Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹98 L
EMD Value
₹98,000
Closing Date
4 Nov 2024, 5:00 pmClosed
Superintending Engineer
33/11 KV S/S Hospital Chauraha, Bahraich
Turn Key Work against Deposit Scheme under EDD-II, Nanpara
2024_MVVNL_957408_2
45/EDC(B)/2024-25
Open Tender
Electrical Works
Turn-key
90 days
Bahraich
Technical/PreQuel/Tenderform
3 documents required · 3 mandatory
₹3,540
Superintending Engineer, EDC
₹98,000
9 Nov 2024
26 Oct 2024
5 Nov 2024
26 Oct 2024
4 Nov 2024
26 Oct 2024
Amount
All Materials Provided by the Contractor as per Resspo Norms PART-A (Supply)
PCC Pole 8.5 Mtr long
ST Pole 11 Mtr. Long
11/0.4 KV 630 KVA T/F
Stone Pad
11 KV 'V' Type Steel X-Arm
11 KV Pin Insulator with Pin
11 KV Disc Insulator with Fitting
11 KV Disc Insulator 70 KN
11 KV Disc Fitting 70 KN
ACSR Weasel Conductor
ACSR Dog Conductor
Stay Set Complete
Earthing Complete
GI Barbed Wire
Top Channel
AB Cable 3x95+1x70+1x25mm2
Croos Braching Angle
11 KV Cable Jointing Kit O/D
11 KV Cable Jointing Kit I/D
Alluminium Binding Wire
Alluminium Paint
Red Oxide Paint
Earth Wire Clamp
Alluminium Tape
11 KV XLPE Cable 3x120sqmm
PG Clamp for Dog
11 KV Fuse Set
Structure Fuse Set
Structure line & Bus Isolator
Structure for Post Isolator
Structure for LA
Main Bus Bar with Structure
Clamp for Top, Tee Drop, Guard etc
V-Type X-Arm Holding Clamp
Danger Board, No-Plate Bolt with
F-Bracket Clamp
PP Clamp
Number Plate
Terminal Gantry
Line & Bus Bar Isolator
Post Insulator
Lightening Arrestor 11 KV
Distribution Box
MS Nut & Bolt with washer
PART-B (Erection Work)
Fabrication & Erection of Single PCC Pole (8.5 Mtr Long) for 33 KV, 11 KV & HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site with complete fitting. All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
Fabrication & Erection of Single ST Pole (11 Mtr Long) for 33 KV, 11 KV & HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site with complete fitting. All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
Fabrication & Erection of Double PCC Pole (8.5 Mtr Long) for 33 KV, 11 KV & HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site with complete fitting. All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
Fabrication & Erection of Double ST Pole (11 Mtr Long) for 33 KV, 11 KV & HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. All the materials for fabrication shall be arranged by the contractor as per RESPO Norms.
Grouting of Poles with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely. (All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
Supply, Grouting nozzling & binding of stay sets with stay clamp complete fittings. (All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
Earthing Complete at 11/0.4 KV T/F as per RESSPO Norms.
Earthing Complete at HT/LT Pole as per RESSPO Norms.
Boring Type Earthing Complete as per RESSPO Norms.
Laying of Double circuit 11 KV 3x120sqmm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks with Complete Fitting.
Errection & Commissioning of AB cable 3x95+1x70+1x25mm2 including complete fitting of Accessories (All Accessories shall be Provided by the Contractor).
Laying, stringing, sagging, binding & jumpering of conductors of 11 KV in 3 phase, 4 wire guard wire the help of necessory clamp and binding wire proper connector & Clamp (Complete Fitting.)
Laying, stringing, sagging, binding & jumpering of conductors of 33 KV in 3 phase, 4 wire guard wire the help of necessory clamp and binding wire proper connector & Clamp (Complete Fitting.)
Fixing of Cable Jointing kit O/D
Fixing of Cable Jointing kit I/D
High Pressure testing of 11 KV XLPE cable, Testing equipment will be arranged by the contractor.
Fixing of 11 KV Fuse Set Complete as per Resspo Norms.
Insllation of Terminal Gantry as Per Assign Attached.
Cartage & Fixing of 11 KV VCB 200/100/5Amp
Fixing & Installation of Structure for 11 KV Fuse Set as per Resspo Norms.
Fixing & Installation of Main Bus Bar Complete with Structure
Fixing & Installation of Structure for line & Bus Isolator
Fixing & Installation of Structure for Post Insulator
Fixing & Installation of Structure for LA
Fixing of Lightening Arrestor for 11 KV Line
Construction of masonary Plinth suitable for 630 KVA & 100 KVA T/F as per Respo Norms.
Wire Mesh Fencing suitable for 100 KVA T/F as per Resspo Norms.
Wire Mesh Fencing for Covering of 11/0.4 KV Switchyard including 3x630 KVA T/F and all Accessories as per Resspo Norms.
Fixing of Line & Bus Isolator
Fixing of Post Insulator
Fixing of Number Plate
Fixing of Alluminium Binding Wire
Alluminium Painting work (ISI Mark Paint)
Red Oxide Painting work (ISI Mark Paint)
Fixing of Earth Wire Clamp
Fixing of PG Clamp for Dog
Fixing of Alluminium Tape
Mounting & Jumpring of 630 KVA T/F with complete fitting.
Carriage & Mounting & Jumpring of 100 KVA T/F with complete fitting.
Cutting of Tree Branches
Fitting of Three Phase Distribution Box
Anil Kumar Yadav
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .