Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC CHAKKITTAPARA KOZHIKODE DISTRICT KOYILANDI TALUK KERALA | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.7 L+₹1.0 L (3.62%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹30.3 L
EMD Value
₹50,000
Closing Date
22 Dec 2022, 6:00 pmClosed
Assistant Engineer
Assistant Engineer LID EW Section Panangad 673612
Annual Plan-Project No 168/22-Thalayad Colony Drinking water Supply Scheme-General Civil Work
2022_LSGD_539631_1
AE/LSGD/PNGD/14/2022-23
Open Tender
Civil Works - Water Works
Item Rate
240 days
panangad
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
27 Jan 2023
15 Dec 2022
24 Dec 2022
15 Dec 2022
22 Dec 2022
15 Dec 2022
Amount
pipe line
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
OD245330/2022-2023:Excavation trenches of required width for pipes,cables,etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc.and disposing of surplus excavated soil as directed, within a lead of 50m: All kinds of soil (Modified 2.10.1.1)
OD250682/2022-2023:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, excluding trenching &refilling, including testing of joints complete as per direction of Engineer in Charge. 75 mm dia 10 Kgf/ cm2 (Modified 50.18.9.8.1
OD245349/2022-2023:Providing and fixing 80 mm - 80 Schedule UPVC-ASTM pipe including jointing of pipes with accessories and testing of joints complete as per direction of Engineer in charge
OD245356/2022-2023:Providing and fixing 65 mm - 40 Schedule UPVC-ASTM pipe including jointing of pipes with accessories and testing of joints complete as per direction of Engineer in charge
OD250645/2022-2023:Providing and fixing 50 mm - 40 Schedule UPVC-ASTM pipe including jointing of pipes with accessories and testing of joints complete as per direction of Engineer in charge
OD250643/2022-2023:Providing and fixing 40 mm - 40 Schedule UPVC-ASTM pipe including jointing of pipes with accessories and testing of joints complete as per direction of Engineer in charge
OD250644/2022-2023: Providing and fixing 25 mm (1'') - 40 Schedule UPVC-ASTM pipe including jointing of pipes with accessories and testing of joints complete as per direction of Engineer in charge
OD250642/2022-2023:Providing and fixing 20 mm - 40 Schedule UPVC-ASTM pipe including jointing of pipes with accessories and testing of joints complete as per direction of Engineer in charge
OD250663/2022-2023:Providing and fixing PVC valve of approved quality 50 mm nominal bore
OD250664/2022-2023:Providing and fixing PVC valve of approved quality 40 mm nominal bore
OD250665/2022-2023:Supplying and fixing 63 mm dia pvc valve including allcost
OD245348/2022-2023:Providing street fountains with vertical post by 75 mm P V C pipe 1.2 M long fixing in concrete and connecting the tap in position including all cost etc ( cost of connecting pipe should be paid separately)
51.2.3:Filling with Quarry Muck <br> Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
Water tank
2.7.2:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
60.5.2:DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2m long (1m in rock and 1m in concrete ) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc complete.
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
OD251514/2022-2023:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
WELL AND PUMP HOUSE
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
10.16.2:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
OD251793/2022-2023:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
OD251791/2022-2023: Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
BIBIL KUMAR
Bidder Name
ASHRAF. K.K.
BIBIL KUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_785628.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .