Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.6 L+₹9,202.50 (0.96%)Rejected-Finance 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹10.2 L+₹68,059.80 (7.13%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹10.5 L+₹95,428.20 (10.0%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹11.1 L+₹1.6 L (16.5%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹19,420
Closing Date
30 May 2025, 6:00 pmClosed
Harikesh Meena EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2025_MES_706011_1
8847
Open Tender
Civil Works
Item Rate
90 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE ARMY BARODA
₹19,420
Yes
21 Jul 2025
30 Apr 2025
31 May 2025
30 Apr 2025
30 May 2025
15 May 2025
1 May 2025 - 15 May 2025
Amount
Supply and laying, testing and commissioning of LT cable XLPE insulated screened and PVC bedded galvanised steel strip or conductor 1.1KV grade cross sectional area 185 sq mm 3.5 core laid in trenches/duct/floor or on pole or through pipe all as specified and directed and including taking down old LT cable.
Supply and laying, testing and commissioning of LT cable XLPE insulated screened and PVC bedded galvanised steel strip or conductor 1.1KV grade cross sectional area 70 sq mm 3.5 core laid in trenches/duct/floor or on pole or through pipe all as specified and directed and including taking down old LT cable.
Supply and laying, testing and commissioning of LT cable XLPE insulated screened and PVC bedded galvanised steel strip or conductor 1.1KV grade cross sectional area 50 sq mm 3.5 core laid in trenches/duct/floor or on pole or through pipe all as specified and directed and including taking down old LT cable.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core and including taking down old LT cable.
Excavation in trenches in hard/ dence soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles/foundation or foundation etc and getting out complete all as specified and directed by Engr-in-Charge.
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed by Engr-in-Charge.
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtrs above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engr-in-ChargeNote:- Punned thickness i.e. 18mm will be measured and paid.
M&L well burnt bricks sub class 'B'as in protection of cable laid dry , flat abutting each other width wise all as specified and directed by Engr-in-Charge.
Supply and laying and fixing in position galvanized iron pipe 80mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches Complete all as Specified and Directed by Engr-In-Charge
Supply and laying and fixing in position galvanized iron pipe 50mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches Complete all as Specified and Directed by Engr-In-Charge
S&F double door metallic sheet metal enclosure DB double door VTPN suitable for housing 125 MCCB as incomer 8 Way 415 Volts with 160 Amps rated bus bars Including taking down old ones .
S&F double door metallic sheet metal enclosure for MCB DB double door TPN 4 Way 415 Volts with 200 Amps rated bus bars including taking down old ones. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate.
S&F testing and commissioning of MCB TPN 63 A ,415 volt 50 Hz,10ka in accordance with IEC 60947- 2 having C-curve characteristics connected with suitable lugs including taking down old ones.All as specified and directed by Engr-in charge
S&F MCCB 125 Amps 4 pole, suitable for 415 V breaking capacity 16 KA connected in wall/surface with wire and lugs all as specified and directed.
S&F for replacement of MCCB 4 pole 415 volt suitable for existing LT panel of adjustable type 350 Amps with breaking capacity 36 KA complete all as specified and directed.Note- LT panel busbar to be connected MCCB copper cable included in quated rate.
S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs.
S&F testing and commissioning of MCB SP 63 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron strip 25x4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed by Engr-in-Charge.Note:- Cost of earth strip and GI protection pipe upto a distance 7.5 metre shall be included in the quoted rate.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron wire 4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed by Engr-in-Charge Note:- Cost of earth GI wire and GI protection pipe upto a distance 7.5 metre shall be included in the quoted rate.
S&F in replacement LT cable jointing kit for 1.1 KV grade cable for staright through joint complete with jointing material(Epoxy based) and accessories suitable for 3 .5 Core XLPE armoured Al cable of following size : Note: (a) Excavation and earth work required for cable joint and refilling is deemed to be incuded in the quoted rate.
25 to 50 Sqmm
70 to 95 Sqmm
120 to 185 Sqmm
FAIZA ENTERPRISE (BID ID -3309541)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3303566)
PATELS (BID ID -3309413)
Badri Electricals (BID ID -3309288)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .