Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED L1 | |
| 2 | L2₹20.7 L+₹1.8 L (9.33%)Rejected-Finance SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L2 | Rejected-Finance Being rejected L2 | |
| 3 | L3₹21.4 L+₹2.4 L (12.9%)Rejected-Finance | L3 | Rejected-Finance Being rejected L3 | |
| 4 | L4₹22.7 L+₹3.7 L (19.6%)Rejected-Finance 122 SAMHARIYA ASOPUR TANDA AMBEDKAR NAGAR UTTAR PRADESH 224190 | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | L4 | Rejected-Finance Being rejected L4 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Dec 2022, 6:00 pmClosed
SHRI ABHINANDAN KUMAR MISHRA EE IDSE
GE SOUTH AMBALA CANTT
WELCOME MAINT AND MISC B AND R WORKS OF JOINERY, PLUMBING, FLOORING AND SANITARY FITTINGS TO OFFICERS MARRIED ACCN OF AGE B AND R I (SOUTH) UNDER GE (SOUTH) AMBALA CANTT
2022_MES_562483_1
GE(SOUTH)/AMB-45/2022-2023
Open Tender
Civil Works
Item Rate
270 days
GE SOUTH AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE SOUTH AMBALA CANTT
₹70,000
Yes
22 Dec 2022
11 Nov 2022
10 Dec 2022
11 Nov 2022
8 Dec 2022
25 Nov 2022
11 Nov 2022 - 24 Nov 2022
Amount
Material and labour for preparation of old decorative surface of wall etc by washing rubbing down including scrapping and applying one coat of cement base paint of any tint complete all as specified and directed.
Material and labour for preparation of old decorative surface of wall including washing rubbing down and stopping of distempered and painted surfaces and applying one coat of oil emulsion paint complete all as specified and as directed.
Material and labour for preparation of old decorative surface of ceilings etc by washing rubbing down etc and applying one coat of oil emulsion paint complete all as specified and directed.
Material and labour for complete removal of existing treatment on surface of walls by using appropriate technique as approved by Engineer-in-Charge for complete removal of all layers of treatment and reaching upto old plastered surface and applying a coat of wall care putty not less than 1mm thick as per manufacture instructions and applying two coats of oil emulsion paint over a coat of primer complete all as specified and directed.
Material and labour for preparation of old decorated surfaces of walls including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. including cornices, pilasters etc. (Plastered or unplastered surfaces) and applying one coat of exterior plastic emulsion coloured complete all as per manufacturers instructions and as directed.
Material and labour for preparing surfaces old plastered surfaces of walls and applying one coat of colour washing complete as all specified and directed.
Material and labour for preparing surfaces old plastered surfaces of walls and applying one coat of white washing complete as all specified and directed.
Preparation of old treated surfaces (Plastered or un-plastered) of ceiling by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss, efflorescence salts, treating oil and greasy spots etc. and applying one coat of white wash on ceiling, complete all as specified and directed.
Material and labour for preparation of old wood and wooden based surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel complete all as specified and directed.
Material and labour for preparation of old wood and wooden based surfaces of any description not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel complete all as specified and directed.
Material and labour for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Material and labour for preparation of old painted steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed.
Material and labour for 15mm thick rendering in cement mortar (1:4) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement including taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
Material and labour for 15mm thick rendering in cement mortar (1:6) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement including taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
Material and labour for 5 mm thick rendering in cement mortar (1:3) on soffits of slabs etc ceiling surface and finished the surface even and smooths including taking down existing cement plaster including racking out joints,hacking for key, scrubbing down with water etc. complete all as specified and as directed.
Material and labour for 18 to 20mm thick Granite stone of black shade work (table rubbed, polished & moulding), as in floors, cooking platforms and like bedded with and including 15 mm thick screed bed in CM (1:4) and jointed with grey cement slurry @ 3 Kg/Sqm, and pointed with white with admixture of pigment to match with shade of granite stone including grinding and polishing including dismantling of existing stone slabs including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for 18 to 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, skirting, on vertical surface and like in 10mm thick rendering in CM (1:3) and jointed with grey cement slurry @ 3 Kg/Sqm, and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding, moulding and polishing on edges etc including dismantling of existing stone /tiles etc including cement mortar bedding and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, 7 to 8 mm thick as in floor, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or layer in cement mortar (1:4) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, 7 to 8 mm thick as in vertical surfaces such as dado, skirting, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 10 mm thick rendering in cement mortar (1:4) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, 8 to 9 mm thick as in floor, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or layer in cement mortar (1:4) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, 8 to 9 mm thick as in vertical surfaces such as dado, skirting, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 10 mm thick rendering in cement mortar (1:4) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed as in neat, neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or layer in cement mortar (1:4) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in vertical surfaces such as dado, skirting, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 10 mm thick rendering in cement mortar (1:3) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material & labour for premium quality coloured glazed ceramic tiles (300x 450x 7 to 8mm thick) as in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the shade of tiles over and including rendering 10mm thick in cement plaster 1:3 finished rough surface to receive tiles including dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Supply and fixing of GI tubing, ISI Marked, 15mm bore, `medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors including necassary cutting/chasing/pinning in wall and making good the disturbed surfaces as per existing whereever required, including taking down of old tubing as existing at site and removal, complete all as specified and as directed.
Supply and fixing of GI tubing, ISI Marked, 20mm bore, `medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors including necassary cutting/chasing/pinning in wall and making good the disturbed surfaces as per existing whereever required, including taking down of old tubing as existing at site and removal, complete all as specified and as directed.
Refixing old serviceable steel water tubing of 15 mm bore, in new or old position, any grade, including S& F new fittings as required, fixed to walls and ceilings or laying in floors including necassary cutting/chasing/pinning in wall and making good the disturbed surfaces as per existing whereever required , including taking down of old tubing as existing at site and removal, complete all as specified and as directed
Refixing old serviceable steel water tubing of 20 mm bore, in new or old position, any grade, including S& F new fittings as required, fixed to walls and ceilings or laying in floors including necassary cutting/chasing/pinning in wall and making good the disturbed surfaces as per existing whereever required , including taking down of old tubing as existing at site and removal, complete all as specified and as directed
Supply and fixing of water storage tank of 500 ltr capacity, HDPE triple layer, cylindrical, vertical with closed top and FDA approved, 100% UA stabilized, rust proof, ISI marked, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm high pressure with polythene float and flynut, ISI marked, screwed and suitable for iron pipe 20 mm bore including taking down of old tank of any descrption and removal from site complete all as specified and directed. Note:- Tank shall be white and make of tank shall be engraved on the tank.
Supply and fixing of water storage tank of 1000 ltr capacity, HDPE triple layer, cylindrical, vertical with closed top and FDA approved, 100% UA stabilized, rust proof, ISI marked, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm high pressure with polythene float and flynut, ISI marked, screwed and suitable for iron pipe 20 mm bore including taking down of old tank of any descrption and removal from site complete all as specified and directed. Note:- Tank shall be white and make of tank shall be engraved on the tank.
Supply and fixing in repair of stop valves, cast copper alloy ISI marked screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unions, suitable for 20 mm bore tubes, complete all as specified.
Supply and fixing in repair of stop valves, cast copper alloy ISI marked screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unions , suitable for 15 mm bore tubes, complete all as specified and directed.
Supply and fixing in repair of 15mm fancy type, chromium plated, angle valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle, heavy with adjustable wall flange, complete all as specified and directed.
Supply and fixed in repair of stop cock, fancy type, chromium plated, long shank and cup (concealed type) screwed down high pressure with crutch or butterfly handle screwed both ends suitable for 15mm bore pipe, complete all as specified. (Note : Weight of stop cock shall not be less than 0.575 Kg).
Supply and fixed in repair of CP bib tap screwed down high pressure, long body, cast copper alloy, chromium plated` with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union, complete all as specified. (Note : Weight of bib tap shall not be less than 0.575 Kg)
Supply and fixing in repair of vitreous chainaware Dome (S-30) concealed floor trap mounted, starwhite colour, EWC pedestal pattern alongwith and including premoulded vitreous china ware cistern, seat cover complete all as specified and directed.
Supply and fixing in repair of vitreous china wash down water closet pedestal pattern (EWC), White including connection to trap and to flushing pipe with ‘P’ or ‘S’ trap, making good to floor, plastic water closet seat cover with mild steel chromium plated hinges and chromium plated jet spray with 1.5 meter flexible LDPE pipe jointed with pipe complete all as specified and directed.
Supply & fixing (in repair) of vitreous china wash hand basin white flat back of size 550x440mm including CI brackets and 15mm chromium plated pillar tapc ast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks, PVC connection 450 mm long having PTMT nuts and chromium plated waste coupling and making good to disturbed portion including 32 mm dia PVC waste pipe etc., complete all as specified and directed.
Supply and fixing (in repair) of 10 litre capacity flush polypropylene cistern, ISI marked, white at low level complete with PVC bend/flush pipe and making all connection including taking down existing high/low level cistern with all connections and making good the disturbed surfaces in cement mortar (1:3) to match with the existing surface, complete all as specified and directed.
Supply and fixing (in repair) of WHB mixer (hot & cold), cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts, fancy type screwed for iron pipe and fixed bore of pipe 15 mm, complete all as specified and directed.
Supply and fixing (in repair) of PVC connections 45cm long and 15mm dia with PTMT nuts and PVC washers on both ends, complete all as specified and as directed.
Supply and fixing (in repair) of PVC waste pipe 32/40mm bore suitable for WHB/ Sink etc complete all as specified and as directed.
Supply and fixing in repair of wall mixer (Hot & old), cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts, fancy type screwed for iron pipe and fixed bore of pipe 15 mm, complete all as specified and directed.
Taking down chowkats or frames with shutter, area not exceeding 1.50 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish complete all as specified and directed.
Taking down chowkats or frames with shutter, area exceeding 1.50 Square metre but not exceeding 4 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish complete all as specified and directed.
Taking down shutter of any descritption not exc 1.00 sqm each including removal from site complete all as specified and directed.
Taking down shutter of any descritption exc 1.00 sqm each but not exc 2.00 sqm each including removal from site complete all as specified and directed.
Supply and fixing of pressed steel frames for doors of size 125 x 60mm, 1mm thick, with one or more rebates including, hold fasts of 25mm x 4mm FI, 25cm long, 6 Nos in each chowkhat, necessary lugs, 3 Nos 100 mm MS butt hinges medium weight, cold rolled, welded for each shutters of frame, lock strike plate, including sanding, tarring backs of chowkhats, PCC 1:3:6 type C-0 filling in frame and for holdfast, 2 Nos 12 mm dia MS tie bars at the bottom of frame and one shop coat of red oxide primer etc complete all as specified and as directed.
Supply and fixing of factory made 35 mm thick, second class hard wood rail and style, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commrcial veneering on both faces ace, size of rails and stiles as per IS 1003 (part-I) kiln seasoned and chemical pressure treated complete all as specified and directed.
Supply and fixing of 2nd class hard wood factory made 35mm thick glazed skelton door shutters, open rebated and prepared to receive glass, gauge etc. divided into squares edges of framing, plain, chamfered or rounded, mitred fitted with cut and mitred beads for securing glass/gauge etc. with sizes of members of shutters as specified in para 8.24(a) of SSR 2009 (Part I), complete all as specified and directed.
Supply and fixing factory made PVC hollow door frame of size 50mm x 47mm with wall thickness of 5 mm made out of extended 5 mm rigid PVC foam sheet cut at corner and jointed with 02 Nos, 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided through out the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos of screws to be provided for each vertical numbers & minimum 02 Nos for horizontal member) complete all as specified and directed.
Supply and fixing of factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with 2, 4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face including fixing in frame at site with 03 Nos SS hinges, 02 Nos aluminium tower bolt 150 mm, 02 Nos aluminium handle 150 mm for each shutter all as per specification & drawing complete all as specified and directed.
Supply and fixing of steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing No. TD-219(c) sheet 1/3 to 3/3 and TD-220(c) sheet 1/3 to 3/3 as applicable including PCC(C-O ,1:3:6 using 12.5 graded agg) bed blocks for hold fasts and one shop coat of red oxide primer etc complete all as specified and directed. Note: (i) For the purpose of measurement & payment double shutter with frame shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery , grills 10mm square bars. (iii) Only Glazing, wire mesh & painting grill shall be measured & paid for separately)
Supply and fixing in repair of steel ventilator of section framed fixed type and fixed wire mesh with flat bends 10 mm x 3 mm with nuts / bolts including PCC (C-O,1:3:6 using 12.5 graded aggregates) bed blocks for hold fasts if required complete all as specified and directed.
Supply and fixing of sheet glass 3mm thick, ordinary quality , in square not exceeding 0.5 Square metre each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters, complete all as specified and as directed.
Supply and fixing of galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with stainless steel wire staple or fixing with beads to joinery when fixed in panels of joinery, complete all as specified and directed.
Supply and fixing in repair of galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staple or fixing with beads to joinery when fixed in panels of joinery, complete all as specified and directed.
Supply and fixed (in repair) of sheet glass 3mm thick, ordinary quality and glazing with oil putty, in square n.exc 0.5 Sqm each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters, complete all as specified and as directed.
Supply and fixing of butt hinges, medium weight, cold rolled, mild steel, ISI marked 100 mm size complete all as specified and directed.
Supply and fixing of 150mm long extruded aluminium alloy handles, fabricated type, anodised complete as specified and directed .
Supply and fixing of 200mm long aluminium anodised barrel tower bolts of extruded section complete as specified and directed.
Supply and fixing of 300 mm aluminum anodised sliding door bolt, ISI marked, with hasp, staple (bolt type) complete with clamps bolt not less than 16mm dia and fixing clips of sheet, cast or extruded section and fixing bolts an sliding bolt of extruded section or cast aluminum alloy, complete all as specified and as directed.
Material and labour for preparing new or previously untreated wood or wooden surfaces of any description not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; and similar work conforming to Fe-410-O or Fe-310-O including dismantling existing mild steel work of any description complete all as specified and directed.
Supply and fixing of factory made 28 mm thick PVC moulded door shutter as in kitchen cabinet with particle board core, with 2mm thick moulded pre laminated PVC sheet on the front face and 2mm plain colour PVC sheet on back face, 5 mm x 25 mm PVC sheet beading on either side including two Nos. aluminium hinges for each door complete all as per manufacturer instructions including dismantling existing boards including frame etc of any description complete all as specified and directed.
Supply and fixing of factory made PVC hollow as in kitchen cabinet frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of extended 5 mm rigid PVC foam sheet, reinforced with steel square tube, complete all as specified and directed.
Supply and fixing in repair of mild steel helical door spring 150 mm long fixed with screws to wooden chowkhats or welding to steel chowkhats, complete all as specified and directed.
Supply and fixing of 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in , cup board shelves etc including dismantling boarding, any description, fixed in any position with nails etc; complete all as specified and directed.
Description all as per item 69.00 above but over Decorative laminates 1.5 mm thick type I, or surface finish, colour and pattern (sunmica) as approved complete all as specified and directed.
Supply and fixing in repair of 12mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed.
Supply and fixing in repair of mild steel harrison rail, chromium plated with fixed brackets, stops, rollers etc complete all as specified.
Supply and fixing in repair of aluminium pre coated of choice colour designed type 25 mm tubular rod in curtain rod, 1.6mm fancy type including PVC golden colour brakets, latto and wall to wall socket etc., complete all as specified and directed.
Supply and fixing in repair of stainless steel plate rack size (900x900mm) of standard size, weight not less than 5kg, complete all as specified and directed.
Supply and fixing (in repair) stainless steel sink with drainage board 1.00 mm thick, ISI marked for kitchen with plug, washers and wastes, including bedding in cement mortar on to dwarf wall or fixing contilever brackets of suitable angle iron, CP brass waste coupling, superior quality PVC waste pipe and connecting union to pipe, over all size 915mm x460mm, bowl size 410mm x 330mm x160mm fixed in repair complete all as specified and directed.
Supply and fixing in repair of CP grating 75 mm dia with or with out hole complete all as specified and directed.
Supply and fixing in repair of CP grating 100 mm dia with or with out hole complete all as specified and directed.
Supply and fixing (in repair) of PVC seat cover with hinges for EWC complete all as specified and directed.
Supply and fixing in repair of CP Hand shower (Health faucet) including 1.50 meter long flexible tube. complete all as specified and as directed
Supply and fixing in repair of CP Jet spray for with 1.5 mtr long pipe fixed in EWC complete all as specified.
Supply and fixing of PVC (SWR) 110 mm bore soil, waste and vent pipe single socket in any length with rubber ring joints laid in floors or trenches including dismantling of existing pipes of any description any length complete all as specified and as directed.
Supply and fixing of PVC (SWR) 75 mm bore soil, waste and vent pipe single socket in any length with rubber ring joints laid in floors or trenches including dismantling of existing pipes of any description any length complete all as specified and as directed.
Supply and fixing of PVC (SWR) 110 mm pipe single socket in any length with rubber ring joints fixed to wall with MS clamp etc including dismantling of pipes of any description any length including bends etc complete all as specified and as directed.
Supply and fixing of PVC (SWR) 75 mm pipe single socket in any length with rubber ring joints fixed to wall with MS clamp etc including dismantling of pipes of any description any length including bends etc complete all as specified and as directed.
Supply and fixing of PVC (SWR) bends 110 mm bore complete all as specified and as directed.
Supply and fixing in repair of PVC (SWR) junction single, (Single T) equal or unequal of radius 110 mm bore. complete all as specified and directed.
Supply and fixing in repair of PVC (SWR) floor trap, plain with grating including jointing with solvent cement of outter diameter outlet of 75mm complete as specified and directed.
Supply and fixing of 5 mm thick plain colour PVC sheet, solid PVC wall paneling/ lining PVC sheet inclusive of solvent cement and fixing at site including 5 mm thick PVC sheet fillets of width 35 mm for wall paneling inclusive of fixing on wall to make PVC frame as per specification and directed including taking down of existing wall lining, board or insulation board including cover fillets of any type and thick complete all as specified and as directed.
Running welding in repairs thickness of metal to be welded not exceeding 6 mm including cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, as required, in the case of metal exceeding 3 mm thick complete all as specified and as directed.
Cleaning and removing all scale and dirt, etc from existing water storage tanks of capacity exceeding 250 litres and not exceeding 500 litres by emptying, drying and cleaning the tank by scrubbing the dust with wire brush from tank including cleaning from mouths of circulating pipes, to entire satisfaction of Engr-in–charge of cleaning, including writing date of cleaning with oil paint of of visible colour in font size not less than 100 mm high complete all as specified and directed. (The rates includes for disconnecting of existing water tank, lowering if required and hoisting, reconnecting and refixing in same position after cleaning ) NOTE: - (i) The whole process of disconnecting, reconnecting and refixing in same position after cleaning shall be done on the same day, if failing so, Rs. 100/- shall be deducted for each tank per day from the contractor due. (ii) A separate register to be maintained by contractor for cleaning and occupant signature with date to be obtained in it.
Cleaning and removing all scale and dirt, etc from existing water storage tanks of capacity exceeding 500 litres and not exceeding 1000 litres by emptying, drying and cleaning the tank by scrubbing the dust with wire brush from tank including cleaning from mouths of circulating pipes, to entire satisfaction of Engr-in–charge of cleaning, including writing date of cleaning with oil paint of of visible colour in font size not less than 100 mm high complete all as specified and directed. (The rates includes for disconnecting of existing water tank, lowering if required and hoisting, reconnecting and refixing in same position after cleaning ) NOTE: - (i) The whole process of disconnecting, reconnecting and refixing in same position after cleaning shall be done on the same day, if failing so, Rs. 100/- shall be deducted for each tank per day from the contractor due. (ii) A separate register to be maintained by contractor for cleaning and occupant signature with date to be obtained in it.
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 93.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 93.00 above but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 93.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH PVC insulated and unsheathed stranded cable drawn through and including existing non metallic/mettalic heavy duty concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over flush boxes /sunken boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed. NOTES : - (i) Point wiring & earth wire shall be connected to each & every flush/sunken box. (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 97.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 97.00 above but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 97.00 above but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Supply and fixing of modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing of modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing of modular switches, one way, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed.
Supply and fixing of modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fixing of modular socket outlet 16 amps,6 pin , combined 2 module, complete all as specified and directed.
Supply and fixing offan regulator step type one module / 2 module, 120w 230 Volts, 50 Hz, AC complete all as specified and directed.
Supply and fixing of modular blanking plate 1 module complete all as specified and directed.
Material and labour for concealed point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 25 mm dia with FRLSH accessories, concealed and including provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch complete all as specified and directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates
Description all as per item No 108.00 above but for socket out let point 5 Amps on same board,complete all as specified and directed.
Description all as per item No 108.00 above but for socket out let point 5 Amps on independent board,complete all as specified and directed.
Description all as per item No 108.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed.
Material and labour for Point wiring in exisiting conduit with using approved colour coding as per IS with using 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through existing, PVC conduit with FRLSH )accessories, concealed on wall/ceiling and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators, bell push etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch. NNOTES : - (i) Point wiring & earth wire shall be connected to each & every flush/sunken box. (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 112.00 above but for socket out let point 5 Amps on same board,complete all as specified and directed.
Description all as per item No 112.00 above but for socket out let point 5 Amps on independent board,complete all as specified and directed.
Description all as per item No 112.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed.
Supply and fixing of bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing of switch piano 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing of switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing of socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed.
Supply and fixing of ocket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified.
Supply and fixing of ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fixing of regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed.
Supply and fixing of door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
Supply and fixing of lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified.
Supply and fixing in repair of sheet metal enclosure SP with two pin, earth plug and metal clad socket with one single pole, MCB 32 Amps, 'C' curve, 240 volts complete all as specified and directed.
Supply and fixing in repair of sheet metal enclosure SP with two pin, earth plug and metal clad socket with one single pole, MCB 20 Amps, 'C' curve, 240 volts complete all as specified and directed.
Supply and fixing of sheet metal enclosures distribution board for TPN, (MCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, alongwith TPN 63 Amps MCB as incomer and suitable for MCB s as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement, making connections with suitable size of lugs / thimbles/ glands and gasket alongwith manufacturer test certificate of IP/ IK 09 including taking down existing distribution board and making good the disturbed surface matching with existing surface complete all as specified and directed.
Supply , installation, testing of SPN distibution board 12 way,double door , IP 43 , as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles & gasket complete all as specified and directed.
Supply , installation, testing of SPN distibution board 8 way,double door , IP 43 , as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles & gasket complete all as specified and directed.
Supply , installation, testing of SPN distibution board 4 way,double door , IP 43 , as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles & gasket complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 16 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of channel for fixing of LED tube rod, aluminium housing body in CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. ( Tube rod shall be measured and paid for separately ).
Supply and fixing of 18 W/ 20W Polycarbonate LED tube light, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. Note: - Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings .
Supply and fixing of surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housing in CRCA body suitable and including 10 watt LED tube high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing wall mounting bracket typr wooden base with finished and disgnied cover of V/opal/spherical shape with and including 9 to 12 watt LED lamp of B22 base including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Disconnecting and taking down old existing wall / surface light fitting of any description and in any position and Supply and fixing surface mounted type metal base with finished and disgnied diffuser of round/ square/ oval shape slim down lighter 12 watt LED including suitable capacity driver complete connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Supply and fixing in repair of bracket for security light made up of 25mm dia, 0.9 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fixing of LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Disconnecting and taking down old existing bed side light fitting (bed side lamp) of any description and in any position and Supply and fixing wall mounting bracket type wooden base with finished and disgnied cover of V/opal/spherical shape with and including 9 to 12 watt LED lamp of B22 base including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Supply and fixing of post top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing of LT 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 Sqmm including all incoming and outgoing connection with proper size of thimble etc. complete all as directed and specified.
Supply and fixing of LT 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 16 Sqmm including all incoming and outgoing connection with proper size of thimble etc. complete all as directed and specified.
Material and labour for taking down ceiling fan, sealing cable end, dismantling blades and removing fan from site and keeping in safe custody for reuse and hanging same ceiling fan of any sweep and connecting up including provision of three core PVC insulated and unsheathed copper conductor cable of size 0.5 Sqmm from ceiling rose or connector to fan complete all as directed.
Material and labour for taking down Exhaust fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair complete all as directed and specified.
Supply and fixing in repair of fan condencer 2.5/ 4 MFD, 240 volts suitable capacity for ceiling/ exhaust Fan complete all as directed and specified.
Material and labour for servicing of ceiling fan including servicing/ varnishing painting of ceiling fan using synthetic enamel paint in two coat over one coat of primer of any make/sweep/model etc after cleaning/washing and fill up cavities using filler including writing MES NO Black Colour complete all as specified and directed.
Material and labour for fixing only exhaust fan any type/ seep after repair/ servicing and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc all as specified and directed.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Supply and fix temperature resistent SS braided pipe suitable to sustaine pressure up to 8 bar not less than 60 Cm long suitable for out going / Hot water connections of Geyser with washer etc. complete as an directed.
Material and labour for replacement of existing rusted metal flush box/ sunken box of 8"x5" size with GI/mild steel sunken box or pressed steel terminal boxes of 8"x5" size made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc and making good the disturbed surface after completion of work all as specified and as directed Note Rate of cutting laminated sheet for fixing ofswitch, sockets, regulators etc shall deemed to be incuded in quoted rate.
Material and labour for replacement of existing rusted metal flush box/ sunken box of 7"x4" size with GI/mild steel sunken box or pressed steel terminal boxes of 7"x4" size made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc and making good the disturbed surface after completion of work all as specified and as directed Note : Rate of cutting laminated sheet for fixing of switch, sockets, regulators etc shall deemed to be incuded in quoted rate.
Material and labour for replacement of existing rusted metal flush box/ sunken box of 4"x4" size with GI/mild steel sunken box or pressed steel terminal boxes of 4"x 4" size made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc and making good the disturbed surface after completion of work all as specified and as directed Note : Rate of cutting laminated sheet for fixing ofswitch, sockets, regulators etc shall deemed to be incuded in quoted rate.
Material and labour for replacement of existing rusted modular metal flush box of 1 to 3 module and fixing of GI flush box of 1 to 3 module for housing of modular switch, sockets, regulators etc including taking down existing flush box and making good the disturbed surface after completion of work all as specified and as directed
Material and labour for replacement of existing rusted modular metal flush box of 4 to 8 module and fixing of GI flush box of 4 to 8 module for housing of modular switch, sockets, regulators etc including taking down existing flush box and making good the disturbed surface after completion of work all as specified and as directed
Material and labour for replacement of existing unservicable modular cover plate with frame of 1 to 3 module and fixing modular cover plate of 1 to 3 module for housing of modular switch, sockets, regulators etc including taking down existing modular cover plate with frame all as specified and as directed
Material and labour for replacement of existing unservicable modular cover plate with frame of 4 to 8 module and fixing modular cover plate of 4 to 8 module for housing of modular switch, sockets, regulators etc including taking down existing modular cover plate with frame all as specified and as directed
Supply & fixing in repair of switch piano 5 Amps, flush type, single pole, one way, 230 volt, AC supply, ISI Marked, complete all as specified and as directed.
Supply & fixing in repair of switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, complete all as specified and as directed.
Supply & fixing in repair of socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as specified and as directed.
Supply & fixing in repair of socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and as directed.
Supply & fixing in repair of switch modular 6 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Supply & fixing in repair of switch modular 16 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Supply & fixing in repair of socket modular 6 amps, 5 pin combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
Supply & fixing in repair of socket modular 6/16 amps, 2 in 1, combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
NOTE:- Amount of credit of Rs. 57,314.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.
JS CONSTRUCTION COMPANY
M/S M S BUILDER AND CONTRACTORS
Shiv Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .