Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.8 LAccepted-Finance | ₹5.8 L | 1 | Accepted-Finance Lowest, Accepted |
| 2 | 2₹6.1 L+₹30,580 (5.25%)Rejected-Finance | ₹6.1 L+₹30,580 (5.25%) | 2 | Rejected-Finance Not Lowest, Rejected |
| 3 | 3₹6.2 L+₹35,080 (6.02%)Rejected-Finance | ₹6.2 L+₹35,080 (6.02%) | 3 | Rejected-Finance Not Lowest, Rejected |
| 4 | Not Admitted-Finance X111 357 J K TOWER NH 544 METRO PILLAR NO 138 AMBATTUKAVU ERNAKULAM KERALA 683106 ERNAKULAM KERALA 683106 UDYAM KL 02 0021054 32AACPX5752G1ZM R M | ERNAKULAM | KERALA | 683106 | - | - | Not Admitted-Finance Others-Technical needs doesn't meet |
Tender Value
₹6.2 L
EMD Value
₹15,488
Closing Date
25 Jan 2024, 5:00 pmClosed
General Manager, District Nirmithi Kendra
District Nirmithi Kendra, Anandashram P.O., Kanhangad, 671531
Supply, Installation and Commissioning of RO Plant (2000 Lph) for 8 bedded Dialysis unit at PHC Ajanur
2024_DNKK_643008_1
DNK/KSD/TEN/2/2024
Open Tender
Civil Works - Others
Item Rate
60 days
Ajanur, Kanhangad, 671531
Contractors who have been completed a single similar
work above Rs.6 Lakhs or 2 works above 3 Lakhs within
the last 5 years in Kerala. Certificate from the
competent authority should be produced.
6 documents required · 6 mandatory
₹1,239
Yes
₹15,488
Yes
11 Apr 2024
11 Jan 2024
27 Jan 2024
11 Jan 2024
25 Jan 2024
11 Jan 2024
11 Jan 2024 - 25 Jan 2024
Amount
RO Plant 2000 L
I. RO Plant – 2000 ltrs a. Sand Filter – Capacity – 4000 lph, Media – Sand / Pebbles, MOC – FRP / Composite, Backwash : Automatic, Multiport valve : Timer based with 3 cycle backwash sequence, Pressure gauge and fittings – 1 set. b. Activated Carbon Filter ted Carbon Filter ted Carbon Filter ted Carbon Filter – Capacity : 4000 lph, Media:Carbon ID 900, MOC : FRP / Composite, Make: Pentair / equal, Backwash : Automatic, Multiport valve : Timer based with 3 cycle backwash sequence, Pressure gauge and settings : 1 set c. Water softner – Capacity : 2000 lph, Media : Ion exchange resins ( ion exchange / thermax or equivalent), Regeneration: Automatic, Multiport valve : Timer based with 3 cycle backwash/regeneration sequence, Pressure gauge and settings : 1 set NOT NECCESSARY d. MEMBRANE ELEMENTS – Sufficient quantity and arrays to satisfy the output condition of 2000 LPH at 50-75% rejection for the given water quality. e. Antiscalent dosing system : Capacity : 3 lph, MOC : PP, Dosing tank : 50 ltrs, Level switch and fittings – 1 set.(appropriate for a RO Plant of 200 LPH) f. UV Lamp with SS 304 Housing with quartz reflectors. Flow rate 2000 LPH g. The vessel size shall be at least 13” x 54” II. WATER STORAGE TANK a. Raw water storage tank sintex capacity 4000 Litres (White color tank). b. Softened water tank sintex or equivalent, capacity 2000 Litres (White color tank). c. RO Water storage tank should be stainless steel SS304 – 1000 Litres – 2nos III. PUMP. a. Raw water pump – 1 HP (1+1) – Crompton / Grundfos or equivalent. b. Softened water booster pump – 1 HP (1+1) – Crompton / Grundfos or equivalent. c. SS RO Distribution Pump – 1 HP (1+1) – Crompton / Grundfos or equivalent. IV. OTHERS 1. Should have 1 Micron pre-filter, 20 inch height and 4” diameter. 2. Should have automatic inlet shut-off valve 3. Should have Permeate and Concentrate flow meters. 4. Should have Digital display of critical parameters through range of sensors. 5. Should have User friendly RO controller and ensure automatic trouble free operations. 6. RO controller should have automatic and manual mode. 7. Should have automated pre treatment for RO. 8. Should have Salt rejection around 96 – 98%. 9. RO recovery range shall be 50-75% 10. Permeate Rate : 2000LPH, Concentrate Rate : 2000 – 2200LPH 11. Should have P.E flexible tubing used to collect permeate into RO tank. 12. Should have Thermal motor protection. 13. Should have Pre-filter, post filter, primary and final pressure gauges. 14. Should have Flow control centre including concentrate and recycle valves. 15. Should have Auto flush valve in reject line. 16. Should have Low inlet pressure switch before HPP 17. 3 way Solenoid valve in feed before HPP. 18. Inlet shutoff solenoid valve in smaller system 250 to 1000lph. 19. Glycerin filled SS pressure gauges at feed / high pressure / reject lines. 20. Panel mounted Rotameter in reject / re-circulate and permeate lines. 21. Ball check valve in recirculation line, Spring check valve in permeate line & Conductivity meter in permeate line & Globe /needle valves in re-circulate and reject lines. 22. Should have 5 micron cartridge filters big blue in feed line. 23. Should have Digital conductivity meter with programmable relay 24. Should have Alarms for Low Inlet pressure & Motor starter overload. 25. Frame shall be made of stainless steel – 304 grade 26. Membrane housing shall be made of stainless steel 304 grade or FRP. 27. Inlet plumbing shall be Sch 80 PVC. 28. High pressure plumbing shall be Reinforced rubber hose. 29. Permeate / concentrate tubing shall be Polyethylene / NSF approved wet parts. 30. PEX Piping with SS push pull connectors. 31. Should operate on mains 400-420Vac, 50 Hz three phase power supply. 32. All wetted parts should be INERT, SS or compatible to Haemodialysis procedure. 33. Control enclosures should be NEMA 1 & Motor starters should be NEMA 4 X 34. The outlet of the RO system must conform to AAMI standards both in terms of chemical contamination and bacterial contamination. The endotoxin limit for the RO water is 1 Eu/ml and the limit of bacterial growth shall be not more than 200CFU/ml. Copy of Certificate / test report should be produced along with the technical bid 35. Should supply Test kit for Checking hardness of water / portable TDS Meter. 36. Replacement of all necessary filters including 1 micron & 5 micron, Replacement of Sand / Pebbles / Carbon, UV Lamps, Antiscalent chemical, and Acetic acid cleaning whenever requires should be done free of cost during the warranty period and also in the CMC period. 37. RO Membrane shall be replaced at free of cost during the warranty period whenever required. The replacement charge for RO Membrane replacement during CMC period shall be included in the CAMC rates.
HYDROXY WATER TECHNOLOGIES PVT. LTD.
MEDITECH CORPORATIONS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .