| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.5 L+₹76,540 (2.20%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹37.7 L+₹3.0 L (8.49%)Rejected-Finance BLDG NO 11 88 LAKSHMI BUILDERS UPPADA POST NILAMBUR MALAPURAM KERALA 679334 | MALAPPURAM | KERALA | 679334 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹39.3 L+₹4.6 L (13.1%)Rejected-Finance RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹40.0 L+₹5.2 L (15.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹40.0 L
EMD Value
₹79,980
Closing Date
23 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2024_MES_648145_1
GE MAINT EZHIMALA 8635
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹79,980
Yes
20 May 2024
28 Mar 2024
25 Apr 2024
28 Mar 2024
23 Apr 2024
11 Apr 2024
29 Mar 2024 - 5 Apr 2024
Amount
Notes for all items of BOQ:- 1. The contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safety measures are to be adopted by contractor on site. 3. The contractor shall provide and deploy sufficient electrician ( as approved by GE/ Engineer in charge) shall report at 9.00 hrs to JE E/M / Engineer in charge to collect the complaints job card in working days and complete the same complaint within 24 Hrs. 4. The complaints shall be rectified within 24 hrs if the complaints is/are not attended / not completed with in 24 hrs ( except repair/ replacement of major items) recovery will be done at Rs. 500 per complaint per day. 5. For major parts like replacement of MCB, DBs, MCCBs etc should be rectified within 3 working days, if the contractor not rectify within time then recovery will be done at Rs.1000 per complaint per day. 6. After completion of job work complaint, the contractor has to produce job card duly signed by user & JE /Engineer in charge. 7. If contractor failed to provide their electrician to attend the complaints then recovery will be done at Rs. 1000 per day. 8. The Contractor should procure minimum 50% of the materials for all items as per BOQ (other than paints) mentioned in this CA within 20 days after getting sample approval and kept in safe custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of work. If contractor fail to complete the work within contract due to lack of fittings, a penalty of 20% shall be applicable on quoted rates by the contractor. 9. In repair works, rate quoted for demolition/dismantling/taking down is deemed to be inclusive of removing the same from site and dumped outside INA Ezhimala. 10. In maintenance works, the contractor should maintain separate registers for plumbing and carpenter repair works. Day to day complaints should be noted in those registers with Sl nos of complaints, location, qty of work, status of complaints and signature of in charge and stamp of the office. Format will be given from concern AGE office. The contractor should obtain the signature of in charge on the same day of work. These registers to be submitted to JE(Civil) on every weekend without fail. 11. The contracts involving working at elevated locations of buildings, contractor should ensure proper safety arrangements as per norms. Wearing safety belts and helmets are mandatory. A penalty of Rs 1000 per day will be recovered from contractor if safety norms are not followed. 12. The plumbing complaints resulting wastage of water should be rectified within 12 working hours and if contractor fail to fullfill this, a recovery of 10% of rate quoted for relevant item will be charged from contractor in this regard. 13. After completion of work, no stores/debris/loose items be kept at work site or dumped inside INA. Entire area to be cleared and waste material be taken outside INA.
M&L for preparation of old treated surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
M&L for preparation of old treated ceiling surfaces and applying one coat of oil emulsion distemper complete all as specified and as directed.
M&L for preparation of old treated surfaces and applying one coat of acrylic emulsion paint on wall (interior grade) using suitable mechanical sprayer all as specified and as per manufacturer's instructions.
M&L for preparation of old treated surfaces and applying two coats of acrylic emulsion paint on wall (interior grade) using suitable mechanical sprayer all as specified and as per manufacturer's instructions.
M&L for preparation of wall surfaces by scrubbing using nylon/jute/ wire brushes/ scrapper blades and applying wall care putty interior or exterior and finishing the surface even and smooth complete all as specified and as directed.
M&L for preparation of old painted surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces complete all as specified and as directed.
M&L for preparation of old painted surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint on steel/iron surfaces complete all as specified and as directed.
M&L for preparation of old painted surfaces n.exc 10cm width or girth and applying one coat of synthetic enamel paint on steel/iron surfaces complete all as specified and as directed.
M&L for preparation of old painted surfaces and applying one coat of epoxy paint to steel surfaces complete all as specified and as directed.
S&F in repair vitreous china wash basin,coloured (flat back) 550x 400mm excluding pillar tap, but including fixing brackets, cutting for and pinning in ends of brackets complete all as specified and as directed.
S&F in repairs pillar taps 15 mm size, cast copper alloy, chromium plated screwed down high pressure screwed for iron pipe & fixed complete all as specified and as directed.
S&F in repair vitreous china, wash down water closet (EWC) with seat cover coloured, closed pattern with flat bottom and cover with mild steel (CP) or aluminium hinging device fixed with necessary bolts complete all as specified and as directed.
S&F plastic seat cover (colour) closed pattern with flat bottom suitable for EWC including taking down old cover complete all as specified and as directed.
S&F in repair 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve, float and handle including brackets complete all as specified and as directed.
S&F in repair 15mm bore chromium plated bib taps long body fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes including taking down of old items complete all as specified and as directed.
S&F in repair angular stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for union and fixed, suitable for 15 mm bore pipe complete all as specified and as directed.
S&F in repair brass chromium plated towel ring complete all as specified and as directed.
S&F in repair 20mm dia, D type, 60cm long cast copper alloy, chromium plated towel rail complete all as specified and as directed.
S&F in repair chromium plated soap tray fixed with CP brass screws complete all as specified and as directed.
S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and as directed.
S&F in repair cast copper alloy, chromium plated waste coupling with long shank, half thread, 32 mm dia for WHB etc. complete all as specified and as directed.
S&F in repairs 32mm dia PVC flexible waste pipe for urinals/WHB/ sink complete all as specified and as directed.
S&F in repair 75mm PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding, removing serviceable tiles to store and rubbish of the premises complete all as specified and as directed.
M&L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.06 sqm but n.exc 0.11 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 20mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles 350x250x7mm / 450x350x7 mm thick in vertical surfaces of stone/brick wall, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick backing coat plaster in CM 1:4 complete all as specified and as directed.
Cleaning and removing all scales and dirts etc from tanks and from mouths of circulating pipes etc. of capacity exc 250 and n.exc 500 ltrs complete all as specified and as directed.
Taking down defective/damaged water storage tank cover and supply & fix polyethylene tank cover with necessary locking arrangement complete all as specified and as directed.
Dismantling the existing water tank and S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 litres complete all as specified and as directed.
S&F in repair ball brass valves, high pressure, with polythene float and flynut (25mm) complete, screwed for iron pipe or brass ferrule and fixed in repairs complete all as specified and as directed.
S&F in repair brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
S&F in repairs curtain rails, anodised aluminium alloy with fixing brackets, stops, rollers etc complete all as specified and as directed.
S&F in repair plastic finial of 28 to 29mm bore decorated type of any colour/pattern best quality to suit the curtain rod and fixed at the end of curtain rod with suitable adhesive complete all as specified and directed by Engineer-in-Charge. Make:- Aerolux/MEC/VISTA.
S&F in repair mild steel prepainting bracket to hold the curtain rod and fixed to wall (concrete /brick masonry) with the help of 2 Nos 50mm long steel screws and rawl plug including drilling with electric drill and making good the distrubed surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm but n.exc 4.00 Sqm each complete all as specified and as directed.
S&F pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, etc complete all as specified and as directed.
M&L for filling concrete inside frame in PCC 1:3:6, type C-0 complete all as specified and as directed.
S&F 30 mm thick 1st class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats including iron mongeries and builders hardwares complete all as specified and as directed.
Taking down chowkats with shutter (without taking off shutter from the frame) n. exc 1.5 Sqm each complete all as specified and as directed.
S&F solid PVC double door frame of size 50mm x 95mm made out of 5mm plain colour PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per manufacturer's specification & drawing complete all as specified and as directed.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (styles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per manufacturer's specification & drawing with particle board core including iron mongeries and builders hardwares complete all as specified and as directed.
S&F in repair 100mm long aluminium, anodised barrel tower bolt of extruded section complete all as specified and as directed.
S&F in repair 150mm long aluminium, anodised barrel tower bolt of extruded section complete all as specified and as directed.
S&F 100mm mild steel butt hinges, cold rolled medium weight complete all as specified and as directed.
S&F 100mm extruded anodised aluminium alloy handles fabricated type complete all as specified and as directed.
S&F 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F in repairs 75mm mild steel butt hinges, cold rolled medium weight complete all as specified and as directed.
S&F in repairs 100mm extruded anodised aluminium alloy handles fabricated type complete all as specified and as directed.
S&F in repairs mortice lock brass body, 100 mm, 4 levers vertical type complete all as specified and as directed.
S&F in repairs 75 mm hasp and staple mild steel safety type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and as directed.
S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and overall length of cover plate 140mm complete all as specified and as directed.
S&F in repair aluminum alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum wire staples complete all as specified and as directed.
S&F in repair 125mm size brass chromium plated shower rose complete all as specified and as directed.
M&L for hacking out old broken glass ( any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/ spring clips and providing and fixing new ones complete all as specified and as directed.
M&L for 4mm thick sheet glass plain ordinary quality not exc 0.50 sqm in each pane and glazing with beading complete all as specified and as directed.
M&L for 5.5mm thick sheet glass plain ordinary quality exc 0.50 sqm in each pane and glazing with oil putty complete all as specified and as directed.
Removal of air lock in internal water supply system of pipe of any dia complete all as specified and as directed.
S&F in repairs rubber beading suitable size for safety purpose (snake guard) in bottom of door complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan and power socket etc) complete (except concealed conduit) including fittings such as switches, ceiling roses, pendent, regulators, sockets, earth plug and socket etc and making good matching to the existing colour to the disturbed surface complete all as specified and as directed.
M&L for color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC casing capping with suitable size GI flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting 6 Amps switch with socket on independent board including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and as directed for the following:- Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral and earth conductor. (iii) The wiring shall be done strictly by following proper colour coding using red , blue, yellow for phase, black for neutral and green for earth leads. (iv) Size of copper earth wire must be equal to size of current carrying conductor upto size 16 sqmm.
(a) One Light/ fan point controlled by one switch
(b) One 3 pin socket outlet 5 Amps on the same board with other switches
(c) 5 Amps socket point on independent board
All as per item No.63 here in above but 2.5 sqmm for 15 Amps socket on independent board complete all as specified and as directed.
All as per item No.63 here in above but 4 sqmm for 16/20 Amps socket on independent board complete all as specified and as directed.
All as per item No.63 here in above for one bell/buzzer point controlled by one push button on the same board with other switch or independent with cable 1.5 sqmm size in PVC conduit complete all as specified and as directed.
M&L for sub main wiring color coded using 2 runs of 2.5 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through PVC casing capping along with 1 run of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring using 2 runs of 4 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing capping along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring using 2 runs of 6 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing caping along with 1 run of 6 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring using 4 runs of 10 sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing caping along with 2 runs of 10 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge. Note for item No.67 to 70 :- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) For single phase three runs of cable, three phase six run of cable and one run of conduit /casing & capping with necessary accessories will be measured as one unit length. (iii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
M&L for sub main wiring color coded using 2 runs of 2.5sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through existing conduit along with 1 run of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring using 2 runs of 4 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including existing conduit along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring using 2 runs of 6 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including existing conduit along with 1 run of 6 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge. Note for item No.71 to 73 :- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Three runs of cable with necessary accessories will be measured as one unit length. (iii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
S&F switch piano, flush mounting type, single pole, one AC 230V grade 5Amps ISI marked complete all as specified and directed by Engineer-in-Charge.
All as per item No.74 here in above but 15 Amp ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F modular bell push 6 Amps 1 module complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 5 amp multi pin type ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 3 pin 15 amp multi pin type ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F fan regulator electronic step up type type 100/120 Watt AC 230 watts complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose 3 pole 240V PVC/Poly carbonate insulated body ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in repair switch piano, flush mounting type single pole one way 230V grade 5 Amps complete all as specified and directed by Engr in charge.
All as per item No.81 here in above but 15 Amp complete all as specified and directed by Engr in charge.
S&F in repair socket outlet 3 pin 5 A complete all as specified and directed by Engr in charge.
S&F in repair socket out et 3 pin 15 Amp complete all as specified and directed by Engr in charge.
S&F in repair call bell ding dong AC 230 volts complete all as specified and directed by Engineer-in-Charge.
S&F in repair modular switch one way 6 Amps 1 module ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in repair modular socket 6 Amps 2 module multi pin ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in repair modular switch one way 16 Amps 1 module ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in repair modular socket 16 Amps 2 module ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in repair white cover plate 2/3/4 module including taking down the defective one complete all as specified and directed by Engineer-in-Charge.
S&F in repair switch socket combination 5/16 Amps 5 in one flush type ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB single pole AC 240 Volts, 6 to32 Amps C-Series complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB single pole & neutral, AC 240 Volts, 32 Amps C-Series complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB triple pole & neutral, 40 Amps, 415 Volts AC, C-Series complete all as specified and directed by Engineer-in-Charge.
S&F in repair RCBO's for earth leakage protection double pole 300mA, 40 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repair modular AC socket with MCB single pole 25/32Amps, C-Series, AC 240 Volts complete all as specified and directed by Engineer-in-Charge.
S&F in repair lamp holder, PVC type suitable for pendent/batten fittings complete all as specified and directed by Engineer-in-Charge.
S&F in repair condenser 4 mfd, AC 440 Volts suitable for exhaust fan complete all as specified and directed by Engineer-in-Charge.
S&F in repair condenser 2.5mfd, AC 440 Volts suitable for ceiling fan/exhaust fan complete all as specified and directed by Engineer-in-Charge.
S&F in repair fan regulator (Modular) electronic step up type 100/120 Watt AC 230 Volts complete all as specified and directed by Engineer-in-Charge.
S&F in repair hylam sheet 3 mm thick suitable for switch boards etc complete all as specified and directed by Engineer-in-Charge.
S&F LED lamp 10 Watt B 22 suitable for batten/pendent holder complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB DB SPN 240V double door outdoor type, 12 way with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB DB TPN 415V double door type, 6 way with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail complete complete all as specified and directed by Engineer-in-Charge.
S&F in replacement surface and wall mounted 10 W 2 feet LED batten, output lumen greater than 100 lumen/watts, extruded channel in thermally conductive material for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver, making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in -charge. Make:- Crompton Model TRIMLINE-LDL-10W-CDL or equivalent in Philips/Wipro/ Havells.
S&F in replacement wall mounted 20 W 4 ft LED batten, output lumen greater than 100 lumens/watt, extruded channel in thermally conductive material for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton Model TRIM LINE NEU. CCS-103-20-65-SL-DP-NWH or equivalent in Philips/Wipro/ Havells.
S&F in repair LED down lighter fitting 18W, output lumen greater than 100 lumen/ watts with round shaped surface mounted, PDC aluminium housing and high translucent frosted plastic diffuser makes it a robust luminaire efficacy 100lm/w with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton Model PEARL NIOS-R-LCDSPLN-R-18-CDL or equivalent in Philips/Wipro/Havells.
S&F in repair LED bulk head fitting 10W output lumen greater than 100 watts with oval shaped surface mounted LED, PMMA diffuser, powder coated white finish housing with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton Model STUD- LBHP-10-CDL or equivalent in Philips/Wipro/ Havells.
S&F in repair surface mounted 18W luminaire 1x1 tile, output lumen greater than 100 lumen/watts, glare free uniform illumination housing with opel diffuser with colour temp 6000K with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton Model PEARL NIOIII- S-LCTLSNE-18-FO-CDL or equivalent in Philips/Wipro/Havells.
S&F in repair recess mounted 36W luminaire 2x2 tile, output lumen greater than 100 lumen/watts, glare free uniform illumination housing with opel diffuser with colour temp 6000K with driver making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Crompton Model Polaris NIO I LCTLRNE-36-FO-CDL or equivalent in Wipro/Philips/Havells.
S&F in replacement suspended LED luminaire output lumens greater than 100 lumens/watt provides soft light and glare free 20W LED, making connection to existing ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed by Engineer-in charge. Make:- Havells Model CONSTA LED CONSTA544LP20W857 or equivalent in Crompton/Philips/Wipro.
S&F PVC blanker for filling DBs unfilled gap available after fixing MCBs complete all as specified and directed by Engineer-in charge.
RS ENTERPRISES
lancor builders
SANDR
KARATHAT ITTYATHI GOPALAN
ROTECH ENGINEERS AND BUILDERS
KDR CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .