Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹21.3 L+₹1.5 L (7.61%)Accepted-Finance VIKRAM COACHING GALI SUDAMA NAGARI MADI NATH BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L2 | Accepted-Finance ok | |
| 3 | L3₹23.2 L+₹3.4 L (17.2%)Accepted-Finance | L3 | Accepted-Finance ok | |
| 4 | L4₹25.0 L+₹5.2 L (26.2%)Accepted-Finance | L4 | Accepted-Finance ok | |
| 5 | L5₹26.0 L+₹6.2 L (31.3%)Accepted-Finance | L5 | Accepted-Finance ok |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
8 Feb 2022, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR /MAINT OF EXTERNAL ELECTRIFICATION UNDER GE WEST BAREILLY
2021_MES_498057_1
8013/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹60,000
Yes
12 Feb 2022
29 Dec 2021
10 Feb 2022
29 Dec 2021
8 Feb 2022
13 Jan 2022
29 Dec 2021 - 12 Jan 2022
Amount
Taking Out of servo voltage stabilizer of capacity 100 to 300 KVA 3 Phase 4 wire AC 50 Hz 440 volts for unbalance/balance type load , oil cooled from foundation after disconnecting all electrical connection etc. . Dismantling for pre inspection by lifting of assembly and repair/ replacement of worn out parts and testing after reinstallation on same foundation. Note: Major parts required for replacement shall be measured and paid separately under relevant items.
Supply and fixing dimmer set as per existing cap (150 Amp) oil cooled single pole
S & F Carbon brush
S&F Control Motor
S & F electronic PCB Card (Sensing Control Card) as per existing model and type
S & F auxiliary pulse transformer heavy duty
S& refilling Transformer Oil
Repair to LT panel of any size in different location with arc/gas welding with replacement of hinges and place the door in original position, replacement of door locks and replacement of indicator lamp (1 set) rotary switch including painting complete with two coat synthetic enamelled paint over red oxide primer complete all as specified
Dismantling of LT PCC/steel tubular pole/stay assembly/street light of any size and discription incl coping, foundation etc and dismantling of serviceable insulators from poles for reuse and shifting to E/M yard or any other location.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
M & L for earthing complete in replacement , chemical type with copper earth plate electrode 90cmx60cmx5mm thick buried directly in ground (earth pit not less than 3 mtr deep 1.5 mtr width ) with top edge of the plate not less than 2.25 mtr below normal ground level connected and including to and including copper strip earth lead 32mm x 6 mm size by means of copper brazing strip and layers of salt charcol and magnisium sulphate including funnel with wire mesh including funnel with wire mesh including testing of earthing all as specified and directed . (Minimum three chemical pits are to be made and connected in a grid to meet the earth resistance specifications of <0.50ohm) (a) Earthing to be done in presence of JE/Engr- in - Charge .(b) Charcol small pieces 250 Kg , Salt (crystel)-250 Kg , Magnisium Sulphate ( Crystal) 100 Kg. (c) Copper strip shall be brazed with copper elctrode plate .(d) Alternate layer of charcol and salts should be laid in the earth pit on the top of the copper plate at least 5 layers should be laid. (e) After laying of the 5 alternate layers of charcol and salts a two inch layer of magnisium sulphate to be laid. (f) The chemical salts and and magnisium sulphate should not be fixed but are to be laid in layers only. (g) Copper strip is to be extended inside the equipment and power room it should be routed in the side wall of the under ground ducts fixed with cremics /porcelain spacers. (h) Contractor shall pour sufficient water in earth pit before and after doing earthing. (j) 25 mm dia GI pipe suitable length to be reach just about copper plate fitted with funnel meshed along with cap running with water tap to be provided for keeping soil wet. (k) Soft soil ( Black cotton soil) shall be used in case of rocky terrain. (i) Brass nuts and bolts with proper washer to be used for copper strip jointing and necessary brazing shall be done directed. (m) Copper strip beyond 7.5 m shall be measured and paid seperately. (n) The test point of each pit shall be made as directed and the cost is same to be include in the qouted rate. (o) The test report should be submitted in triplicate. ( p) Construction of earth pit chamber with PCC (1.3.6) type C1 ( using 20mm gradeed stone aggregate) RCC 1.2.4 type B1 cover 50mm thick with 8mm dia TMT bar 100mm centre to centre with igting handles of suitable dia complete all as directed . Note: Earth resistance to be less than 1.00
Supply, fabricating and fixing in replacement of cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint all as directed by Engineer-in-charge.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces including broken of existing PCC all as specified & directed.
All as per srl item No above here-in-before but PCC 1:3:6 type C-2 as in foundation of stays and coping of poles.
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for underground cables complete including bricks all as specified & directed.
Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches/ducts complete all as specified & directed.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/lengthwise perpendicular to the axis of cable all as specified & directed.
S&F in repair Cable end termination 11000 volt high voltage (heat shirnkable) cable jointing kit for 1000 Volts (Earthed) grade cable for indoor /outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
All as per above here-in-before but size of 120 to 185 sqmm complete all as specified and directed.
S&F in repair Straight through 11000 volt high voltage (heat shirnkable) cable jointing kit for 11000 volts ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of of size 120 to 185 sqmm complete all as specified and directed.
All as per above here-in-before but size of 95 sqmm complete all as specified and directed.
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 Sqmm 3 core laid in trenches/ducts, fixed on Pole/inside panel, drawn through pipe all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
_ditto- all as above here in before but 120 Sqmm 3 core
Supply installed testing and commissioning of Air-break, gang operated, triple pole switch, outdoor, vertical mounting type (ISI marked), mechanically operated, mounted on insulators 12 nos including 400 amp rating complete with (DO Fuse unit) fuse mounts, fuse carriers and HT fuse elements and frame work with operating mechanism worked from ground level, with locking arrnagments including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections, complete all as specified and directed
Supply and laying in replacement XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sq mm 4 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
All as per Ser item No 20 here-in-before but 16 Sq mm 4 core
All as per Ser item No 20 here-in-before but 25 Sq mm 4 core
All as per Ser item No 20 here-in-before but 50 Sq mm 3.5 core
All as per Ser item No 20 here-in-before but 95 Sq mm 3.5 core
All as per Ser item No 20 here-in-before but 120 Sq mm 3.5 core
All as per Ser item No 20 here-in-before but 185 Sq mm 3.5 core
Supply and fixing 1100 volt grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections , twin core cable flat or circular of size 10 Sqmm all as specified.
Taking down u/s MCCB 4 pole 630 Amp 415 Volt and S & F in replacement MCCB 415 Volts 4 pole 630 Amps 50 Hz 50 KA of existing make model and type alongwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor
All as per Item above but of MCCB 500 Amps 4 pole 50 Hz 415 V with rupturing capacity 50 KA
All as per Item above but of MCCB 400 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA
All as per Item above but of MCCB 315/350 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA
All as per Item above but of MCCB 250 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA
All as per Item above but of MCCB 200 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA
All as per Item above but of MCCB 160 Amps 4 pole 50 Hz 415 V with rupturing capacity 16 KA
All as per Item above but of MCCB 100 Amps 4 pole 50 Hz 415 V with rupturing capacity 16 KA
Taking down of old aluminium conductor of any description /size from LT Poles including cross arms, bracing and other steel accessories.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Supply and fixing/laying of galvanized iron strip of size 32x6 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed.Note: Making of earth test point is also included in the quoted rate.
M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.
M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a) 50 mm dia
(b) 80 mm dia
Supply and fixing of PVC LT OH line spacer for 3 wires complete all as specified and directed.
Supply and fixing of PVC LT OH line spacer for 4 wires complete all as specified and directed.
Supply and fixing of PVC LT OH line spacer for 2 wires complete all as specified and directed.
Removal of Tree fallen on HT/LT overhead lines by cutting branches,bushes by electric cutter or manual and lifted by crane /Hydra/Manual including collection and depositing the retrieved timber at a place as directed by Engineer-in-charge.
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: (i) The above work includes clearing /prooning of tree branches falling around the conductors. (ii) Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid.
Opening the binding wire from 'J' hook or opening nut, bolts,of cross arms on steel /pole of any height for re-stretching the galvanised iron earth wire any size, after re-restretching without kinks & bends, binding the 'J' hook with appropriate size of aluminium binding wire or fixing with appropriate size of nut,bolts,washers complete all specified & directed by Engineer-in- charge. Note: (i) Cost of binding wire,nut,bolts and washers deemed to be included in the quoted rate, No extra amount will be paid.
Supply, fixing, testing and commissioning of heat shrinkable type straight through jointing kit suitable for LT cable of size 35 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade. Make :- ENSON/ M-SEAL/ FRONTEC
All as per above here-in-before but 95 to 120 Sqmm.straight through jointing kit
All as per above here-in-before but 150 to 185 Sqmm. straight through jointing kit
Supply, fixing, testing and commissioning of Heat shrinkable type end termination jointing kit suitable for LT cable of size 35 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade. Make :- ENSON/ M-SEAL/ FRONTEC
All as per above here-in-before but 95 to 120 Sqmm.end termination jointing kit
All as per above here-in-before but 150 to 185 Sqmm.end termination jointing kit
Supply& fixing in repair PVC jumper cable of size 70 Sqmm aluminium,single core suitable for 1100 volts and removing the old burnt/ worn out jumper complete all as directed by the Engr-in-Charge.
All as per item above here-in-before but size 95 Sqmm.
M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm and rating 600 amp fixed on porcelain insulators TPN type out door weather/vermin proof with both way open ing duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 35 KA 4 Pole complete all as sepcified and directed incl making connection /thimbles etc complete.
All as per srl item above here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB and bus bar rating 400 amp
Supply and fixing street light bracket made out of 40 mm dia GI pipe light grade of length upto 1.2 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the over head lines conductor upto 3 mtr from furthest conductor on pole and pole to pole one span including removing of cut branches and cleaning of site complete all as specified and directed. Note :- (a). The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b). Prooning of all tree branches in one tree shall be measured as one Job. c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f). The contractor will provide proper tools and safety devices to his staff for prooning of trees.
Cleaning of surrounding areas from large grass weeds ,vegetation, shrubs branches of trees at substations, near Transformers ,near Electric pole structures by manual /Electric Grass cutting machine/JCB etc with complete grass and vegetation clearance from ground without any damage to the electric cables and items complete all as specified and as directed by Engr-in-Charge. Notes: Rates of T&P must be included in the quoted rates
Cleaning and preparation of old painted surface of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets,street light brackets.cross arms and making Red & white strips with synthetic enamelled paint of 30cm height,each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified
M&L for laying for coarse agregate of 25 to 40 mm (broekn) in MRS including taking out of old concrete/stone upto 300 mm depth or as per specified by Engr-In-Charge.
M/s. S.S. Refrigeration, Bareilly
M/s Yash Trading Company
Ishtiaq and Sons
LEEJA ENTERPRISES
VINYAK TRADERS
M/S MAHIRA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .