| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹37.5 L+₹1.1 L (3.14%)Rejected-AOC 19 PAOTA C IIIRD ROAD JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹39.9 L+₹3.6 L (9.86%)Rejected-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-AOC Rejected being higher bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Jan 2025, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
CERTAIN REPAIR TO INTERNAL ELECTRIFICATION ACs AND MISC BR REPAIR WORK TO THE BLDGS AT WEAPON STORAGE AREA AT AFS JODHPUR
2024_MES_690667_1
8695/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹80,000
Yes
12 Feb 2025
28 Dec 2024
25 Jan 2025
28 Dec 2024
23 Jan 2025
11 Jan 2025
Amount
Taking down plastering in cement mortar in any position including removal of debris out side MOD Land complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and making good but portion ordered to be dismantled including removal of debris out side MOD Land complete all as specified and directed by Engr-in Charge.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in sub base complete all as specified and as directed by the Engr-in-charge.
M&L for 75 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregates as in flooring complete all as specified and as directed.
M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 Grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including taking out old broken unserviseable tiles out of MOD land, complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregates as in flooring complete all as specified and as directed.
M&L for factory made vitrified heavy duty parking tiles coloured, matt finish, unglazed and unpolished of size 300x300x10mm thick including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed by Engr-in-Charge.
M&L for precast cement concrete 1:3:6 type C1 (Using 20 mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified including demolition of old existing masonary complete all as specified and directed by the Engr-in - Charge.
M&L for rendering 10mm thick 1:6 on fair faces of brick work or concrete surfaces finised even and smooth (without using extra cement) complete all as specifed and directed.
M&L for rendering 15mm thick 1:4 on fair faces of brick work or concrete surfaces finised even and smooth (without using extra cement) complete all as specifed and directed.
M&L for preparation of new surfaces of wall and applying two coat of oil bound distemper over and including a coat of primer over a coat of white putty in patches as required complete all as specified and directed.
M&L for applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50gm/lit and UV resistance as per IS: 15489:2004 , Alkali & fungal resistance , dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90lit /10sqm over new surfaces completed all as specified and directed.
S&F in repair for Anodised aluminium snap grid frame work for false ceiling including wall side angle 24x 24x 43mm , Main Tee 24x35x0.35mm and Cross Tee 24 x 25x 0.30mm having integral splices at both ends for interlocking complete with suitable hanging arrangement of metallic fasteners, necessary fittings, screws, GI wire , holding cleats etc complete all as specified and directed.
S&F 8 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid for exposed metal frame ceiling incl dismantling of old ceiling boards of any description or any thickness and preparation of surface and applying two coats of oil bound distemper on new or previously untreated surfaces of ceiling complete all as specified and directed. (Note - Frame work for ceiling shall be measured and paid separately.)
M&L for welding in repairs of metal steel plates/ section /angles thickness exc 9mm but n exc 20mm complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
M&L for preparation of new concrete surfaces of any description over 10cm in width or girth not otherwise discribed, and applying two coats of synthetic enamel paint (ordinary tint) including one coat of primer complete all as specified and as directed.
S&F in repair Galvanised 2 Strand ,steel barbared wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts ,including ,securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed. (Note - Each line wire to be measured.)
M&L for restraining, resecuring including making good galvanised 2 strand, steel barbered wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc as complete all as specified and directed.
Supply anf fix in repair mild steel galvanised steel punched type concertina coil of 1050mm dia (dia of coil when unstreched) and fixed to angle iron with 3.15mm dia GI wire complete all as specified and directed.
M&L for repair to pot holes not exc 1sqm each including sweeping free from dust and mud, or water, scoring sunken surface in roads, path etc cutting around edges to at least 25mm in depth making good by applying tack coat with VG-10 gde paving bitumen at 5 kg per 10 sqm, putting in premix as specified for bituminous carpet (2 cm thick) well rammed and sealed with premixed sand seal coat (6.8 kg of binder with 0.06 cum of sand), again well rammed (including suppy of premix binder and sand) depth of pot holes n exc 30mm complete all as specified and directed.
M&L for applying evenly a priming /tack coat with bitumin emulsion pressure distributer with rapid setting bitumen emulsion on bituminous surface @0.25kg/sqm including preparing the surface & cleaning with mechanical brooming complete all as specified and as directed.
M&L bituminous premix semi dense asphaltic concrete 30 mm average consolidated thickness with 5.5% binder content by weight of total mix with bitumen of grade VG-30 (conforming to IS-73-2006) laid/ rolled and compacted to required gradient and camber with 8 to 10 tonne complete all as specified and directed by Engr-in-Charge.
M&L for painting lines, dashes, arrows, letters, etc., on roads, pavements and the like exc. 10 cm wide with Retro-Reflective Thermoplastic road marking paint, white or golden yellow, conforming to MoRT&H specification all as per manufacturer's specification and as directed by EIC.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit compressor 1.5 Tonne capacity, single phase, 230 volt of including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage, rectification and supply & fixing of new compressor of same capacity and make, inverter/ non inverter type including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit compressor 2.0 Tonne capacity, single phase, 230 volt of including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure testing, leakage, rectification and supply & fixing of new compressor of same capacity and make, inverter/ non inverter type including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for WATER JET servicing of AC's of 1.5/2.0 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover, outdoor top cover from existing location, cleaning of cooling coil, condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
Supply & fixing in repairs running capacitor of capacity 2.5 MFD, 230 volts, 50 HZ suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 4 MFD, 230 volts, 50 Hz.suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 6 MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 45MFD,230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 50 MFD 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Starting capacitor of capacity 80-100 MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condensing fan motor of capacity 1.5/2.0 Tonne for split type AC's single phase, AC 230 volts, 50 Hz or DC motor of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs indoor blower motor of capacity 1.5/2.0Tonne for split type AC's single phase, AC 230 volts, 50 Hz or DC motor of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Blower suitable (for indoor unit) of split type AC's cap 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs fan blades (ISI Marked) of suitable size for outdoor unit of 1.5/2.0 Tonne Split type AC's complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs/ replacement PCB control card suitable for AC indoor unit 1.5/2.0 Tonne capacity split type AC, single phase of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs/ replacement PCB control card suitable for DC indoor unit 1.5/2.0TR capacity invertor split type AC, single phase of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs/ replacement PCB control card suitable Outdoor unit for invertor type split AC's capacity 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply only in replacement of Remote suitable for 1.5/2.0 Tonne capacity split AC of original make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condenser coil for split AC 1.5/2.0 Tonne capacity of any make including charging of gas R-22/R407C complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper cooling coil for split type AC 1.5/2.0 ton capacity of any make including charging of gas R-22/R407C complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs water tray (ISI Marked) for Indoor unit of split AC of any capacity and make AC as approved by Engineer-in-Charge.
Supply & fixing in repairs of relay of split type AC of any make and any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs single pole contactor suitable for split type AC capacity 1.5/2.0 Ton complete all as specified & directed by the Engineer-in-Charge.
Material & labour for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC's/split type AC's of 1.5/2.0 ton and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering with and including charging the gas and testing the AC to the entire satisfaction of Engineer-in-Charge.
M&L for AC water leakage,opening of indoor unit of AC, removing of drain tray, cleaning of drain tray, clear all blockage, make proper insulation to copper pipe and cover these pipe with non-adhesive tape complete and fix the unit on wall and testing complete all as specified and directed.
Supply, laying and commissioning of cable in replacement PVC sheathed cable with multistranded copper conductor of size 2.5 sqmm 3 core complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper tube (ISI Marked) of size ⅝” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper tube (ISI Marked) of size ¼” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for pipe insulation thickness 10mm of size ⅝" dia of split type AC's any capacity complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for pipe insulation thickness 10mm of size¼" dia of split type AC's any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs flexible drain pipe ( PVC BRAIDED hose pipe) of size 15 mm dia, for split type AC any capacity and any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs floor mounted bracket AC stand certified special coated super 50cm x 8 cm shelf bracket suitable for 1.5/2.0 tonne outdoor unit capacity complete all as specified & directed by the Engineer-in-Charge.
Material & labour for sub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 6 Sqmm 1100 volt grade and one run of 6 Sqmm single core as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, concealed in wall (including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.) including taking out / down the existing unserviceable sub main wiring with conduit complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Supply and draw submain wiring with two single core 4 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unseathed conductor drawn into steel conduit and all necessary fittings including 4 sqmm multi stranded FRLS PVC insulated copper wire for earth continuty conductor drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm connected to common earth dully complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed.
Supply & fixing in repairs sheet metal enclosure SPN with two pin and earth plug socket with & including 25 Amps MCB 'C' curve single pole 240 Volt AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB SP 25 Amp ‘C’ curve type, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repair MCB SPN 25 Amp ‘C’ curve type, 230 volts, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement display card of Indoor unit of Split AC capacity 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repair to replacement of burnt out indoor unit of split AC carefully removing connection of AC and fix indoor unit of same capacity, make proper connection complete with remote of Split AC capacity 1.5/2.0 Tonne complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs L & key valve (ISI Marked) of size 5/8" or 1/4" for condenser unit split type AC 1.5/2.0 Ton , proper leak check shall be carried after replacement of valve complete all as specified & directed by the Engineer-in-Charge.
Material & labour for filling of Refrigerant R-22/ R-410a/R-32 or any refrigerant suitable for AC complete all as specified & directed by the Engineer-in-Charge.
S&F LED Flood light 100 watt 230 Volts AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant having minimum lumens 125 lm per watt, power factor > 0.95, THD <10,CRI >80 and minimum life 50,000 Hr complete with driver and lamp and back stand complete all as specified & directed.
S&F LED Flood light 170/150 watt 230 Volts AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant having minimum lumens 135 lm per watt, power factor > 0.95, THD <15,CRI >80 and minimum life 50,000 Hr complete with driver and lamp and back stand complete all as specified & directed.
Supply and fix flood light fittings LED flame proof, water proof 100W IP 65, in cast aluminium alloy LM6 construction with toughnened glass including stain steel chain/fixing arrangement for mounting the lights in hanger roof for prevention of light to fall down with 2.5 sqmm FRLS 1100 Volt grade three core multi stranded copper conductor for connection all as specified and directed.
Material & labour for sub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 2.5 Sqmm 1100 volt grade and one run of 2.5 Sqmm single core as earth lead drawn through in and including steel surface conduit of size 20 mm dia including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and steel conduit shall be measured & paid for as one length.
Supply and fix flame proof switch rotary type with termnination box in LM6, 16 A,230V, single pole.Complete all as specified and directed by Engineer-in-Charge.
S&F flame proof weather proof MCB DB SPN 8 way including MCB SPN 40 Amps-01, MCB SP 6-32 Amps-5 of Make:- Sudhir or Equivalent of Shyam/Bliga as approved by GE. NOTE : MCB shall be 10 KA repturing capacity and of C series.
M&L for earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal grounf level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, precast RCC 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm mmbore medium grade GI protection pipe, test point etc complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply and fixing LED light fitting 2X16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M&L in replacement of 35 sqmm multistranded flexible copper conductor with suitable mounting accessoreis, the mounting clamp should be non conductive metarial used in earthing complete all as specified and directed.
Supply & fix in replacement of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw required with all accessories complete all as specified and directed.
Supply & fix in replacement of single pointed air termination aluminium rod 12mm dia, 300 mm long as directed complete all as specified and directed.
Supply and fix in replacement of GI pipe medium grade for air termination rod of size 40 mm dia upto 3.0 mtr long complete all as specified and directed.
Taking down existing aluminium strips and S&F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
Taking down existing copper strips S&F copper strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
M&L for PCC block of size 150x150x300mm made up of PCC 1:2:4 type B-2 Blocks for fixing/ mounting of running earthing conductor including laying in CM 1:4 complete all as specified and directed.
M&L in replacment of kota stone earth pit cover(2x2 feet) complete all as specified and directed.
Supply and lay of pipe galvanized, “Medium class”, including fittings 15 mm (1/2”) dia in trenches or laid on walls/ under floors complete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of 15 mm (1/2”) dia complete all as specified and directed.
S&F Self closing tap of cast iron or malleable cast iron, Galvanised, screwed for iron pipe and fixed 15mm complete all as specified and directed.
M&L for cutting of existing steel tubing for alteration or additions of size 15 mm complete all as specified and directed.
S&F in replacement of Seprator U type made of porcelene uses for earth strip mounting with all nut bolts and connecting accessories complete all as specified and directed.
M&L in replacement of PVC/ rubber pipe/ sleeve for protection of Earth strip and insulation purpose complete all as specified and directed.
M&L for Potassium Nitrate (commercial name kalmi shora) for improvement of earthing resistence complete all as specified and directed.
Om Trading Corporation (BID ID -3215251)
M/S KAUTILYA GARG (BID ID -3222436)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .