Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC MOORKOTH HOUSE PO MUZHAPPILANGAD KANNUR 670 662 | KANNUR | KERALA | 670662 | L1 | Accepted-AOC Lower amount quoted. | |
| 2 | L2₹28.5 L+₹4.3 L (17.8%)Rejected-AOC 214 2ND FLOOR SAMRUDDHI COMMERCIAL PREMISES CHINCHOLI BUNDER ROAD MINDSPACE MALAD WEST | L2 | Rejected-AOC Higher amount quoted. | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically disqualified. |
Tender Value
₹25.7 L
EMD Value
₹51,308
Closing Date
4 Aug 2020, 3:00 pmClosed
AC and RD
RO, ESIC, Thrissur
Annual Repairs and Maintenance to ESI Hospital and Staff Quarters at Thottada, Kannur and ESIC Branch Office and ESI Dispensary at Pappinissery, Kannur during 2020-21
2020_ESIC_558341_2
04/ARM/20-21/RO-Kerl/ESIH-Ttda
Open Tender
Civil Works
Item Rate
365 days
Thottada
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹51,308
Yes
16 Oct 2020
11 Jul 2020
5 Aug 2020
11 Jul 2020
4 Aug 2020
11 Jul 2020
Amount
Engaging skilled Plumber cum supervisor (Male only) with necessary tools and miscellaneous minor fittings such as Telxon tape, washers, jumper valves etc for attending the day to day complaints, minor repair works, fixing/replacing the damaged fittings such as taps/wash basins, EWC/IWC, flushing cisterns, Replacing damaged PVC/GI pipe lines, PVC rain water pipes and fittings, pumping water to the Hospital buildings and staff quarters including cleaning service tanks, minor repairing and maintenance of Pumps and periodic chlorination of open wells etc all works connected with internal/ external water supply lines, water supply fittings/ fixtures, sanitary installations, under ground sumps/ OHT, Plumbing works connected with STP etc at ESI Hospital & Staff Quarters at Thottada, Kannur and ESIC Branch Office & ESI Dispensary at Pappinissery, Kannur as directed by the Engineer in charge excluding Sundays and holidays.
From 9 AM to 5 PM in one shift.
Engaging sewer man for attending complaints on sewer/drainage lines, removing blockage in Drainage/ sewer lines, Gully traps, Manholes and Septic tanks etc. in ESI Hospital & Staff Quarters at Thottada, Kannur and ESIC Branch Office & ESI Dispensary at Pappinissery, Kannur and other works entrusted to Beldars when works assigned as sewer man are free and as directed by the Engineer in charge.
One sewer man in one shift from 9 AM to 5 PM on daily call basis excluding sundays and as per requirement complete as directed by the Engineer in charge.
One sewer man in one shift from 9 AM to 5 PM on all days excluding Sundays or any off day per week in lieu of working on Sunday in exigence of work.
Engaging Beldar (Male Mazdoor) for assisting plumber in attending the day to day complaints of all sorts of Internal water supply/External water supply/sanitary installations, Assisting carpenter in repair works, cleaning open area in campus, Assisting sewer man in clearing blockages/ clearing silting storm water drains including removing and replacing RCC covers, removing growth of baniyan tree on buildings, cleaning Terrace water tanks, Over head tanks, underground sumps and cutting/Pruning branches of trees up to 20 cm in diameter etc at ESI Hospital & Staff Quarters at Thottada, Kannur and ESIC Branch Office & ESI Dispensary at Pappinissery, Kannur (Beldar is not to be specifically attached with any skilled worker and suppose to attend all woks assigned to him and as directed by the Engineer in charge).
Beldar 1 (male mazdoor) in one shift of eight hours between any time from 9 AM to 5 PM on all days excluding Sundays or any one-off day per week in lieu of working on Sunday in exigence of work.
Beldar 2 (male mazdoor) in one shift of eight hours between any time from 9 AM to 5 PM on all days excluding Sundays or any one-off day per week in lieu of working on Sunday in exigence of work.
Engaging Skilled Carpenter/Mason/ Aluminium Fabricator/welder/other similar trades men with necessary tools and miscellaneous fittings such as screws ,nails, awl plugs, wooden gutties etc and sleeves etc in attending complaints regarding all steel/wooden/Aluminium doors, windows /partitions in the ESI Hospital & Staff Quarters at Thottada, Kannur and ESIC Branch Office & ESI Dispensary at Pappinissery, Kannur as directed by the Engineer in charge.
In one shift from 9 AM to 5 PM on daily basis as and when required by the Engineer in charge.
Cleaning of septic tank of size up to 5 x2x 2 m including removing and refixing the cover slab , fully de sludging and emptying the tank either manually or by truck mounted sucking units including disposing the sludge either to the Municipal dumping yard or locally by making earth pits and refilling with earth etc complete as directed by the Engineer inn charge. (A photograph of cleaned septic tank bottom shall be provided along with the bill for payment).
Providing electric welding with portable welding machines including welding rod cost for minor welding repair etc complete as directed by the Engineer in charge.
Clearing jungle Mechanically with JCB or similar machinery including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level including dressing the surface /filling the undulation etc and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (Cutting shall be done on prior approval and necessary certificate after finishing the cutting work each time shall be obtained from the concerned ESI Office.)
Cutting branches of trees of the girth (measured 1 m from stem), including cutting of trunks and branches, and stacking of serviceable material and disposal of unserviceable material.
Beyond 60 cm girth up to and including 120 cm girth.
15 mm cement plaster on terrace finished with a floating coat of neat cement of mix 1:3(1 cement: 3 fine sand) including making false markings of 30 cm x 30 cm with nylon thread of 6 mm dia.
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
For horizontal surface one coat @1.10 kg per sqm.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.
25mm average thickness.
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
Bars upto 12 mm diameter metre.
Bars above 12 mm diameter metre.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer.
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
Plaster thickness varying between 12 to 25 mm.
Supplying only following miscellaneous fittings/materials for plumber/Carpenter/mason of approved quality.
Oxidized Mild steel butt hinges 125*65*2.12 mm
Oxidized Mild steel butt hinges 75*47*1.70 mm
Anodised Aluminium handles 125 mm (ISI)
Anodised Aluminium handles 100 mm (ISI)
Anodised Aluminium handles 75 mm (ISI)
Anodised Aluminium sliding door bolt 300x16mm (ISI)
Anodised Aluminium Tower Bolts (ISI) 200*10 mm
Anodised Aluminium Tower Bolts (ISI) 150*10 mm
Anodised Aluminium Tower Bolts (ISI) 100*10 mm
Brass bib cock 15 mm (400 gm)
Brass stop cock 15 mm (400 gm)
CI gratings 150*150 mm
SCI gully/Nahni grating 100 mm
White vitreous EWC Pan of approved make
White vitreous china Wash Basin 630*450 mm
White vitreous WC, Orissa Pan of approved make
Brass full way wheel valve with CI wheel 25 mm
Brass full way wheel valve with CI wheel 40 mm
Brass full way wheel valve with CI wheel 50 mm
Brass full way wheel valve with CI wheel 80 mm
Gun Metal Non return Valve 40 mm
Gun Metal Non return Valve 50 mm
Gun Metal Non return Valve 80 mm
CP brass waste coupling 32 mm
CP brass waste coupling 40 mm
Plain float glass panes 4 mm thick (weighing 10 kg/sqm)
Brass cup board locks 6 levers 65 mm
UPVC pipe 4 kg/sqcm 110 mm dia
UPVC pipe 4 kg/sqcm 75 mm dia
UPVC bend 87.50-degree 110 mm
UPVC bend 87.50-degree 75 mm
CP brass Bib cock 15 mm (400 gm)
CP brass long body Bib cock 15 mm (690 gm)
CP Brass Angle valve 15 mm (400 gm)
CP Brass stop cock concealed
PVC flushing cistern 10 litres capacity
CP Brass with elbow operation lever bib cock 15 mm
PTMT Bib cock 15 mm
PTMT stop cock 15 mm
PTMT pillar cock 15 mm
CPVC pipe 15 mm dia
CPVC pipe 20 mm dia
CPVC pipe 25 mm dia
CPVC pipe 40 mm dia
CPVC pipe 50 mm dia
CPVC pipe 75mm dia
White plastic seat with lid / brass hinges for EWC
Polyethylene water storage tank with cover and suitable locking arrangement Sintex /Aqua ISI marked
Silicone Sealant
GI hook and eye 75mm
PVC tank cover
PVC connection with brass union 45cm long
HP or LP brass ball valve with polythene float 25mm dia
CP brass Pillar tap for wash basins weighing not less than 650 gm
CP brass health faucet 15mm
PVC handle with lever for flushing cistern
Siphoning set with rubber washer
Flexible PVC waste 32mm
Flexible PVC waste 40mm
CPVC elbow 25mm
CPVC bend 25mm
CPVC threaded adapter 25mm
CPVC threaded adapter 32mm
CPVC tee 25mm
CP hex nipple 15mm
CPVC clip
110mm PVC coupler
110mm PVC clip
PVC end cap 15 mm to 40 mm
110 mm dia door Tee PVC
110mm dia door elbow PVC
110mm bend PVC
PVC bend 15 mm
PVC bend 20 mm
PVC bend 25 mm
PVC bend 40 mm
PVC bend 50 mm
PVC elbow 15 mm
PVC elbow 20 mm
PVC elbow 25 mm
50mm door elbow PVC
CPVC coupler 25mm
CPVC coupler 32mm
kitchen sink Stainless steel with drain board 510x1040mm with 225mm bowl depth
GI sheet .80mm thick
APP modified plastic felt 1.50mm thick for small patches
GI wire mesh .63mm
Ply wood 6mm thick 5 layer, BWR
Bitumen primer for APP membrane
Tarpoline Plastic, thickness not less than 600 micron size not less than 20'x20'
Float glass panes 5 mm thick (12.50 kg/sqm) cut to size including wastage
Anjali/Jakwood in scantlings (excluding wastage to be measured)
Hydraulic door closer Tubular type Aluminium section body
100 mm mortice n lock 6 levers for Aluminium doors
Aluminium Grill as per IS 1868 (excluding wastage to be measured)
Prelaminated Particle Board both side decorative lamination Exterior grade 12 mm (excluding wastage to be measured)
Dash fastener/Chemical fastener for aluminium work
Powder Coated Aluminium sections (used at site excluding wastage)
Double action hydraulic door floor spring with stainless steel cover plate
Galvanised steel plain sheet used at site excluding wastage)
Second class moulded beading 50 x12 mm (Finished beading used excluding wastage)
Second class moulded beading 50 x20 mm (Finished beading used excluding wastage)
Aluminium hanging floor door stopper with twin rubber & stopper
Credit for dismantled materials (payment to be made to ESIC in lieu of dismantled materials available while replacing with new fittings).
CP Brass bib cock 15 mm
CP brass stop cock 15 mm
CP brass angle valve 15 mm
Gun metal valve- 20 mm nominal bore
Gun metal valve- 25 mm nominal bore
Gun metal valve- 32 mm nominal bore.
Gun metal valve- 40 mm nominal bore
Gun metal valve- 50 mm nominal bore
Gun metal valve- 80 mm nominal bore
15 mm nominal outer dia GI pipe
20 mm nominal outer dia GI pipe
25 mm nominal outer dia GI pipe
32 mm nominal outer dia GI pipe
40 mm nominal outer dia GI pipe
PVC Connections 15x300 mm
CP Brass pillar taps 15 mm
Fire Wood
ORIENTAL INTEGRATED FACILITY MANAGEMENT PVT. LTD.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .