Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.7 L+₹10,100 (0.51%)Rejected-AOC SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.8 L+₹3.1 L (15.9%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.4 L+₹3.7 L (19.1%)Rejected-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L4 | Rejected-AOC L4 | |
| 5 | L5₹27.8 L+₹8.1 L (41.3%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
10 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KHUMBATHANG
GE KHUMBATHANG
GE/KHU-24/2021-22 COMPREHENSIVE MAINTENANCE OF CHS AND ALLIED SERVICES AT KHUMBATHANG IN THE AOR OF AGE E/M KHUMBATHANG UNDER GE KHUMBATHANG
2021_MES_474643_2
GE/KHU-24/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE KHUMBATHANG
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KHUMBATHANG
₹50,000
3 Dec 2021
27 Oct 2021
11 Nov 2021
27 Oct 2021
10 Nov 2021
3 Nov 2021
60 days
Amount
M&L for detection of leakage, rectification of leakage by means of water method, making the system leak proof and serviceable complete all as specified and directed.
M&L for removing / opening of electric boiler control panel for checking serviceable state of control wiring and switches which includes replacement of minor parts (control wiring and other necessary items for making the panel serviceable) complete all as specified and directed.
Dismantling of mono block electric motor set of capacity 3 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC complete all as specified and directed. ( Note : Transportation charge of motor from site to workshop and back is deemed to be included in the item rate) .
Dismantling of mono block electric motor set of capacity 5 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC complete all as specified and directed. ( Note : Transportation charge of motor from site to workshop and back is deemed to be included in the item rate) .
M&L for replacement of Unserviceable diesel fired burner assembly of heat output capacity 25000Kcal/hr for standalone CHS Complete all as specified and directed. Make Alfa Therm Model No AH 2500.
M&L for replacement of Unserviceable diesel fired burner assembly of heat output capacity 50000Kcal/hr for standalone CHS Complete all as specified and directed. Make Alfa Therm Model No AH 2500
Supply only glycol / coolant alongwith the necessary additives and inhibitor in cognition and supplied in barells complete all as specified and directed.
S&F Heater bank in repair of capacity 25 KW for electric based central heating system all as specified and directed incl taking down old one complete all as specified and directed
S&F Heater bank in repair of capacity 7 KW for electric based central heating system all as specified and directed incl taking down old one complete all as specified and directed
S&F Heater bank of capicity 5 KW for electric based heating incl thermostat of suitable capacity and other connected accessories incl taking down old one complete all as specified and directed
S&F in repair of monoblock pump of 1 HP with all accessories complete all as specified and directed.
S&F in repair Burner fuel pipes incl taking down old one complete all as specified and directed.
S&F in repair oil filter (super fine glass type) of suitable for burner 1 lac K/C as per requirement at site incl taking down old one complete all as specified and directed
M&Labour for complete Decarbonising of boilers including replacement of damaged refractory complete all as specified and directed
S&F in repair pressure switch incl taking down old one complete all as specified and directed.
M&L for Repairing to body leakage of electric Hamam of capacity 45 Ltr ,steel body rectangular/round type with thermostates and auto cut and change of burnt heating element complete all as specified and directed.
S&F in repair flexible PVC all weather/ Crack proof pipe of size 20 mm dia complete all as specified and directed.
M&L for Repairing to body leakage of electric Hamam of capacity 25 Ltr ,steel body rectangular/round type with thermostates and auto cut and change of burnt heating element complete all as specified and directed.
M&L for Replacement of damaged nitril insulation of 19 mm thick over PPR pipes of 32 mm size as required at site complete all as specified and directed.
M&L for Replacement of damaged abstract rope insulation of 10 mm thick over Duct (outside) of CHS 200x200 mm size as required at site complete all as specified and directed.
M&L for Replacement of damaged Chimney for 25000 K/cal Model AH-25 AHU unit of make alfa Therm length as required at site complete all as specified and directed.
M&L for Replacement of damaged aluminium cladding over any size pipe as required at site complete all as specified and directed.
M&L only for opening the Oil based boiler, dismantaling the accessories and cleaning the boiler including replacement of necessary minor accesries as per site requirement complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent R-134a, brazing and bring to be serviceable condition and testing suitable for 500 ltr Deep Freezer complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent R-134a, brazing and bring to be serviceable condition and testing suitable for 300 ltr Deep Freezer complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent R-134a, brazing and bring to be serviceable condition and testing suitable for 200 ltr Deep Freezer complete all as specified and directed.
S&F in repair contactor A-26-30-10, 13 NO AC 3 phase complete all as specified and directed. Make - L &T /ABB/Schnider
S&F in repair contactor MNX 9, AC 3phase complete all as specified and directed. Make : L &T /ABB/Schnider
Material & Labour for Descaling of radiator panel associated with CHS installed at signal and A Mess complete all as specified and directed.
Material & Labour for servicing of fan coil unit of indoor units, removing dust / other remains with suitable liquid complete all as specified and directed.
S&F in replacement of wall mounted fan coil unit of capacity 1.5 TR (4500 K Cal/Hrs 600 Cfm) complete all as specified and directed.
S&F in replacement of wall mounted fan coil unit of capacity 1.0 TR (3000 K Cal/Hrs 600 Cfm) complete all as specified and directed.
S&F in replacement of Sequence control of boiler complete all as specified and directed.
S&F in replacement of iginition transformer of boiler complete all as specified and directed.
S&F in replacement of Nozzle 60 degree 2GPH of boiler complete all as specified and directed.
S&F in replacement of ignition Electrode complete all as specified and directed.
M&L for replacement of Fuel pump suitable for 1 lac kilo calories burner assembly complete all as specified and directed.
Supply, installation, testing and commissioning of wall mounted type heco panel of size 600mm x 300mm x 18mm or rating of 65W each, complete, all as specified and directed incl taking down old one. Make of Panel : Ecco, Menos or equivalent
S&F Heat Pillar Rod of capacity 750 Watts complete all as specified and directed.
S&F in replacement of heating element AC 230 volt, triangle/round type of rating 1500 watt suitable for geyser/Hamam as per sample, complete all as specified and directed.
Supply only heating element AC 230 volt, triangle/round type of rating 2000 watt suitable for geyser/Hamam as per sample ,complete all as specified and directed.
M&L for repair of Water heater storage type, electric based ,capacity 50 litres rates including change of thermostate, stainless steel tank, heating element complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC insulated stranded copper conductor size 2.5 Sqmm 2 core for connection anti freezing tracer complete all as specified and directed.
M&L for repair of Water heater storage type, electric based ,capacity 25 litres rates including change of thermostate, stainless steel tank, heating element complete all as specified and directed by Engr-in-Charge.
S & F in repair of motor of FCU1.5 TR/1.0 TR complete all as speciifed and directed.
M&L for repairing of metal heat pillar of capacity 2x750 KW including necessary wire connection complete all as specified and directed.
S&F in repair single phase earth metal plug socket incl 32 A MCB C series complete all as specified and directed.
M & L for replacement of submain wiring 2 core 4.0 sqmm phase and neutral incl earth wire of 2.5 sqmm in existing conduit and PVC batten complete all as speciifed and directed.Note: 2 runs of 4.0 sqmm phase and neutral and 01 core of 2.5 sqmm as earth wire will be treated as one unit.
S & F in replacement of existing UNSV MCCB 4P 100 A 25 KA with thermal and magnetic release including providing suitable thimble complete all as speciifed and directed.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 63 KW electric boiler complete all as specified and directed.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 45 KW electric boiler complete all as specified and directed.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 75 KW electric boiler complete all as specified and directed.
Supply & Fixing in repair Ball valve of size 20 mm dia complete all as specified
M&L for replacement of damaged relay 16 Amps MN-2 Complete all as specified
Deduct Credit for Demolished/Dismantled material Rs (-) 1,14,450.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/S SUN RISE BUILDERS
M/S Web Company
national engineering
osho traders
SUMEET TRADING CORPORATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .