Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹82,362.80Accepted-AOC KACHEETTI PUTHEN VEEDU PALIYODE KUNNATHUKAL ANAVOOR P O TRIVANDRUM 695124 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695124 | ₹82,362.80 | 1 | Accepted-AOC L1 |
| 2 | 2₹87,044.27+₹4,681.47 (5.68%)Accepted-AOC | ₹87,044.27+₹4,681.47 (5.68%) | 2 | Accepted-AOC L2 |
| 3 | 3₹1.0 L+₹19,904.29 (24.2%)Accepted-AOC | ₹1.0 L+₹19,904.29 (24.2%) | 3 | Accepted-AOC L3 |
| Sl No | Description | Qty | Unit | MOHANAKUMAR V L1 | ARUN S L3 | GIREESH KUMAR S L2 |
|---|---|---|---|---|---|---|
| 1.00App.A - Working charges | ||||||
| 1.00 | 15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) | 1 | cum | 900 ₹900 Lowest | 1,254.52 ₹1,254.52 | 1,191.73 ₹1,191.73 |
| 1.00 | 15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road | 3.1 | sqm | 320 ₹992 Lowest | 1,264 ₹3,918.4 | 340.02 ₹1,054.06 |
| 1.00 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | 32.1 | cum | 540 ₹17,334 | 545.96 ₹17,525.32 | 519.95 ₹16,690.4 Lowest |
| 1.00 | 100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete. | 18.65 | Kwh | 32 ₹596.8 | 26.81 ₹500.01 Lowest | 30.17 ₹562.67 |
| 1.00 | 100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals. | 70 | metre | 18 ₹1,260 | 14.29 ₹1,000.3 Lowest | 24.56 ₹1,719.2 |
| 1.01 | 100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes. | 107 | metre | 70 ₹7,490 Lowest | 84.24 ₹9,013.68 | 79.97 ₹8,556.79 |
| 1.01 | OD21766/2025-2026:Taking interconnection (Double boring) from the existing CI main of size 200mm dia. to the newly laid 63mm uPVC pipeline, including supplying and fitting suitable size MS saddle pieces, boring the main, supplying and fitting 25mm brass ferrule-2nos, 25mm GM full way wheel valve-2no2, bend/elbow- 4nos,reducer- 2nos., adaptors incl. all required specials etc. and connecting the newly laid main, testing the joints etc.complete as per direction. | 1 | each | 6,000 ₹6,000 Lowest | 7,072.87 ₹7,072.87 | 6,353.39 ₹6,353.39 |
| 1.01 | 18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore | 1 | each | 950 ₹950 | 2,765 ₹2,765 | 844.35 ₹844.35 Lowest |
| 1.01 | 100.59.2:Refilling the trenches with a wet mix of close graded granular materials (Stone aggregate - 25mm nominal size - 17.5%, Stone aggregate - 10mm nominal size - 17.5%, Crushed Stone - 2.36mm to 12.5mm - 25%, Stone chippings / screenings - 4.75mm nominal size - 20%, Stone chippings / screenings - 150 micron nominal size - 20%), mixing properly after adding sufficient quantity of water, refilling in layers not exceeding 150mm, compacting properly at Optimum Moisture Content with Surface Plate Vibrator and disposing the excavated material etc. complete, including traffic control, providing caution boards and as per direction of Engineer-in-charge for road restoration works in pipeline leak sites. | 0.62 | cum | 4,000 ₹2,480 Lowest | 6,211.7 ₹3,851.25 | 6,741.68 ₹4,179.84 |
Tender Value
₹1.2 L
EMD Value
₹2,901
Closing Date
29 Jul 2025, 3:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer
DEPOSIT Work Pipeline extension and providing water connection to beneficiary under UPI Extreme Poverty Scheme of Thiruvananthapuram Municipal Corporation Providing house connection and associated pipeline extension to beneficiary under extreme pov
2025_KWA_778140_1
WRD/KWA/CE(SR)/1147/2025
Open Tender
Civil Works - Water Works
Item Rate
10 days
WW North Subdivision Kowdiar
Please refer Tender documents.
3 documents required · 3 mandatory
₹555
Yes
₹2,901
Yes
18 Aug 2025
21 Jul 2025
30 Jul 2025
21 Jul 2025
29 Jul 2025
21 Jul 2025
Amount
App.A - Working charges
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
OD21766/2025-2026:Taking interconnection (Double boring) from the existing CI main of size 200mm dia. to the newly laid 63mm uPVC pipeline, including supplying and fitting suitable size MS saddle pieces, boring the main, supplying and fitting 25mm brass ferrule-2nos, 25mm GM full way wheel valve-2no2, bend/elbow- 4nos,reducer- 2nos., adaptors incl. all required specials etc. and connecting the newly laid main, testing the joints etc.complete as per direction.
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
100.59.2:Refilling the trenches with a wet mix of close graded granular materials (Stone aggregate - 25mm nominal size - 17.5%, Stone aggregate - 10mm nominal size - 17.5%, Crushed Stone - 2.36mm to 12.5mm - 25%, Stone chippings / screenings - 4.75mm nominal size - 20%, Stone chippings / screenings - 150 micron nominal size - 20%), mixing properly after adding sufficient quantity of water, refilling in layers not exceeding 150mm, compacting properly at Optimum Moisture Content with Surface Plate Vibrator and disposing the excavated material etc. complete, including traffic control, providing caution boards and as per direction of Engineer-in-charge for road restoration works in pipeline leak sites.
100.59.3:Restoring the road surfaces by providing and laying factory made cold bitumen-aggregate pot-hole repair mix in two layers of 25mm thick (total 50mm thick), by cleaning the surface with brooms etc. to remove dust/debris/water etc, placing the premix, compacting properly with hand-rammer etc. complete, including traffic control, providing caution boards and as per direction of Engineer-in-charge for road restoration works in pipeline leak sites.
100.60.1.3.2:Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.3.1.1:Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers
App.B - Supply of materials
OD24436/2025-2026:63mm PVC 10kg/cm2 elbow
OD24437/2025-2026:Supplying and fixing 63mm PVC (10Kg/cm2) endcap
OD24438/2025-2026:Supply of 63mm PVC Bend, 10 kg/cm2
OD24439/2025-2026:Supply of 63mm 10kg/cm2 PVC Tee
100.98.239:Supply of PVC Pipe, 10kg/cm2, 160mm Dia.
GIREESH KUMAR S (BID ID -2264433)
ARUN S (BID ID -2265040)
Bidder Name
MOHANAKUMAR V
ARUN S
GIREESH KUMAR S
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1273576.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .