Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.5 L+₹46,429 (2.32%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹23.7 L+₹3.7 L (18.6%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹25.0 L+₹5.0 L (24.8%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹25.0 L+₹5.0 L (25.0%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 May 2022, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
REPAIR/ REPLACEMENT AND MAINTENANCE OF SECURITY/ STREET LIGHTS, AVIATION/ WATCH TOWER FLOOD LIGHTS, POST TOP LANTERNS AND CONNECTED SERVICES UNDER GE (I) NAVY JAMNAGAR
2022_MES_517535_2
8581
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE (I) Navy Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹50,000
Yes
13 Feb 2023
12 May 2022
20 May 2022
12 May 2022
18 May 2022
13 May 2022
12 May 2022 - 12 May 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of pipe line etc and getting out in any type of soil (i.e.soft/ loose or hard/ dense soil) complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L for PCC 1:4:8, type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete for steel pole complete all as specified.
M&L for PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork complete all as specified.
M&L for TMT bars/ Mild steel angle cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint (for supporting frame for flood light fitting) complete all as specified.
M&L street light bracket made from MS tubing as required size at site, cut to length, bend to shape required and suitable for existing street light pole and fixing the bracket to pole with MS flat and nuts and bolts and finally painting te exposed steel surface with two coats of first quality enamled paint over a coat of zinc chromate primer complete all as directed..(Note : Quoted rate is deemed to be inclusive of painting)
Taking down street light / Flood light / Post Top fittings of any capacity from 40-200 W for repair/ replacement of burnt/ worn out accessories and refixing the same after all repair work complete all as directed. Note: Spares shall be measured and paid separately.
Supply only LED driver of 40/45 W LED Street light/ Post Top/ Flood Light fitting. Make: Osram/ Wipro/ Bajaj BGD 40 1050 5Y/ Jaquar WHT-JQMSRT01S045/ Havells.
Supply only LED driver of 72 W LED Street light/ flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JQMSRT01S072/ Havells.
Supply only LED driver of 90 W LED Street light/ flood light fitting. Make: Osram/ Wipro LG56-036-002-1540/ Bajaj/ Jaquar ZDR-WHT-JQMSRT01S090/ Havells.
Supply only LED driver of 120 W LED flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JBIFLDSLM120/ Havells.
Supply only LED driver of 150 W LED flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JBIFLDSLM150/ Havells.
Supply only LED driver of 8 W LED Bollard light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar/ Havells.
S&F in repairs 3 core, 2.5 sqmm PVC insulated sheathed multistranded flexible copper conductor cable drawn through existing conduit pipe from junction box to fitting complete all as directed. Make: Havells / Finolex / Polycab
S&F in repairs junction box made from SMC/FRP sheet readymade of size 300x200x100 mm having 100 A capacity including RYB and neutral with aluminum busbar with 4 way connector, MCB SP 6 Amp 10 kA 240 V - 01 No. fixed to pole/wall with MS clamp 25x5 mm and necessary painting to MS clamp complete all as directed.
S&F in repair MCB TPN 32 Amp 10 kA, 415 V, 50 Hz, AC supply complete. Make: Legrand Cat No. 4086 80 / Havells / L&T / ABB
S&F in repair MCB TPN 63 Amp 10 kA, 415 V, 50 Hz, AC supply complete. Make: Legrand Cat No. 4086 83 / Havells / L&T / ABB
S&F in repair MCB SP 6 Amp 10 kA, 240 V, 50 Hz, AC supply complete. Make: Legrand Cat No. 4085 87 / Havells / L&T / ABB
Taking down existing post top lantern of any description and S&F new 40W IP 65 decorative LED outdoor post top lighting fixture with powder coated pressure die cast aluminum housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimun Lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket fixed as per manufacturers instructions and making neccessary electrical connections and testing on completion complete all as directed. Make : Bajaj BGCT 40W WW LED or Schreder 40W or Panasonic APT010404.
Taking down existing street light fittings/ fixtures and Supply, fix, test and commissioning new 90 Watt LED street light fittings, High Efficiency IP 66 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of he system shall be greater than 9000 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing to existing bracket including nut bolts, 2.5 sqmm, 3 core cable and electrically connected to the existing system complete all as directed. Make: Bajaj Cat No. BRTFG 90W LED / Havells Cat No. ENDURA CITY LINER NEO SL 90W LED 757 SASYBOTG / Jaquar Cat No. LSRT01S090XC/ Crompton / Schreder
Taking down existing flood lights fittings / fixtures and S&F new 150 W LED flood lighting fittings with high pressure die cast housing with lens IP 65 protection, powder coated CCT(k) 6000, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system complete all as directed. Make: Jaquar LFLDSLM150XC or equivalent in Havells / Bajaj / Crompton / Schreder.
Taking down existing flood lights fittings / fixtures and S&F new 200 W LED flood lighting fittings with high pressure die cast housing with lens IP 65 protection, powder coated CCT(k) 6000, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system complete all as directed. Make: Jaquar LFLDSLM200XC or equivalent in Havells / Bajaj / Crompton / Schreder.
S&F in repair 8 W LED bollard IP-54 rated with in built LED, made in die cast aluminium housing and frosted poly carbonate diffuser, CCT(K) 3000 complete with all standard accessories fixed as per manufacturers instructions including testing on completion complete all as directed. Make : Jaquar Cat No LBLD03R108 XW or equivalent in Wipro/ Bajaj/ Philips/ Havells/ Crompton Greaves.
Dismantling and taking down existing deteriote PC (concrete) poles and S&F new 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of diamensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate diamensions 200x200x12 mm, foundation bolt size 4 nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with MCB SP 6 A-1 No., MCB TP 32 A 10 kA-01 No., Neutral connector - 63 A Cap-01 No. complete all as specified and as directed. Make: Bajaj BOP-6030 or equivalent in Philips / Havells / Wipro. Note: Earth work and PCC foundation shall be measured separately
S&F in repair 3 pole power contactor ML 3 including necessary connections for incomming and outgoing. Make : L&T Cat No. SS90721 / Philips / Legrand / C&S
S&F Astro digital time switch, 1 channel mounting in existing panel, suitable for switching ON/OFF light and other electric devices according to the rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/or fixed preset times and also suitable for daily astronomical calculation of the sunrise/sunset time based on the entered location or location coordinate complete all as directed. Make: Legrand cat No. 4126 54 or equivalent in L&T / Siemens / Schneider / C&S
M&L preparing PCC pole by cleaning, removing creeper etc and painting with two coats of antifungal exterior emulsion weather proof paint (Apex) of approved colour shed and writing Pole numbers with white paint having black background enamel paint suitable for outdoor including painting GI bracket & clamps of street light fitting fixed on pole with two coats of synthentic enamel paint over one coat of red oxide primer complete all as directed.
M&L preparing steel pole (upto 6mtrs height) suface by cleaning, removing creeper etc and painting with two coats of Aluminium paint over one coat of zinc chromate primer complete all as directed.
Taking up existing cable lay down in any descrition and Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sq.mm, 4 core complete all as directed.
All as per item No. 30 here in above, but cross-sectional area 10 Sqmm, 4 core.
Supply and lay 32 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ cm2, laid in trenches as cable protection with all fittings complete all as specified.
S&F 50 mm bore GI tubing light grade including necessary fittings such as bend, tee, elbow etc complete laid in trenches/ fixed on walls complete all as directed.
S&F 40 mm bore GI tubing light grade including necessary fittings such as bend, tee, elbow etc complete in laid in trenches/ fixed on walls complete all as directed. (Note for all items : (i) The contractor has to check the fittings/ fixtures and wiring as per the complaints given bt the concerned JE E/M /Engineer -in-charge . Spares required to be replaced sahll be measured under respective items in this Schedule for which no extra payment on account of man power will be paid fro tyhe same. Contractor has to provide minimum one tradesman having good experience in relevant field (one labour) . Contractor has to make arrangement for collection of complaint slip from MES service center daily for carrying out the complaints & simuntaniously intimate JE E/M once the complaint is resolved , all complaints to be resolved the same day . (II) In case Contractor fails to resolve the complaint / attend the same a penalty of Rs 100/- per day shall be deducted until the same is attended/ resolved).
M/s Balaji Enterprise
J J ENTERPRISE
M/s. Vimal Enterprise
M/s Jagdish Machinery Stores
1R K Traders
suvidhiconstruction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .