Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.5 L+₹27,808.37 (0.77%)Rejected-Finance VILL BHAISORA POST CHINHAT DISTT LUCKNOW UP | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹38.1 L+₹1.9 L (5.34%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹39.2 L+₹3.0 L (8.34%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹40.3 L+₹4.1 L (11.3%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹47.1 L
EMD Value
₹94,216
Closing Date
26 Apr 2025, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
SPL REPAIR TO BLDG NO P 165 (08 DWELLING UNITS) ORs MD ACCN OF ABOD IN A A BANAR UNDER GE BANAR
2025_MES_703009_1
8824/61/E8
Open Tender
Civil Works
Item Rate
180 days
BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Banar
₹94,216
Yes
12 Jun 2025
29 Mar 2025
3 May 2025
29 Mar 2025
26 Apr 2025
12 Apr 2025
Amount
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M&L for 15mm thick rendering in CM 1:6 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified.
M&L for two coats of oil bound distemper on newly plastered walls over a one coat of 1mm thick JK/Birla wall putty over plastered surface to prepare the surface even and smooth and priming plastered and other surfaces with alkali resistant priming paint including preparation of surfaces all complete all as specified.
M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper over a one coat of 1mm thick JK/Birla wall putty over existing/ plastered surface to prepare the surface even and smooth complete all as specified.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified.
M&L for preparation of old plastered or unplastered surfaces of walls and applying two coats of white wash complete all as specified.
M&L for 10 mm thick rendering in CM 1:3 on concrete surface as in ceiling and finishing the surface even and smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash complete all as specified.
M&L for preparation of old plastered or unplastered surfaces of ceilings and applying two coats of white wash complete all as specified.
Material and labour for 15mm thick rendering in two layer, 5mm thick rendering in CM 1:4 mixed with WPC over 10mm thick rendering in CM 1:4 on stone masonry/concrete surfaces/roof projections/chajjas upto the height 7 Mtr complete all as specified. Note:- WPC shall be measured and paid separately.
Material and labour for 15mm thick rendering in CM 1:4 mixed with WPC on stone masonry/concrete surfaces and Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mitres and stopped ends etc complete upto the height 7 Mtr complete all as specified. Note:- WPC shall be measured and paid separately.
Material and labour for 15mm thick rendering in CM 1:4 mixed with WPC on stone masonry/concrete surfaces and Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work n exc 15 cm in width or girth; including cutting to edges, all mitres and stopped ends etc upto the height 7 Mtr complete all as specified. Note:- WPC shall be measured and paid separately.
Supply only integral water proofing compound complete all as specified.
Material and labour for preparation of newly plastered surface of walls and applying two coats of cement base paint over one coat of alkali resistance primer complete all as specified.
M&L for two coats of cement base paint on old plastered/pointed surfaces of walls including necessary preparation of surfaces complete all as specified.
Raking out joints/pointing to squarred rubble masonry, coursed or uncoursed built in cement mortar complete all as specified.
M&L for keyed pointing to stone masonry surface in CM 1:4 complete all as specified.
Demolition of Brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
M&L for square rubble walling, Jodhpur type, regular coursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified.
All as per item No. 19.00 above but except stone.
Extra over on stone walling for hammer dressing to face stone with maximum depression on face from straight edge n.exc 20 mm and dressing faces beds and joints as specified to square rubble walling regular course Jodhpur type complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding (including not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for coloured Glazed ceramic tiles in vertical surface 350x250x7mm/450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles in vertical surface including 10mm thick rendering in CM 1:4 complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing from site complete all as specified.
M&L for 25mm thick PCC 1:2:4, Type B-0 using 12.50mm graded aggregates as in base concrete to floor finish complete all as specified.
M&L for coloured non-skid ceramic tiles 7 to 8mm thick (square/rectangular), coloured tiles, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floorts etc, set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified.
All as per item No 26 above but as in skirting incl 10mm thick rendering in CM 1:4 complete all as specified.
M&L for coloured non-skid ceramic tiles 7 to 8mm thick (square/rectangular), coloured tiles, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floorts etc, set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified.
M&L 18/20mm thick any shade marble (Green marble) slab in cooking platform set in CM 1:4 incl pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade 15 mm thick screed bed in CM 1:6 complete all as specified.
M&L 18-20 mm thick Red Granite work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including moulding (U type) on edges in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
M&L for 20-25mm thick machine cut kota stone flooring over and including 20mm thick screed bed CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing complete all as specified.
Taking down chowkats or frames with shutters (w/o taking off shutters) n exc 1.5 sqm each complete all as specified.
Taking down chowkats or frames with shutters (w/o taking off shutters) exc 1.5 Sqm but n exc 4 Sqm each complete all as specified.
S&F winodws/ventilators (ECO-4000 series double rebate) fabricated from roll framed section made of galvanised steel colour coated/powder coated (Base steel as per IS 513 'D' quality galvanised as per IS 277 with zinc of 120gms/sqmtr) with total coated thickness of 0.60mm, with or without cooler opening. Note. Paint Specification : Coated sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with polyester up to 50-60 microns thick. Dimenstions of Sections: Sections for frame should be of 72mmx55mm, section for mullion should be of 72mmx50mm, sections for shutter frame should be of 47mmx20mm, sections for fixed glass bead should be of 12mmx12mm, and section for fly mesh should be of 40mmx20mm. Fixing Details: Sections for frame glazed shutter and mesh shutters should be cut to length and miter joined with polyprpylene corner brackets, mullion section should be joined with frame/mullion using mullion cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and fixed glass. Spoon Profile should be used around fly mesh to fix mesh in mesh shutter. Accessories: Each Glazed shutter and mesh shutter should be provided with SS Pivot Hinges-1set, seccolor handle & seccolor stay. Window frame should be fixed to brick/concrete masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screw into the caps through frame.
S&F glass shutter & fixed glass portions should be provided with a glass of 5mm plain float glass complete all as specified.
S&F Mesh shutter should be provided with a stainless steel 32 gauge fly mesh of 304 grades with 144 holes per square inch complete all as specified.
S&F window grill should be provided with Grill made of 10mm sq. MS Bars welded to at 150mm centre to centre, 6mmx12mm MS flat, Total Grill unit should be powder coated and fixed to window frame with screw complete all as specified.
S&F stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples or wooden beads supplied with shutters complete all as specified.
S&F rolled mild steel of grade Fe-290 (Grade E-165) in rolled section as in frames for doors/windows, framing for cladding, glazing and the like fixed with angle cleats and connecting plates, cooler stand etc complete all as specified.
M&L two coats of synthetic enamel paint over a red oxide primer including prepration of newly treated steel surfaces of girth exc 10cm complete all as specified.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification complete all as specified.
M&L Factory made solid panel of PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified.
M&L for 100mm long, medium weight, Mild Steel butt hinges fixed with doors complete all as specified.
S&F Aluminum tower bolts of extruded section of size 150mm complete all as specified.
S&F 150 mm size Extruded aluminium alloy handles, fabricated type, anodised handles complete all as specified.
M&L for pressed steel frames 165x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock, strike, plate etc complete all as specified.
M&L for pressed steel frames 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock, strike, plate etc complete all as specified.
M&L for PCC (1:2:4) type B-0, using 12.50mm aggregate in filling pressed steel frame, concrete shall be compressed complete all as specified.
S&F 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type both sides (ISI marked) all with 6mm thick teak wood edging all around complete all as specified.
S&F 35mm thick factory made second class hardwood glazed and skelton shutters, open rebated and prepared to receive glass, guaze, etc (without sash bars), edges of framing plain, chamferred or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified.
S&F 100mm long mild steel but hinges medium weight, cold rolled complete all as specified.
S&F 300mm long mild steel sliding door bolts, plate type, stove enamelled black with bright bolt not less than 16mm dia width including a minimum 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified.
S&F 150mm long Cast iron or malleable cast iron handles, cast type, stove enamelled black complete all as specified.
S&F 200mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified.
S&F 150mm size single action spring hinges, mild steel with steel wire spring, stove enamelled, black complete all as specified.
S&F Aluminium floor door stopper (overall length of cover plate 140mm) with suitable stops (double) fixed in wooden door to stop complete all as specified.
M&L two coats of synthetic enamel paint over a coat of pink primer including prepration of newly wooden surfaces of girth exc 10cm complete all as specified.
M &L for fabrication of pressed steel cupboard shutters using 1.00 mm thick MS plain sheet & with frame 1.25 MM thick bent to shape incl two coats of syn enamel paint on int surfaces & two coats of hammer tone finish on external surfaces alongwith locking arrangement mortice lock handle etc complete all as specified. Note :- Area of front face onle be measured for payment.
Taking up or down steel tubing and connection of bore 15mm complete all as specified.
Taking up or down steel tubing and connection of bore 20 mm complete all as specified.
Taking up or down steel tubing and connection of bore 40 mm complete all as specified.
Refixing old steel tubing and connections in new or old position as in walls, ceiling, floors etc bore of pipe 15mm complete all as specified.
Refixing old steel tubing and connections in new or old position as in walls ceiling floors etc bore of pipe 20 mm complete all as specified.
Refixing old steel tubing and connections in new or old position as in walls ceiling floors etc bore of pipe 40 mm complete all as specified.
S&F 15mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors complete all as specified.
S&F 20mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors complete all as specified.
S&F 40mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors complete all as specified.
S&F in replacement 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified.
S&F in replacement 40mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified.
S&F in replacement 15mm dia stop valves, screwed down high pressure, screwed both ends for iron pipe or for unions and fixed for 15mm bore but fancy type, chromium plated with long shank and cup (concealed type) complete all as specified.
S&F in replacement 15mm dia Stop valves, fancy type, chromium plated screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore complete all as specified.
S&F in replacement CP 15mm dia bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified.
S&F in replacement brass chromium plated shower rose complete all as specified.
S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified.
S&F in repair of toilet duct for soil water down take pipe fixing done with pipe supporting clamping system having profile bracket + slotted C channel + U bolt RM system from terrace to 1st floor running vertical fixed line with wall distance 3". Pipe support claming made of : 1. Profile bracket type A2 (wall distance 3") of low carbon hot rolled gauge corrected (HRG) Steel with ribs and notch are Hot Dip + Zn Al flake coated with flange bolt and flange nut are Zn AI flake coated. 2. Slotted 'C' channel B3 type to be used of size 10" of low carbon continuous slotted 'C' channel with ribs made of low carbon hot roll gauge corrected (HRGC) Steel are hot dip + Zn Al flake coated with material thickness of 3mm. 3. U bolt RM are made of low carbon mild steel with rod diameter 7mm approx; Zn Al flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with flange nut set having natural serration - Zn Al flake coated. Material Qty :- 1. Profile bracket of A2 type (wall distance 3") - 02 Nos. 2. Slotted 'C' Channel of B3 type size 10" - 01 Nos 3. U bolt R/M for 4" PVC pipe dia - 01 Nos (Pipe support clamping Unit fixing to be done at everty meter distance in the duct as specified in the Technical Drawing. Ref CE Jodhpur Zone Techincal Draing no. TD/102 sh 1/5).
S&F in repair of four kitchen duct for rain water pipe, domestic water supply pipes and tank supply riser pipe fixing done with pipe supporting clamping system having profile bracket + slotted C channel + U bolt RM system from terrace to 1st floor running vertical fixed line with wall distance 3". Pipe support claming made of : 1. Profile bracket type A2 (wall distance 3") of low carbon hot rolled gauge corrected (HRG) Steel with ribs and notch are Hot Dip + Zn Al flake coated with flange bolt and flange nut are Zn AI flake coated. 2. Slotted 'C' channel B3 type to be used of size 10" of low carbon continuous slotted 'C' channel with ribs made of low carbon hot roll gauge corrected (HRGC) Steel are hot dip + Zn Al flake coated with material thickness of 3mm. 3. U bolt RM are made of low carbon mild steel with rod diameter 7mm approx; Zn Al flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with flange nut set having natural serration - Zn Al flake coated. Material Qty :- 1. Profile bracket of A2 type (wall distance 3") - 02 Nos. 2. Slotted 'C' Channel of B3 type size 10" - 01 Nos 3. U bolt R/M for 4" PVC pipe dia - 01 Nos (Pipe support clamping Unit fixing to be done at everty meter distance in the duct as specified in the Technical Drawing. Ref CE Jodhpur Zone Techincal Draing no. TD/102 sh 1/5). Make : Shaivi or equivalent as approved by GE.
S&F in replacement 10 ltr PVC valve less, symphonic action type dual type flushing, low level, white, with inlet ball valve, float and handle including 600mm long PVC connection and brackets complete all as specified and directed by Engineer-in-Charge
S&F in replacement vitreous china squatting pan, Órrisa Patern' size 580mmx440mm white with integral foot rests, embedded and set in PCC 1:5:10 type E2 (using 40mm stone aggregate) and making good to dismantled floor including removing rubbish complete all as specified and directed by Engineer-in-Charge
S&F in replacement Vitreous china wash hand basin (Corner Type) white, flat back including fixing brackets, 32mm waste pipe, 15mm CP pillar taps and waste cuppling chromium plated complete all as specified.
S&F in replacement Stainless steel kitchen plate rack 1.0mm thick of size 750 x 600 x 250mm complete all as specified.
S&F in replacement sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified.
S&F in replacement grating doom 100mm dia of PTMT (min weight 25 gms) complete all as specified.
S&F in replacement brass chroumium plated Tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified.
S&F in replacement bath cabinet of PTMT fixed with and including chromium plated brass screws and wooden cleats size 355mmx455mm complete all as specified.
S&F in replacement Stainless steel peg set of 5 size 300x25 & 2mm thick complete all as specified and directed
S&F in replacement 20mm dia Harrison rails, chromium plated with fixing brackets, stops, rollers (two nos of brackets/knobs/corners for one length/each opening) etc complete all as specified.
Dismantling of existing water tanks (PVC/RCC/AC) exc 250 ltr but n.exc 500 ltr capacity and removing from site complete all as specified.
Supply and fixing ISI marked 500 Litre capacity rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm brass ball valve high pressure complete all as specified.
M&L for PCC 1:3:6 type C2, using 40mm graded stone aggrgates as in platform to PVC water tanks complete all as specified.
Dismantling of 100mm dia cast iron pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified.
Dismantling of 75 mm dia cast iron pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified.
S&F 75mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified.
S&F 75mm dia Cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified.
S&F 75mm bore dia cast iron soil, waste and vent pipes, sand cast, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified.
S&F 75mm bore dia cast iron soil, waste and vent pipes, sand cast, in any length with or without ears, with cement joints, fixed in wall complete all as specified.
S&F100mm dia cast iron soil waste and vent pipes ISI marked in any length with or without ears using cement joints fixed inwith cement joints, laid in trenches or in floors complete all as specified.
S&F100mm dia cast iron soil waste and vent pipes ISI marked in any length with or without ears using cement joints fixed in walls complete all as specified.
S&F 100mm dia CI Tee branch single (equal or unequal) ordinary or inverted (spigot or socket type of or with paralled branches with oval access door complete all as specified.
S&F 100mm dia CI Tee branch single (equal or unequal) ordinary or inverted (spigot or socket type of or with paralled branches without oval access door complete all as specified.
S&F in repairs 100mm dia CI bends (any radious) diminishing pieces or tapers (larger bore shall be measured) with oval access door complete all as specified.
S&F 100mm cast iron 'P' or 'S' trap complete all as specified.
S&F 100mm cast iron cowl complete all as specified.
S&F 100mm cast iron sanitary connection socket to fit in WC out-let complete all as specified.
Demolition of reinforced cement Concrete in Roofs, floors (other than ground floors), beams staircases, landing, chajjas, roof projection in D/S bldgs and similar suspended work complete all as specified and directed
M&L RCC 1:2:3 (20mm graded aggregate) for chajja, roof projection in D/S bldgs, fins facia, stair case, landing, balcony & the like etc complete all as specified.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent shape required, including welding to existing reinforcement cranking bending, hooking etc and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified.
Formwork to fins, louvers, fascia, chejjas, roof projection in D/S bldgs, stair case etc complete all as specified.
Removing of existing filling in sunken floor of WC and repair to sunken floor with 15mm thick plastering in CM 1:3 of internal surface mixed with WPC, than painting with bitumen 30/40 over a coat of bitumen primer, putting 50 micron polythene than filling with PCC 1:5:10 type E-2 using 40mm graded stone aggregate and inserting 50mm bore 1.00M long GI water tubing to the wall complete all as specified. Note : WC and tiles shall be measured and paid separately complete all as specified.
Demoliton of cement concrete of any description & in any position not otherwise specifically provided for and removing debries out of MD land complete all as specified.
M&L cement concrete 1:2:4 mix type B-0 (12.5 mm graded stone aggregate) in padding finishing surface of concrete topping even and fair (without using extra cement) all as specified of average thickness 40mm in slope 1:40 over roof complete all as specified.
M&L for 10mm thick plastering in CM(1:3) on concrete roof surfaces with water proofing compound @ 3% by weight of cement and finishing the surface even and fair without using extra cement including taking down existing plaster and APP membrane complete all as specified. Note :- WPC shall be measured and paid separately.
Supply only integral water proofing compound complete all as specified.
M & L painting roof surfaces with one coat of bitumen primer T-10/ polymerised grade conforming to IS-3384 @ 0.30kg /Sqm and one coat of bonding material using blown type bitumen confirming to IS-702 grade 85/25 @ 1.20 Kg/Sqm laying of 3mm thick and weight not less than 3.50 Kg/Sqm with 10cm side overlap having centre core of 100 micron HMHDPE, outer film is 20 micron each and applying one coat of bonding material using blown type bitumen confirming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm over APP membrane complete all as specified.
M&L for Endura cool roof SRI tiles of size 300x300mm, 10mm thick of, laid over and including 15mm thick bedding in cement mortar (1:4), joints grouted and flush pointed in cement mortar (1:3) mixed with 5% crude oil by weight of cement. The tiles shall be laid either through authorized applicator who has laid the APP membrane or by the contractor under the supervision of the authorized applicator of APP membrane complete all as specified.
M&L 50 mm thick PCC (1:3:6) type C1 (by using 20mm aggregate) in plinth protection complete all as specified.
M & L Stone Slab 25 mm to 35 mm thick dressed true and square in one length not less than 60 cm and n exc 120 cm in copings, window cills, chajjas, sunshades, plinth protections etc, punched dressed on exposed faces and self faced on the embedded unexposed beds and joints; exposed edges rounded or chamfered as directd, set, jointed and pointed in cement mortar complete all as specified
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out hard/dense soil complete all as specified.
Removing excavated material (Soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
Returning , filling in including in spreading , leveling, watering and well raamming in layers.n exc 25 cm complete all as specified.
Demolition and breaking up drain pipes ( AC or reinforced concrete) of internal dia 150mm set in cement mortar of any description including the Demolition of PCC under and haunching etc complete all as specified.
M&L Cement concrete 1:4:8 type D-2 Concrete bed to drain pipes (150mm) including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified.
M&L 150mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars including connecting to existing main holes complete all as specified.
M&L for 75mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified.
Material and labour for 25mm thick PCC (1:2:4) type B-0, using 12.50mm graded stone aggregate as in base concrete to floor finish complete all as specified.
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified.
M&L for pre-cast concrete block as in Kerb Stone (Machine made) with solid blocks Type B1, 1:2:4 (20mm graded stone aggregate) exc 10 cm in width and setting in cement mortar 1:4 complete all as specified.
S&F in replacement 32mm PVC waste pipe for sink/WHB complete all as specified.
Taking down old unserviceable point wiring ( light/fan/socket/power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, pendants,regulators, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls, floors, ceiling etc complete all as specified.
Taking down old unserviceable/worn out sub main wiring of any type and size complete all as specified.
Taking down hot water heater(Geyser) any capacity keeping with safe custody and refixing the same with the help of fasterners/nut bolts complete all as specified.
Taking down Main switches/DBs of any make and type including teakwood board, MCBs/MCCBs etc. complete and making good the disturbed surfaces including colour wash complete all as specified.
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in PVC rigid conduits heavy duty ISI marked totally concealed in wall/floor/roof including all accessories etc. with sunken boxes suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly, suitable for One light/fan/bell point controlled by one, One-way switch complete all as specified. Note- (i) Cutting in chases and pointing in will be done by contractor without any cost. (ii) Making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost. (iii) 3 Run of 1.5 Sqmm conductor and 1 run of PVC conduit shall be measured as one RM.
All as per item No. 135.00 above but One 5 pin 5Amp Socket outlet point on same board with other switches including earth wire complete all as specified.
All as per item No. 135.00 above but One 5 pin 5Amp Socket outlet point on independent board complete all as specified.
All as per item No. 135.00 above but One 5 pin 5Amp Socket outlet point on independent board complete all as specified.
All as per item No. 135.00 above but One bell/buzer point controlled by one bell push complete all as specified.
All as per item No. 135.00 above but One light point controlled by two 2-way switches complete all as specified.
All as per item No. 135.00 above but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board complete all as specified. (ii) 3 Run of 2.5 Sqmm conductor and 1 Run of PVC conduit shall be measured as one RM. Note:- Making good of disturbed surfaces will be done by contractor without any claims.
S&F sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) surface mounted / concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc complete all as specified. Note :- Two runs of 4.00 Sqmm cable with one run of 4.00 Sqmm earth wire and PVC conduit shall be measured & paid for as one length.
S&F sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) surface mounted / concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc complete all as specified. NOTE: Two runs of 6.00 Sqmm cable with one run of 6.00 Sqmm earth wire and PVC conduit shall be measured & paid for as one length.
S & F piano flush type switch 5 Amps single pole one way all as specified.
S & F multipurpose socket outlet with piano flush type 3 pin 5 Amps all as specified.
S & F piano flush type switch 15 Amps single pole all as specified.
Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type all as specified.
S&F ceiling rose surface type three terminals complete all as specified and directed.
S&F bell electrical ding dong including hard PVC board ISI marked complete all as specified.
Supply and fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
S & F for Bell push, flush type, 5 amp complete all as specified.
S & F piano flush type two way switch 5 Amps single pole.
S & F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
S & F LED lamp (Inverter type) 12 Watt, 240 Volt complete all as specified.
Taking down old unsv ceiling fan & Supply and fixing new ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). Note- Old unsv ceiling fan deposite in E&M yard.
S & F LED based security light 35 W in aluminium pressure die cast housing with touched glass cover having IP 66 Protection and with aluminium bracket including taking down of old unservicable security light complete all as specified.
S & F 240 V, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 amp single pole MCB complete all as specified.
S&F MCB TPN DB 4 way double door with 200 amps rated busbar 415 V complete all as specified.
S&F MCB SPN DB 8 way, double door, with 200 amp rated busbar 240 V complete all as specified.
S & F for MCB SP rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified.
S & F for MCB SPN of rated capacity 32 amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified.
S & F for MCB SPN of rated capacity 40/63 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified.
S & F for MCB TPN of rated capacity 40/63 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250/300mm complete all as specified.
Supply and fix Turbo heavy duty Metal body exhaust fan 300 mm sweep (1400RPM), 4 blade including louvers grounting with nut bolts complete all as speicified.
M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work of soft/loose soil and testing on completion etc complete all as specified.
M & L for cutting/making of hole suitable size for 300mm exhaust fan in the stone masonary/brick wall and making good the surfaces by plastring of cement mortar and finish surface with existing wall complete all as specified.
D.K.CONSTRUCTION CO (BID ID -3284879)
Mahadev construction (BID ID -3286550)
Bhawani Enterprises (BID ID -3283997)
BHAKAR RAM AND SONS (BID ID -3287886)
POOJA CONSTRUCTION (BID ID -3284597)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .