| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹36.4 L+₹3.2 L (9.67%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹40.9 L+₹7.7 L (23.1%)Rejected-Finance | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹43.1 L+₹9.9 L (29.7%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L4 | Rejected-Finance Not being lowest bidder | |
| 5 | L5₹44.1 L+₹10.9 L (32.8%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L5 | Rejected-Finance Not being lowest bidder |
| Sl No | Description | Qty | Unit | SRIVALLI ENGINEERS L9 | VIJAYA DURGA CONSTRUCTIONS L1 | SUPREET CONSTRUCTIONS L2 | SRI JAYANTH ASSOCIATES L7 | YVR CONSTRUCTIONS L3 | SAMPATH ENTERPRISES L4 | GVR CONSTRUCTIONS L5 | SRI VENKATA SAI MANIKANTA CONSTRUCTIONS L6 | LALITHA SAI INFRA L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down unserviceable main switches, DBs, bus bars chambers, MCB/MCCB Enclosures any capacity including all fittings and fixtures such as MCBs, isolator, MCCBs, MCB protected Power socket etc and removing from site complete all as specified and directed. | 121 | Each | 55 ₹6,655 | 90 ₹10,890 | 80 ₹9,680 | 40 ₹4,840 | 30 ₹3,630 | 30 ₹3,630 | 35 ₹4,235 | 25 ₹3,025 Lowest | 90 ₹10,890 |
| 2.00 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. | 200 | RM | 45 ₹9,000 | 25 ₹5,000 | 15 ₹3,000 Lowest | 50 ₹10,000 | 30 ₹6,000 | 30 ₹6,000 | 30 ₹6,000 | 35 ₹7,000 | 54 ₹10,800 |
| 3.00 | M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length) | 100 | RM | 220 ₹22,000 | 180 ₹18,000 | 250 ₹25,000 | 200 ₹20,000 | 180 ₹18,000 | 190 ₹19,000 | 185 ₹18,500 | 175 ₹17,500 Lowest | 198 ₹19,800 |
| 4.00 | M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length) | 100 | RM | 345 ₹34,500 Lowest | 440 ₹44,000 | 550 ₹55,000 | 390 ₹39,000 | 380 ₹38,000 | 390 ₹39,000 | 385 ₹38,500 | 370 ₹37,000 | 459 ₹45,900 |
| 5.00 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 1.5 sqmm complete all as specified and as directed. | 300 | RM | 165 ₹49,500 | 70 ₹21,000 Lowest | 70 ₹21,000 Lowest | 400 ₹1,20,000 | 110 ₹33,000 | 120 ₹36,000 | 115 ₹34,500 | 100 ₹30,000 | 144 ₹43,200 |
| 6.00 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 2.5 sqmm complete all as specified and as directed. | 200 | RM | 187 ₹37,400 | 105 ₹21,000 Lowest | 120 ₹24,000 | 150 ₹30,000 | 130 ₹26,000 | 140 ₹28,000 | 135 ₹27,000 | 115 ₹23,000 | 153 ₹30,600 |
| 7.00 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 4.0 sqmm complete all as specified and as directed. | 200 | RM | 192 ₹38,400 | 140 ₹28,000 Lowest | 140 ₹28,000 Lowest | 170 ₹34,000 | 150 ₹30,000 | 160 ₹32,000 | 155 ₹31,000 | 145 ₹29,000 | 180 ₹36,000 |
| 8.00 | S&F MCB protected power socket modular type with Steel Enclosure including 20 Amps MCB SP complete all as specified and as directed | 65 | Each | 910 ₹59,150 | 780 ₹50,700 Lowest | 1,050 ₹68,250 | 920 ₹59,800 | 850 ₹55,250 | 900 ₹58,500 | 950 ₹61,750 | 960 ₹62,400 | 999 ₹64,935 |
| 9.00 | S&F MCB protected power socket (3P+N+E) e with Steel Enclosure including 32 Amps MCB FP complete all as specified and as directed | 2 | Each | 5,500 ₹11,000 | 3,000 ₹6,000 Lowest | 3,900 ₹7,800 | 5,050 ₹10,100 | 5,000 ₹10,000 | 5,000 ₹10,000 | 6,000 ₹12,000 | 5,600 ₹11,200 | 8,100 ₹16,200 |
| 10.00 | S & F Vertical TPN DB double door,IP43 for provision of MCCB upto 250 A as incomer ,8 way with 200 A rating busbar complete all as specified and as directed. | 5 | Each | 9,600 ₹48,000 | 8,900 ₹44,500 Lowest | 10,500 ₹52,500 | 9,500 ₹47,500 | 9,500 ₹47,500 | 9,500 ₹47,500 | 10,000 ₹50,000 | 10,500 ₹52,500 | 9,999 ₹49,995 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Aug 2025, 6:00 pmClosed
GARRISON ENGINEER (NAVAL BASE)
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
REPAIR/REPLACEMENT AND MAINTENANCE OF MISC E/M EQUIPMENT INCLUIDNG BUILDING SECURITY LIGHTS WITH FITTING/FIXTURES AND ALLIED WORKS OF E/M INCLUDING INDOOR LT PANELS, LIGHTNING PROTECTION ,DISTRIBUTION BOARD ,FLOOR PANELS, INSULATION MATS , ACS,
2025_MES_723334_1
C/8546/25-26/E8 TOKEN 67 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹90,000
Yes
9 Dec 2025
30 Jul 2025
27 Aug 2025
30 Jul 2025
20 Aug 2025
13 Aug 2025
Amount
Taking down unserviceable main switches, DBs, bus bars chambers, MCB/MCCB Enclosures any capacity including all fittings and fixtures such as MCBs, isolator, MCCBs, MCB protected Power socket etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 1.5 sqmm complete all as specified and as directed.
S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 2.5 sqmm complete all as specified and as directed.
S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 4.0 sqmm complete all as specified and as directed.
S&F MCB protected power socket modular type with Steel Enclosure including 20 Amps MCB SP complete all as specified and as directed
S&F MCB protected power socket (3P+N+E) e with Steel Enclosure including 32 Amps MCB FP complete all as specified and as directed
S & F Vertical TPN DB double door,IP43 for provision of MCCB upto 250 A as incomer ,8 way with 200 A rating busbar complete all as specified and as directed.
S & F Vertical TPN DB double door,IP43 for provision of MCCB upto 160 A as incomer ,4 way with 200 A rating busbar complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 3 Pole, 100 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 4 Pole, 100 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 4 Pole, 125 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release , 415 Volt, 25 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release 415 Volt, 36 KA, 4 Pole, 250 Amps Capacity complete all as specified and as directed.
S & F MCCB with fixed thermal and fixed magnetic release 415 Volt, 25 KA, 4 Pole, 400 Amps Capacity complete all as specified and as directed.
S & F in repair Spreaders, 4 pole suitable upto 250 Amps complete all as specified and as directed.
S & F in repair Spreaders, 3 pole suitable upto 250 Amps complete all as specified and as directed.
S & F MCCB enclosure IP 43 with solid neutral link suitable for 4 pole MCCBs complete and making good disturbed surfaces complete all as specified and as directed. Note :- MCCB will be measured and paid under respective item
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying well burnt bricks, fly ash bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
S & F in repair IP 66 junction box made of impact resistance polycarbonate & heat resistant materials of size 200x160x98mm mm, dust proof, water tight, light weight, acid resistant, corrotion proof insulated and shock proof, fire retardant, self extinguishing, helogen & silica free non toxic material, UV resistant with internally embedded gasket and fitted with required terminals alongwith type test certificate and veryfied by glow-wire test in accordance with IEC60695-2-11 complete all as specified and directed directed. (Make : HENSEL, Cat No : KF9255 or equivalent model of make as per list of manufacturer)
S & F in repair LED outdoor Security light fittings, Min IP 65 rated, aluminium die cast housing with powder coating, pole mounted, 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repair 32 mm dia light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket arm 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed complete all as specified and directed.
S & F in repair LED outdoor Flood light fittings,50 Watt, 230 Volts AC , made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED outdoor Flood light fittings, 70 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED outdoor Flood light fittings, 100 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED outdoor Flood light fittings, 150 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair circular highbay LED light fittings, 200 Watt, 230 Volts AC with toughened glass, upto150 lm/W with10 kV SPD with IP66 protection with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED light fittings, 1x4', 40 Watt, 230 Volts AC with high performance, commercial grade solution industrial application with impact and corrosion resistant, IP65 rating complete with driver and lamp and with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repair 25 Watt, 230 Volts AC Post Top Lantern, outdoor type with decorative post top for 360 Degree indirect light, IP 65 protection with impact and corrosion reisitant complete with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed.
S & F in repair 40 Watt, 230 Volts AC Post Top Lantern, outdoor type with decorative post top for 360 Degree indirect light, IP 65 protection with impact and corrosion reisitant complete with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed.
S & F in repairs LED light fittings, ceiling mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 2'x2', 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, IP 40 rated,PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repair 10 Watt, 230 Volts AC, LED Bollard light fittings, efficient light distribution, Min IP 65 rated, outdoor type with decorative light with impact and corrosion resistant with driver and lamp and with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp and making good disturbed surfaces complete all as specified and directed.
S & F in repair 40mm bore, Steel water tubing, galvanised, medium grade with all fittings laid in trenches etc complete all as specified and directed.
S & F in repair 50mm bore, Steel water tubing, galvanised, medium grade with all fittings laid in trenches etc complete all as specified and directed.
S & F in repair Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
Supply, Install, Testing & Commissioning of 1HP, Booster pump, electric driven suitable for head range 6 to 41m, discharge range 12 LPM to 84 LPM, suction/delivery size 25x25mm, single phase including connecting and including dismantling the existing unserviceable pump and removing from site of work to MES store yard and depositing the same complete all all as specified and directed. (Make:-Kirlosker Cat No. CPBS 73624V or equivelant of make as per List of manufacturer's).
S & F in repair DOL starter switch with 1NO+1NC complete working on AC supply upto 16 Amp capacity complete all as specified and directed.
Disconnecting / dismantling (Electrically and mechanically) 3-ph, 440 volts ,50 Hz electrical motor from monoblock pump set of 2 HP capacity and shifting to workshop , opening the motor and cover,taking out motor and burnt stator winding and rewind the motor with appropriate gauge weight and turns of super enamelled copper wire using proper insulating material varnishing with class-1 varnish,reassembling the motor completely and connecting and testing complete all as specified and directed. Note : (i)The cost of minor spare parts require shall deemed to be included in quoted rate. (ii) The cost of transportation from site of work to workshop and back after rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor's workshop and shall be re-fixed at site within 05 days after taking down from site. Any delay after 05 days shall be penalised @ Rs. 100.00 per day.
Supply, fix, installation and commissioning BLDC ceiling fan of less noise, silent operation, speed controlable by regulator, light colour, conforming to IS-374-2019, 1200 mm sweep, 230 Volts, BEE 5 Star rating, any Govt recognised Lab tested, power factor >0.94 Wattage and not more than 35 Watt, air delivery not less than 215cmm and all accessories such as down rod etc and connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan and fixing in existing position including taking down existing unserviceable ceiling fan of any descriptions and deposited at MES store yeard complete all as specified and directed. (Note: Ceiling fan should have minimum 2 years manufacturer's warranty) (Make : USHA /Havell's/ Bajaj/ CG)
S & F Exhaust fan, 600 mm sweep, heavy duty, metal body ,900 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S & F Exhaust fan, 450 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S & F Exhaust fan, 300 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S & F PVC body Exhaust fan, 250 mm sweep, AC, single phase, 1200 RPM complete with all accessories and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed
S&F in repair of 10 to 16 Sqmm size pin type aluminium thimble for terminate electrical wires/cables connection in a professional manner to minimizing current leakage and hence avoids overheating or electrical failure due to loose connection complete all as specified and directed.
S&F in repair of 25 to 35 Sqmm size pin type aluminium thimble for terminate electrical wires/cables connection in a professional manner to minimizing current leakage and hence avoids overheating or electrical failure due to loose connection complete all as specified and directed.
S&F in repair of 50 Sqmm size pin type aluminium thimble for terminate electrical wires/cables connection in a professional manner to minimizing current leakage and hence avoids overheating or electrical failure due to loose connection complete all as specified and directed.
S&F in repair of 4-10 Sqmm size copper thimble for terminate electrical wires/cables connection in a professional manner to minimizing current leakage and hence avoids overheating or electrical failure due to loose connection complete all as specified and directed.
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 120 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed.
M & L for complete checking of LT panel board installed at various locations of MD ACCN block, checking of electrical connections such as thimbles, spring nuts, rubber gasket, window glass cover and refixed the same properly in position including replacement of such minor items (if any) as required at site complete all as directed by the Engr-in-Charge. Note : Cost of minor items will deemed to be included in quoted rate.
Material and Labour for preparation of old metal surfaces of Panel Boards after complete removal of existing painting over 10cm width or girth not otherwise described and applying two coats of enamel paint (1st quality) of simens grey colour over a coat red oxide zinc chrome primer and marking the Qtr No, Panel Board No in front side complete all as specified and directed by engineer in Charge. (Note: Adjoing areas there to properly covered befor painting. Adjoing areas, floor, walls are to cleaned free of paint spillage after painting work. If Paint spill is not cleaned to match with exsting surface a panel recovery @ Rs.200/- per location will be made from payments due to the contractor).
S & F in repair UPVC Panel cable trunking casing and capping of size 100x75 mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S & F in repair UPVC Mini/Maxi trunking profile with cover of size 50x50mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S&F in repair transparent window glass cover of size 150mmx150mm, 3 mm thick sheet glass suitable for LT panel complete all as specified and directed
S & F in repair indication lamp (Red,Yellow,Green),22.5 mm dia monitor, 240 volt Ac, suitable for panel board complete all as specified and directed.
S & F in repair LED indication lights complete set of two (Red,Green),including necessary connection complete all as specified and directed.
S & F in repair avaiation obstruction light, LED type integral light comprising of aluminium housing with polycarbonate enclosure with LED lamp ,driver and all accessories and connection complete all as specified and as directed. Make: Bajaj Cat Part No BGAV 302LED or equivalent model of make as mentioned in list of manufacturer under PS
S & F in repair 20W, LED Flame proof lights with IP 65 protection complete with all accessories all as specified and as directed. (Make : Model no EXTN1LT8-16/20 of Crompton or equivalent of make as per List of Manufacturer's)
Supply , laying and testing 32 mm bore High density poly ethylene pipes (HDPE) of pressure rating PN10 fixed including all fittings complete to walls, ceilings or in floors ,tranches etc including taking out old one complete all as specified and directed
Drilling, tapping and connecting from existing HDPE pipe up to 65 mm dia for branch connection including all fittings complete all as specified and directed
S & F in repair 32 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair gun metal water sprinkler with rotary sparay heads/nozzles 3/4 inch thread complette all as specifies and directed
S & F in repairs GI hot dip powder coated Perforated Cable Tray of Size 300mm wide, 75mm Deep, made with 2mm thick Sheet, with Perforation not more than 17.5%, in convenient sections, joined with connectors including all coupler,Tees, Right Angle Bends, Suspenders, Bolts, Nuts, Washers etc and Cable tray fixing iron brackets with suitable size and connecting accessories complete all as specified and as directed.
Supply and fixing in repair vertical electric water heater, storage type, shock resistant stainless steel outer body, high quality steel inner tank with glasslined Coated with high density PUF insulation, fitted With specially designed acrificial magnesium anode to prevent corrosion due to hard water ,100% copper heating element upto 2 KW, 230 volts, capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, 4 nos fixing bolt of suitable size including nuts and washer etc,2 nos PVC connection pipe and making the electrical connection with and including 16A Plug Top including testing and deposit of unserviceable water heater of any descriptions at MES store yeard complete all as specified and directed. Make:- Crompton , Havells, Racold , Bajaj,V-Guard Note : Contractor Shall submit manufacturer test report as per BIS to GE before payment. Old geyser shall be submitted to store
S & F in repairs electronic Control Card i.e PCB boards non inverter type indoor/outdoor suitable for 1.5 / 2.0 TR capacity Split/Tower AC’s as per the existing make and specifications and making connections etc complete all as specified and as directed.
S & F in repairs electronic Control Card i.e PCB boards inverter type indoor/outdoor suitable for 1.5 / 2.0 TR capacity Split/Tower AC’s as per the existing make and specifications and making connections etc complete all as specified and as directed.
Supply and fix in repair liquid valve 3/8' for medium temperature walk in cold room all as specified and as directed.
Supply and fix in repair suction valve 5/8' for medium temperature walk in cold room all as specified and as directed.
Supply and fix in repair suction valve 5/8' for medium temperature walk in cold room all as specified and as directed.
Supply and fix in repair condension fan motor single phase 250 Watt 50 hz as per sample for - temperature walk in cold room all as specified and as directed.
Supply & fix in repair of running capacitor for walk in cold room complete all as specified and as directed.
Supply & fix in repair of starting capacitor for walk in cold room complete all as specified and as directed.
Supply & fix in repair of overload relay protection for walk in cold room complete all as specified and as directed.
Supply & fix in repair of compressor contactor for walk in cold room complete all as specified and as directed.
Supply & fix in repair of filter drier for medium temperature walk in cold room complete all as specified and as directed.
Supply & fix in repair of solenoid valve as per sample for walk in cold room complete all as specified and as directed.
Supply & fix in repair of copper condensor with aluminium fins as per sample for walk in cold room complete all as specified and as directed.
Supply & fix in repair of axial air flow fan for evaporator of walk in cold room complete all as specified and as directed.
Supply and fixing in replacement of copper tubing of 3/8” dia suitable for suction / discharge line of split type AC complete all as directed.
Supply and fixing in replacement of copper tubing of 5/8” dia suitable for suction / discharge line of split type AC complete all as directed.
S & F in repair smart control panel for walk-in-cooler as per existing make and model . Blue star Model No. CSDTIC 520000 Note :- Item no 82 to 96 are considered for walk-in-cold room of capacity 1.0/1.5 Ton
Note for Item no 80 to 96:(i) Repai/replacement of defective components /parts/ accessories, checking and testing of ACs shall be carried out by the authorised personnel of authorised dealer of the system or throgh authorised AC mechanics and quoted rate shall deemed to include all this aspect .The contractor shall submit the Memorandum of Understanding (MoU) on stamp paper duly notarized with Original Equipments Manufacturer (OEM) or their accredited/authorized agencies/ authorised AC mechanics having 10 years experience in all type of AC repair works / registered MES AC contractors or other contractors listed in appropriate category of CPWD/ Railways/ Other Government Agencies as approved by GE as applicable to the effect that repai/replacement of defective components /parts/ accessories shall be carried out under their overall supervision, maintenance and direction/ instructions within ten days after acceptance of tender, failing which the contract will be liable to be cancelled in terms of General condition of contract (IAFW-2249). (ii) Minor spares not included in this schedule but required for smooth functioning of the system shall be provided by the contractor without any extra cost to the Govt. (iii) The contractor shall be responsible for handing over the complete AC system in serviceable condition at the time of completion of works duly inspected by the Engr-in-Charge jointly and inspection report of servicieablilty state of complete system shall be submitted.
SUPREET CONSTRUCTIONS (BID ID -3400148)
YVR CONSTRUCTIONS (BID ID -3399892)
SAMPATH ENTERPRISES (BID ID -3398488)
GVR CONSTRUCTIONS (BID ID -3400644)
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS (BID ID -3400478)
SRI JAYANTH ASSOCIATES (BID ID -3400176)
LALITHA SAI INFRA (BID ID -3400169)
SRIVALLI ENGINEERS (BID ID -3399937)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .