Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹2.0 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹2.0 Cr+₹4.8 L (2.43%)Rejected-Finance 796 AZAD NAGAR ROORKEE DISTT HARIDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | ₹2.0 Cr+₹4.8 L (2.43%) | L2 | Rejected-Finance Being Not Lowest |
| 3 | L3₹2.2 Cr+₹19.8 L (9.98%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹2.2 Cr+₹19.8 L (9.98%) | L3 | Rejected-Finance Being Not Lowest |
| 4 | L4₹2.3 Cr+₹29.2 L (14.7%)Rejected-Finance | ₹2.3 Cr+₹29.2 L (14.7%) | L4 | Rejected-Finance Being Not Lowest |
| 5 | L5₹2.3 Cr+₹31.0 L (15.6%)Rejected-Finance | ₹2.3 Cr+₹31.0 L (15.6%) | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹2.5 Cr
EMD Value
₹3.2 L
Closing Date
15 Nov 2022, 6:00 pmClosed
CHIEF ENGINEER BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243 001
ADDN ALTN CUM SPECIAL REPAIR TO CERTAIN MD ACCN FOR OFFRs JCOs AND ORs AT RAIWALA
2022_MES_552675_1
CEBZ/DDN(H)/T-09 OF 2022-23
Open Tender
Civil Works
Item Rate
365 days
RAIWALA
AS PER NIT
8 documents required · 8 mandatory
₹2,000
AGE (I) RAIWALA
₹3.2 L
Yes
26 Dec 2022
17 Sept 2022
23 Nov 2022
17 Sept 2022
15 Nov 2022
31 Oct 2022
19 Sept 2022 - 28 Sept 2022
Amount
BUILDING WORKS
Demolition of existing roof treatment i.e APP membrane including screed bed, brick tiling, mud mortar/lime concrete and open up RCC roof slab and picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey.The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items .
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggreagte) mixed with liquid water proofing compound as per manufacturer's instructions over and including coat of cement slurry @ 1.2 Kg/Sqm mixed with SBR latex liquid polymer as per manufacturer direction as to be used for bonding of new concrete to old concrete surface and finishing the surface even and smooth without using extra cement as in roof padding and sunken floors, complete all as specified and directed. Note :- Water proofing compound and (SBR) Latex liquid polymer will be measured and paid seperately.
M & L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3 .6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance
Note for item No 2 to 4 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material and removing the demolished material outside the MOD land.Complete all as specified and directed
M & L for PCC 1:1.5:3 type A-0 (Using 12.5mm stone aggregate) as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed with polymer modified repair mortar complete all as specified and directed. (SBR Latex liquid polymer as per manufactur direction ) Note :- (SBR) Latex liquid polymer will be measured and paid seperately..
M&L for Providing and application two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge . Note : Ponding test after water proofing coating willl be done for ponding for 48 Hrs .
M & L for 15 mm thick protection plaster CM 1:4 floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur's instructions), complete all as specified and directed Note :- (SBR) Latex liquid polymer will be measured and paid seperately.
M & L for providing 40 mm dia GI pipe (medium grade) spout projecting at least 300 mm beyond outer face of wall complete all as specified and directed.
M & L for cement concrete 1:5:10 type E-2 (using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and directed.
M & L for 30 mm thick PCC Type B-0, 1:2:4, (using 12.5 mm graded stone aggregate) as in floor mixed with polymer modified repair mortar (SBR Latex liquid polymer @ 1.5 Litre per 50 Kg bag of cement.Complete all as specified and directed Note :- (SBR) Latex liquid polymer will be measured and paid seperately
Supply only SBR Latex liquid polymer of approved make complete all as specified and directed.
Supply only liquid water profing compound of approved make complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and removing all loose dirt particle from brick/concrete surfaces and application of cement slurry coat @ 1.2 Kg/Sqm mixed with SBR latex as per manufacturer's instruction by brush on brick/concrete surfaces and M&L for 15 mm thick plaster with cement mortar 1:4 mixed SBR latex liquid polymer as per manufacturer's instruction including finishing the surface even & smooth without using extra cement complete all as specified & directed. Note:- (i) SBR latex liquid polymer will be measured & paid separately under respective item. (ii) The work is required to be carried out for double storyed building the contractor shall make arrangement of adjustable telescopic scofolding wherever required and rates quoted shall deemed to be included for same.
Dismantling of (salt glazed ware, AC or reinforced concrete) drain pipes up to 100mm dia , jointed in cement mortar and taking out of trenches if required . complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
S & F 110 mm PVC (SWR) WC connector with lip ring complete all as specified and directed.
S & F PVC (SWR) reducers of size (110x75) mm complete all as specified and directed.
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and directed.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
S & F 110 mm bore PVC (SWR) P Trap complete all as specified and directed.
S & F 75 mm bore PVC (SWR) floor Trap, plain with grating inclding jointing with solvent cement complete all as specified and directed.
S & F in repair stack clamps made out of (40x3) mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to walls or roof for 100 mm pipe, complete all as specified and directed.
All as per Srl Item No 33 above but 75 mm bore pipe. complete all as specified and directed.
Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement cut as required to facilitate demolition upto and including on the roof top / mumty / parapet / RCC chajjas / RCC water tank and removal of debris and rubbish out side MoD land complete all as specified and directed.
M & L RCC 1:2:4 type B1 (using 20mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc. complete all as specified and directed.
M&L RCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) in Chajjas / fins / facia for minor repair including formwork including one coat of SBR latex as bonding of old concrete to new concrete Complete all as specified and directed. Note:- (i) (SBR) latex liquid polymer will be measured and paid seperately. (ii) The work is required to be carried out at for double storey . The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items .
Use and waste Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick, rough finished flat surface of concrete complete all as specified and directed.
M & L precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed.
M & L for mild steel TMT bars 6 mm to 8 mm dia, for minor repairs as in RCC chajja, fins, facia, kitchen slab, incl welding (where required), bending cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) including removal of rubbish out side complex (MOD land), complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 12 mm thick joint up to full thickness and filled with pre-formed bitiuminous filler, complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) in flooring / hard standing/foot path finishing surface even & fair complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sqm each complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each complete all as specified and directed.
Refixing of shutter of any description not exceeding 1.00 sqm each in other opening of any descrption after easing and adjusting , repairing , tightening the joints of frame of shutter. complete all as specified and directed
Refixing of shutter of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each in other opening of any descrption after easing and adjusting , repairing , tightening the joints of frame of shutter complete all as specified and directed
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each complete all as specified and directed.
S&F second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Supplying and fixing windows & ventilators fabricated from rolled formed GI Section made of Galvanised steel colour coated (PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanized as per IS 277 with Zinc of 120 Gsm/Sqm w. PAINT: Pre-Painted sections with primer coat of epoxy primer of 5-10 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and fly mesh shutter, 74 X 60mm outer frame , mullion 72 x 49mm, glazed shutter 48 x 22mm, flymesh 41 x22mm, beading with round ends for glass fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters, sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and stainless steel wiremesh of 36 guage to fix in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat, each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter. Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm square bar welded to 6 x 12mm MS flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expansion caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets, stay, hinges, mullion caps of windows, complete all as directed. Make- TATA/NCL/JSW
M&L 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density shall be as per manufacture instruction complete all as specified and complete all as specified and directed.
S & F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of 35 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F 100mm X 65mm Single Rebate Factory made 100 % Solid WPC door Frame made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cbm & Manufactured by an ISO: 9001-2015 certified company, all as per specification. The door frame should be Water Proof , Termite Proof , Fire Retardent and having excellent screw holding capacity, complete all as specified and directed
S&F 125mm X 65mm Double Rebate Factory made 100 % Solid WPC door Frame made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cbm & Manufactured by an ISO: 9001-2015 certified company, all as per specification. The door frame should be Water Proof , Termite Proof , Fire Retardent and having excellent screw holding capacity, complete all as specified and directed .
S&F 30mm Thick moulded WPC Factory made 100 % Solid door (Conforming As Per IS : 4020 ) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with Wood GrainTexture and back side palin with density not less than 600 kg/cum. Manufactured by an ISO:9001-2015 certified company. The door should be Water Proof , Termite Proof , Fire Retardent and having screw holding capacity, complete all as specified and directed.
M & L for plain fillets of second class hard wood (suitable for joiner’s and carpenter’s work, locally available) section area exceeding 13 Sq.cm and not exceeding 25 Sq.cm, square, rectangular or triangular in section, wrought secured with nails. complete all as specified and directed.
S & F for stainless steel barrel tower bolt of 300 mm length of extruded section, complete all as specified and directed
S & F for stainless steel barrel tower bolt of 300 mm length of extruded section fixed in repair, complete all as specified and directed
S & F for stainless steel barrel tower bolt of 200 mm length of extruded section, complete all as specified and directed.
S & F for stainless steel barrel tower bolt of 200 mm length of extruded section and fixed in repair, complete all as specified and directed.
S & F stainless steel handle 150 mm long, complete all as specified and directed.
S & F stainless steel handle 150 mm long, fixed in repairs, complete all as specified and directed.
S & F for stainlees steel sliding door bolt, of size 16 mm dia and 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy complete all as specified and directed.
S & F for stainlees steel sliding door bolt, of size 16 mm dia and 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy, fixed in repair complete all as specified and directed.
S & F 100 mm stainless steel butt hinges, complete all as specified and directed.
S&F stainless steel auto closing hinges for Ward robe and kitchen cabinet shutter. complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm, complete all as specified and directed.
S & F for Stainless steel wire cloth of size 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, fixed in repairs complete all as specified and directed.
S & F 20 mm dia stainless steel curtain rails with brackets fixed in repair complete all as specified and directed.
S & F for Aluminium door seal upto 1200 mm long on bottom of door complete all as specified and directed.
S & F for Magic eye for main door complete all as specified and directed.
S&F 18/19 mm thick pre-lam WPC board for cabinet boxes & shutters, cup boards, showcase etc with shelf and shutter with PVC liping on all exposed edges on same texture and shade including fixing arrangement, complete all as specified and directed.
S&F aluminium Hat pegs, solid body,125mm to 175 mm complete all as specified and directed.
S&F aluminium Hat and coat hooks,solid body, 175mm to 250 mm complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
M & L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4), complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in CM (1:6) complete all as specified and directed.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of old plastered surface of ceiling and applying two coat of white wash complete all as specified and as directed.
M & L for white washing three coats on ceiling including preparation of newly plastered surfaces complete all as specified and directed.
M & L for Complete removal of existing treatment on ceilings complete all as specified and directed by Engr In Charge.
M&L Preparing new ceiling surfaces undecorated plastered or unpalstered / perforated board surfaces and applying two coats of oil bound distempering over one coat of alkali resistant primer complete all as specified and directed.
M&L Preparing old ceiling surfaces undecorated plastered or unpalstered / perforated board surfaces and applying two coats of oil bound distempering over one coat of alkali resistant primer complete all as specified and directed.
M & L Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:6 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and directed. Note :- Integral water proofing liquid will be measured and paid seperately.
M&L for preparation of newly plastered or unplastered external wall surfaces as prescribed by manufacturer of paint and applying two coats of exetrior anti-fungal acrylic emulsion paint by roller / spray machine of required shade (walmista of Berger or equivalent in Asian/Nerolac Paint having three years performance warranty) over one coat of exterior water based primer of same make, complete all as specified and directed.
Note for item No 88 (i) (i) The newly plastered surface must be prepared by application of wall care putty in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the quoted rates. (ii) The work shall be got executed through authorised applicator of manufacture after concluding an MoU with Manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE / AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) After carrying out preparation of surface the same shall be got approved from GE / AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I). (vi) Arrangement of adjustable Scaffolding wherever required are deemed to be included in the rate quoted by the contractor.
M&L for preparation of old decorated surface of exterior wall by complete removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, washing the surfaces with bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti-fungal acrylic emulsion paint by roller / spray machine of required shade (walmista of Berger or equivalent in Asian/Nerolac Paint having three years performance warranty) over one coat of exterior water based primer of same make, complete all as specified and directed.
Note for item No 89 (i) The old surface must be prepared in a manner by application of wall care putty so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the quoted rates. (ii) The work shall be got executed through authorised applicator of manufacture after concluding an MoU with Manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE / AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) After carrying out preparation of surface the same shall be got approved from GE / AGE (I) before application of paint for each building. (v) The colour / shade will be all as approved by GE / AGE (I). (vi) Arrangement of adjustable Scaffolding wherever required are deemed to be included in the rate quoted by the contractor.
M & L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of internal wall by application of wall care putty of thickness 1mm to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller/spray machine complete all as prescribed by manufacturer of paint and as directed.
M & L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller/spray machine including 1mm thick wall putty all as specified and prescribed by manufacturer of paint and all as directed.
Notes for item No 91 & 92 : (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD complete all as specified and directed.
Roughening surfaces of old concrete floor by tucking, picking, sweeping clean and washing down with water to remove dust, etc. to receive the screed layer for laying floor tile complete all as specified and directed.
M&L for double charged vitrified tiles of any design and pattern, 600 x 600 x 8 to 9 mm thick, as in floor skirting etc Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B1b complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE
M & L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square/rectangular) area of each tile exe 0.11 sqm but not exe 0.18 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE
M & L for Non- skid coloured ceramic tiles of any design and pattern, 300 x 300 x 7 to 8 mm thick, in floor etc Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II complete all as specified and directed Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
M & L screed bed or bedding layer of mortar 15 mm thick cement mortar 1:6 for laying floor finished to receive floor tiles / granite complete all as specified and directed
M & L for coloured glazed ceramic tiles of any design and pattern, 300 x 450 x 7 to 8 mm thick, as in dado etc, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE
M & L for rendering 10mm thick in cement plaster 1:4 on brick work or concrete surfaces surfaces or surfaces other than fair face of brick work to receive glazed tiles / granite complete all as specified and directed.
M & L for Machine cut pre polished kota stone slab flooring 18-20mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, moulding and polishing complete all as specified and directed. (Screed bed shall be measured and paid seperately)
M & L for machine cut pre polished kota stone 18-20 mm thick slab in riser of steps laid in single piece, skirting, dado and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, moulding and polishing complete all as specified and directed. (Screed bed shall be measured and paid seperately)
M & L for screed bed or bedding layer of 20 mm thick in cement mortar 1:4 for laying floor finished to receive floor tiles etc. complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelves etc.laid, bedded and pointed in any mortar complete all as specified and directed.
M&L of 16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including full round nosing with necessary grinding, rubbing and polishing, complete all as specified and directed.
M&L of 16-18 mm thick pre polished udaipur green stone (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble including full round nosing with necessary grinding, rubbing and polishing, complete all as specified and directed.
Dismantaling water tanks exc 500 but n. exc 1000 ltrs complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tank 1000 liters capacity, white triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including all fittings complete all as specified and as directed.
S & F 20mm dia ball valve high pressure PTMT with epoxy coated aluminium rod & high pressure plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Taking up or down steel water tubing and connections 15 mm dia complete all as specified and directed.
Taking up or down steel water tubing and connections 20 mm dia complete all as specified and directed.
Taking up or down steel water tubing and connections 25 mm dia complete all as specified and directed.
M & L for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed.
M & L for Mild steel galvanized steel tubing of 15 mm bore with screwed socket joints as in concealed pipe work , medium grade, together with all fittings heavy duty (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
M & L for Mild steel galvanized steel tubing of 20 mm bore with screwed socket joints, medium grade, together with all fittings heavy duty (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
M & L for Mild steel galvanized steel tubing of 25 mm bore with screwed socket joints, medium grade, together with all fittings heavy duty (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
S & F in repairs 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe Complete all as specified and directed.
S & F in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe Complete all as specified and directed.
S & F in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle or concealed screwed both ends for iron pipe or for unions Complete all as specified and directed. Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make Jaquar Cat No-MQT-526NKN, Hindware cat No-F200005 , Cera cat No-8040301
S&F towel rail 600 mm long fixed with and including Chromium plated brass screws and wooden plastic cleats (Min weight 190 gms) complete all as specified and directed. Make Jaquar Cat No-AEC 1111N, Hindware cat No-F880005 , Cera Cat No-5003103
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule Complete all as specified and directed. Note- Chromium plated fitting shall be brought in store yard first as approved by GE / AGE (I) and will be issued subsequently for fixing at site.
S & F in repair, Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long Complete all as specified and directed. Make Jaquar Cat No-ACN1171N, CERA cat No-F5005301 , Prayag Cat No-BEA-45
Supply and fix glass corner shelf fancy type made of 6 to 7 mm thick sheet glass of size 250mm x 250 mm fixed with chromium plated brackets complete all as specified and directed. Make Jaquar Cat No-ACN1173, CERA cat No-F505101 , Prayag Cat No-BEA-44
S & F PVC connections 15 mm size 600 mm long with PTMT nuts of length, complete all as specified and directed.
S&F Wash basins with pedestal (full) vitreous china any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including brass chromium plate waste fitting Complete all as specified and directed. Make Jaquar Cat No-ECS-WHT-801 (WHB) & ECS-WHT-301(PEDESTAL), Hindware Cat No-Mario 10087 (WHB) & 11003(PEDESTAL) , Cera Cat No-S2040120(WHB) & S2090113(PEDESTAL)
S&F for Grating round 125 mm dia chromium plated, complete all as specified and directed.
S&F 600 mm x 450 mm bevelled edge mirror decorative type quality glass, mounted on 6 mm thick WPC board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers Complete all as specified and directed.
S & F in repairs PVC valveless, syphonic action type flushing cistern (Dual action), low level , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make .Complete all as specified and directed
S & F in repairs Vitreous china Squatting pan 'Orissa pattern, size 580 x 440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor Complete all as specified and directed.
S & F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints Complete all as specified and directed.
S & F in repair 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold', with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe Complete all as specified and directed. Make:- Jaquar Cat No-MQT-516AKN, Hindware cat No-F200014 , Cera Cat No-F1015451 Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S & F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold', with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe Complete all as specified and directed. Make Jaquar Cat No-MQT-516AKN, Hindware cat No-F200014 , Cera Cat No F-1015451 Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
Supply & fix in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed. Make Jaquar Cat No-MQT-517BKN(wall mixer) , EOS-542A(Shower) & ALE-536A(Shower arm, Hindware cat No-F200020 (wall mixer) & F160120 (shower with arm) , Cera Cat No F-2002401 (wall mixer), F-7040101 (Shower arm) & F-7020307CH (Shower) Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
Supply & fix wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed. Make Jaquar Cat No-MQT-517BKN(wall mixer) , EOS-542A(Shower) & ALE-536A(Shower arm, Hindware cat No-F200020 (wall mixer) & F160120 (shower with arm) , Cera Cat No F-2002401 (wall mixer), F-7040101 (Shower arm) & F-7020307CH (Shower) Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repairs towel rack fixed with and including CP brass screws and wooden/plastic cleats,complete all as specified and directed. Make Jaquar Cat No-ACN -1181N , Hindware Cat No-F880008, Parryware Cat No T6008A1, Cera Cat No F5003102 , Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S&F brass chromium plated body Health Faucet with hose & hook (complete set) fixed to angle / stop cock 15 mm dia Complete all as specified and directed. Make Jaquar Cat No- ALD 573 ,Hindware Cat No F160068, Parryware Cat No T9961A1, Cera Cat No F-5007110 Note- Chromium plated fitting shall be brought in store yard first as approved by GE / AGE(I) and will be issued subsequently for fixing at site .
S&F in repairs toilet paper holder chromium plated fixed to wall with chromium plated (CP) brass screws Complete all as specified and directed. Make Jaquar Cat No- ACN-1153N , Hindware model No F 880003, Parryware model No T6514A1, Cera Cat No F-5007110 Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F 32/40 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6kgf / sqcm fixed to walls, ceilings or in floors and as waste pipe of WHB / sink including PVC coupler and reducer fixed with cement solvent Complete all as specified and directed.
S & F in repairs Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 mm and bowl size 410 mm x 330 mm x 160 mm Complete all as specified and directed.
S & F Stainless steel kitchen plate rack 24 gauge thick sheet of over all size 31" x 26" x 10" fixed with steel screws and steel rawal plugs Complete all as specified and directed.
S & F Expanded metal cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia., or fixing with steel staples to wood or steel members, weight not exceeding 4 Kg per Sqm complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer Complete all as specified and directed.
M & L for post construction Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors Complete all as specified and directed.
M & L for post construction Anti termite treatmentAlong the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron Complete all as specified and directed.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation in hard / dense soil and getting out Complete all as specified and directed.
Demolition and breaking up drain pipes , 150 mm dia (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar Complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description & any position and not otherwise specifically provided for Complete all as specified and directed.
M & L Concrete bed to drain pipe 150mm dia incl. packing under and haunching against the sides of pipe PCC 1:4:8 type D2 (using 40mmgraded stone aggregate) Complete all as specified and directed.
M & L 150 mm salt glazed stoneware drain pipes Grade A laid in trenches and jointed with collars with following sizes laid on concrete bed complete all as specified and directed.
Returning filling in including spreading, levelling , watering and well ramming n exc. 25 cm in layers hard / dense soil complete all as specified and directed.
Removal of excavated surplus material at a distance exc.1.5 KM but n. exc 5.0 KM complete all as specified and directed.
M & L for Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 100/150 mm dia pipes complete all as specified and directed.
M & L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labour in CM 1:4 mixed with WPC / PCC 1:3:6 type B0 / Bk work in CM 1:4 as required at site complete all as specified and directed.
M & L for shifting aside of MS monkey case of any size & weight for repair / replacement of water tank, GI pipe, tank staging & refixing the same as required at site complete all as specified and directed.
S&F heavy duty stainless steel, ball bearing telescopic channel of 20-22 inch of make- Hettich/Godrej / Kaif or equivalent, complete all as specified and directed.
M & L for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high painted with thick paint complete all as specified and directed.
Cutting holes n exc 150 sq cm into or thorugh brick walls, built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in CM 1:3 or cement concrete 1:2:4 type B-1 complete all as specified and directed.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings etc built in cement mortar, incl providing fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard core, etc to store and rubbish not exc 50m. complete all as specified and directed.
Forming Jambs etc to opening incl cutting toothing and properly bonding in to old work also facing , jointing and pointing to match exisiting work complete in CM 1:4 complete all as specified and directed.
S&F brass chromium plated sink mixer with swinging pipe spout for hot & cold water complete all as specified and directed. Make- Essco Cat No MQT 521 S, Hindware cat No-200023, Cera Cat No.F1015501,
S&F brass chromium plated bottle trap fully casted 32 mm approx size 190mm and 125mm long, connecting pipe fixed to wall, complete all as specified and directed. Make- Essco, Hindware, Cera
M&L for treatment of spalled concrete cover of RCC slab as per the following course of action :- (a) Prepration of existing surfaces like chipping of unsound weak / loose concrete/cover of reinforcement & support the structure provisionally during repair work and maintaining them in position till required (b) Clean exist reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, etc, complete and applying two coats of alkaline rust converting primer Sika RustOff-100 or equivalent i.e Fosroc, Dr fixit with a coverage of 350gm/sqm on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats. (c) Providing and application of zinc rich epoxy antocorrosive protective coating for rebar corrosion protection system Sika Friazinc R® or equivalent i.e Fosroc, Dr fixit in 2 coats of 0.4 kg/m2. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/mm2 according to ASTM C 882-78.
(d) Supply and fixing additional MS TMT rebar Fe415 in various structural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive Sika AnchorFix 3030 or equivalent i.e Fosroc, Dr fixit Tropical or equivalent complete incl drilling of 10-12 mm dia upto 100 mm deep for rebaring ( MS Bar paid in separate item) (e) Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacture specification including preparation of surface by chipping and thoroughly cleaning of surface complete wherever required with Sikadur-32 LP or equivalent i.e Fosroc, Dr fixit in consumption of 0.4 kg/m2. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strength should be 10 MPa. (f) Rebuilding the section of structutal damaged spalled concrete or RCC elements to its original size in average thickness of 15-20mm by providing and applying with pre-batched, one component fiber reinforced cementitious patch repair mortar Sika® MonoTop® -122 F or equivalent i.e Fosroc, Dr fixit having compressive strength >= 50 N/mm2 (28 days) according to ASTM C 109; flexural strength >= 5N/ mm2 (7 days) according to ASTM C 293-79.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items shall be taken as per conditions separately) and making good disturbed surfaces of walls, floors with cement mortar 1:4,complete all as specified & directed.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc complete all as specified & as directed.
Taking down defective distribution board including MCBs and wooden boards all as specified and S & F distribution board factory made SPN 8 way, 240 volts, 50 Hz with 200 amps rated bus bar, double door metal type suitable for fixing MCBs including making good the surfaces to match with the exisitng all as specified and directed.
Taking down old unserviceable wooden meter box of any size & any type from wall by disconnecting all electrical connections complete all as specified & directed.
Taking down energy meter from wooden/steel meter box carefully and deposit to MES store yard complete all as specified & directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed drawn in and including concealed PVC conduit, medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates (ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding
(a) One light / ceiling fan/bell/exhaust fan point controlled by one no of one way switch
(b) One ceiling fan exhaust fan point controlled by one no of one way switch
(c) One exhaust fan point controlled by one no of one way switch
(d) One call bell point controlled by one no of one way switch
(e) One 5 pin 5/6 Amp socket outlet point on independent board controlled by one no of one way switch single pole 5/6 amps.
(f) One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sqmm size
(g) One light point controlled by two no of two way switch with two way point wiring
All as per item No 170 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLSH but unsheathed for 16 Amps power point on independent board and 2.5 sqmm FRLS H cable as earthwire complete all as specified and directed.
All as per item No 170 here-in-before but wiring with 4 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLSH cable for AC power point and 4 sqmm FRLS H cable as earthwire complete all as specified and directed. (AC point for officers quarter will be controlled by sheet metal enclosure)
S & F switch Modular 230 volts, single pole, one way 10 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed. Make:- Indoasian CP No 800000/ Legrand CP No 673401/ Cona CP No 14001
Supply and fix Modular switch white / ivory finish 6 Amps, two way, one module, 230 volts, 50 hz complete all as specified and directed. Make:- Indoasian CP No 800001/ Legrand CP No 673402/ Cona CP No 14006
Supply and fix Modular switch 1 way 16/20 Amps, 1 module, 230 volts, 50 hz white / ivory finish all as specified and directed. Make:- Indoasian CP No 800002/ Legrand CP No 673411/ Cona CP No 14016
Supply and fix Modular Socket outlet, 6A - 2 / 3 pin combined 2, module, 230 volts, 50 hz all as specified and directed. Make:- Indoasian CP No 800020/ Legrand CP No 673452/ Cona CP No 14066
Supply and fix Modular Socket outlet, 6/16 Amps - 2/3 pin combined 2, module, 230 volts, 50 hz all as specified and directed. Make:- Indoasian CP No 800022/ Legrand CP No 673455/ Cona CP No 14171
S&F bell push modular flush type, single pole one way 5/6 Amps, 1 module 230 volts, ISI marked, complete all as specified and directed. Make:- Indoasian/Legrand/Cona
S & F step socket type modular fan regulator 120/280 volts, 2 module with indicator ISI marked, complete all as specified and directed. Make:- Indoasian/Legrand/Cona
S & F Bell multi music type, single pole, 230/240 volts, 50 hz complete all as specified and directed.
S & F Bell buzzer single pole, 230/240 volts, 50 hz complete all as specified and directed.
S & F PVC polycarbonate ceiling rose 65/25 mm dia, isolated body having three terminals, complete all as specified and directed.
S&F LED tube light batten 20 watts 4 feet polycarbonate housing, translucent diffuser with LED light source, 2200 lumen, natural white , surge protection range 7-10KV, voltage protection range upto 440 V AC , system efficiency not less than 110 Lm/watt for the fitting , power factor>0.98 total harmonic distortation<10% , colour rendering index >70, coefficient colour temp 6500 K, fixed on site with all accessories LM79 and LM80 reports to be produced, BIS certification must complete all as specified and directed. Make:- Havells CP No LHEXACP7IN1J020/ C&S CP No LTTB4F20WLEDEW BATTEN/ Crompton CP No LDL-20-WW or equivalent model in Philips/Bajaj/Wipro
S & F surface mounted LED luminiare 18 watts 4 feet polycarbonate housing, translucent diffuser with LED light source, 2200 lumen, natural white , surge protection range 7-10KV, voltage protection range upto 440 V AC , system efficiency not less than 110 Lm/watt for the fitting , power factor>0.98 total harmonic distortation<10% , colour rendering index >70, coefficient colour temp 6500 K, fixed on site with all accessories LM79 and LM80 reports to be produced, BIS certification must complete all as specified and directed. Make:- Havells CP No LHEXACP7UN1W018/ Shakti CP No SZSLBMX018 or equivalent model in Philips/Bajaj/Crompton/C&S/Wipro
S & F surface mounted LED luminiare 10 watts 2 feet polycarbonate housing, translucent diffuser with LED light source, natural white , surge protection range 7-10KV, voltage protection range upto 400 V AC , system efficiency more than 120 Lm/watt for the fitting , power factor>0.98 total harmonic distortation<10% , colour rendering index >70, coefficient colour temp 6500 K, fixed on site with all accessories LM79 and LM80 reports to be produced, BIS certification must complete all as specified and directed. Make:- Havells CP No LHEXACP7UN1J010/ C&S CP No LTTB2F10WLEDEW BATTEN/ Crompton CP No LDL-10-WW or equivalent model in Philips/Bajaj/Wipro
S & F building security LED luminiare 1x20 watts polycarbonate housing made out of pressure die-cast aluminium alloy with toughened glass, IP-66, protection working on 240 V AC 50 Hz, consisting of reflecting lamp prewired with driver power factor>0.98, having over voltage protection range upto 440 volts, surge protection level>10 KV total harmonic distortation<10% , made up of long life LED chip (SMD) in modular with Ra<70 and LED lumen efficiency > 120 lumen/watt, coefficient colour temp between 5000K-6500 K, fixed on existing bracket including making necessary connection with 1.5 sqmm 3 core PVC flexible copper conductor cable1100 volts complete all as specified and directed. Make:- Havells CP No VLUMINASL20WLED757SASYBOPC/ Bajaj CP No BCLST 20W LED1/ Crompton CP No TRP-400-20-57-SL-LM-NSR or equivalent model in Philips/Bajaj/Wipro
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified and directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar complete all as specified and directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with 200 Amps rated bus bar complete all as specified and directed.
S&F distribution board factory made double door metal type for MCCB DB VTPN 4 way with 200 Amp bus bar 415 volts including MCCB 4 pole 40-63 Amp, 16 KA, adjustable thermal & fixed magnetic type complete all as specified & directed.
Supply and fixing miniature circuit breaker (MCB) of TPN 16-32 Amps 10 KA 'B' curve 415 volts, complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) of SPN 10-32 Amps 10 KA 'B' curve, 240 volts, complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) of SP 6-32 Amps 10 KA 'B' curve, 240 volts, complete all as specified and directed.
Supply and fix sheet metal enclosures with metal socket and plug top Single pole and neutral enclosure with a two pin and earth plug and socket complete, 230/240 volts, 50 hz with one single pole MCB SP 20 Amps complete all as specified and directed.
Supply and fix fresh air fan (Exhaust fan) AC single Phase 230/240 Volts of size 300m sweep blades, metalic body powder coated paint finish, power consumption 50 watt, air displacement 1290 cum/hour, 900 RPM complete with frame and louvers including making holes and making good disturbed surface in cement mortar 1:4 and fixing with nuts & bolts, complete all as specified & directed.
Supply and fix ventilation air fan AC single Phase 230/240 Volts of size 250m sweep blades, non metalic high quality engineering plastic body, power consumption 36 watt, air displacement 680 cum/hour, 1200 RPM complete with frame and louvers including making holes and making good disturbed surface in cement mortar 1:4 and fixing with nuts & bolts, complete all as specified & directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 1.5 KW capacity 25 litre, BEE 5 Star rated, 240 V, 50 Hz complete with all accessories such as safety valve, thermostate, NRV, Hot and cold water connection pipe all as specified and directed.
M & L for sub main wiring with two run of 4 Sqmm (nominal cross sectional area ) of single core unsheathed PVC insulated cables FRLS-H cable 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 19/20 mm or higher dia with & including necessary conduit accessories concealed / surface only on roof & colomn) type including 4 Sqmm stranded copper conductor PVC insulated cable as earth wire connected to common earth dolly complete all as specified & directed. Note : Two runs of phase and neutral wire and one run of earth wire with PVC conduit measured as one length or one RM .
M & L for sub main wiring with four run of 4 Sqmm (nominal cross sectional area ) of single core unsheathed PVC insulated cables FRLS-H cable 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 19/20 mm or higher dia with & including necessary conduit accessories concealed / surface only on roof & colomn) type including 4 Sqmm stranded copper conductor PVC insulated cable as earth wire connected to common earth dolly complete all as specified & directed. Note : Four runs of phase and neutral wire and two runs of earth wire with PVC conduit measured as one length or one RM .
Supplying,installation, testing & commissioning of three phase four wire, AC static Direct connected, Smart Prepaid Energy Meter, complying to BIS 16444, ISI marked in existing Meter Board Floor Panels, current range 10-60 Amp, 240 volts, accuracy class 1.0 UC1 category along with in built load control switch, containing provision for TOD & RTC, capable to define multiple tariff slabs, complete all as specified & directed. Meter shall support the following data:- (i) 15/30 min instantaneous data for voltage, current, power factor, power cumulative energy and frequency, daily and monthly billing survey for cumulative energy and max demand. (ii) Meter shall have connect/disconnect functionality operable for MDM/Billing software and prepaid features would be operable for MDM/Billing as per IS:15959 Part-2. (iii) Meter will support communication protocol through RF/4G/NB IOT with the software all as required at site and directed. In case of RF communication, the cost of DCU and repeaters are deemed to be included in the quoted rate for meter. (iv) Meter should support open communication protocol DLMS with the software.
Supplying,installation, testing & commissioning of single phase two wire, AC static Direct connected, Smart Prepaid Energy Meter, complying to BIS 16444, ISI marked in existing Meter Class 1.0 UC1, category along with in built load control switch containing provision for TOD & RTC, capable to define multiple tariff slabs, complete all as specified & directed. Meters shall support the following data:- (i) 15/30 min instantaneous data for voltage, current, power factor, power cumulative energy and frequency, daily and monthly billing survey for cumulative energy and max demand. (ii) Meter shall have connect/disconnect functionality operable for MDM/Billing software and prepaid features would be operable for MDM/Billing as per IS:15959 Part-2. (iii) Meter will support communication protocol through RF/4G/NB IOT with the software all as required at site and directed. In case of RF communication, the cost of DCU and repeaters are deemed to be included in the quoted rate for meter. (iv) Meter should support open communication protocol DLMS with the software.
Note for item No 201 & 202 :- (a) Meter should be capable to run in both prepaid and postpaid mode. (b) The meter would carry 5 years guarantee for free replacement thereafter it will be the responsibility of the service provider of the OEM to ensure the serviceability of meters for a further period of five years without any extra cost to deptt. The quoted rate deemed to be included this fact. (c) In case of cellular communication such as 4G, NB IOT, 5G etc. The meter should be demonstrated working with more than one telecom service provider available in Raiwala Cantt Area. (d) Meter should be enterable to third party software. Meter vendor should provide all the necessary protocols and passwords including LLS key, HLS key, authentication password, encryption password. (e) Meter shall be supplied with repeater battery backup of RTC. (f) The new meter will be fixed inside the existing MS/CRCA enclosure. (g) Other specification of meter shall be all as specified in PS (h) The quoted rate deemed to be inclusive of mentioned here but need to be executed for proper and smooth functioning of prepaid smart meter system.
Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted, of size not less than 900x900x250mm and maximum size suitable for fixing under metioned MCCBs, Pre paid meters, Multifunction meters 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated, bus bar mounted on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the following and size of panel suitable to fixing all below materials with required space as per IE rules:- (Capt Qtr main panel).(a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleeve and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings. ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three) INCOMING SUPPLY:- i) MCCB 100 Amps 25 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No. Make of MCCB -L&T/Siemens/Legrand/Schneider.
OUTGOING SUPPLY:- i) MCCB 40 Amps, 415 Volts, 50Hz, rupturing capacity 16 KA = 4 Nos, Make of MCB-L&T/Siemen /Legrend/Schneider. (ii) MCB SPN 10 - 32 Amps 230 volts, 50 Hz, rupturing capaicty 10KA=2 Nos. Make of MCB-L&T/Siemen /Legrend/Schneider. iii) Space required for 04 Nos Pre paid Electric Energy meter Three Phase AC 415 V, 10-60 Amps & single phase pre paid energy meter AC 240V, 5-10 Amps -01 No iv) DMC Connector 2 way 100 A for outgoing submain supply-5 Nos Panel wiring for control circuit with copper flexible 6.0 Sqmm & power wiring minimum 6 Sqmm flexible . Notes:- 1. The panel manufacturer should have following certification:- i) CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests) ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA. iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from AGE (I) Raiwala before fabrication and contractor visit the site beore desing the panel . 4. Panel board should be fully compartmentalized in accordance to form 4b of IEC 61439-1-2 and maintaing space between MCCBs, MCBs, meters as per IE rules. 5.There should be provision of seprate compartment for each energy meter with all necessary wiring as per approved drawing. 6. Three phase/single phase pre paid energy meter rate should be included on the quoted rate the contractor should arrange the tecnician to connect /link the pre paid meter to existing pre paid meter system sofware as per direction of department 7. The required wall cutting if required and plastering, PCC work, necessary clamp for handing panel all are included in the quoted rate.
Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted, of size not less than 900x900x250mm and maximum size suitable for fixing under metioned MCCBs, Pre paid meters, Multifunction meters 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated, bus bar mounted on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the following and size of panel suitable to fixing all below materials with required space as per IE rules:- (For JCO Qtr P-41-01 No panel, P-101 Bllock-02 Panle, P-54 Block-02 Panel, P-359 Block 01 Panel)-=Total=06 Panels (a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleeve and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings.ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three)INCOMING SUPPLY:- i) MCCB 40 Amps 25 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No. Make of MCCB -L&T/Siemens/Legrand/Schneider.
OUTGOING SUPPLY:- i) MCB SPN 25-32 Amps, 240 Volts, 50Hz, rupturing capacity 10 KA = 4 Nos, Make of MCB-L&T/Siemen /Legrend/Schneider. (ii) MCB SP 6-32 Amps 230 volts, 50 Hz, rupturing capaicty 10KA=2 Nos. Make of MCB-L&T/Siemen /Legrend/Schneider. iii) Space required for 05 Nos Pre paid Electric Energy meter single Phase AC 230 V, 10-60 Amps -05 Nos (4 Nos pre paid meter of 10-60 Amps and 01 No Pre paid meter 5-10 Amps) iv) DMC Connector 2 way 100 A for outgoing submain supply-5 Nos. Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible . Notes:-1. The panel manufacturer should have following certification:-i) CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests) ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA. iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from AGE (I) Raiwala before fabrication and contractor visit the site beore desing the panel . 4. Panel board should be fully compartmentalized in accordance to form 4b of IEC 61439-1-2 and maintaing space between MCCBs, MCBs, meters as per IE rules. 5.There should be provision of seprate compartment for each energy meter with all necessary wiring as per approved drawing. 6. Three phase/single phase pre paid energy meter rate should be included on the quoted rate the contractor should arrange the tecnician to connect /link the pre paid meter to existing pre paid meter system sofware as per direction of department 7. The required wall cutting if required and plastering, PCC work, necessary clamp for handing panel all are included in the quoted rate.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 50 sqmm 4 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement all as specified and directed. by Engr-in-charge. Note:(i)GI tubing required shall be measured and paid separately under relevant item. (iii) Heat shrink sleeve of 25mm long on HS joint for colour indication shall deemed to be included on the quoted rate.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sqmm 2 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement all as specified and directed. by Engr-in-charge. Note:(i)GI tubing required shall be measured and paid separately under relevant item. (iii) Heat shrink sleeve of 25mm long on HS joint for colour indication shall deemed to be included on the quoted rate.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 16 sqmm 4 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement all as specified and directed. by Engr-in-charge. Note:(i)GI tubing required shall be measured and paid separately under relevant item. (iii) Heat shrink sleeve of 25mm long on HS joint for colour indication shall deemed to be included on the quoted rate.
Excavation in trenches for taking out/laying of cable and pipe line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in soft / loose soil. complete all as specified and directed.
Returning, filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in each layer in soft/loose soil.complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point. complete all as specified and directed.
M & L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable (measurement to be taken after punning down consolidated thickness). complete all as specified and directed.
Supply and laying sub class 'B' bricks, old size laid flat over sand cushioning across the cable in trench for cable protection, complete all as specified and directed.
Supply, laying & joined Galvanised Tubing 50 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc for cable protection complete all as specified and directed.
M & L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of minimum size 150 mm X 100 mm in respect of width and thickness complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground. (earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate reinforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire up to 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid separately under relevant items
Note : Tenderers may note that amount of credit Rs 3,64,778.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/S AJIT CONSTRUCTION CO
M/s Arihant Builders
M/S SHANTI SARUP DINESH CHAND
Som Prakash Gupta
VEE SONS BUILDERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .