support HDTVI/AHD/CVI/CVBS/IP video input Max. 6/12/24 IP cameras input (up to 6 MP) Max. 800 m for 1080p and 1200 m for 720p HDTVI signal transmission Up to 10 TB capacity per HDD Provide power supply to PoC cameras over coaxial cable.
SITC Of 5 MP Dome camera high-performance COMS 2560 × 1944 resolution 3.6 mm, fixed lens with EXIR 2.0, smart IR, up to 20 m IR distance OSD menu, 2D DNR, DWDR 4 in 1 video output (switchable TVI/AHD/CVI/CVBS) IP67 Up the coax (HIKVISION-C).
DC Connector Screw Type
SITC Of BNC Connector Screw Type With Copper Platted
SITC Of up to 4TB Support for up to 16 cameras per drive AllFrame™ technology Up to 16 AI channels for Deep Learning analytics on AI-enabled NVRs (10TB & 12TB capacities) MTBF of up to 1.5 million hours 3-year limited warranty.
SITC OF 6U Rack with PDU unit with Suitable for all type of DVR Box & Double DVR / Network Switch / Server Rack with 4 Power Socket & Cable , Tray (1No) - 1 Cooling Fan Lock & Key.
SITC Of Finolex co-axial 3+1 Copper CCTV Cable with more than 100% conductivity,with low signal loss, sharp picture & clear sound. In-House formulated & manufactured special grade FR PVC compound. (Brand Finolex /V GUARD).
NETWORKING
Supply & fixing of CAT6 (RJ-45) I/O Ports
S I T C Of 24Port 24 Gigabit Ethernet ports for fast network speeds and backwards compatibility with durable metal housing and fanless design for silent operation and performance of IEEE 802.3x Flow Control ,Auto MDI/MDI-X crossover for all ports and Half/full-duplex for Ethernet/Fast Ethernet speeds.
Supply, Installation, Testing & Commissioning of 9U Network Rack with below specifications as minimum and all the necessary accessories: - Lock & Keys - Tray (1 No) - 1 Cooling Fan and Adjustable Shelf - Height - 9U - Dimensions - 13x12x11 cm - Fan Units with 1coolin Fans - PDU 6 point - 1 Nos's - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels"
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable.
EPABX
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..Telephone socket outlet.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm).
EPABX System of 24 lines extendable to 64 lines, No. of Junctions -4, Console Operator-1, ISDN Compatible. Extendable to 64 intercom connection; Internal/External Music on Holding, Operator/Auto-attendant Mode, Remote Programming Day/Night Mode (Manual), Music and Ringing Recordable OGM (outgoing message), Music Duration 20 Seconds Caller ID, Call Transfer, Call Forwarding Manually, Outgoing Call Transfer, Power Failure Transfer, Specific Main Line (CO/Trunk Line) Dialing, Three Way Conference, Do Not Disturb, Auto/Manual Dial-Out Mode Type: Digital, Analog Temperature Range : 0-50 Operating Humidity: 0-95%, Non Condensing.
SITC Of Krone Box 10 Pair
Supply of User Phone- Analog phone
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B.
FIRE FIGHTING
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of heat detector operating at 54ºC / 57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required.
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glassand push button etc. as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.4 Zone
CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
ACCESS CONTROL SYSTEM
"Supply, Laying, Testing & Commissioning of 4 Core Multi Stranded Cable for biometric device to EM Lock & Contact connection with below specifications as minimum and all the necessary accessories - 4 x 1.0 Sqmm - Unarmored - PVC FRLS - Unshielded"
EXIT PUSH BUTTON SWITCH
Supply and installation of U Clamp for Fitting Purpose. Make: ESSL/ALGETEC
Supply and installation of Electromagnetic Lock for Securing Doors during idle time. With L Clamp for Fitting Purpose. Make: ESSL/ALGETEC
Supply and installation of 12V 20 A Power Supply for the device. Make: ERD/PROTEK.
SITC Of Network based Biometric Access Control System with RFID Reader, Fingerprint, LAN, USB and Battery Backup with Pushdata and web based monitoring and management software and External powersupply of 12vDC,1.5 Amps.
PA SYSTEM
Supply, Installation, Testing and Commissioning of professional rack mountable 60 Watt Amplifier to connect MP3 player, FM tuner, SD, USB, 4 Mic / line inputs, 3 Aux Input, 70V/100V, 4-16ohms Output, Individual Volume control & output etc. complete with all standard accessories.Make:Ahuja/Bosch.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Two pair, 2-core, 1.5 sqmm.
PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
PVC CONDUITING
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm.
HVAC WORKS
OUT DOOR UNIT
Supply, installation, testing and commissioning (SITC) of 5.5TR capacity air cooled inverter type Outdoor condensing unit with single/multi scroll compressor as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge R 407C/R410A refrigerant gas, vibration isolator pads and saftey devices like thermal protector, pressure relief valve, over load relays single phase preventor, high-low pressure cut out, suitable for three phase 440V Supply.
AIR HANDLING UNIT
Supply, Installation, Testing and Commissioning of AHUs factory built,2200 CFM, 5.5TR with 75 mm S.P.with HEPA filters, Double skin AHU complete 6 row cooling coil made of 40 mm thick panels consisting of G.I casing of thickness 0.8mm outside and 0.8mm inside Aluminium sheet with factory injected PUF injected between them by injection molding machine, complete with Plug Fan with VFD with minimum 2 bend GSS/ PVC eliminators, cooling coil section with aluminum finned copper tubes filter section with 50 mm thick metal viscous/ washable synthetic type air pre filters, mixing box, VCDs on Fresh air Return air & Supply air opening, TEFC drive motor suitable for 415 ±10% volts, 50Htz 3 phase, A.C supply, drain connection, drain pan, necessary vibration isolation arrangement, expansion valve, drier,AHU Kit,UVC Lamp with airborne inactivation option(Dosage should propose by manufacture), Strip heater with thermostat and RH Sensor (Strip Heater Capacity has to be proposed by manufacture. A separate control panel with thermostat and Humidistat should provide for strip heater. If there is three coils of strip heater one should connect to the thermostat and other two should connect to the humidistat, ie one strip heater should cutoff once the temperature reaches the set point) etc complete as required as per specifications and drawings capacities as given below.AHUs Should be Eurovent/AHRI Certified.
Supply and fixing of electrical panel for AHU & Exhaust Fans with all necessary cables & provision for VFD.
COPPER REFRIGERANT PIPING
Supply, Installation, testing and commissioning of 22.2mm copper pipes for connection for VRV/VRF ODU and IDU with half hard copper tubes (one end expanded type) conforms ASTM: C12200, EN BS:106, ROHS approved and as per manufacturer recommendations, with necessary insulation as recommended. The pipes shall be neatly clamped on wall/cable trays and each supports shall be protected with uPVC pipe of suitable size as required but not less than 150mm length per piece. Maximum spacing between two supports shall be 1500mm if exposed or the pipe shall be concealed on wall including cutting the wall, making good the damages and colour washing etc. as required with necessary Isolating Valves and Driers in Liquid Line as required. [Schematic diagram shall be submitted for Approval before the Installation of Piping].
Supply, Installation, testing and commissioning of 12.7mm copper pipes for connection for VRV/VRF ODU and IDU with half hard copper tubes (one end expanded type) conforms ASTM: C12200, EN BS:106, ROHS approved and as per manufacturer recommendations, with necessary insulation as recommended. The pipes shall be neatly clamped on wall/cable trays and each supports shall be protected with uPVC pipe of suitable size as required but not less than 150mm length per piece. Maximum spacing between two supports shall be 1500mm if exposed or the pipe shall be concealed on wall including cutting the wall, making good the damages and colour washing etc. as required with necessary Isolating Valves and Driers in Liquid Line as required. [Schematic diagram shall be submitted for Approval before the Installation of Piping].
EXHAUST SYSTEM
Supply installation testing and commissioning of Insulated inline Circular/ Cabinet fan of 800cfm capacity & 50mmwg external static pressure.
DUCTING
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet.
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet.
Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrile rubber insulation - 25 mm.
Supply and fixing of acoustic insulation on plenum and initial portion of the duct upto3 mtrs or as suggested from the Ductable units mouth with open cell type 10 mm thick nitrile sheet, with density 140- 180kg/m3 and anti Microbial Properties fixed with manufacturer recommended adhesive and tightened with necessary accessories etc. as required.
Fusible link type Fire Damper of Galvanized Steel Sheet construction, 16G GI casing and 16G GI blades 150 mm wide, 3 V type in 18G 600 mm sleeve complete with chrome plated spindles ,self lubricating bushes,120 minutes fire rating as per UL-555.
Manufacturing and fixing- hanging of Fire retardant flexible Canvass connection at outlet of each Ducted IDU with zipper to facilitate temperature measurement. Rates is per Machine, not per Outlet.
DRAIN WATER PIPING
Supply and fixing in position of 25mm condensate drain water pipe from indoor unit drain to the floor trap piping with 19mm thick nitrile rubber insulation and with necessary fittings like elbows, tees and reducers etc. Openings as good as same.
MAGNEHELIC GAUGE
Magnehelic Gauge of Dial size 4" and Pressure Range of -50 to 50 Pa.
HEPA FILTER
Supply, Installation, Testing and Commissioning of HEPA Filter,Grade H-14, Air Flow Capacity 800 CFM @ 250 Pa minimum allowable initial pressure drop. With differential pressure gauge to monitor the pressure drop across the filter.
REMOTE CONTROLLER
Supply installation testing and commissioning of wired Remote Controller for controlling Indoor Units with it all accessories.
MS STAND FOR ODU
Supply and installation of 5.5TR ODU support for mounting the condenser units as required by erecting suitable structure made up of minimum MS 50x50x6 'L’ sections and 75x40 Channel, suitable cross section neatly painted with epoxy based primer and two coats of epoxy paint of approved colour with placing vibration isolators of 12 mm thick ribbed rubber pads. [GA drawings shall be submitted for approval].
COMMUNICATION CABLE
Supply,installation,testing and commissioning of control cum transmission wiring of 6Cx4Sqmm with suitable gauge wire in suitable PVC conduits between indoor and out door unit.
MASTERCELL TELECOM SERVICES (P) LTD
CHITHRANI TRADERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .