| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹11.9 L+₹34,542 (3.00%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹12.6 L+₹1.1 L (9.51%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹12.7 L+₹1.2 L (9.99%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹13.4 L+₹1.9 L (16.2%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹14.3 L
EMD Value
₹28,600
Closing Date
17 Jan 2020, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
PROVISION OF STANDBY TROLLEY MOUNTED TRANSFORMER 11/.433 KV OF CAPACITY 315 KVA FOR MILITARY STATION GANDHINAGAR UNDER GE(ARMY) GANDHINAGAR.
2019_MES_303638_2
86798
Open Tender
Civil Works - Others
Item Rate
120 days
ARMY AREA GANDHINAGAR
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹28,600
Yes
25 Feb 2020
10 Jan 2020
18 Jan 2020
10 Jan 2020
17 Jan 2020
10 Jan 2020
10 Jan 2020 - 10 Jan 2020
Amount
Supply, install, test and commissioning copper wound step down transformer outdoor type complete with standard fitting ,HT 11 KV 3 Phase ,LT 433 Volt 3 Phase 4 wire with off load tapping on primary side to vary secondary voltage + 7.5 % with tapings at every 2.5 % rating of 315 KVA capacity (Energy efficent level- 2) The transformer shall be complete with all standard fitting and accessories gauges first fill of transformer oil upto appropriate level etc, all as per IS 1180 PART -I (2014) all jointing materials connected with elect system earthing etc complete incl platform as per manufacturer design all as specified and directed. comprising following ccessories : (a) One cable box HV side consisting of 3 nos porcelain terminal points incl nuts and washer with two nos cable gland suitable for up to 3 core 120 sqmm HT UG cable .
(b ) Suitable cable box LV side for mounting two LV cable consisting of 4 Nos porcelain with brass bushing rods , complete with nuts and washer with two nos cable gland suitable for LT UG cable providing with bimettalic lugs . ( c ) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with fast fill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover incl thermometer. (g) Rating plate and terminal marking plate. (h) The earthing terminal two nos to tank to faciliate fixing to earth strip. (i) Oil level gauge. (j) Lifting lugs (k) Oil filling hole with cap / plug with connection plate complete. (l) Air relief valve plug. (m) heavy duty MS mounted trolley type structure having required leaf spring, as specified by OEM complete with all MS Structure and pulling MS rod cum hook, 04 Nos tyre wheel dunlop/ MRF size 7.00 x 16, 8 ply rating,1 No spare wheel. The trolley will be suitable for carrying of 315 KVA transformer and a provision of jacks for lifting/ Pullup of wheel. Cost of trolly, jacks and connected items shall be deemed in qouted rate. complete all as specified and directed.
M & L, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 volts grade cross Sectional area 95 sqmm 3 core including complete connection with trolley mounted transformer on HT side all as specified and directed.
M & L, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross section of area 240 sqmm 3.5 core complete including all connection with suitable aluminium thrimble all as specified and directed.
M & L for cable jointing kit of 11KV (earthed) grade cable fro outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
One cable box LV side consisting of 4 Nos porcelain with brass bushing rods, complete with nuts and washers with two nos. cable gland suitable for 3.5 core 300 sqmm LT U/G cable.
Oil conservator with filter type drain valve and oil level indicator.
Dehydrating breather with fast fill of dehydrating agent.
Explosion vents.
Thermometer pocket on tank cover including thermometer.
Rating plate and terminal marking plate.
The earthing terminal two nos. to tank to faciliate fixing of earth strip.
Oil level gauge.
Lifting plugs.
Oil lifting hole with cap/plug with connection plate complete.
Air relief valve plug.
Initial filling of transformer oil of dielectric strength not less than 60 KV.
Two nos. GI tubing, light grade, 80 mm dia, 2 m long embedded in wall on HT & LT side for drawing LT/HT underground cable. Make : Asian/Prakash Surya/Jindal
Tap Changer
Make of transformer :Voltmap/Rajasthan Transformer Switch Gear/Gujrat Transformers/.
Fill up of New Transformer Oil (Initial Oil filling) all inclusive rate quoted by contractor.
ALBA AC AND REF SERVICES
SATISH ELECTRICALS
S S Infrazone
Electromech Engineers
Sai Ram Electricals and Refrigeration Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .