| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.5 L+₹85,294.50 (3.77%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹28.6 L+₹6.0 L (26.5%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹30.2 L+₹7.6 L (33.4%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹34.3 L+₹11.7 L (51.8%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Dec 2019, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPECIAL REPAIRS TO CONVENTIONAL LIGHTS TO LED LIGHTS AT TECHNICAL BUILDINGS AND SPECIAL REPAIRS ON PACKAGE AC AT 5N DET BARRACKPORE INCLUDING CERTAIN REVENUE, MINOR, SPECIAL REPAIRS AND LBW WORKS AT BARRACKPORE UNDER GE BARRACKPORE
2019_MES_295856_1
8360/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Barrackpore
Refer to tender documents
2 documents required · 2 mandatory
₹500
GE Barrackpore
₹80,000
Yes
16 Jan 2020
7 Nov 2019
20 Dec 2019
8 Nov 2019
18 Dec 2019
30 Nov 2019
Amount
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty at necessary holes for smooth finishing complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note: All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)
One light point controlled by one switch .
One light point controlled by two Nos two way switches .
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One bell/buzzer point controlled by one bell push.
All as per Item No.2.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FRLSH and earth conductor of size 2.5 sqmm PVC insulated multistranded flexible copper conductor FRLSH complete all as specified and directed for the following:-
One 6 pin, 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
One 6 pin, 16/6 amps socket outlet point controlled by one 16 amps switch on same board.
All as per Item No.2.00 here-in-before but point wiring with 4.0sqmm PVC insulated multistranded flexible unsheathed copper conductor FRLSH and earth conductor of size 4.0 sqmm PVC insulated multistranded flexible copper conductor FRLSH of 3 pin, 16 Amps socket outlet complete all as specified and directed .
S&F for modular type switch 6 Amps, single pole, 1 way, 1/2 module, 240V, AC, with lable for marking of light/fan, ISI Marked complete all as specified and directed.
S&F for modular type switch 10 Amps, single pole, 1 way, 1/2 module, 240V, AC, with lable for marking of light/fan, ISI Marked complete all as specified and directed.
S&F for modular type switch 10 Amps , 2way, single pole,1/2 module, 240V, AC and including with indication mark label, ISI Marked complete all as specified and directed.
S&F for modular type bell push 6 Amps,1/2 module, single pole, 240 volts, AC with indicator and lable for bell ISI Marked Complete all as specified and directed.
S&F for ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body, complete all as specified and directed.
S&F for modular type switch, 6 amps, single pole, 1 way, 1/2 module, 240V, ISI marked complete as in repair all as specified and directed.
S&F for modular type switch, 16 amps, single pole, 1 way, 1/2 module, 240V, ISI marked complete as in repair all as specified and directed.
S&F for modular type switch, 10 amps, single pole, 1way, 1/2 module, 240V, ISI marked complete as in repair all as specified and directed.
S&F for modular type socket shutter type, 6 Amps, 2/3 Pin combined 2 module, 240V, AC, ISI marked as in repair complete all as specified and directed.
S&F for modular type socket 16 Amps, 6 Pin combined shuttered socket, 2/3 module with light indication, 240Volts, AC, ISI marked complete as in repair all as specified and directed.
S&F for modular type switch, 10 amps, 2 way, single pole, single module, 240V, AC and including with indication ISI marked complete as in repair all as specified and directed.
S&F for fan regulator electronic, modular type, stepped type (01 to 4/5), 100 to 120 watts, 240 volts, AC, ISI Marked complete in repairs all as specified and directed.
S&F for modular type bell push, 10Amps, 1/2module, single pole, 1 way, 240V, ISI Marked complete in repairs all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete as in repair all as specified and directed.
S&F for red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1/2 module ISI marked complete as in repair all as specified and directed.
S&F for modular type socket shutter type, 6 Amps, 2/3 Pin combined 2 module, 240V, AC, ISI marked complete all as specified and directed.
S&F for LED 18 Watt batten light fittings in and including LED lamp, with inbuilt driver, pre wired including necessary electric connection with required size copper cable complete all as specified and directed . (Make : CG cat No : DMLN1LT8-16/ Havells cat No : REGALBATTENT8UPTO1X18WDSBSWH as approved)
S&F for 20 watt LED fittings in and including LED tube light of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible conductor cable of required size complete all as specified and directed. (Make : Havells Cat No LUMILINEPLUSBS20WLED865SPCSS/ Crompton Greaves cat No : LTT8-20 as approved)
S&F for recess mounting 2'X2' LED 36 watt/34 watt LED light fittings in and including LED tube light with white powder coated frame blended seamlessly with ceiling layout suitable for 600mmX600mm modular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fittings with and including three core sheathed flexible conductor cable of required size complete all as specified and directed. (Make: Crompton Greaves Cat No.LCTLRN-36-FO-CDL / Havells Cat No- PLUTONEO2X2PLR34WLED857S as approved )
S&F for batten type 9 watt LED fitting in and including LED tube light of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible conductor cable of 0.50 Sqmm size and including mounted on PVC/Wooden round/square blocks-02 Nos including removing old unserviceable light fittings complete all as specified and directed. (Make: Havells Cat No REGALBATTENT8UPTO1 x 09WDSBSWH/Crompton Greaves cat No : DMLN1LT8-8 for fittings and Havells Cat No TL10WLED 865SPC/Crompton Greaves cat No LT8-8-865-2 for LED lamp as approved)
S&F for batten type 9 watt LED fitting in and including LED tube light of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible conductor cable of 0.50 Sqmm size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make : Havells Cat No. LUMILINEBS9WLED65SPCWH/ Crompton Greaves cat No. LCTL-9-CDL as approved)
S&F for batten type 20/22 watt LED fitting in and including LED tube light of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible conductor cable of 0.50 Sqmm size and including mounted on PVC/Wooden round/square blocks-02 Nos including removing old unserviceable light fittings complete all as specified and directed. (Make: Havells Cat No REGALBATTENT8UPTO1 x 22WSSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and Havells Cat No TL20WLED 865SPC or PHOTONULTRA1213T8SSTL20WLED/Crompton Greaves cat No LT8-20-865-2 for LED lamp as approved)
S&F for decorative type surface mounted 1X6 watts LED light fitting with LED lamps including fixing arrangements at any hight with nuts ,screws and washers and connected to ceiling rose and including removing old unserviceable fittings complete all as specified and directed. (Make: Crompton Greaves cat No.LCSR-06-CDL / Havells cat No EDGEPRORDDLR6WLED857S as approved)
S&F for recess mounting 2'x2' LED 36 Watt light fitting slimmest 9 mm thin in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm modular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting and including removing old unserviceable item complete all as specified and directed complete as in repair all as specified and directed, (Make: Crompton Cat No.LCPL-36-CD(2x2) / Havells Cat No. ENDURASLIMPROPLUS2X2PLR36WLED857MOD as approved )
S&F for recess mounting 1'x4' LED 40 Watt/36 Watt light fitting in and including LED tube light with powder coated CRCA housing with LED glare free front frame with flat white high transmission acrylic cover and also can be suspended with provided kit and including connecting up with ceiling rose to fitting with flexible copper conductor cable of required size complete all as specified and directed. (Make: Crompton Cat No. LCTLRN-40-CDL(1x4) / Havells Cat No. VENUSNEOHE4XIPLR28-36WLED857MOD as approved )
Supply and installing hi-wall split air condition units indoor and outdoor complete with 2 Nos bracket (powder coated) cordless remote control indoor and outdoor units with inbuilt air ioniser, plasma filter for better indoor air quality with inverter technology (Five Star rating), EER 3.2 and R-32 of capacity 1.5 TR with all accessories complete all as specified and directed. (Make: Voltas/Daikin/Hitachi as approved)
Supply and installation, commissioning voltage stabilizer of digital type for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 100 v to 300 volts with output voltage stabilized at 230 volts with accuracy of +/- 2.5 % and of capacity 5.0 KVA (16 Amp rated) complete all as specified and directed. (Make : V-Guard Model No VGB-500 digital/Microtek Model No : EML5090 as approved)
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in patches not exceeding 3 sqm each patch in cement mortar (1:6) on brick work or concrete surfaces, finished even and smooth without using extra cement on plastered surface complete all as specified and directed.
S&F for 25 mm dia (heavy) chromium plated curtain rod (as approved by GE) complete all as specified and as directed.
S&F for MS brackets (as approved by GE) powder coated for 25mm dia curtain rod complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion over a coat of alkaline resistant primer over and including applying 3mm thick wall care putty after preparation of newly plastered surfaces of walls complete all as specified and directed.
S&F for UPS for 30 minute back up single phase AC input 160 to 260 volt and output 230 volts ±1% of capacity 5 KVA complete all as specified and directed. (Make: APC/Microtek/Hitachi/Emerson as approved)
M&L for sub main wiring (concealed) complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing complete all as specified and directed . (Note : Two run of 6 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit)
M&L for sub main wiring (concealed) complete with 2 run of 2.5 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 20 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 1.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing complete all as specified and directed. (Note : Two run of 2.5 sqmm single core copper conductor cable and one run of 1.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 2 way for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand / Hager / L&T as approved)
S&F for powder coated sheet metal enclosure with metal type acrylic door, 415 volts, AC, VTPN DB (V-vertical type distribution board) 8 way plus 24 modules, for flush mounting with 200amps copper busbar, 2 neutral/earth bar for ease of installation and MCCB incomer of rating upto 200Amps, FP and MCB SP /TP MCB's as outgoing and complete connecting cable links with top and bottom with IP54 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete as in repair all as specified and as directed. (Make: Legrand cat No.5077 32, 8 way / Hager Cat No.VYVO8DM-P / L&T Cat No.DBVTH008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps , MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand cat No.5076 21 8 way / Hager Cat No.VYS08G / L&T Cat No.DBSPN008GD as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 8 way for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete as in repair and all as specified and as directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08G / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 4 way suitable for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete as in repair and all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way / Hager Cat No.VYS04G / L&T Cat No. DBSPN004GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100 amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB TPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way / Hager Cat No.VYT04GH/ L&T Cat No. DBTPE004GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 4 way suitable for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete as in repair and all as specified and directed. (Make:- Legrand cat No. 5076 20 4 way / Hager Cat No.VYS04G / L&T Cat No. DBSPN004GD as approved)
S&F for suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts suitable for AC's complete all as specified and directed. (Make : Legrand /Havells/L&T as approved)
S&F for MCB, SPN, 240 Volts, 32 Amps, 10 KA, 'C' series, AC, ISI Marked, 50 Hz complete all as specified and directed. (Make: Legrand / Hager / L&T as approved)
S&F MCB, SPN, 40 Amps to 63 Amps 'C' series 240 volts, ISI marked complete all as specified and as directed. (Make: Legrand / Hager / L&T as approved)
S&F for MCB, SP 6 Amps to 32 Amps, 'C' series, 240 Volt, 10KA, 50Hz, ISI marked complete all as specified and directed. (Make: Legrand / Hager / L&T as approved)
S&F for MCB, TPN, 63 Amps, 10 KA, "C" series, AC, 415 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: Legrand cat No.4086 83/ Hager cat No. NCN463N / L&T Cat No. BB40630C as approved)
S&F for MCCB, four Pole, 100 Amps, breaking capacity Icu at 415 AC, 50 HZ, 25 KA all as specified and as directed. (Make : L&T Cat CM91712OOK1O0G/Havells Cat No. IHLGHF0100/Legrand Cat No. 4200 55 as approved)
M&L for earthing complete with copper earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper earth strip of size 20 x 3.15mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing. (Copper strip upto 7.5m including testing consider in this item).
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised steel earth strip of size 25 x 4mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part I including testing on completion all complete as specified and directed . (Galvanised strip upto 7.5m including testing consider in this item).
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete after taking down old earthing all as specified and directed. (Galvanised iron wire upto 7.5m including testing consider in this item).
M&L for test point terminal box made of gunmetal or phosphorus bronze size 75 x 75x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal heads screw complete all as specified and directed.
S&F for modular metal flush box 1 module, 1.63mm thickness, ISI marked complete as in repairs all as specified and directed.
S&F for metal flush box 2 module, 1.60mm thickness, ISI marked complete as in repairs all as specified and directed.
S&F for modular metal flush box 3 module, 1.60mm thickness, ISI marked complete all as specified and directed.
S&F for metal flush box 3 module, 1.60mm thickness, ISI marked complete as in repairs all as specified and directed.
S&F for metal flush box 4 module, 1.60mm thickness , ISI marked complete as in repairs all as specified and directed.
S&F for metal flush box 5 module, 1.60mm thickness , ISI marked complete as in repairs all as specified and directed.
S&F for metal flush box 6 module, 1.60mm thickness, ISI marked complete as in repairs all as specified and directed.
S&F for metal flush box 8 module, 1.60mm thickness , ISI marked complete as in repairs all as specified and directed.
S&F for metal flush box 12 module, 1.60mm thickness , ISI marked complete as in repairs all as specified and directed.
S&F for metal flush box 16 module, 1.60mm thickness , ISI marked complete as in repairs all as specified and directed.
S&F for modular white cover plate with frame, 3 module, ISI marked including screws, washers etc complete all as specified and directed.
S&F for modular white cover plate with frame, 1 module, ISI marked including screws, washers etc complete as in repairs all as specified and directed.
S&F for modular white cover plate with frame, 2 module, ISI marked including screws, washers etc complete as in repairs all as specified and directed.
S&F for modular white cover plate with frame, 3 module, ISI marked including screws, washers etc complete as in repairs all as specified and directed.
S&F for modular white cover plate with frame, 4 module, ISI marked including screws, washers etc complete as in repairs all as specified and directed.
S&F for modular white cover plate with frame, 5 module, ISI marked including screws, washers etc complete as in repairs all as specified and directed.
S&F for modular white cover plate with frame, 6 module including, ISI marked screws, washers etc complete as in repairs all as specified and directed .
S&F for modular white cover plate with frame, 8 module, ISI marked including screws, washers etc complete as in repairs all as specified and directed .
S&F for modular white cover plate with frame, 12 module, ISI marked including screws, washers etc complete as in repairs all as specified and directed
S&F for modular white cover plate with frame, 16 module, ISI marked including screws, washers etc complete as in repairs all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed . (NOTE: Excavation/earth wall, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed
M&L for brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil complete all as specified and directed.
Removing excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Servicing & repairs to package type air conditioner of capacity 11.0 TR of make BLUE STAR by relplacing all unserviceable/ worn out parts of the machine including charging of Refrigerant gas, making system leak proof, Brazing the suction / discharge tubes where required and cleaning of Condensing unit, cleaning of all filters Checking/repairs to Electrical panels ,sensor unit for proper functioning and replace where required/ ordered all as directed and testing on completion complete all as specified and directed. NOTE: (i) Spares will be measured and paid separately as supply only. (ii) Refrigerant gas will be measured and paid separately as supply only if required. (iii) Old unserviceable spares shall be removed from site without extra cost to the department.
Supply only following items to be incorporate as required against Item No.84.00 here-in-before:-
Three pole AC power contactor, 32 Amps, 415 Volt with auxilary contact 2NO + 2NC, having coil voltage 380 to 400 (As per sample)
Intigrated circuit board with all electronic components suitable for 11.0 TR capacity Bluestar Package type Air conditioner.
High pressure cut off valve 275 lbs suitable for 11.0 TR capacity package AC of make Bluestar. (Make:Indofoss/Danfoss/Ranco as approved)
Low pressure cut off valve 25 lbs suitable for 11.0 TR cap package AC . (Make:Indofoss/Danfoss/Ranco as approved)
V-Belt suitable to fit blower motor unit. (Make: Fenner/Dunlop/Danfoss/Indofoss as approved)
Hermetically sealed compressor unit of capacity 5.5 TR suitable to fit with Blue star package air conditioner including initial filling of refrigerant gas to the required pressure. (Make Voltas/Kirloskar/Blue Star/Carrier/Hitachi as approved)
Blower fan motor with blade suitable for outdoor unit of package type AC plant of 11.0 TR capacity (as per sample)
S&F of micro-filter after dismantling of old filter from filter chamber inside air duct for dust free and bacteria free fresh air to the conditioned area complete all as specified and directed (as per sample).
Supply only charging refrigerant gas (R-22) suitable for package type AC plants complete all as specified and directed. (Make: Mafron22/Refron22/Floron22 as approved)
S&F for angle lamp holder, insulated body with back plate for batten fittings including LED lamp 10 watts complete all as specified and directed.
S S ENTERPRISE
M/S PAUL CONSTRUCTION
MAZUMDER AND CO
M/S. ARUP KUMAR DEY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .