Loading…
Loading…
Tender Value
₹47.6 L
EMD Value
₹40,000
Closing Date
2 Sept 2026, 6:00 pm
Executive Engineer - UGVCL KALOL DO
Annual Rate Contract for Shifting of RMU and UG Infrastructure at various area of KALOL-2 Sub Division
336773
KLL-DO-14-2026-27/SR NO-5
Open
Power/Energy Projects/Products/Services
Works
Gandhinagar
17 documents required · 17 mandatory
₹1,180
UGVCL- KALOL
₹40,000
19 Aug 2026
19 Aug 2026
19 Aug 2026
2 Sept 2026
19 Aug 2026
Sub Division SCHEDULE-B
Description Qty Unit Rate Amount
Erection of 3-way RMU with PLINTH including material
without RMU as per specification
Erection of 4-way / 5-Way RMU with PLINTH including
material without RMU as per specification
Extension of existing plinth : Construction of RMU Plinth
(Extension of One way)
Erection of Double pole structure of 10 meters X 270 kg
PSC poles including excavation of pits & refilling of
earthing, fixing of channels, supporting angles ,clamps,
anti-climbing devices danger boards, insulators etc.
complete and painting of fabricated materials used on the
poles and numbering without cost of nuts & bolts with
cost of paint as per standard specification but excluding
erection of guy sets and earthing.(Without AB Switch)
Construction of Plinth for installation of Transformer (up
Construction of Plinth for installation of Transformer (630
& 800 KVA) 3.15 x 2.90 x 0.75 Meter above ground
Construction of Plinth for installation of Transformer (1000
KVA) 3.15 x 3.40 x 0.75 Meter above ground
Construction of Plinth for installation of Transformer (1250
KVA) 3.15 x 3.65 x 0.75 Meter above ground
Normal Laying: Laying of various size Single Circuit of 11kV
XLPE insulated Aluminum armoured cable in Cable trench
up to the minimum depth of 1200 mm is to be dug with
width of 300 mm in any type of soil. Spreading of sand at
the bottom of the trench up to 100mm before lying of
power cable in the centre of the trench. Spreading of
another layer of 100mm sand above laid cable. Utmost
care should be taken while loading / unloading and
unwinding the cable drums. Covering the cable with RCC
half round hume pipe 30mm thick, 150mm inner
dia.before refilling pre-bonding tap/warning tap should
provide below 700 mm from the ground level and back
filling the same to make ground level as per original., Back
feeling the trench so as to make ground level as per
original. Laid cable up to cable box of Plinth Mounted RMU
/ Transformer shall be part of Normal Laying. [The rates
are exluding supply of cable]. (185/240/300 SQMM Cable
Signature of Contractor & seal
Division Office: Kalol, Mahendra Mill Road, Kalol (N.G)-382721, Telephone : (02764)223773
E-Mail:- [email protected] Website: www.ugvcl.com
Save Energy for Benefit of Self and Nation
SINGLE LOGO LETTERHEAD
Normal Laying: Laying of various size Double Circuit of
11kV XLPE insulated Aluminum armoured cable in Cable
trench up to the minimum depth of 1200 mm is to be dug
with width of 500 mm in any type of soil. Spreading of
sand at the bottom of the trench up to 100mm before lying
of power cable in the centre of the trench. Spreading of
another layer of 100mm sand above laid cable. Utmost
care should be taken while loading / unloading and
10 unwinding the cable drums. Covering the cable with RCC 50 MTR 468
half round hume pipe 30mm thick, 150mm inner dia before
refilling pre-bonding tap/warning tap should provide below
700 mm from the ground level and back filling the same to
make ground level as per original., Back feeling the trench
so as to make ground level as per original. Laid cable up to
cable box of Plinth Mounted RMU / Transformer shall be
part of Normal Laying.[The rates are excluding supply of
Laying of various sizes of 1.1 KV XLPE insulated Aluminum
armoured cable in cable tray/ trench over/below the
ground level [The rates are excluding cable tray, only
labour charges].
Laying of various size of 1.1 KV XLPE insulated Aluminum
armoured cable above ground in air for termination of
12 cable on Pole as per site condition and instruction of 50 MTR 38
engineer in charge [The rates are excluding cost of clamp
Providing of OD 160 mm HDPE Pipe, minimum thickness as
per IS 4982 and amendment thereof, confirming to IS
4984:1955 (Amendment no. 2) for HT UG Cable [Rates are
excluding laying of cable]
Laying by Push Through of OD 160 mm HDPE Pipe,
minimum thickness as per IS 4982 and amendment thereof,
confirming to IS 4984:1955 (Amendment no. 2) for HT UG
Cable [Rates are excluding laying of cable]
Providing of OD 110 mm HDPE Pipe, minimum thickness as
per IS 4982 and amendment thereof, confirming to IS
4984:1955 (Amendment no. 2) for HT UG Cable [Rates are
excluding laying of cable]
Laying by Push Through of OD 110 mm HDPE Pipe,
minimum thickness as per IS 4982 and amendment thereof,
confirming to IS 4984:1955 (Amendment no. 2) for HT UG
Cable [Rates are excluding laying of cable]
Supply installation & commissioning of earthing conductor
40 x 3 G.I. strip for all electrical equipments as well as
connection to be made. Rates inclusive of hot dipped
Signature of Contractor & seal
Division Office: Kalol, Mahendra Mill Road, Kalol (N.G)-382721, Telephone : (02764)223773
E-Mail:- [email protected] Website: www.ugvcl.com
Save Energy for Benefit of Self and Nation
SINGLE LOGO LETTERHEAD
Supply installation & commissioning of earthing conductor
38 x 3 G.I. strip for pole mounted transformer and up to
FSP,RMU as well as connection to be made to the earth
pit. Rates inclusive of hot dipped hardwares.
Supply installation & commissioning of earthing conductor
25 x 3 G.I. strip for pole mounted transformer and up to
FSP,RMU as well as connection to be made to the earth
pit. Rates inclusive of hot dipped hardwares.
Carbon Earthing for UG Equipment: Supplying & erecting of
maintenance free earthing system comprising of 17.2 mm
dia 3 mtr Long Earthing Electrode of low carbon steel
electrode with 250 micrns copper coating + carbon based
conductive concrete back fill safe compound(resistivity of
less than 0.10 ohm mtr) & copper clamp.Making 100 mm
Dia Bore, 3 Mtr Long, Making of Earth pit chamber in
providing & fixing HT push on/heat shrink type end indoor
21 termination kit (Any make approved by GUVNL & Its 10 Nos. 4927
Subsidiaries Company)(70 mm2 HT XLPE cable )
providing & fixing HT push on/heat shrink type end indoor
22 termination kit (Any make approved by GUVNL & Its 10 Nos. 5162
Subsidiaries Company)(120/150/185 mm2 HT XLPE cable )
providing & fixing HT push on/heat shrink type end indoor
23 termination kit (Any make approved by GUVNL & Its 10 Nos. 5461
Subsidiaries Company)(240 mm2 HT XLPE cable )
providing & fixing HT push on/heat shrink type end indoor
24 termination kit (Any make approved by GUVNL & Its 10 Nos. 5758
Subsidiaries Company)(300/400 mm2 HT XLPE cable
providing & fixing HT push on/heat shrink type end
25 Outdoor termination kit (Any make approved by GUVNL & 10 Nos. 5873
Its Subsidiaries Company)(70 mm2 HT XLPE cable )
providing & fixing HT push on/heat shrink type end
Outdoor termination kit (Any make approved by GUVNL &
Its Subsidiaries Company)(120/150/185 mm2 HT XLPE
providing & fixing HT push on/heat shrink type end
27 Outdoor termination kit (Any make approved by GUVNL & 10 Nos. 6587
Its Subsidiaries Company)(240 mm2 HT XLPE cable
providing & fixing HT push on/heat shrink type end
28 Outdoor termination kit (Any make approved by GUVNL & 10 Nos. 6885
Its Subsidiaries Company)(300/400 mm2 HT XLPE cable )
providing & fixing HT push on/heat shrink type end
29 Straight Joint (Any make approved by GUVNL & Its 10 Nos. 7408
Subsidiaries Company)(70 mm2 HT XLPE cable )
Signature of Contractor & seal
Division Office: Kalol, Mahendra Mill Road, Kalol (N.G)-382721, Telephone : (02764)223773
E-Mail:- [email protected] Website: www.ugvcl.com
Save Energy for Benefit of Self and Nation
SINGLE LOGO LETTERHEAD
providing & fixing HT push on/heat shrink type end
30 Straight Joint (Any make approved by GUVNL & Its 10 Nos. 7864
Subsidiaries Company)(120/150/185 mm2 HT XLPE cable )
providing & fixing HT push on/heat shrink type end
31 Straight Joint (Any make approved by GUVNL & Its 10 Nos. 8089
Subsidiaries Company)(240 mm2 HT XLPE cable
providing & fixing HT push on/heat shrink type end
32 Straight Joint (Any make approved by GUVNL & Its 10 Nos. 8249
Subsidiaries Company)(300/400 mm2 HT XLPE cable )
33 Erection of FSP/MSP 1250 / 800 / 650 / 400 AMP 15 Nos. 2811
Erection of Plinth and foundation for FSP/MSP 1250 /
LT CABLE TERMINATION OF ANY SIZE OF LT CABLE : Cable
termination (Indoor / Outdoor / Straight Joints) on LT
Pole, FSP, LT Distribution Transformer Box of pole
35 mounted transformer of LT cable grade as specified below 10 Nos. 125
including cutting, stripping of cable, insulations, providing
compression type terminals including supply of suitable
cable glands, crimping lugs with necessary connections.
Replacement of Transformer (irrespective of kVA Rating):
Existing Transformer with Cable Box shall be dismantled
and New Transformer with Cable Box shall be installed.
Existing Transformer with Cable Box shall be submitted to
UGVCL Store as per instruction of Engineer - in - Charge.
Termination, earthing etc. shall be billed separately.
Replacement of RMU (irrespective of configuration):
Existing RMU shall be dismantled and New RMU shall be
37 installed. Existing RMU shall be submitted to UGVCL Store 5 Nos. 8850
as per instruction of Engineer - in - Charge. Termination,
earthing etc. shall be billed separately.
37 Installation Testing and commi. Of RMU on new plinth 10 Nos. 4425
38 Dismantling Of RMU from Old plinth 10 Nos. 2250
39 Dismantling/Demolition of Old unused plinth 20 Nos. 2000
40 Welfare Cess @ 1% 1 Each 39933
TOTAL WITH WELFARE CESS
NET TOTAL WITH 18% GST &1% WELFARE CESS
Executive Engineer
Signature of Contractor & seal
Division Office: Kalol, Mahendra Mill Road, Kalol (N.G)-382721, Telephone : (02764)223773
E-Mail:- [email protected] Website: www.ugvcl.com
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SR NO-5 SCHEDULE B UG RMU AT KALOL-2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].