Loading…
Loading…
Tender Value
₹1.9 Cr
EMD Value
₹3.7 L
Closing Date
22 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
PLANNING
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Tenderer shall have a valid Electrical Contractor's License issued in the name of the firm by any State Government and shall furnish/attach all the particulars of the Electrical license along with their offer.
(a)The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b)(i) In case of tender for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works costing not less than the amount equal to 30% of advertised value of each component of tender, or (iii)Two similar works costing not less than the amount equal to 40% of advertised value of each component of tender, or (iv)One similar work costing not less than the amount equal to 60% of advertised value of each component of tender. Note:- Work experience certificate from private individual shall not be considered. However, in addition to work experience certificate issued by any Govt. Organization, work experience certificate issue by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated /registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of similar nature of work:- For this tender the following work only will be considered similar work for judging the technical eligibility criteria. "Design, Supply, Installation, Testing & Commissioning of HT/LT network like HT/LT panel, Overhead distribution network, earthing, laying of HT/LT cable etc. and associated electrical works. "
23 conditions · 3 needing a document upload
If firm ( Partnership Firm, Registered Society & Registered Trust) is required to submit Power of attorney it should be submitted as per given proforma enclosed in tender document.
If firm (Company registered under Companies Act 2013) is required to submit a copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company it should be submitted as per given proforma enclosed in tender document.
If firm LLP (Limited Liability Partnership) is required to submit a copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP, it should be submitted as per given proforma enclosed in tender document.
1.0 The tenderer should indicate clearly replies against item included in this check list. 2.0 Furnished the details of credential Alongwith attested copies of supporting document. 3.0 Quoted the accessories and essential spares. 4.0 Furnished your ITCC (income Tax clearance Certificates. 5.0 Quoted period of completion correctly. 6.0 Kept your offer valid for 60 days. 7.0 Visited the site and have studied the methodology To be adopted for completion of the work. 8.0 Submitted the integration scheme. 9.0 Submitted the BAR CHART /PERT CHART. 10.0 Submitted scheme of completion of work. 11.0 Submitted details of staff working under tenderer. 12. Submit the bid security certificate in appropriate form.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Electrical Work in Connection with Rebuilding of Rail Beam of Old Washing Line No. 1 & 2 of LKO Yard, Improvement/Up-gradation of North Coaching Complex Washing Line AND Provision of Fencing towards North side Pathway of Sadar Washing Line and Improvement of End Ramp at BSB end Flooring up to C&W office including repairs to office, etc. at LKO, AND Provision of covered Shedand Road Access for ART/LKO under LKO C&W Depot.
1197-SrDEE-NR-LKO-3rdCall~NR
1197-SrDEE-NR-LKO-3rdCall
Open
Works - General
9 Months
Lucknow, Uttar Pradesh
₹0
₹3.7 L
25 Sept 2026
25 Sept 2026
8 Oct 2026
121 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,86,02,174.45 | ||
| — | 2000.00 | — | — | ||
| Supply and Recessing/Fixing of PVC Conduit Pipe Conforming to IS. 9537 Part-III.1987 (Latest version) with Accessories Junction box, Bends etc. Including Making Chase, Plastering/Clamping etc. As per Technical Scope of Work. Size-25 mm dia (Medium). | — | — | — | 75,880 | |
| — | 1400.00 | — | — | ||
| Supply & Fixing of PVC Conduit Pipe Conforming to IS 9537 Part-III/1983 (latest version) On Surface with Accessories , Junction Box,Bends etc. Including Fixing,Clamping etc. As per Technical Scope of Work. Size-25 mm dia (Medium) | — | — | — | 44,296 | |
| — | 7000.00 | — | — | ||
| Supply & Fixing of HDPE (High Density Poly Ethylene Polymers) Pipe of Material Grade- PE 100 Grade, PN 16, On Surface with Accessories , Junction Box,Bends etc. Including Fixing,Clamping etc. As per Technical Scope of Work.Size-25 mm dia (Medium) | — | — | — | 6,09,000 | |
| — | 900.00 | — | — | ||
| Supply of Batten/Angle Holder Conforming to IS : 1258-2005 or Ceiling Rose, 3 Plate Conforming to IS : 371-1999 & Installation on the Junction Box of Laid Conduit Including Connections, Testing & Commissioning as per Site Requirement and as per Technical Scope of Work. | — | — | — | 14,553 | |
| — | 10200.00 | — | — | ||
| Supply of Following sizes FRLS PVC Insulated Multi Stranded Copper Conductor Single Core Cable conforming to IS 694 (Latest Version) , and Drawing in Laid (recessed /surface) M.S / PVC Conduit Pipe for Wiring of Point Wiring / Circuit Wiring / Sub Main / Main as required Including Connections, Testing and Commissioning. As per Technical Scope of Work Size-1.0 sq mm. | — | — | — | 1,07,508 | |
| — | 700.00 | — | — | ||
| Supply of Following sizes FRLS PVC Insulated Multi Stranded Copper Conductor Single Core Cable conforming to IS 694 (Latest Version) , and Drawing in Laid (recessed /surface) M.S / PVC Conduit Pipe for Wiring of Point Wiring / Circuit Wiring / Sub Main / Main as required Including Connections, Testing and Commissioning. As per Technical Scope of Work Size-1.5 sq mm. | — | — | — | 11,235 | |
| — | 4700.00 | — | — | ||
| Supply of Following sizes FRLS PVC Insulated Multi Stranded Copper Conductor Single Core Cable conforming to IS 694 (Latest Version) , and Drawing in Laid (recessed /surface) M.S / PVC Conduit Pipe for Wiring of Point Wiring / Circuit Wiring / Sub Main / Main as required Including Connections, Testing and Commissioning. As per Technical Scope of Work Size-2.5 sq mm. | — | — | — | 1,03,494 | |
| — | 11200.00 | — | — | ||
| Supply of Following sizes FRLS PVC Insulated Multi Stranded Copper Conductor Single Core Cable conforming to IS 694 (Latest Version) , and Drawing in Laid (recessed /surface) M.S / PVC Conduit Pipe for Wiring of Point Wiring / Circuit Wiring / Sub Main / Main as required Including Connections, Testing and Commissioning. As per Technical Scope of Work Size-4.0 sq mm. | — | — | — | 3,47,424 | |
| — | 15.00 | — | — | ||
| Supply and erection of modular metal boxes with white finish single mounting plates for fixing switches, plug sockets, fan regulators, and wiring connections. The metal boxes and boards shall be concealed within the wall as per the Technical Scope of Work. Size-( 12 modules) | — | — | — | 6,281.1 | |
| — | 20.00 | — | — | ||
| Supply and erection of modular metal boxes with white finish single mounting plates for fixing switches, plug sockets, fan regulators, and wiring connections. The metal boxes and boards shall be concealed within the wall as per the Technical Scope of Work.. Size-( 8 modules) | — | — | — | 7,089 | |
| — | 30.00 | — | — | ||
| Supply and erection of modular metal boxes with white finish single mounting plates for fixing switches, plug sockets, fan regulators, and wiring connections. The metal boxes and boards shall be concealed within the wall as per the Technical Scope of Work..Size-( 6 modules) | — | — | — | 8,138.4 | |
| — | 20.00 | — | — | ||
| Supply and erection of modular metal boxes with white finish single mounting plates for fixing switches, plug sockets, fan regulators, and wiring connections. The metal boxes and boards shall be concealed within the wall as per the Technical Scope of Work. Size-( 4 modules) | — | — | — | 3,618.6 | |
| — | 130.00 | — | — | ||
| Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.As per Technical Scope of Work. 5A/ 6A switch. | — | — | — | 18,201.3 | |
| — | 40.00 | — | — | ||
| Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.As per Technical Scope of Work. 3 pin 5A/6 A socket outlet. | — | — | — | 6,139.6 | |
| — | 25.00 | — | — | ||
| Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.As per Technical Scope of Work.15A/16 A switch | — | — | — | 4,166 | |
| — | 25.00 | — | — | ||
| Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.As per Technical Scope of Work. 6 pin 15A/16 A socket outlet. | — | — | — | 6,420.25 | |
| — | 5.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of Mobile Charging Board having 4 nos Sockets 5 Pin 6 Amp on Each Board, One no Indication Lamp on Each Board, Fuse Kit Kat on Each Boards Complete in all Respect as per Specification. As per technical scope of work. | — | — | — | 2,194.35 | |
| — | 41.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 1200 mm Sweep, BEE 5 Star Rated, Ceiling Fan with Brush Less Direct Current (BLDC) Motor, Class of Insulation: B, 3 nos. Metal Blades (Almunium Alloy), 30 cm Long Down Rod, 2 nos. Canopies, Shackle kit, Safety rope, Copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) Minimum 6.00, Air Delivery Minimum 220 Cum/Min , 350 RPM (Tolerance as per IS : 374-2019), THD Less than 10%, Remote for Speed Control and all Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 degree C (Max.), Insulation Resistance more than 2 Mega Ohm, Suitable for 230 V, 50 Hz, Single Phase AC Supply, Earthing etc. i/c External Connections with 1.5 sq.mm FRLS/HFFR, PVC Insulated Copper Conductor Single Core Cable and Earthing etc. as required. It shall also Include the Scope of Supply and Installation of Safety Cord of SS as per IS:302 Part 2 Sec-80. Dia & Length of such Cord shall be as per Recommendation of OEM of Fan and same shall be Approved by Railway. The Price Includes Remote for Speed Control. Details of BLDC Fan should be Approved Before Supply and Mounting work should be done as per Site Requirement. As per Technical Scope of Work. | — | — | — | 1,43,741.9 | |
| — | 117.00 | — | — | ||
| Earthing with 40 mm Dia GI Pipe Class 'B' , 3 Meter Long Earth Electrode a s per IS:3043 (latest version) t o Achieve Earth Resistance Less than 5 Ohms Including Construction of Masonry Enclosures with Hinged Cover plate of Cast Iron with Locking Arrangement (Approx. size 400 mmx 400 mm) on Top, Provision of Earth Plate,Connections from Earth Electrode to Switch gear/pole as per drawing & as per Technical Scope of Work | — | — | — | 2,32,033.23 | |
| — | 1650.00 | — | — | ||
| Supply, laying, connection & commissioning of 8 SWG GI wire & drawing in laid/on surface MS/PVC conduit pipe,confirming to relevant IS Buried in ground/recessing in floor from earth electrode to earth terminal of equipment's. Including supply of material. As per technical scope of work. | — | — | — | 22,390.5 | |
| — | 330.00 | — | — | ||
| Supply, laying, connection & commissioning of G.I. strip 40 x 5 mm (Galvanized) confirming to relevant IS , fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement. As per technical scope of work. | — | — | — | 27,291 | |
| — | 12.00 | — | — | ||
| Supplying and Fixing of CRCA sheet steel, 8 Way SPN, Double Door MCB Distribution Box, 240 V, IP54, on surface/recess, complete with tinned Copper Bus bar, Neutral Bus bar, Earth bar, Din bar, Interconnections, Powder Coated Including Earthing etc. a) DP MCB 25-32 A,10 KA "B/C" curve (incoming)-1 No, b) 25A DP RCCB = 01 No. having a Sensitivity Current 30 ma c) 6-32A ,10 kA MCB SP "B/C" curve = 04 Nos.(Outgoing). Make of MCB, RCCB & DBs: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager. As per Technical Scope of Work | — | — | — | 71,980.2 | |
| — | 3.00 | — | — | ||
| Supply, erection, fixing, testing and commissioning of CRCA sheet (8+24 )way, TPN,Double Door MCB/MCCB distribution board 415 V,IP 54 on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing with provision of following MCCB/RCCB/MCB complete with connection etc. a) MCCB 100 A,3P,16 KA (incoming)-1 No, b) 40 A DP RCCB = 03 No. having a sensivity current 30 ma(01 no on each phase) c) 5-32A ,10 KA MCB SP "C" curve = 18 Nos. (6 No on each phase for Outgoing).Make of MCCB/MCB/RCCB & DB: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager.As per technical scope of work. | — | — | — | 63,826.47 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of wall mounted/ recessed LT double door 2-way,IP54, distribution board made up of steel sheet, Phosphatized powder painted complete with neutral link, earth paint, din rail and prewired with DP RCBO's 25 (2P, 30 mA) Amp outgoing confirming to IS: 12640-2 & IEC-61009-1 or latest. Make of RCBO & DBs: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager. As per technical scope of work. | — | — | — | 12,424.3 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of wall mounted/ recessed LT double door 2-way,IP54, distribution board made up of steel sheet, Phosphatized powder painted complete with neutral link, earth paint, din rail and prewired with DP RCBO's 40 (2P, 30 mA) Amp outgoing confirming to IS: 12640-2 & IEC-61009-1 or latest. Make of RCBO & DBs: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager. As per technical scope of work. | — | — | — | 11,075.88 | |
| — | 130.00 | — | — | ||
| Supply & laying of B Class GI pipe duly clamped with rail/wall and provision of suitable clamps , nuts and bolts etc or wall as per techincal specification & drawing for passing cable of following sizes -50 MM (Dia) | — | — | — | 34,154.9 | |
| — | 100.00 | — | — | ||
| "Supply of HDPE (High Density Poly Ethylene Polymers) pipe of Material Grade- PE 63 Grade, IS 4984 Resistance to Chemicals- Exceptional Resistance to all External and Internal Corrosion. Resistant to Electrolytic Corrosion.Working Pressure in KGF/CM²) Specified Base Density- 940 to 958 kg/mtr3, Size- HDPE Pipe, Outer Diameter 63 mm ,Wall Thick Min. 3.0 mm & Max 3.4 mm " | — | — | — | 13,439 | |
| — | 3540.00 | — | — | ||
| "Supply of HDPE (High Density Poly Ethylene Polymers) pipe of Material Grade- PE 63 Grade, IS 4984 Resistance to Chemicals- Exceptional Resistance to all External and Internal Corrosion. Resistant to Electrolytic Corrosion.Working Pressure in KGF/CM²) Specified Base Density- 940 to 958 kg/mtr3, Size- HDPE Pipe, Outer Diameter110 mm ,wall thick Min. 5.9 mm & Max 6.6 mm" | — | — | — | 15,38,307 | |
| — | 16.00 | — | — | ||
| Supply, Erection, Testing, and Commissioning of 5 Meter Height Hot Dip Galvanized Octagonal Pole at Various Locations Complete with Double Arm of 300 mm Length for Fitting Installation and 04 No. M20 (EN 8 Gr) X 700 mm long J type Foundation Bolt Set and Casting of Concrete Foundation for Erection of Pole as per Approved Design and Site condition. Extra Depth and Required Earth work for Concrete Foundation have to be Provided by Contractor as per site Condition for Better Stability of Pole. The Pole shall be of Continuously Tapered with Single Longitudinal Welding. The Pole shall have a Minimum Dia of 130 mm at the Bottom and 70 mm at the Top. The Pole shall be Provided with a Base Plate of Size 200 mm X 200 mm X 12 mm with Provision for Fixing Foundation Bolts. The Pole with Base shall be Hot Dip Galvanized both Internally and Externally Having a Thickness of 70 Microns Average. The Galvanization shall be done as per IS 2629 / IS 26336/IS 4759. The Pole shall be Fabricated in a Single Section. The Pole shall be Provided with Terminal Inside the Pole for Fixing of MCB/RCCB/RCBO Including Supply & Fixing of SP MCB of 1A/2A. The Terminal shall be Protected with a 500 mm Long Reinforced and Weather Proof Door. The Door shall be Provided with an Internal Locking Arrangement and with a Chain Arrangement and Gasket. The Pole shall be Manufactured in an ISO 9001 & ISO 14001 Certified Fabrication unit to Ensure Consistent Quality. The Pole Foundation shall be Erected Strictly as per the Pole Manufacturer's Design. The Octagonal Post shall be Supplied Only after Obtaining Approval. As per Technical Scope of Work. | — | — | — | 1,67,976.48 | |
| — | 3.00 | — | — | ||
| Supply , erection ,testing & commissioning of 16 meter High Mast Tower system with following work. (a)Supply Installation, testing and commissioning of 16 High Mast Tower system totally hot dip galvanized, inside and outside in single dip, suitable for wind velocity 50 meter / sec as per IS 875 part-3. The mast shaft shall be in two sections with one longitudinal seam weld per section and no circumferential weld which can be jointed by slipstress method. The system inincluding head frame, steel wire roap 6 mm dia (7/19construction) Double drum winch, galvanized lantern carriage arrangement suitable for minimum 8 lumiaries symmetrically. The mast shall have integral type high power reverseable Power tool for electrical operation of raising and lowering of lantern carriage mounted in the base compartment of high mast with arrangement to couple with the winch and torque limiter -1 Nos. (b) Supply and erection of foundation bolt manufactured from special steel with nuts, washers, anchor plates and templates-1Set. (c) Supply design and casting of suitable shallow foundation with M-25 for the high mast considering the safe soil bearing capacity at site as 10T / sq meter at 2 meter depth- 1 Nos. (d) Supply erection testing commissioning of Twin dome aviation light having twin type construction with 2 No light of LED type. - 1 Set.(e) Supply installation testing commissioning of heavy gauge hot dipped galvanized lightning finials-1 Nos.(f) Supply installation testing and commissioning of feeder panel comprising of main incoming switch of MCB's, time switch, contactor, reversing starter and protective system etc as required for operation of high mast system - 1 Nos.(g) Supply erection testingand commissioning of copper plate earthing with 600X600X3 mm copper earth plate, pipe and electrode as per drawing and confirming to specification at annexure & IS 3043 including connection to the mast with Copper strip of size 40X6 mm- 2 No.Make of High Mast Tower:- Bajaj, Philips, Crompton, Valmont, Transrail, Wipro, Utkarsh, ,BPP or Other reputed make with prior approval. | — | — | — | 6,60,954.9 | |
| — | 70.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Complete 1 x (18- 20 Watt) , 1200 mm(±2%) length , Retrofitment,T-8 type LED Tube Light Fitting with Inbuilt Driver having Decorative Pin type End Caps and Copper contacts with Diffuser made of Transparent Polycarbonate, Conforming to PCEE/NR Specification No: PCEE/NR /121- Elect/PS/2018(Rev -'3' ) Dated : 28/06/18 & PCEE/NR /121- Elect/PS/2019(Rev-'4') Dated 04.11.2019 or Latest . Details of Light Fitting & Fixture Should be Approved Before Supply and Mounting Work should be done as per Site Requirement. As per Technical Scope of Work | — | — | — | 34,707.4 | |
| — | 30.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of 40W Polycarbonate Housing LED Industrial Batten, IP-65, Conforming to PCEE/NR Specification No: PCEE/NR /121- Elect/PS/2018(Rev - '3' ) Dated : 28/06/18 & PCEE/NR /121- Elect/PS/2019(Rev-'4') Dated 04.11.2019 or Latest. Details of Light Fitting & Fixture Should be Approved Before Supply and Mounting Work should be done as per Site Requirement. As per Technical Scope of Work | — | — | — | 56,121.6 | |
| — | 32.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of LED Street Light Fitting Complete with Driver 45 Watts, Conforming to PCEE/NR Specification No: PCEE/NR /121- Elect/PS/2018(Rev -'3' ) Dated : 28/06/18 & PCEE/NR /121- Elect/PS/2019(Rev-'4') Dated 04.11.2019 or Latest. Details of Light Fitting & Fixture Should be Approved Before Supply and Mounting Work should be done as per Site Requirement. As per Technical Scope of Work | — | — | — | 1,62,991.36 | |
| — | 8.00 | — | — | ||
| "Supply, Installation, Testing & Commissioning of LED Flood Light Fitting Complete with Driver 120 Watts , Conforming to PCEE/NR Specification No: PCEE/NR /121- Elect/PS/2018(Rev - '3' ) Dated : 28/06/18 & PCEE/NR /121- Elect/PS/2019(Rev-'4') Dated 04.11.2019 or Latest.Details of Light Fitting & Fixture Should be Approved Before Supply and Mounting Work should be done as per Site Requirement. As per Technical Scope of Work | — | — | — | 83,911.04 | |
| — | 31.00 | — | — | ||
| "Supply, Installation, Testing & Commissioning of LED Flood Light Fitting Complete with Driver 200 Watts , Conforming to PCEE/NR Specification No: PCEE/NR /121- Elect/PS/2018(Rev - '3' ) Dated : 28/06/18 & PCEE/NR /121- Elect/PS/2019(Rev-'4') Dated 04.11.2019 or Latest.Details of Light Fitting & Fixture Should be Approved Before Supply and Mounting Work should be done as per Site Requirement. As per Technical Scope of Work" | — | — | — | 3,29,836.28 | |
| — | 560.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of LED Pit Light Fitting Complete with Driver, 18 watts,Input voltage 48 V AC Conforming to PCEE/NR Specification No: PCEE/NR /121- Elect/PS/2018(Rev -'3' ) Dated : 28/06/18 & PCEE/NR /121- Elect/PS/2019(Rev-'4') Dated 04.11.2019 with Correction Dated.10.02.2020 or latest , Details of Light Fitting & Fixture Should be Approved Before Supply and Mounting Work should be done as per Site Requirement. As per Technical Scope of Work | — | — | — | 17,70,809.6 | |
| — | 355.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of LED Bulk Head Light Fitting Complete with Driver 22 Watts,Input voltage 48 V AC with Anti Theft Mounting Arrangement/ Protection Jaali as per Site Requirement, Conforming to PCEE/NR Specification No: PCEE/NR /121- Elect/PS/2018(Rev -'3' ) Dated : 28/06/18 & PCEE/NR /121- Elect/PS/2019(Rev-'4') Dated 04.11.2019 with Correction Dated.10.02.2020 or latest. Details of Light Fitting & Fixture Should be Approved Before Supply and Mounting Work should be done as per Site Requirement. As per Technical Scope of Work | — | — | — | 14,79,221.1 | |
| — | 560.00 | — | — | ||
| Supply,Installation testing & commissioning of Suitable Protection Jaali for Pit Light made of MS angle 25X25X3 mm & MS Jaali 25mm X 25mm, Wire Dia as 2mm. Size and Design of Jaali for Light Fitting & Fixture should be Approved Before Supply and Fixing & Grouting work Should be Done as per Site Requirement.As per Technical Scope of Work. | — | — | — | 2,73,996.8 | |
| — | 110.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of Cable End Termination Kit and Lugs of Cable for Energization,Suitable for Cable Size 25-150 sqmm cable 2 Core. As per Technical Scope of work. | — | — | — | 20,128.9 | |
| — | 13.00 | — | — | ||
| Supply, Installation , Testing and Commissioning of LT Heat Shrinkable Straight Through Jointing Kit and Jointing of Cable. As per Technical Scope of work.Suitable for Cable Size 25- 150 Sq.mm,2 core ( Only LT cable supplied by the Railway) , Make:-Raychem, 3M, Densons, Cabseal or other reputated make with prior Approval. | — | — | — | 23,262.59 | |
| — | 138.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of End Termination Kit of 3-½ C / 4.0 C X35 to 400 sq. mm. LT XLPE Cable as per Specification. (One set means lugs in R-Y-B-N).Suitable for Cable Size 3-½ C / 4.0 C X35 to 400 sq. mm. As per Technical Scope of work | — | — | — | 53,557.8 | |
| — | 18.00 | — | — | ||
| Supply, Installation , Testing and Commissioning of Heat Shrinkable Straight Through Jointing Kit and Jointing of Cable. As per Technical Scope of work.Suitable for Cable Size 35-185 Sq.mm,4 core , ( Only LT cable supplied by the Railway), Make:-Raychem, 3M, Densons, Cabseal or other reputated make with Prior Approval. | — | — | — | 74,972.7 | |
| — | 8000.00 | — | — | ||
| Laying of 1.1 KV grade LT XLPE Insulated Armoured, Aluminium Conductor Cable of Different Sizes as per Cable route Plan Approved by Railways and Meggering of Cable before and after its Laying. As per Technical Scope of work( Cable will be Supplied by the any Railway store of Lucknow Division) | — | — | — | 80,000 | |
| — | 3500.00 | — | — | ||
| Excavating and Refilling of Trench in Normal Soil to the Level of Ground with Rammed Earth as per Site Incharge and as per Cable Route Plan. so as not to form a Drain. Size of Trench should be 0.3 Mtrs. Wide & 1 Mtr. Deep as per Cable Plan and Instructions of SSE/incharge. It shall confirm to the Safe Distance as per Cable Plan. It also Includes Clearance of Roots of Trees & Bushes. As per Technical Scope of Work. | — | — | — | 3,07,545 | |
| — | 18950.00 | — | — | ||
| Supply and Laying of 2nd Class New Bricks in the Trench and Laying as per Cable Plan and Instructions of SSE/incharge. As per Technical Scope of Work. | — | — | — | 1,76,235 | |
| — | 4000.00 | — | — | ||
| Clamping of Cable with Wall / Trusses / Cable Tray / Angle with help of Nut, Bolt & Washer. The Clamp made out of GI strip Size not Less than 32X5 mm).As per Technical Scope of Work. | — | — | — | 1,26,320 | |
| — | 120.00 | — | — | ||
| Platform Surface/Concrete cutting for Excavation of Cable Trench 300 mm Wide x 300 Deep, Re-fitting of Soil and Re-Plastering of Excavated Trench with Cement on the PF's to bring Original Shape.As per Technical Scope of Work. | — | — | — | 65,718 | |
| — | 3500.00 | — | — | ||
| Horizontal boring size up to 125 mm Dia & minimum 1.0 Mtr Depth from Ground Level by Horizontal Deep Drilling Machine or Suitable Machine Including Supply and Commissioning of DWC HDPE Pipe as per IS-16205 or latest. Size Outer Dia 120 mm and Inner Dia 103 mm. DWC HDPE Pipe to be Provided at the Starting Bore and at End of the Bore upto Maximum Feasibility for Horizontal Bore Complete in all respect as per Site requirement and as per Technical Scope of Work. | — | — | — | 17,53,955 | |
| — | 150.00 | — | — | ||
| All Work of Manual Horizontal Boring and Trenchless Cabling along with Supply, Transportation and Insertion of DWC HDPE Pipe as per IS-16205 ( Latest version, ( ISI marked ) and the Laying of Cable in the boring under the Track /Road etc. as per Instruction of Site Incharge by using Pipe of Size 120 mm Nominal Dia in which required number of Cables to be crossed. DWC HDPE Pipe will be Supplied by Contractor. The Depth of Horizontal Boring should be Minimum 1.0 m from Rail Flange/Road Level.As per Technical Scope of Work. ( Cable will be supplied by the any Railway store of Lucknow Division) | — | — | — | 1,78,756.5 | |
| — | 20.00 | — | — | ||
| Gas Cutting of Damaged/ Overaged/Corroded Street LightTubular/ Rail/MS Angle Poles in Pieces of Required Size & Transportation of the Pieces of /Tubular/Rail poles /MS Angle to the Store of SSE/Elect or as Directed by Depot Incharge. As per technical scope of work. | — | — | — | 21,666.8 | |
| — | 2.00 | — | — | ||
| Supply, erection, testing and commissioning of minimum 1400 VA inverter, A.C. input voltage 160V-280V, DC input voltage 24V,output voltage same as supply voltage, when inverter is working 220V +(-) 10%, output frequency 50 +(-) 0.5%, output wave form: square wave, Protection: over load battery over charge battery deep discharge, Battery charge: constant current thyristor controlled for extra wide range with Supply and erection of 02 Nos. 12 V 150 AH LMLA tubular battery complete in all respect with suitable trolley and required wiring with material to connect inverter with source point and load point available at site. Make of inverter: Microtek, Sucam, Luminous, livguard. Make of Battery: Exide, OKAYA, AMRON, Microtek, Luminous, livguard. As per technical scope of work. | — | — | — | 74,166.76 | |
| — | 30.00 | — | — | ||
| Manufacturing and Supply, Erection and Commissioning of Bus bar type Junction box, 4 pole Alluminium Bus bar 4 Strip, Capacity 200 Amp each Bus bar, Enclosure made of 16 SWG CRCA with Powder Coating, Bus bar not less than 250 mm Length or Suitable for 4 Way Complete as per IS and site requirement Including Civil Foundation work required to Install Junction box. As per Technical Scope of Work. | — | — | — | 1,40,848.8 | |
| — | 10.00 | — | — | ||
| Supply, Assembly, Fixing and Commissioning of Pole mounted/ Wall Mounted Junction Box of Size 300 X 300 X170 IP-65 Including Standard Connection Plate TPN-100 Amps in DMC with Colour caps. Polycarbonate Junction Box Similar to M/s HENSEL Model No. MI- 0201.of Pole/Wall Mounted Junction Box as per site requirement and Direction of Site Incharge. As per Technical Scope of Work. | — | — | — | 24,767.2 | |
| — | 3.00 | — | — | ||
| Design, Manufacture, Supply, Erection, Testing & Commissioning of Front Operated Double door type Weather Proof Feeder Pillar Suitable for IP-65 Degree of Protection with Digital measuring Instrument & Aluminium Bus-bar Arrangement, Conforming to IS/IEC 61439 -1 & 2,Edittion 3, 2020 with Latest Amendments or latest. Comprising with the Following MCCB'sfixed in it.: (i) Incomer 400 Amp, FP, 35 kA MCCB with Adjustable Thermal & Fixed Magnetic Release & Spreaders-2 No (ii) Buscoupler 400Amp FP, 35 kA, MCCB with Adjustable Thermal & Fixed Magnetic Release & Spreaders-1 No (iii) 400 Amp FP Manual Change over-1 No (iv) Outgoings- 250Amp FP 35 kA MCCB with Adjustable Thermal & Fixed Magnetic Release & Spreaders-2 No (iv)Outgoing- 125Amp FP 35 kA MCCB with Adjustable Thermal & Fixed Magnetic Release & Spreaders-4 No, (v) Outgoing 63 Amp FP 35 kA MCCB with Adjustable Thermal & Fixed Magnetic Release & Spreaders-2 No..Digital measuring instrument, indication lamp on all incoming and outdoor feeder including Civil Foundation work Required to Install Panel As per Drawing Approved by Railways and Technical Scope of Work.Make of MCCBs:- Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager conforming to relevant IS/IEC. The LT Panel Manufacturer should be CPRI-Approved . | — | — | — | 14,23,500 | |
| — | 2.00 | — | — | ||
| Design, Manufacture, Supply, Erection, Testing & Commissioning of Front Operated Double door type Weather Proof Feeder Pillar Suitable for IP-65 Degree of Protection with Digital measuring Instrument & Aluminium Bus-bar Arrangement, Conforming to IS/IEC 61439 -1 & 2,Edittion 3, 2020 with Latest Amendments or latest. Comprising with the Following MCCB'sfixed in it. (i) Incomer 250 Amp, FP, 35 kA MCCB with Adjustable Thermal & Fixed Magnetic Release & Spreaders-1 No (ii) Outgoing- 125 Amp, FP, 35 kA MCCB with Adjustable Thermal & Fixed Magnetic Release & Spreaders-2 No (iii) Outgoing- 63 Amp, FP, 35 kA MCCB with Adjustable Thermal & Fixed Magnetic Release & Spreaders-2 No= 02 No. (outgoing).Digital measuring instrument, indication lamp on all incoming and outdoor feeder including Civil Foundation work Required to Install Panel As per Drawing Approved by Railways and Technical Scope of Work.Make of MCCBs:- Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager conforming to relevant IS/IEC. The LT Panel Manufacturer should be CPRI-Approved . | — | — | — | 1,80,810 | |
| — | 9770.00 | — | — | ||
| Fabrication, Supply and Fixing of MS stand/ Cabinets or any other MS Structure for Precooling Points, Battery Charger, Electrical Panels, covering of any Electrical Structure or Cable Support Structure. The work Includes Structural Steel work, cutting, Welding Riveting, Nut Bolts or Welded in Built up sections, Trusses and framed work and Applying Primary coat of Steel primer and one coat of Painting of Approved Shade, as per site requirement/ approved drawing. The Work also Includes Foundation work and Grouting of MS structure/stand as per Site requirement and direction of Site Incharge. As per Technical Scope of Work. | — | — | — | 10,86,033.2 | |
| — | 76.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of Outdoor Type Double Door 415 Volt Pre-Cooling cum 110 Volt Battery Charging Box Conforming to IS/IEC 61439 -1 & 2,Edittion 3, 2020 with Latest Amendments or latest, Made of 14 SWG,having IP 65 Protection, having One no.100 Amps FP MCCB Fixed Type Thermal Magnetic Release 35 kA and One no. 16A DP MCB B/C "Curve" in AC Compartment And One no. 32 Amps DC series MCB DP suitable for 150V DC supply in DC Compartment Including one Number 63 Amp Plug and Socket, one Number 32 Amp Plug and Socket and one Number 16 Amp Plug and Socket,All Plug and Socket should be IP 67 rating.AC compartment shall have TPN Aluminium Bus bar for IN/OUT Looping of XLPE Cable of Size up to 4x240 sqmm. and DC Compartment Aluminium Bus bar for IN/OUT Looping of XLPE Cable of Size up to 2/x70 smm.Civil Foundation Work Including all Labour and Material.As per Drawing Approved by Railways and Technical Scope of Work.Make of MCCBs:- Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager conforming to relevant IS/IEC. The LT Panel Manufacturer should be CPRI-Approved . | — | — | — | 26,22,000 | |
| — | 26.00 | — | — | ||
| Design, Manufacturing, Supply, Fixing, Testing and Commissioning of Rolling Examination LED based Lights complete with 03 Nos. 30 watt LED flood light Fitting Conforming to PCEE/NR Specification No: PCEE/NR /121- Elect/PS/2018(Rev -'3' ) Dated : 28/06/18 & PCEE/NR /121- Elect/PS/2019(Rev-'4') Dated 04.11.2019 or Latest.In a Row Fitted on MS Bracket in MS Box, Front Cover with Protection Wire Mesh , the above MS box Supported on MS angle (50x50x5 mm), the Base Angle to be Grouted in RCC Foundation, the above MS Box should be having Provision of 02 nos. Earthing Stud Suitable for GI Earthing Wire/Strip and Suitable Locking Arrangement as per Actual site Requirement Complete. The MS box Should be Painted in Approved Shade. As Civil Foundation Work Including all Labour and Material.As per Drawing Approved by Railways and Technical Scope of Work | — | — | — | 6,17,511.44 | |
| — | 1.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of Train Lighting Battery Charger 110 volt D.C. 300 Amp Output with Input Voltage 415 volt Three Phase 50Hz as per Specification No. CEE/Spec/Battery Charger / Pit/110 volt/005, December 2005.As per Attached Specification and Technical Scope of Work. | — | — | — | 1,96,613.38 | |
| — | 7.00 | — | — | ||
| Design, Supply, Installation, Testing and Commissioning of Step Down Transformer Outdoor type, 10 KVA, with Control Panel. Specifications for Transformer ,Connection of Winding Primary-STAR, Secondary- DELTA, Input Voltage 3 Ph, 440 V AC( +/- 5%), Output Voltage 83 V (P-P) 48 V(P-N) AC ( +/- 5%), Minimum 4 Output Terminals, Type of Cooling-Oil Cooled, Efficiency-more than 95%, Winding -Copper Core Mitered CRGO Notching Core Material, Display - Digital, Control card-Easy Maintenance & Service ability, Temp. Rise-45° C above Ambient Temperature, Frequency- 50Hz, Protections- Low/High voltage ,Control Panel: Size & Capacity of Control Panel should be as per Transformer Capacity 10 KVA & Connected load. Control Panel should have 3 Phase Incoming & Required Capacity Outgoing Feeders. Both Transformer & Control Panel should be Approved by Railway Before Installation as per Site Requirement. Civil Foundation Work Including all Labour and Material.As per Drawing Approved by Railways and Technical Scope of WorkScope of Work | — | — | — | 7,86,975.84 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
ALLACSUPTO12.08.2026_compressed.pdf
ATTACHMENT
Tender_document_1197-3rdCall.pdf
ATTACHMENT
CorrectionCEEspecdt.10.02.2020.pdf
ATTACHMENT
BatteryCharger.pdf
ATTACHMENT
LatestCEESpec-1_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .