Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹22.6 L+₹2.6 L (13.2%)Rejected-Finance 164 ASRAF KHAN CHAWANI OPP HARTMAN COLLEGE BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹23.6 L+₹3.6 L (17.9%)Rejected-Finance THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹32.2 L+₹12.2 L (61.0%)Rejected-Finance | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹35.4 L+₹15.4 L (77.0%)Rejected-Finance | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
3 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR/ MAINT/ REPLACEMENT OF INTERNAL AND CONNECTED WORKS AT OTM OF HQ UB AREA, SIGNAL REGT, 101 FD REGT, 64 ADV HOSP, CE OFFICE AND OTHER CONNECTED AREA UNDER GE (WEST) BAREILLY.
2023_MES_631521_1
8165/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST BAREILLY
₹90,000
Yes
6 Feb 2024
7 Dec 2023
5 Jan 2024
7 Dec 2023
3 Jan 2024
22 Dec 2023
Amount
Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, casing-N-caping, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, shade conical etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and distemper / white wash / colour wash etc. complete all as specified and directed.
M & L for point wiring for one light point / bell point / fan point / 5 Ampere socket outlet point (Independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including non-metallic PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 2.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 2.00 hereinbefore but wiring for one light point, controlled by 2, two way switches complete all as specified and directed.
All as per item No. 2.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 5 Ampere complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, two-way 5 Ampere complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed.
S & F of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
S & F of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S & F of bell push button type single pole one-way 5 Ampere complete all as specified and directed.
S & F of ceiling rose PVC / polycarbonate isolated body 3 terminal, 230 volts AC ISI marked, complete all as specified and directed.
S & F of Lamp holders PVC / polycarbonate insulated body modular type with back plate suitable for batten fitting / angle fitting complete all as specified and directed.
S & F in repairs switch piano flush button single pole 230 volts, one-way 5 Ampere complete all as specified and directed.
S & F in repairs switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed.
S & F in repairs ceiling rose PVC / polycarbonate isolated body 3 terminal, 230 volts AC ISI marked, complete all as specified and directed.
S & F in repairs Lamp holders PVC / polycarbonate insulated body modular type with back plate suitable for batten fitting / angle fitting complete all as specified and directed.
S & F in repairs switch and socket combination 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
S & F in repairs switch and socket combination two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S & F in repairs single phase call bell ‘DING DONG’ or MUSICAL, AC 230 volts single pole complete all as specified and directed.
S & F in repairs socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
S & F in repairs socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S & F in repairs modular type switch 6 Ampere, one way, 1 Modules complete all as specified and directed.
S & F in repairs modular type switch 16 Ampere, one way, 1 Modules complete all as specified and directed.
S & F in repairs modular type socket outlet 6 Ampere, 2 and 3 Pin combination, 2 Modules complete all as specified and directed.
S & F in repairs modular type socket outlet 6 and 16 Ampere, 3 Pin for both rating (Total 6 Pins), 2 Modules complete all as specified and directed.
S & F in repairs modular type fan regulator step type, 120 Watt, 2 module complete all as specified and directed.
S & F in repairs fan regulator resistance / electronic step type, single phase 230 volts complete all as specified and directed.
S & F in repairs hylem sheet 3 mm thick of size 8'' X 11'' including cutting of sheet for fixing switch / socket complete all as specified and directed.
S & F in repairs hylem sheet 3 mm thick of size 8'' X 5'' including cutting of sheet for fixing switch / socket complete all as specified and directed.
S & F in repairs hylem sheet 3 mm thick of size 5'' X 5'' including cutting of sheet for fixing switch / socket complete all as specified and directed.
S & F in repairs MCB single pole and neutral, 240 volts, 20 to 32 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F in repairs MCB single pole, 240 volts, 6 to 32 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F in repairs MCB triple pole and neutral, 415 volts, 63 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S &F in repairs MCCB 16 KA,125 Ampere, thermal magnetic and electronic earth leakage module complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring any type and description upto 6.00 Sqmm size including all battens, coduits and the like with wooden gutties etc. and making good disturbed surfaces of wall, roof, floor etc. as per existing finishes complete all as specified and directed.
S & F of 1100 volts grade heavy duty 4.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 20 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 4.00 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S & F of 1100 volts grade heavy duty 6.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 6.00 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S & F in repairs sheet metal enclosure DB's 415 Volts, IP-42, vertical type, suitable for mounting MCCB's, TPN, 12 way with 200 Ampere rated copper bus bar complete all as specified and directed.
S & F in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirm to IS-13032 (1991) of 4 ways complete all as specified and directed.
S & F in repairs double door MCB distribution board sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS-13032 (1991) of 8 ways complete all as specified and directed.
S & F in repairs double door MCB distribution board sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS-13032 (1991) of 12 ways complete all as specified and directed.
Supply and Fixing in repairs 4 Pin CFL lamp 36 Watt complete all as specified and directed.
S & F in repairs 2 Pin CFL 14/16/18 W lamp/LED bulb thread type complete all as specified and directed.
S&F in replacement LED fitting with PVC extruded battern 20 watt 4 feet White/yellow colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed.
S&F in replacement LED fitting with PVC extruded battern 10 watt 2 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed.
S & F Side holder suitable for existing LED/FTL fittings as per site requirement complete all as specified and directed.
S & F in repairs building security light highly efficient front openable IP-65 LED street light with aluminium pressure die cast housing toughned glass in the front of peanut lense for batwing light distribution 25 watt including GI pipe bracket 32 mm dia with clamp including making all connections wih copper wire all as directed and specified.
S&F 2'x 2' LED recess/ surface mounted fitting 36 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F 2'x 2' inverter LED 2x2 panel is CRCA powder coated and IP 20 with battery back up and functioning as per product TDS recess/ surface mounted fitting 36 Watt, 230V, with high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S & F as in replacement aesthetically designed IP-65 LED post top with aluminium enclousere, powered with high power LEDs as light source and die cast heat sink, Alumnium PDC heat sink, opal PC diffuser and clear acrylic with all fixing arrangements as required at site of capacity 30 watt complete all as specified and directed.
M & L in repairs E-board false ceiling consisting of powder coated GI wall angle, main T and Cross T of 25mm x 25mm x 1.40 mm thick grid frame work, joist, angle / Tee as directed and mild steel wire hook not less than 6mm dia with arrangement for adjusting height of ceiling and including provn of 4mm thick E-classic board in pnel of size 600 x 600mm with necessary off cut including dismantling of existing false ceiling and taking down and refixing of electric fitting carefully complete all as specified and directed.
S&F in replacement of PVC non metallic casing caping of 25 mm size with accessories including dismentaling/takingdown of old unserviceable/broken PVC conduit/cashing caping fixed on surface/concealed inclduing making good the disturbed surface complete all as specified and directed
Supply and Fixing in repairs in replacement PVC insulated Flexible twin core,copper cable multistranded 24/.0020sqmm, 1100 V grade. complete all as specified and directed.
Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed.
M & L Re-winding of burnt fan motor of 1200/1400 mm sweep including internally and externally cleaning of fans and removing the burnt coil and re-winding of fans by super enameled copper wire of appropriate size, and re-assembling the fans and connecting with flexible copper wire of one mtr length and testing after repair complete all as specified and directed.
Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all as specified and directed.
Re-winding of exhaust fan motor of 450/300 mm sweep with appropriate size of super enameled copper wire, including re-assembling the fans and connecting with flexible copper wire of one mtr length complete all as specified and directed.
Supply and Fixing in repairs Condenser 2.5 Mfd complete all as specified and directed.
Supply and Fixing in repairs Condenser 3.5 Mfd complete all as specified and directed.
Supply and Fixing in repairs bush of fans of any size complete all as specified and directed.
Supply and Fixing in repairs insulating rubber real including Supply and replacing nuts, bolts with washers complete all as specified and directed
Supply and Fixing in repairs shaft of fans of suitable size complete all as specified and directed
Supply and Fixing in repairs of fan pins of suitable size for various type of fans / ceiling fans complete all as specified and directed.
Supply and Fixing in repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed.
Supply and Fixing in repairs fan down rod made out of 15 mm dia medium grade GI pipe, Med grade including threading on both end of pipe, drilling holes etc. as required including primer complete all as specified and directed.
Supply and Fixing in repairs fan conopy, suitable for various type ceiling fan complete all as specified and directed.
M&L for replacement and re-filling of glass wool as per norms of different type of geysers complete all as specified and directed by the Engr in Charge.
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed.
Maintenance and Servicing of split type air conditioner of capacity 1.5/2.0 TR of any make and type by removing , strip opening, cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensing and cooling coil and complete outdoor and indoor unit using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing of blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed.
Maintenance and Servicing of Window type air conditioner of capacity 1.0/1.5/2.0 TR of any make and type by removing , strip opening, and taking out the window type AC from the cabinet frame and cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensing and cooling coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing of blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning complete all as specified and directed.
Taking down/out unserviceable sealed/rotary/Reciprocating type compressor unit from the outdoor unit of Split type AC/ Window type ACs of capacity 1/1.5/2.0 Ton capacity including flushing of cooling system by Nitrogen gas. complete all as specified and directed.
S&F compressor (sealed unit) of following capacity in Split type/window type Air Conditioner complete and testing on full load all as specified and as directed by Engineer-in-Charge
(a) Reciprocating type 1.5 Ton
(b) Reciprocating type 2.0 Ton
(c) Rotary type 1.0 Ton
(d) Rotary type 1.5 Ton
(e) Rotary type 2.0 Ton
Supply, fixing , installation ,commissioning and testing of indoor unit complete with remote and valves of capacity 1.5 TR suitable for fixing up in the existing model of outdoor unit of Split ACs complete after disconnecting electrical connection and dismantling/ taking out indoor unit of split type ACs of any make and capacity from any place and installation, commissioning and testing after recharging of refrigerant gas to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distemper all as directed by Engineer-in-Charge.
Supply, fixing , installation ,commissioning and testing of indoor unit complete with remote and valves of capacity 2.0 TR suitable for fixing up in the existing model of outdoor unit of Split ACs complete after disconnecting electrical connection and dismantling/ taking out indoor unit of split type ACs of any make and capacity from any place and installation, commissioning and testing after recharging of refrigerant gas to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distemper complete all as specified and directed by Engineer-in-Charge.
S & F Remote suitable for various makes of Split type/Window ACs for 1/1.5/2.0 Ton capacity complete all as specified and directed by Engineer-in-Charge.
S & F Condenser motor of outdoor unit for 1.5/2.0 Ton capacity of AC as per existing makes complete all as specified and directed by Engineer-in-Charge.
S & F Indoor motor of Blower for 1.5/2.0 Ton capacity of split AC as per existing makes complete all as specified and directed by Engineer-in-Charge.
S & F Condenser PVC blade of fan motor for 1.5/2.0 Ton Split AC complete all as specified and directed by Engineer-in-Charge.
S & F SP plug and socket in sheet steel enclosure including SP MCB 32 Amps complete all as specified and directed by Engineer-in-Charge.
S & F Running capacitor 50/2,/50/6 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs complete all as specified and directed by Engineer-in-Charge.
S & F Running capacitor 45 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs complete all as specified and directed by Engineer-in-Charge.
S & F Starting capacitor 100/120 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs complete all as specified and directed by Engineer-in-Charge.
S & F Indoor capacitor of size 1.5 MFD/2 MFD suitable for 1.5/2.0 Ton AC complete all as specified and directed by Engineer-in-Charge.
S & F Swing motor suitable for indoor unit of 1.5/2.0 Ton Split type AC complete all as specified and directed by Engineer-in-Charge.
S & F Contactor suitable for 1.5/2.0 Ton AC as per make/size approved by Engr-in-Charge . L&T/C&S/SIEMENS complete all as specified and directed by Engineer-in-Charge.
S & F Copper tubing of size 3/8" including cutting and brazing complete all as specified and directed by Engineer-in-Charge.
S & F Copper tubing of size 5/8" including cutting and brazing complete all as specified and directed by Engineer-in-Charge.
S & F Copper tubing of size 1/4" including cutting and brazing complete all as specified and directed by Engineer-in-Charge.
S & F Copper tubing of size 1/2" including cutting and brazing complete all as specified and directed by Engineer-in-Charge.
S&F three core connection lead two single core, PVC insulated and sheathed Copper cable size 2.5 Sqmm including one earth wire of full guage complete all as specified and as directed Make : Plaza/Havells/Polycab
S & F Nitril vinyl insulation foam suitable for fixing with copper tube of size 3/8", 5/8" , 1/2" and 1/4" and packing with wide pvc tapes of black/white colour compete all as specified and directed.
S & F Reverse valve suitable for 1.5/2 ton ACs including dismantling and reinserting of valve and refilling of reqd refrigerant and testing compete all as specified and directed.
M & L for Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out indoor and outdoor unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge.
M & L for Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out window type air conditioning complete with frame cabinet of any make and capacity from any place and installation, commissioning and testing to another location including transportation cutting of hole on wall and making platform complete with wooden strip/iron frame for fixing of Window AC Cabinet and making good of disturbed surface with matching colour/distamper all as directed
Taking down unserviceable PCBs card with sensors of Split/Window type AC and refix the same after complete repair and testing as of Cap 1.5/2.0 ton complete all as specified by Engr in charge
Supply and gas charging with refrigerent gas as required in any make, split and window type Acs, to its full capacity, where less gas detected in the split type and window type air conditioners complete all as specified by Engr in charge
M & L for Disconnection, taking down desert coolers from any floor of building and cleaning /removing of old paint and painting with two coat of enamelled paint of colour as specified by Engr in charge over a coat of red oxide and internally with black bitumenous paint complete all as specified by Engr in charge
S&F in repair of following spares parts of desert coolers of different sizes including testing complete after dismantling of old respective unserviceable spares complete all as specified by Engr in charge
S & F Electric Fan motor of Desert/air cooler of capacity 1300-1400 RPM single shaft of power rating 100 - 150 watt 230 Volt 50 Hz Single phase complete all as specified by Engr in charge
S & F Water lifting submersible type tullu pump 18 watt and water lifting upto 1.8 Mtr for desert coolers complete all as specified by Engr in charge
S & F Float valve plastic ball for 15 mm dia bore of pipe of desert cooler with ISI mark complete all as specified by Engr in charge
S & F PVC stop cock suitable for 15 mm dia GI pipe ISI Mark complete all as specified by Engr in charge
S & F PVC connection 15 mm dia with CP nut 450 mm long ISI Mark complete all as specified by Engr in charge
S & F Capacitor 4 MFD complete all as specified by Engr in charge
S & F Set of legs with clamp and nut bolt & washer for mounting of fan motor on body for desert cooler complete all as specified by Engr in charge
S & F Aluminium Fan leaf blade complete all as specified by Engr in charge
S & F PVC fan leaf blade complete all as specified by Engr in charge
S & F Iron Stand made out of angle iron of each size 35x35x4mm for installation of desert cooler of height 3 to 6 feet, lengthxwidth as per site requirement on the ground floor,/Ist /2nd floor. complete all as specified by Engr in charge
S & F Switch regulator with controlling knob low med high control of any size complete all as specified by Engr in charge
S & F Wood wool pad, each packet set of three complete all as specified by Engr in charge (Note: Tie strip for fixing of pads must be included in the quoted rate)
S & F Wire mesh of Pannel doors/side grills for supporting of Wood wool grass pad of size as required at site as per panell door size complete all as specified by Engr in charge
S & F PVC water distributor heavy duty 15mm size fixed with bolts & Nut & washers complete all as specified by Engr in charge
S & F PVC elbow 15mm dia for inside water distribution complete all as specified by Engr in charge
S & F Front grill suitable for desert coolers complete all as specified by Engr in charge
NOTES: - (i) Tenderers may note that amount as given in schedule of credit will be deducted from the total quoted amount to work out the contract sum at the time of Acceptance of tender.
indiatraders
S S ELECTRICALS
M/s Yash Trading Company
LEEJA ENTERPRISES
VINYAK TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .