Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹1.2 L
Closing Date
7 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
Additional City Engineer (I/C)
SITC of Vaccum Circuit Breaker Panel with Allied Accessories and Civil work at Various Location of Water management Unit.(Re-Tender)
315973
RMC/WMU- WW & DRAINAGE/01 (Re-Tender)
Open
Supply,erection and Commissioning
Rajkot
15 documents required · 14 mandatory · 1 optional
₹4,500
Rajkot Municipal Corporation
₹1.2 L
20 Jun 2026
20 Jun 2026
20 Jun 2026
7 Jul 2026
20 Jun 2026
NAME OF WORK:- SITC of Vaccum Circuit Breaker Panel with Allied Accessories and Civil work
at Various Location of Water management Unit. (Re-Tender)
Tender No: RMC/WMU- WW & DRAINAGE/01
Milestone dates for e-tendering is as under
1. Downloading of e-Tender documents Dt.20/06/2026 to Dt.07/07/2026 up to 18:00
2. Pre-bid meeting in the O/o Addl. City Engineer Dt.26/06/2026 at 11:00 AM. Bidders shall
at CENTRAL ZONE have to post their queries if any on e-mail
[email protected] before Dt.25/06/2026.
3. Last Date of Online submission of e–Tender Dt.07/07/2026 up to 18:00 hrs
4. Physical submission of EMD, Tender fee as per Dt.13/07/2026 up to 18:00 hrs
financial criteria by RPAD, and all other
documents should be submitted online.
5. Verification of submitted documents (EMD, e - Dt.14/07/2026 (If possible)
Tender fee, etc. and Opening of online tender
6. Opening of Price Bid (if possible) Dt.15/07/2026 (If possible)
7. Bid Validity 120 days.
Add.City Engineer
Water Management Unit
Rajkot Municipal Corporation
Bedi Naka Office, Nr. Keshar E Hind Bridge,
E mail : [email protected]
1.0 FORM OF PRICE PROPOSAL
2.0 SCHEDULES OF RATES & PRICES
SCHEDULE A - PAYMENT SCHUDULE
SCHEDULE B - PRICE
SCHEDULE C - BILL OF QUANTITIES (BOQ)
FORM OF PRICE PROPOSAL
Bidders are required to fill up all blank spaces in this Bid Form
Municipal Commissioner,
Rajkot Municipal Corporation
Dr.Ambedkar Bhava
Dhebarbhai Road
SUB : SITC of Vaccum Circuit Breaker Panel with Allied Accessories and
Civil work at Various Location of Water management Unit. (Re-Tender)
We have examined the Conditions of Contract, Employer's Requirements, Schedules, Addenda
Nos and the matters set out in the Appendix hereto. We have understood and checked
these documents and have not found any errors in them. We accordingly offer to design,
execute commission and to maintain for the two years the said Works and remedy any defects,
fit for purpose in conformity with these documents and the enclosed Proposal, for the fixed
lump sum of Rs. or other such sums as may be
determined in accordance with the terms and conditions of the Contract. The above amounts are
We agree to abide by this Bid until 120 days and it shall remain binding upon us and maybe
accepted at any time before that date. We acknowledge that the Appendix forms part of our
If our bid is accepted, we will provide the specified performance security, commence the
Works as soon as reasonably possible after receiving the Employer's Representative's notice to
commence, and complete the Works in accordance with the above-named documents within the
time stated in the Appendix to Technical Proposal.
Unless and until a formal Agreement is prepared and executed, this Bid, together with your
written, acceptance thereof, shall constitute a binding contract between us.
We understand that you are not bound to accept the lowest or any bid you may receive.
We are, Gentlemen
Yours faithfully
Signature in the capacity of duly authorized
to sign bids for and on behalf of
SCHEDULES OF RATES & PRICES
General terms, condition and detail of works: SITC of Vaccum Circuit Breaker Panel with
Allied Accessories and Civil work at Various Location of Water management Unit.
1. Tenderer has to submit tender documents online at https://rmctender.nprocure.com and
If tender fee, EMD in terms of Demand draft than Submit on address given above by
RPAD only on or before the prescribed date and time mentioned in the milestone dates
for e-Tendering.
2. No joint venture is permitted.
3. Conditional tender will not be accepted and no advance payment against the tender will
be made by department.
4. The rate should be clearly quoted in figure and words in online price bid only. The rates
quoted in any other manner will not be acceptable.
5. The rate should be Exclusive of GST and all other taxes & duties i.e. transportation
charges etc are inclusive.
6. Tender should be submitted along with relevant documents asked in tender. Tender
without any document will liable to reject.
7. Time for completion of work is One Year from the date of work order. All erection,
installation, testing and commissioning of all materials should be completed in One
Year. In case of late handing over, penalty will be imposed on tenderer as per RMC
8. Contractor shall guarantee the work for a period of 24 months from the date of issue of
Completion Certificate.
9. Tender should be completely filled in all respects, incomplete tenders are liable to reject.
10. The bidder shall have to identify various risks involved in this work and shall
accordingly frame the methodology for constricting the same.
11. The rates and prices shall be submitted in the formats given in the online Price
Schedules. Rates and prices received in any other formats will be rejected and the Bids
will be disqualified.
12. It will be entirely at the discretion of the Owner to accept or reject the bidder’s proposal,
without giving any reasons whatsoever.
online schedule.Prices quoted in online Schedule only will be considered for price
evaluation & shall form apart of the Contract Agreement.
successful bidder.
15. The bidder shall be deemed to have allowed in his price for provision, maintenance and
final removal of all temporary works of whatsoever nature required for construction
including temporary bunds, diverting water, pumping, dewatering etc. for the proper
execution of works. The rates shall also be deemed to include any works and setting out
that maybe required to be carried out for laying out of all the works involved.
16. Where there is a discrepancy between the unit rates and the amount entered, in the price
schedule the latter shall govern.
Specifications and other sections of these bid documents and these documents are to be
taken as mutually explanatory of one another.
18. Prices quoted by the bidder shall be firm for the entire period of Contract without any
19. The bidder shall interpret the data furnished and carryout any additional survey work, or
investigation work required at his own cost.
20. The prices quoted shall also include the cost of materials utilized for testing.
21. The bidder should acquaint him self with the site conditions including the access to Work
site. The successful bidder shall have to make suitable access to worksites at his own
cost. These accesses will be used by the other Contractors working for RMC.
22. From each Running Account Bill, labourcess, Income Tax, Value Added Tax (VAT),
Professional Tax and other taxes prevailing from time to time will be deducted as per
23. The contractor shall have to avail PF Code as per the prevailing Circular of Government
for the employees on work. The process for preparation of bill will be taken uponly after
submission of the Challan for the amount of P.F.deposited every month for the
employees on work, which will binding to the contractor. The required documents shall
have to be submitted every month by the contractor to the competent authority.
24. The prices shall have to be quoted firm & fix including all the taxes (exclude GST)&
duties without any statutory variation. RMC will not consider any statutory variation as
well as the price rise in the market and if any, those shall be on account of contractor.
25. The work contract tax shall be borne by the agency.
26. The material / Items as supplied by the contractor and as found necessary by engineer-in-
charge will be inspected by Project Management (PMC) of this project.
27. The contractor shall have to borne all charges for testing and inspection purpose
including TPI agency charges. TPI agency charges will be born by contractor.
28. The contractor shall have to provide his own level instrument for this work.
29. In excavation, the decision regarding classification of strat a shall rest with the Engineer-
In-Charge and his decision in this regards shall be final and binding to the Contractor.
30. The rates of work are inclusive of shoring, strutting, dewatering etc. complete and hence
no any extra payment shall be made for the same.
31. During work activity, proper care must be taken for labour safety and all the provisions
of the labour laws must be followed by the contractor.
32. The G.A. Drawings provided with the tender document is only for reference. Contractor
(Agency) shall have to prepare GA drawing considering actual plot size and site situation
and GA drawings shall have to be approved from Engineer-incharge of Rajkot Municipal
Corporation and/or TPI Agency without any extra cost.
33. In case of any ambiguity found in the tender or in the specifications/drawings etc.,
Engineer-in-charge is empowered to take necessary decision for rectification and the
same shall be final and binding to the contractor.
34. Appendix provided in tender is a sample format. The bidder shall furnish the details of
concern tender duly signed by Chartered Accountant and Tenderer. List of Ongoing
Work (i.e. Running Work details) must be attached. Ongoing work list shall include
details name of work, total amount of awarded work, Work done amount till date,
details name of work, total amount of awarded work, Work done amount till date,
pending work today. In this Appendix, the details of experience and amount shall have to
be mentioned in the respective column.
35. For any type of license regarding labour etc. has to be achieved by agency
36. This office Circular bearing Order are uploaded in tender document. The Contractors
quoting their rates shall have to read, implement, and submit the same duly signed along
with the documents to be submitted during physical submission.
37. In reference to the above Circular and Order cited at above, the Contractor firm who
have quoted their rates for this work will be called in person for verification of original
documents. The date and time for verification of original documents will be intimated to
the Contractors.
38. Before procurement of Material the Quality Assurance Plan (QAP) shall be approved by
RMC. QAP for approval shall be submitted in 3 Original copy duly signed and stamped
by Manufacturer, Third Party Inspection Agency and Tenderer. The draft QAP format
has been attached herewith.
39. The Vendor Form provided in the tender document shall also have to be filled by the
contractor and submitted along with all other required documents during the physical
40. Any Finacial document i.e. FDR, Demand Draft etc. must be accompanied with the
details like; Name Address of Issuing Branch, Name and Address of Verifying Brach,
Name & Designation of Contact Person, Contact Number, e-mail address, Fax Number
41. Necessary certificate / approval from PGVCL or electrical department or any other
statutory authority may be required is to be obtained and submitted by contractor.
Necessary fees will be paid by Contractor and no refund will be given to contractor by
RMC, hence the charges for the same should be included in tender by contractor.
42. Inspection: RMC will depute the representative of technical person’s of Rajkot
Municipal Corporation & TPI for inspection at manufacturer site. After successful
inspection Contractor should inform RMC before dispatch of material. The bidder should
arrange for the inspection at his own cost.
43. Training: If Required RMC will depute the representative of technical person of Rajkot
Municipal Corporation for Training. The bidder should arrange for the Training.
44. The tender will be treated as no responsive if Tender in the name of firm or a person who
is not an approved manufacturer or Black Listed/Debar/ Terminated anywhere, in India
by any Govt. / Semi-Govt. Department.
45. Payment will be made in following sequence :
- 60% after supply of equipment at site in good condition.
- 20% after erection, testing and commissioning of DG set.
- 10% After One month of successful trial run
- 10% after submission of necessary NOC from concern Govt. Dept.
46. Penalty: for late completion of work, penalty will be imposed as per RMC rules.
47. Successful bidder shall have to enter in to an agreement as per RMC rules and will have
to pay Security Deposit @5% of contract value or tender amount which will be higher in
form of FDR or Bank Guaranty as per Gujarat Government Resolution No.:
EMD/10/2019/50/DMO, Date: 01/11/2019, in favor of RMC, with a period of not less
than 24 months.
48. Length of cable utilized will be measured and payment will be done on actual
measurement of cable utilized. Quantity of cables shown in price bid is approximately
and it is only for estimate purpose, but bidder must consider this quantity to quote the
49. Extension of Delay: If work is delayed by force majeure like act of God, Serious loss or
Damage by fire, Strike, Bandh, curfew, Rally, Heavy rain, flood, cyclone, earth quake or
any natural calamities occurs, or any other cause which is beyond the control of
contractor. In such case, Engineer in charges will decide sympathetically to waive
50. Municipal Commissioner, Rajkot Municipal Corporation, reserves the right to Accept or
reject any or all the tender(s) without assigning any reason thereof.
51. Technical Bid will be opened on the prescribed date and time (if possible) in c/o Add.
City Engineer (W.M.U.), Central Zone, near S.T. Stand, Rajkot Municipal Corporation,
52. Rajkot Municipal Corporation will deploy own engineers, who will inspect all the
material at factory anywhere in India and will also supervise erection, testing and
commissioning of the plant.
53. Every document, each page of tender and copy of commissioner’s order must be duly
54. All the drawings should be provided and Control Circuit Diagram of all panels should be
provided with Manuals (in soft copy & Hard copy both) and also take approval of TPI &
Rajkot Municipal Corporation.
55. If any necessary technical change required by competent authority or TPI in drawing,
tenderer will do that immediately and no any extra payment will be paid for the same.
56. For any legal matter only Rajkot jurisdiction will be considered.
57. If any necessary extra material or extra work will be need to done which is not including
in Tender/BOQ, then payment will be paid as per RMC/Government SOR. No tax or any
+ or – rate of tender apply for this.
58. Tenderer should visit site for augmentation work and take actual measurement for cable,
PDB before quote the tender.
Signature of Contractor
A.A.E.(ELE.) A.A.E.(ELE.) A.E.(C) D.E.E.(E) D.E.E.(C) A.C.E.
(WMU-E/Z) (Drainage) (Drainage) (Drainage) (Drainage) (W.M.U.)
Rajkot Municipal Corporation
Water Management Unit
NAME OF WORK:- SITC of Vaccum Circuit Breaker Panel with Allied Accessories and
Civil work at Various Location of Water management Unit. (Re-
(BOQ & RATES FOR EACH AS PER SCHEDULE-B,ATTACHED IN SEPARATE
Sr. No. Description & Location of work
A Raiya-1 ELECTRICAL WORK 1,24,23,432/-
B Bajrangwadi ELECTRICAL WORK
C SPS-2 Ghanteshvar ELECTRICAL WORK
D Bedi Water Filter Plant ELECTRICAL WORK
E Raiya-1 CIVIL WORK
F Bajrangwadi CIVIL WORK
Total Amount Without GST
Total Amount Without GST
I/We agree to carry out the above work at _ % (In
Fig) ( (In words) Equal/Above/Below the
estimated cost.
Contractor Shall Have To quote the rates in the given online Price Bid only.
Signature of Contractor:
A.A.E.(ELE.) A.A.E.(ELE.) A.E.(C) D.E.E.(E) D.E.E.(C) A.C.E.
(WMU-E/Z) (Drainage) (Drainage) (Drainage) (Drainage) (W.M.U.)
PAYMENT SCHEDULE
Schedule of Payment % Break-up of payment for each component of the Pumping Machinery
during Supply, Installation, Trial Run & Commissioning.
Sr. No. Break-Up Amount
1. After supply of equipment at site in good condition. 60%
2. After erection, testing and commissioning of VCB set. 20%
3. After One month of successful trial run 10%
4. After submission of necessary NOC from concern Govt. Dept. 10%
Note:- Trial Run period of 30 Days
Contractor’s Signature
RAJKOT MUNICIPAL CORPORATION
WATER MANAGENENT UNIT
Name of Work - SITC of Vaccum Circuit Breaker Panel with Allied Accessories and Civil work
at Various Location of Water management Unit.
Item Description Qty. Unit
A ELECTRICAL COSTING of Raiya-1 Drainage Pumping station
H.T. INDOOR SWITCH GEAR PANEL
SITC of 11 kV, 500 MVA, 630A, Indoor, Extensible type,
Horizontal draw out,
Motorised spring charging mechanism, 4 breaker Vaccum
Circuit Breaker Panel (1 Incomer + 3 outgoing), with EC
grade copper busbars along with required Resin cast CT Dual
primary & secondary, Cl: 0.5/5P10, 15VA, Digital MFM
with RS 485 with 3 Line Display, Class-0.5s and PT (dual
secondary) Cl:0.5/3P, min 200VA or higher for metering and
1.1 protection, 110V DC power pack for individual incoming and 1 Set
outgoing feeder, Annunciator, Hooter, Indicating lamps,
Numerical Protection relay (current & Voltage Based) with
RS 485 with combined protection for 3O/C+1E/F, S/C,
Under & Over Voltage, Tfr. Protection Aux. relay etc. High
speed tripping relay, Trip ckt supervision relay, Fuse failure
relay, Digital Power factor meter, Ammeter, Voltmeter (Only
I/C), A/M switch suitable for PLC/SCADA etc. complete in
all respects as per IS, tender Specification. (For Raiya-1).
Shifting of Existing working VCB panel. Including
disconnection of HT, LT connection, earthing connection,
and Removal work of existing HT cables etc. including
loading, shifting & unloading at new vcb room as directed by
Enng. in charge. including Re-installation, termination,
testing & commissioning of Existing working VCB. and all
necessary civil, mechanical, febrication work for supports
etc. works in scope of agency
SITC of 11 kV (UE), 3C x 240 sq.mm., Aluminium, extruded
innersheath, Armoured, XLPE , H.V Cable as per IS
1.3 (part 2) and Tech. Specification. 180 Mtr
(DP to VCB, VCB to Tr1 & 2,VCB to Tr1 & 2 of Raiya-2)
SITC of the Heat shrinkable type Outdoor H.T.cable end
1.4 terminations suitable for 11 kV, 3C x 240 sq.mm. XLPE 3 Nos
(UE) armoured cable.
SITC of the Heat shrinkable type Indoor H.T.cable end
1.5 terminations suitable for 11 kV, 3C x 240 sq.mm. XLPE 9 Nos
(UE) armoured cable.
Supply, laying, testing & commissioning and termination of
1.1 kV grade, XLPE insulated, stranded Aluminium
conductor, galvanised steel flat srip/ round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (The
cable when laid outside the building shall be laid
2.1 underground in excavated trench, as per specified 75 Mtr
method and shall be laid in prepared trench on cable tray
when laid inside the building.) conforming to IS 7098).
conductor cables as per tender specification & IS.
4C x 10 sq.mm. 2XWY Aluminium Cable (for power
supply of VCB room )
Supply, laying, testing & commissioning and termination of
1.1 kV grade, XLPE insulated, stranded Copper conductor,
galvanised steel flat srip/ round wire armoured, extruded
PVC type ST2 sheathed, heavy duty cable (The cable when
laid outside the building shall be laid underground in
2.2 excavated trench, as per specified method and shall be 80 Mtr.
laid in prepared trench on cable tray when laid inside the
building.) conforming to IS 7098). conductor cables as per
tender specification & IS.
3 C x 2.5 sq. mm. 2XWY Copper Cable (X'mer marshaling
box Single Phase Supply)
Supply, laying, testing & commissioning and termination
of 1.1 kV grade, XLPE insulated, stranded Copper
conductor, galvanised steel flat srip/ round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (The
cable when laid outside the building shall be laid
underground in excavated trench, as per specified
method and shall be laid in prepared trench on cable tray
when laid inside the building.) conforming to IS 7098).
conductor cables as per tender specification & IS.
12 C x 2.5 sq. mm. 2XWY Copper Cable (Tr. to HT
Panel, control cable)
Chemical, Bore type Earthing with 80 mm Dia., 3 mtr
3.1 Long, IS 3043-1947 Rated earth electrode & 50 kg. 4 Nos
Chemical bag. as per tender specification. (for two VCB)
Supply,laying and erection of 40mm x6mm size Copper
earthing Strip including supply & fixing of bolts, saddles
3.2 when laid inside the building. Copper Bolt, Nuts, Washers 150 kg
shall be used for Connecting Earth electrode
(40X6 Cu. Strip, 1.88 Kg/m, 1.88 x80mtr.=150Kg.)
Supply & laying 300(W) x 50(H) GI perforated type Cable
trays with returned edge / flange, fabricated from 2.0 mm thk
sheet steel in the standard length of 2.5 mtrs, duly hot
dipped galvanized after fabrication as per IS 2629-1989
4.1 / IS 4759-1984 including accessories such as coupler 20 Mtr
plates/fish plates, bends, tees, reducers, elbows, covers
and electro-galvanized hardware etc, erected on
existing support as per tender specification and
instruction of Engineer-in-charge.
Supply & laying 150(W) x 50(H) GI perforated type Cable
trays with returned edge / flange, fabricated from 2.0 mm thk
sheet steel in the standard length of 2.5 mtrs, duly hot
dipped galvanized after fabrication as per IS 2629-1989
4.2 / IS 4759-1984 including accessories such as coupler 20 Mtr
plates/fish plates, bends, tees, reducers, elbows, covers
and electro-galvanized hardware etc, erected on
existing support as per tender specification and
instruction of Engineer-in-charge.
Making Trench/excavation in soft soil of suitable width and
of depth (minimum 750mm depth (LT) & 1000mm for HT)
5.1 for laying cable/ DWC pipe and back filling the same and 50 Mtr
making the surface as normal ground as per IS &Tender
Specification. (For laying of HT/LT cable)
Cable Protection/ Covering in Trench: Cable Covering
with second class bricks or cement tiles laid cover the cable
(top) & also on both side with sand bedding/ cushioning of
5.2 75mm. & covering of 150mm Layer of sand above cable (16 50 Mtr
bricks per meter.) as per IS & Tender Specification. (For
HT/LT cable protection) complete in all respects as instructed
Supply, laying and erection of 120 mm OD approved
make Double Walled Corrugated pipes (DWC) of
polyethelene (confirming to IS-14930 II) with necessary
5.3 connecting accessories of same material at required depth for 50 Mtr
laying of cable below ground / road surface for enclosing
cable and back filling the same to make ground as per
3 Phase 4 Wire TPN, 6 way Pre-wired-MOG / Aux. PDB for
Auxiliary accessories ,Load power supply, VCB power
6.1 supply, WR-DB and Lighting etc 1 Nos
Incoming: 63A 4P, MCB 'C' Curve
Out going: 6nos. 32A 4P MCB 'C' Curve
SITC of Mains & outlet points wiring with 1.1 kV grade
FRLS PVC insulated ISI marked flexible stranded copper
conductor wires with medium class min. 25mm. dia.
Electrical grade Rigid PVC pipe and accessories to be erected
concealed in / to berun on surface / wall / ceiling with
following sizes as mentioned below. The unit rate wirings
6.2 shall be with connector, PVC junction box, wires, holder, 20 Mtr
ceilingrose, angle holder, switch, sockets, switch board, brass
chromium / cadmium plated machine screws, phase and
neutral wires, green Earth continuity wires etc. as required to
complete wiring from LDB panel to the final outlet
termination points.The wirings hall be as per IS:732, IS:4648
and as per tender specification / IS.
(a) SITC of Mains wiring with 3 wire 2.5 sq.mm.
SITC of Point wiring for Light / fan / Bell / Primary Point
with 2nos. 1.5 sq. mm& earth wire of 1.5 sq. mm (green)
both are of ISI marked 1.1 kv grade FRLS PVC insulated
multistrand copper wires, pipe to be erected concealed in
flushedon wall / ceiling, complete with 6A Tissino Type ISI
marked flush type switch/ bell push & accessories erected on
metal / PVC Box covered with 3 mm thick
PC(Polycarbonate) / Acrylic sheet with necessary lamp
holder / ceiling Rose / H. D. connector as directed with
medium class Rigid PVC pipe & accessories.
SITC of 16A independent Plug with 2nos. 2.5 sq.mm Cu.
Mains size wiring & earth wire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires with medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling, complete with ISI
marked 3 / 5 Pin socket and tissino type switch erected with
earth continuity connection erected on Metal / PVC box
covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet.
LED LIGHT FIXTURES & LIGHTING:
SITC of Indoor wall mounting 20Watt or up to 25% higher
wattage LED 4 feet Tube Light indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of
thick sheet Steel conforming to IS: 513/CRCA polyester
powder coated and high U.V. & corrosion resistance with
diffuserand/ or Polycarbonate optics with company
120 to 300V, Power Factor more than 0.9, THD<20%, CCT
4000 K to 6500K, Uniformity ratio >0.7, Luminaries
efficacy >85 lumens/ watt,
LED driver efficiency >85%
(Each fitting required LM-79 & LM-80 Certificates)
Tube Light with integral/ non-integral driver, Surge-4KV, IP-
20, 4feet, Cat-III.
SITC of 40W LED Surface / Wall mounted LED Flood
Light fittings with High power White LEDs wattage of
1Watt and above assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
7.2 Polycarbonate optics/ lenses with company mark/name 4 Nos
engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 20 %,
CCT 5000 K to 5700K, Uniformity ratio >0.45, Luminaries
efficacy> 85 lumens/watt . LED driver efficiency > 85 %.
(Each fittings required LM-79 & LM-80 certificates), (IP-
65), Surge -4KV Cat-III. (For ground lighting)
Supply and laying of Synthetic Insulating Mat of Class - B
of min. thickness 4 mm as per IS:15652 and with good Sq.
electrical insulation property for 11kV/22KV as per site Mtr
requirement. (For HT Panel)
LIASONING CHARGES FOR OBTAINING NOC
Liasoning Charges for obtaining N.O.C from Electrical
Inspector / Statutory authority for Power / Ele. Installation.
(Fees shall be paid by tenderer for obtaining N.O.C. from
Electrical Inspector / Statutory authority on behalf of client
and shall be reimbursed on submission of original receipt to
Client). And also raising contract demand of PGVCL
Connection as directed by Enng. in charge.
Liasoning Charges shall include preparing required attested
documents & drawing for obtaining NOC on behalf of client
(Applicable Fees / deposits shall be reimbursed by Client).
ELECTRICAL COSTING of Bajrangwadi Drainage Pumping
H.T. INDOOR SWITCH GEAR PANEL
SITC of 11 kV, 500 MVA, 630A, Indoor, Extensible type,
Horizontal draw out,
Motorised spring charging mechanism, 3 breaker Vaccum
Circuit Breaker Panel (1 No. Incomer + 2 Nos. outgoing),
with EC grade copper busbars along with required Resin cast
CT Dual primary & secondary, Cl: 0.5/5P10, 15VA, Digital
MFM with RS 485 with 3 Line Display, Class-0.5s and PT
(dual secondary) Cl:0.5/3P, min 200VA or higher for
1.1 metering and protection, 110V DC power pack for individual 1 Set
incoming and outgoing feeder, Annunciator, Hooter,
Indicating lamps, Numerical Protection relay (current &
Voltage Based) with RS 485 with combined protection for
3O/C+1E/F, S/C, Under & Over Voltage, Tfr. Protection
Aux. relay etc. High speed tripping relay, Trip ckt
supervision relay, Fuse failure relay, Digital Power factor
meter, Ammeter, Voltmeter (Only I/C), A/M switch suitable
for PLC/SCADA etc. complete in all respects as per IS,
tender Specification.
SITC of 11 kV (UE), 3C x 240 sq.mm., Aluminium, extruded
1.2 innersheath, Armoured, XLPE , H.V Cable as per IS 7098 90 Mtr
(part 2) and Tech. Specification. (DP to VCB, VCB to Tr1
SITC of the Heat shrinkable type Outdoor H.T.cable end
1.3 terminations suitable for 11 kV, 3C x 240 sq.mm. XLPE 1 Nos
(UE) armoured cable.
SITC of the Heat shrinkable type Indoor H.T.cable end
1.4 terminations suitable for 11 kV, 3C x 240 sq.mm. XLPE 5 Nos
(UE) armoured cable.
Supply, laying, testing & commissioning and termination of
1.1 kV grade, XLPE insulated, stranded Aluminium
conductor, galvanised steel flat srip/ round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (The
cable when laid outside the building shall be laid
2.1 underground in excavated trench, as per specified 120 Mtr
method and shall be laid in prepared trench on cable tray
when laid inside the building.) conforming to IS 7098).
conductor cables as per tender specification & IS.
4C x 10 sq.mm. 2XWY Aluminium Cable (for power
supply of VCB room )
Supply, laying, testing & commissioning and termination of
1.1 kV grade, XLPE insulated, stranded Copper conductor,
galvanised steel flat srip/ round wire armoured, extruded
PVC type ST2 sheathed, heavy duty cable (The cable when
laid outside the building shall be laid underground in
2.2 excavated trench, as per specified method and shall be 50 Mtr.
laid in prepared trench on cable tray when laid inside the
building.) conforming to IS 7098). conductor cables as per
tender specification & IS.
3 C x 2.5 sq. mm. 2XWY Copper Cable (X'mer marshaling
box Single Phase Supply)
Supply, laying, testing & commissioning and termination
of 1.1 kV grade, XLPE insulated, stranded Copper
conductor, galvanised steel flat srip/ round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (The
cable when laid outside the building shall be laid
2.3 underground in excavated trench, as per specified 50 Mtr.
method and shall be laid in prepared trench on cable tray
when laid inside the building.) conforming to IS 7098).
conductor cables as per tender specification & IS.
12 C x 2.5 sq. mm. 2XWY Copper Cable (Tr. to HT
Panel, control cable)
Chemical, Bore type Earthing with 80 mm Dia., 3 mtr
3.1 Long, IS 3043-1947 Rated earth electrode & 50 kg. 2 Nos
Chemical bag. as per tender specification. (for VCB)
Supply,laying and erection of 40mm x6mm size Copper
earthing Strip including supply & fixing of bolts, saddles
3.2 when laid inside the building. Copper Bolt, Nuts, Washers 30 kg
shall be used for Connecting Earth electrode
(40X6 Cu. Strip, 1.88 Kg/m)
Supply & laying 300(W) x 50(H) GI perforated type Cable
trays with returned edge / flange, fabricated from 2.0 mm thk
sheet steel in the standard length of 2.5 mtrs, duly hot
dipped galvanized after fabrication as per IS 2629-1989
4.1 / IS 4759-1984 including accessories such as coupler 10 Mtr
plates/fish plates, bends, tees, reducers, elbows, covers
and electro-galvanized hardware etc, erected on
existing support as per tender specification and
instruction of Engineer-in-charge.
Supply & laying 150(W) x 50(H) GI perforated type Cable
trays with returned edge / flange, fabricated from 2.0 mm thk
sheet steel in the standard length of 2.5 mtrs, duly hot
dipped galvanized after fabrication as per IS 2629-1989
4.2 / IS 4759-1984 including accessories such as coupler 10 Mtr
plates/fish plates, bends, tees, reducers, elbows, covers
and electro-galvanized hardware etc, erected on
existing support as per tender specification and
instruction of Engineer-in-charge.
Making Trench/excavation in soft soil of suitable width and
of depth (minimum 750mm depth (LT) & 1000mm for HT)
5.1 for laying cable/ DWC pipe and back filling the same and 30 Mtr
making the surface as normal ground as per IS &Tender
Specification. (For laying of HT/LT cable)
Cable Protection/ Covering in Trench: Cable Covering
with second class bricks or cement tiles laid cover the cable
(top) & also on both side with sand bedding/ cushioning of
5.2 75mm. & covering of 150mm Layer of sand above cable (16 30 Mtr
bricks per meter.) as per IS & Tender Specification. (For
HT/LT cable protection) complete in all respects as instructed
Supply, laying and erection of 120 mm OD approved
make Double Walled Corrugated pipes (DWC) of
polyethelene (confirming to IS-14930 II) with necessary
5.3 connecting accessories of same material at required depth for 30 Mtr
laying of cable below ground / road surface for enclosing
cable and back filling the same to make ground as per
3 Phase 4 Wire TPN, 6 way Pre-wired-MOG / Aux. PDB for
Auxiliary accessories ,Load power supply, VCB power
6.1 supply, WR-DB and Lighting etc 1 Nos
Incoming: 63A 4P, MCB 'C' Curve
Out going: 6nos. 32A 4P MCB 'C' Curve
SITC of Mains & outlet points wiring with 1.1 kV grade
FRLS PVC insulated ISI marked flexible stranded copper
conductor wires with medium class min. 25mm. dia.
Electrical grade PVC pipe and accessories to be erected
concealed in / to berun on surface / wall / ceiling with
following sizes as mentioned below. The unit rate wirings
6.2 shall be with connector, PVC junction box, wires, holder, 20 Mtr
ceilingrose, angle holder, switch, sockets, switch board, brass
chromium / cadmium plated machine screws, phase and
neutral wires, green Earth continuity wires etc. as required to
complete wiring from LDB panel to the final outlet
termination points.The wirings hall be as per IS:732, IS:4648
and as per tender specification / IS.
(a) SITC of Mains wiring with 3 wire 2.5 sq.mm.
SITC of Point wiring for Light / fan / Bell / Primary Point
with 2nos. 1.5 sq. mm& earth wire of 1.5 sq. mm (green)
both are of ISI marked 1.1 kv grade FRLS PVC insulated
multistrand copper wires, pipe to be erected concealed in
flushedon wall / ceiling, complete with 6A Tissino Type ISI
marked flush type switch/ bell push & accessories erected on
metal / PVC Box covered with 3 mm thick
PC(Polycarbonate) / Acrylic sheet with necessary lamp
holder / ceiling Rose / H. D. connector as directed with
medium class Rigid PVC pipe & accessories.
SITC of 16A independent Plug with 2nos. 2.5 sq.mm Cu.
Mains size wiring & earth wire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires with medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling, complete with ISI
marked 3 / 5 Pin socket and tissino type switch erected with
earth continuity connection erected on Metal / PVC box
covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet.
LED LIGHT FIXTURES & LIGHTING:
SITC of Indoor wall mounting 20Watt or up to 25% higher
wattage LED 4 feet Tube Light indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of
thick sheet Steel conforming to IS: 513/CRCA polyester
powder coated and high U.V. & corrosion resistance with
diffuserand/ or Polycarbonate optics with company
120 to 300V, Power Factor more than 0.9, THD<20%, CCT
4000 K to 6500K, Uniformity ratio >0.7, Luminaries
efficacy >85 lumens/ watt,
LED driver efficiency >85%
(Each fitting required LM-79 & LM-80 Certificates)
Tube Light with integral/ non-integral driver, Surge-4KV, IP-
20, 4feet, Cat-III.
SITC of 40W LED Surface / Wall mounted LED Flood
Light fittings with High power White LEDs wattage of
1Watt and above assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
7.2 Polycarbonate optics/ lenses with company mark/name 1 Nos
engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 20 %,
CCT 5000 K to 5700K, Uniformity ratio >0.45, Luminaries
efficacy> 85 lumens/watt . LED driver efficiency > 85 %.
(Each fittings required LM-79 & LM-80 certificates), (IP-
65), Surge -4KV Cat-III. (For ground lighting)
Supply and laying of Synthetic Insulating Mat of Class - B
of min. thickness 4 mm as per IS:15652 and with good Sq.
electrical insulation property for 11kV/22KV as per site Mtr
requirement. (For HT Panel)
Dismantaling of Existing working DP structure (Nos-2), and
Removing existing HT Cable etc. including loading, shifting
& unloading at location as directed by Enng. in charge of
LIASONING CHARGES FOR OBTAINING NOC
Power Liasoning Charges for obtaining N.O.C from
Electrical Inspector / Statutory authority for Power / Ele.
Installation. (Fees shall be paid by tenderer for obtaining
N.O.C. from Electrical Inspector / Statutory authority on
9.1 behalf of client and shall be reimbursed on submission of 1 Ls.
original receipt to Client). And also raising contract demand
of PGVCL Connection as directed by Enng. in charge.
Liasoning Charges shall include preparing required attested
documents & drawing for obtaining NOC on behalf of client
(Applicable Fees / deposits shall be reimbursed by Client).
ELECTRICAL COSTING of SPS-2 Ghanteshvar Drainage
Pumping station / 15 MLD STP
H.T. INDOOR SWITCH GEAR PANEL
SITC of 11 kV, 500 MVA, 630A, Indoor, Extensible type,
Horizontal draw out,
Motorised spring charging mechanism, 4 breaker Vaccum
Circuit Breaker Panel (1 Incomer + 3 outgoing)or(1
Incomer + 2 outgoing and 1 outgoing for existing VCB),
with EC grade copper busbars along with required Resin cast
CT Dual primary & secondary, Cl: 0.5/5P10, 15VA, Digital
MFM with RS 485 with 3 Line Display, Class-0.5s and PT
(dual secondary) Cl:0.5/3P, min 200VA or higher for
metering and protection, 110V DC power pack for individual
incoming and outgoing feeder, Annunciator, Hooter,
Indicating lamps, Numerical Protection relay (current &
Voltage Based) with RS 485 with combined protection for
3O/C+1E/F, S/C, Under & Over Voltage, Tfr. Protection
Aux. relay etc. High speed tripping relay, Trip ckt
supervision relay, Fuse failure relay, Digital Power factor
meter, Ammeter, Voltmeter (Only I/C), A/M switch suitable
for PLC/SCADA etc. complete in all respects as per IS,
tender Specification.
Note :- (1 outgoing breaker should be match with the
Shifting of Existing working VCB panel. Including
disconnection of HT, LT connection, earthing connection,
and Removal work of existing HT cables etc. including
loading, shifting & unloading at new vcb room as directed by
Enng. in charge. including Re-installation, termination,
testing & commissioning of Existing working VCB. and all
necessary civil, mechanical, febrication work for supports
etc. works in scope of agency
SITC of 11 kV (UE), 3C x 240 sq.mm., Aluminium, extruded
1.2 innersheath, Armoured, XLPE , H.V Cable as per IS 7098 25 Mtr
(part 2) and Tech. Specification.
(DP to VCB, VCB to Tr1 & 2)
SITC of the Heat shrinkable type Outdoor H.T.cable end
1.3 terminations suitable for 11 kV, 3C x 240 sq.mm. XLPE 1 Nos
(UE) armoured cable.
SITC of the Heat shrinkable type Indoor H.T.cable end
1.4 terminations suitable for 11 kV, 3C x 240 sq.mm. XLPE 5 Nos
(UE) armoured cable.
Supply, laying, testing & commissioning and termination of
1.1 kV grade, XLPE insulated, stranded Aluminium
conductor, galvanised steel flat srip/ round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (The
cable when laid outside the building shall be laid
2.1 underground in excavated trench, as per specified 0 Mtr
method and shall be laid in prepared trench on cable tray
when laid inside the building.) conforming to IS 7098).
conductor cables as per tender specification & IS.
4C x 10 sq.mm. 2XWY Aluminium Cable (for power
supply of VCB room )
Supply, laying, testing & commissioning and termination of
1.1 kV grade, XLPE insulated, stranded Copper conductor,
galvanised steel flat srip/ round wire armoured, extruded
PVC type ST2 sheathed, heavy duty cable (The cable when
laid outside the building shall be laid underground in
2.2 excavated trench, as per specified method and shall be 15 Mtr.
laid in prepared trench on cable tray when laid inside the
building.) conforming to IS 7098). conductor cables as per
tender specification & IS.
3 C x 2.5 sq. mm. 2XWY Copper Cable (X'mer marshaling
box Single Phase Supply)
Supply, laying, testing & commissioning and termination
of 1.1 kV grade, XLPE insulated, stranded Copper
conductor, galvanised steel flat srip/ round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (The
cable when laid outside the building shall be laid
2.3 underground in excavated trench, as per specified 15 Mtr.
method and shall be laid in prepared trench on cable tray
when laid inside the building.) conforming to IS 7098).
conductor cables as per tender specification & IS.
12 C x 2.5 sq. mm. 2XWY Copper Cable (Tr. to HT
Panel, control cable)
Chemical, Bore type Earthing with 80 mm Dia., 3 mtr
3.1 Long, IS 3043-1947 Rated earth electrode & 50 kg. 2 Nos
Chemical bag. as per tender specification. (for VCB)
Supply,laying and erection of 40mm x6mm size Copper
earthing Strip including supply & fixing of bolts, saddles
3.2 when laid inside the building. Copper Bolt, Nuts, Washers 30 kg
shall be used for Connecting Earth electrode
(40X6 Cu. Strip, 1.88 Kg/m)
Making Trench/excavation in soft soil of suitable width and
of depth (minimum 750mm depth (LT) & 1000mm for HT)
4.1 for laying cable/ DWC pipe and back filling the same and 15 Mtr
making the surface as normal ground as per IS &Tender
Specification. (For laying of HT/LT cable)
Cable Protection/ Covering in Trench: Cable Covering
with second class bricks or cement tiles laid cover the cable
(top) & also on both side with sand bedding/ cushioning of
75mm. & covering of 150mm Layer of sand above cable (16
bricks per meter.) as per IS & Tender Specification. (For
HT/LT cable protection) complete in all respects as instructed
Supply, laying and erection of 120 mm OD approved
make Double Walled Corrugated pipes (DWC) of
polyethelene (confirming to IS-14930 II) with necessary
4.3 connecting accessories of same material at required depth for 15 Mtr
laying of cable below ground / road surface for enclosing
cable and back filling the same to make ground as per
Supply and laying of Synthetic Insulating Mat of Class - B
of min. thickness 4 mm as per IS:15652 and with good Sq.
electrical insulation property for 11kV/22KV as per site Mtr
requirement. (For HT Panel)
LIASONING CHARGES FOR OBTAINING NOC
Power Liasoning Charges for obtaining N.O.C from
Electrical Inspector / Statutory authority for Power / Ele.
Installation. (Fees shall be paid by tenderer for obtaining
N.O.C. from Electrical Inspector / Statutory authority on
6.1 behalf of client and shall 1 Ls.
be reimbursed on submission of original receipt to Client).
Liasoning Charges shall include preparing required attested
documents & drawing for obtaining NOC on behalf of client
(Applicable Fees / deposits shall be reimbursed by Client).
D ELECTRICAL COSTING of BEDI WATER FILTER PLANT
H.T. INDOOR SWITCH GEAR PANEL (800 AMP VCB)
Supply, installation, testing & commissioning both side
extensible, Indoor type HV Switchgear panel confirming to
lattest IS- for use on 3phase, 50 Hz, unearthed AC supply
system and having breaking/ ruptuing capacity of 500 MVA
(26.3 kA for 3sec) complete with spring charged mechanism,
ON-OFF mechanical push button, operation counters,Breaker
TNC switch, Breaker L/R switch, necessary auxiliary
switches, closing coil, shunt trip, protection relays &
Indicators etc.,complete.
The panel shall comprise of air insulated busbars provided
with heat shrinkable PVC sleeves. The VCB trolley shall
comprise of three Vaccum interrupters with epoxy support
insulators and self aligning finger type isolating contacts and
necessary mechanical interlocks, safety shutters, isolating
plugs. Enclosure shall be openable from front as well as rear
The breaker shall be Manual cum motorised mechanism with
following accessories.
a) 96 x 96 mm square flush mounting type Ammeter & Volt
meter with selector switches
b) Multi function meter
c) Double core, cast resin type current transofrmer having
ratio as per requirement, one core for metering & one core for
protection having required class of accuracy.
d) Instantaneous under voltage relay & Temperature rise
tripping Relay,
e) Triple pole IDMTL two over current and one earth fault
relay with current setting range 50-200% and 10-40%
f) Electrical closing. coil & shunt trip coil operating on 110 V
g) Auxiliary relay for anti pumping device.
h) Three limb, drawout type, feeder connected, cast resin
insulated, three phase Potential transformer having ratio &
burden as per reqirement & Class 0.5 accuracy.
i) Annunciator Windows, Common Hooter / Alarm bell
operating on 230 AC/ 110 V DC.
j) Cable boxes suitable to terminate 3 core XLPE cable of
required size (As per design).
k) 230V AC to 110 V DC power pack for closing & tripping
circuit common.
l) Breaker ON-OFF, Auto trip and spring charged indicators.
m) Phase indicating & panel illumination lamps with plug
n) Space Heater with Thermostat. 11 kV HV
Switchgear Panel- Comprising of 800 A Vaccum circuit
breaker for 1no. Incomer, 2no. O / G feeders for 11/0.433kV
distribution transformers
Dismantaling of Existing working VCB panel including,
removing termination from existing Panels, etc including
loading, shifting & unloading at location as directed by Enng.
in charge of RMC.Necessary civil, Mechanical works like
1.2 expanding of cable trench, febrication work for supports etc 1 Lot
all other works in scope of agency
LIASONING CHARGES FOR OBTAINING NOC
Power Liasoning Charges for obtaining N.O.C from
Electrical Inspector / Statutory authority for Power / Ele.
Installation. (Fees shall be paid by tenderer for obtaining
N.O.C. from Electrical Inspector / Statutory authority on
behalf of client and shall be reimbursed on submission of
original receipt to Client). Liasoning Charges shall include
preparing required attested documents & drawing for
obtaining NOC on behalf of client (Applicable Fees /
deposits shall be reimbursed by Client).
(E) CIVIL WORKS COSTING OF RAIYA – 1 DRAINAGE PUMPING STATION
No. QTY. Item Rate Unit
Excavation of Foundation in Soft/Hard Murrum, Soil or Sand
from 0.0 mtr. to 1.50 mtr depth including dewatering with lifting
1 115.00 and laying in RMC limit as instructed 137.00 Cu. Mt.
Excavation of Foundation in Hard Murrum from 1.51 mtr. to
2 35.00 mtr depth including dewatering with lifting and laying in RMC 159.00 Cu. Mt.
limit as instructed
Excavation of Foundation in Soft Rock/Hard Rock from 1.51 mtr.
to 3.0 mtr depth including dewatering with lifting and laying in
3 70.00 RMC limit as instructed 534.00 Cu. Mt.
Foundation filling with CC work in proportion of 1:2:4 using
4 11.00 cm to 2.0 cm aggregate including Raming, Curing etc. 4626.00 Cu. Mt.
CC work M-30 for RCC footing using aggregate of size 10-20 mm,
5 20.00 centring, curing, finishing etc. complete (without reinforcement) 5830.00 Cu. Mt.
CC work M-30 for Column using aggregate of size 10-20 mm,
6 20.00 centring, curing, finishing etc. complete (without reinforcement) 6750.00 Cu. Mt.
Brick Masonry work in Cement:Mortar 1:6
CC work M-30 for Beam using aggregate of size 10-20 mm,
8 15.00 centring, curing, finishing etc. complete (without reinforcement) 6450.00 Cu. Mt.
Filling of Plinth with using excavated usefull material partly and
remaining murrum to be brought from out side in layer of
9 110.00 m thick including murrum and sprinkling of water, compaction 185.00 Cu. Mt.
Supplying, Cutting, Beding, Binding and Hooking and binding
10 11400.00 wire for RCC work Tor steel TMT round bar including all cost 65.00 Kg.
CC work M30 for RCC slab using aggregate of size 10-20 mm,
11 32.00 centring, curing, finishing etc. complete (without reinforcement) 6500.00 Cu. Mt.
CC work M-25 for Chhajja using aggregate of size 10-20 mm,
12 1.00 centring, curing, finishing etc. complete (without reinforcement) 5950.00 Cu. Mt.
CC work M-25 for Lintel using aggregate of size 10-20 mm,
centring, curing, finishing etc. complete (without reinforcement)
CC work 1:2:4 for RCC slab using aggregate of size 10-20 mm,
14 8.00 centring, curing, finishing etc. complete (without reinforcement) 5535.00 Cu. Mt.
Cement Plaster 12 mm thick using Cement:Mortar in proportion
with Niru Finishing curing, etc. Complete
20mm thick Sand Face Cement Plaster Work in which 1 paster in
proportion of 1:3 and 2nd plaster inteh proportion of 1:2 using
16 300.00 Cement:Mortar with spong finishing etc. complete 263.00 Sq. Mt.
Supply & Fixing of Broken Glazed (China Mosaic) tiles size 5-6
mm thick of different size and shade (approved crazy patern) in
17 80.00 Cement:Mortar 1:2 and joint filling with White Cement / 306.00 Sq. Mt.
Coloured Cement including Ramping, Watering, Curing etc.
Plastic Imulsion Paint (Two coats) (Asian Paint, ICI, Dulux,
18 290.00 Nerolac, Berger etc. of approved type) (with Prime Coat) 145.00 Sq. Mt.
Apex Color work on Outer side of Wall (Two coats) (with Base
Cement Concrete flooring (IPS) 50 mm thick in proportion of
20 20.00 with a floating coat of neat cement, finishing, curing etc. 338.00 Sq. Mt.
Supply, Fixing & Polishing of Kota Stone work thickness 20-25
mm to be fixed in Lime:Mortar 1:2 and liquid Cement and as
21 80.00 instructed 913.00 Sq. Mt.
Providing & fixing approved quality & designed rolling shutters
with necessary top cover, fittings, single coat red lead, double
silver or oil paint (with bearing)
Enemal painting on door/window, iron door, iron grill or
23 70.00 woodwork 125.00 Sq. Mt.
Iron work as per drawing and instruction including all
Cement, lodhiya work with neat cement slurry finishing.
Rigid P.V.C. Pipe ISI Marked of 6 kg/sq.cm. Pressure, required
26 50.00 with coupler, only supplies work.for pipe of 110 m.m.outer dia. 250.00 Rmt.
Rigid PVC Pipe 4 to 6 kg/sq.cm pressure. With the necessary
fittings of it. The required solvent to be joined with cement.
27 50.00 (Only labour work).for pipe of 110 m.m. outer dia. 12.00 Rmt.
Foundation filling with Rubble Cement Mortar in proportion of
Rubble Plinth massonary work in Cement:Mortar in proportion
29 9.00 1:6 with Brick Massonary Or Rubble Corner and in 1425.00 Cu. Mt.
propoproportion of 1:3 without C.Pointing
30 3.00 Providing & fixing FRP door. 4200.00 Sq. Mt.
Removal of Excavated Stuff and laying within RMC limit as
31 110.00 directed by Engineer-in-Charge 171.00 Cu. Mt.
CC work M-25 for Partition, Parsdment, railling etc.using
aggregate of size 10-20 mm, centring, curing, finishing etc.
32 6.00 complete (without 7150.00 Cu. Mt.
aluminium section window work (with 3 track mosquito net )
33 14.00 (jindal)(with necessary all fittings) 7061.00 Sq.mt
(F) CIVIL WORKS COSTING OF BAJARANGWADI DRAINAGE PUMPING STATION
No. QTY. Item Rate Unit
Excavation of Foundation in Soft/Hard Murrum, Soil or Sand
from 0.0 mtr. to 1.50 mtr depth including dewatering with lifting
1 100.00 and laying in RMC limit as instructed 137.00 Cu. Mt.
Excavation of Foundation in Hard Murrum from 1.51 mtr. to
2 30.00 mtr depth including dewatering with lifting and laying in RMC 159.00 Cu. Mt.
limit as instructed
Excavation of Foundation in Soft Rock/Hard Rock from 1.51 mtr.
to 3.0 mtr depth including dewatering with lifting and laying in
3 60.00 RMC limit as instructed 534.00 Cu. Mt.
Foundation filling with CC work in proportion of 1:2:4 using
cm to 2.0 cm aggregate including Raming, Curing etc.
CC work M-30 for RCC footing using aggregate of size 10-20 mm,
5 20.00 centring, curing, finishing etc. complete (without reinforcement) 5830.00 Cu. Mt.
CC work M-30 for Column using aggregate of size 10-20 mm,
6 16.00 centring, curing, finishing etc. complete (without reinforcement) 6750.00 Cu. Mt.
Brick Masonry work in Cement:Mortar 1:6
CC work M-30 for Beam using aggregate of size 10-20 mm,
8 10.00 centring, curing, finishing etc. complete (without reinforcement) 6450.00 Cu. Mt.
Filling of Plinth with using excavated usefull material partly and
remaining murrum to be brought from out side in layer of
9 70.00 m thick including murrum and sprinkling of water, compaction 185.00 Cu. Mt.
Supplying, Cutting, Beding, Binding and Hooking and binding
10 11000.00 wire for RCC work Tor steel TMT round bar including all cost 65.00 Kg.
CC work M30 for RCC slab using aggregate of size 10-20 mm,
11 28.00 centring, curing, finishing etc. complete (without reinforcement) 6500.00 Cu. Mt.
CC work M-25 for Chhajja using aggregate of size 10-20 mm,
12 2.00 centring, curing, finishing etc. complete (without reinforcement) 5950.00 Cu. Mt.
CC work M-25 for Lintel using aggregate of size 10-20 mm,
13 5.00 centring, curing, finishing etc. complete (without reinforcement) 6000.00 Cu. Mt.
CC work 1:2:4 for RCC slab using aggregate of size 10-20 mm,
14 5.00 centring, curing, finishing etc. complete (without reinforcement) 5535.00 Cu. Mt.
Cement Plaster 12 mm thick using Cement:Mortar in proportion
with Niru Finishing curing, etc. Complete
20mm thick Sand Face Cement Plaster Work in which 1 paster in
proportion of 1:3 and 2nd plaster inteh proportion of 1:2 using
Cement:Mortar with spong finishing etc. complete
Supply & Fixing of Broken Glazed (China Mosaic) tiles size 5-6
mm thick of different size and shade (approved crazy patern) in
17 60.00 Cement:Mortar 1:2 and joint filling with White Cement / 306.00 Sq. Mt.
Coloured Cement including Ramping, Watering, Curing etc.
Plastic Imulsion Paint (Two coats) (Asian Paint, ICI, Dulux,
18 230.00 Nerolac, Berger etc. of approved type) (with Prime Coat) 145.00 Sq. Mt.
Apex Color work on Outer side of Wall (Two coats) (with Base
Cement Concrete flooring (IPS) 50 mm thick in proportion of
20 20.00 with a floating coat of neat cement, finishing, curing etc. 338.00 Sq. Mt.
Supply, Fixing & Polishing of Kota Stone work thickness 20-25
mm to be fixed in Lime:Mortar 1:2 and liquid Cement and as
21 50.00 instructed 913.00 Sq. Mt.
Providing & fixing approved quality & designed rolling shutters
with necessary top cover, fittings, single coat red lead, double
22 15.00 coat silver or oil paint (with bearing) 2376.00 Sq. Mt.
Enemal painting on door/window, iron door, iron grill or
23 30.00 woodwork two coat 125.00 Sq. Mt.
Iron work as per drawing and instruction including all
Cement, lodhiya work with neat cement slurry finishing.
Rigid P.V.C. Pipe ISI Marked of 6 kg/sq.cm. Pressure, required
26 50.00 with coupler, only supplies work.for pipe of 110 m.m.outer dia. 250.00 Rmt.
Rigid PVC Pipe 4 to 6 kg/sq.cm pressure. With the necessary
fittings of it. The required solvent to be joined with cement.
27 50.00 (Only labour work).for pipe of 110 m.m. outer dia. 12.00 Rmt.
Foundation filling with Rubble Cement Mortar in proportion of
28 20.00 1:6 Cement:Mortar 1667.00 Cu. Mt.
Rubble Plinth massonary work in Cement:Mortar in proportion
29 7.00 1:6 with Brick Massonary Or Rubble Corner and in 1425.00 Cu. Mt.
propoproportion of 1:3 without C.Pointing
30 6.00 Providing & fixing FRP door. 4200.00 Sq. Mt.
Removal of Excavated Stuff and laying within RMC limit as
31 100.00 directed by Engineer-in-Charge 171.00 Cu. Mt.
CC work M-25 for Partition, Parsdment, railling etc.using
aggregate of size 10-20 mm, centring, curing, finishing etc.
32 4.00 complete (without 7150.00 Cu. Mt.
Dismantelling of Super Structure and dispossing it in RMC area
Supply & Fixing of Glazed tiles (1st Quality) of required size in
Cement Roga and joints to be filled with white cement after
34 4.00 12mm rough plaster in proportion of 1:3 493.00 Sq. Mt.
Supply & fixing of Vitrified flooring work (1st quality)
Indian type white porselin w/c. 580mm size 14lt. flushing tank,
36 1.00 pipe, p trape with supply and fixing 3245.00 No.
White porselin wash bassin 510/410mm indian make c.i. bracket
with fitting cromium platted topes 25cm plastic waste pipe and
37 1.00 12mm pillar cock with comp. 1261.00 No.
38 1.00 Supply & Fixing of CC Pre-Cast Jali 983.00 Sq. Mt.
uPVC pipes of Shedule-40 of any standard approved brand &
39 5.00 quality. For 20 mm Ø. (2.87 mm min. wall thickness) 48.00 R. Mt.
Laying of PVC / UPVC Pipe line - 15 to 75 mm dia without special
as per site condition with required jointing solution including
40 5.00 hydraulic testing as directed by engineer-in-charge 6.00 R. Mt.
Brass wheel valve 20mm dia. fitting with fixxing.
Tusted brass cock, stop cock etc. 20mm dia fitting with fixing.
Nahni trape 7.6cm of PVC fitting and fixing
aluminium section window work (with 3 track mosquito net
44 14.00 )(jindal)(with necessary all fittings) 7061.00 Sq. Mt.
Rates are to be quoted online only.
Rates quoted in any other format will not be acceptable.
Bidder quoted rate including all Tax, Transportation, loading, unloading,
dismantling of existing buyback machineries etc. (Excluding GST)
A.A.E.(ELE.) A.A.E.(ELE.) A.E.(C) D.E.E.(E) D.E.E.(C) A.C.E.
(WMU-E/Z) (Drainage) (Drainage) (Drainage) (Drainage) (W.M.U.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Vol 1 General Terms and Conditions.pdf
Tender Vol 2 Technical Bid (Electrical).pdf
Tender Vol 3 Technical Bid - Civil.pdf
Tender Vol 4 Price Bid.pdf
Tender Notice.pdf
Download all tender documents and submit your bid