ANNUAL RATE CONTRACT FOR ELECTRICAL MAINTENANCE JOBS AFTER COMMISSIONING AT HURL GORAKHPUR
2022_HURL_685013_1
HURL/GKP/CNM/22-23/C-157/ARC
Open Tender
Miscellaneous Services
Tender cum Auction
365 days
HURL ADMIN BUILDING Gorakhpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹5 L
Yes
9 Jan 2023
21 Apr 2022
13 May 2022
22 Apr 2022
12 May 2022
22 Apr 2022
Amount
Part A- MAINTENANCE OF LV (415V) MOTORS
Motor rating up to ≤15kW
Motor rating from 15kW < to ≤ 30kW
Motor rating from 30kW < to ≤ 100kW
Motor rating from 100kW < to ≤ 300kW
BREAKDOWN MAINTENANCE OF LV MOTOR
Motor rating up to ≤15kW
Motor rating from 15kW < to ≤ 30kW
Motor rating from 30kW < to ≤ 100kW
Motor rating from 100kW < to ≤ 300kW
Installation or removal of LV motor
Motor rating up to ≤15kW
Motor rating from 15kW < to ≤ 30kW
Motor rating from 30kW < to ≤ 100kW
Motor rating from 100kW < to ≤ 300kW
MAINTENANCE OF HV (11kV) MOTORS
Motor rating up to ≤1000kW
Motor rating from 1000kW < to ≤ 3000kW
INSTALLTION OR REMOVAL OF HT MOTOR
Motor rating up to ≤1000kW
Motor rating from 1000kW < to ≤ 3000kW
MAINTENANCE OF MV (3.3kV) MOTORS
Motor rating up to ≤500kW
Motor rating from 500kW < to ≤ 1000kW
BEARING REPLACEMENT OF LV MOTOR
Motor rating up to ≤500kW
Motor rating from 500kW < to ≤ 1000kW
INSTALLTION OR REMOVAL OF MV MOTOR
Motor rating up to ≤500kW
Motor rating from 500kW < to ≤ 1000kW
OIL REPLACEMENT IN MOTOR SLEEVE BEARINGS
MOV ACTUATOR MAINTENANCE
SWITCHGEARS
MAINTENANCE OF 11KV SWITCHBOARD PANELS
MAINTENANCE OF 11KV SWITCHGEAR VCB
11kV, VCB rating up to ≤1250A
11kV, VCB rating from 1250A < to ≤ 1600A
11kV, VCB rating from 1600A < to ≤ 2500A
MAINTENANCE OF 3.3KV SWITCHBOARD PANELS
MAINTENANCE OF 3.3KV SWITCHGEAR VCB
3.3kV, VCB rating up to ≤630A
3.3kV, VCB rating from 630A < to ≤ 800A
3.3kV, VCB rating from 800A < to ≤ 1250A
MAINTENANCE OF 415V LT SWITCHBOARD PANELS
MAINTENANCE OF 415V SWITCHGEAR ACB
415V, ACB rating up to ≤630A
415V, ACB rating from 630A < to ≤ 800A
415V, ACB rating from 800A < to ≤ 1250A
415V, ACB rating from 1250A < to ≤ 3200A
MAINTENANCE OF (415V) SFU /CONTACTOR BASED PANELS
Power feeder rating up to ≤32A
Power feeder rating from 32A < to ≤ 63A
Power feeder rating from 63A < to ≤ 125A
Power feeder rating from 125A < to ≤ 250A
Power feeder rating from 250A < to ≤ 400A
Power feeder rating from 400A < to ≤ 630A
MAINTENANCE OF 132KV OUTDOOR SWITCHYARD EQUIPMENTS
Battery Charger 24V FCBC of rating ≤ 50A
Battery Charger 220V FCBC of rating ≤ 50A
Battery Charger 220V FCBC of rating 50A < to ≤ 100A
Battery Charger 220V FCBC of rating 100A < to ≤ 150A
MAINTENANCE OF UPS
UPS of rating ≤ 1.5kVA
UPS of rating 5kVA < to ≤ 10kVA
UPS of rating 10kVA < to ≤ 30kVA
UPS of rating 80kVA & ≤ 150kVA
MAINTENANCE OF DISTRIBUTION BOARDS
Preventive Maintenance of 115/240V ACDB (As per PM checklist)
Preventive Maintenance of 220V DCDB (As per PM checklist)
Preventive Maintenance of 415V MLDB (As per PM checklist)
Preventive Maintenance of 415V Wall/Structure mounted distribution board (As per PM checklist)
Preventive Maintenance of DCLP Wall/Structure mounted distribution board (As per PM checklist)
Preventive Maintenance of Wall/Structure mounted feeder pillar box (As per PM checklist)
Preventive Maintenance of Wall/Structure mounted Welding receptacle (As per PM checklist)
CAPACITOR BANK MAINTENANCE
CT/PT REPLACEMENT IN HT/LT SWITCHBOARDS
11KV SWITCHBOARD PANEL CT/PT
3.3KV SWITCHBOARD PANEL CT/PT
415V SWITCHBOARD PANEL CT/PT
TEMP CONN.HYDROJETTING M/C.UPTO 200 KW
TRANSFORMER MAINTENANCE
VFD Maintenance as per PM Checklist/Best Maintenance Practices
LIGHTING/EARTHING
Installation of 8 SWG GI wire for earthing
Installation of 10 mm GI wire for earthing
EARTHING WITH GI STRIP
Installation / connection of earthing Strip GI-75X10MM
Installation / connection of earthing Strip GI-50 X 6mm
EARTH PIT RESISTANCE MEASUREMENT
INSTALLATION OF EARTH PITS AS PER IS 3043
MONSOON PROTN-EXD TYPE POWER SOCKET
MONSOON PROTN-EXD TYPE LIGHT DB
CHECK & RECTI.OF LIGHT CIRCUIT NON-HAZ
CHECK& RECTI.OF LIGHT CIRCUIT HAZ-AREA
CABLES
REM TEL CAB.JNT ST TH-PIJF-02 PAIR
REM TEL CAB.JNT ST TH-PIJF-05 PAIR
REM TEL CAB.JNT ST TH-PIJF-20PAIR
CAB.LAY-UNDER GROUND <= 21.5 MM OD
CAB.LAY-UNDER GROUND 22 TO 50 MM OD
CAB.LAY-UNDER GROUND 51 TO 100 MM OD
CABLE TERMINATION AND GLANDING
Cable glanding and termination-LT cable 1.1kv- 1Core X 400 sqmm
Cable glanding and termination-LT cable 1.1kv- 16 Core X<=2.5sqmm
Cable glanding and termination-LT cable 1.1kv- 1CX >185 to 300sqmm
Cable glanding and termination-LT cable 1.1kv- 19CX <=2.5sqmm
Cable glanding and termination-LT cable 1.1kv- 12CX <=2.5sqmm
Cable glanding and termination-LT cable 1.1kv- 7CX <=2.5sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX 300 sqmm
Cable glanding and termination-LT cable 1.1kv- 27CX<=2.5sqmm
Cable glanding and termination-LT cable 1.1kv- 37CX <=2.5sqmm
Cable glanding and termination-LT cable 1.1kv- 1CX <=16sqmm
Cable glanding and termination-LT cable 1.1kv- 1CX >35 to 70 sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX 240 sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX 185 sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX 150 sqmm
Cable glanding and termination-LT cable 1.1kv- 1CX >70 to 120sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX >70 to 120 sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX >35 to 70 sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX >16 to 35 sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX >6 to 16 sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 4CX 4 to 6 sqmm
Cable glanding and termination-LT cable 1.1kv- 2 to 4CX<=2.5sqmm
Cable glanding and termination-LT cable 1.1kv- 1CX >120 to 185sqmm
Removal of cable glanding and termination
Removal of cable glanding and termination-LT cable 1.1kv- 1CX >300 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 1CX >185 to 300sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 1CX >120 to 185sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 1CX >70 to 120sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 1CX >35 to 70 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 1CX >16 to 35sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 1CX <=16sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 37CX <=2.5sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 27CX <=2.5sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 19CX <=2.5sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 12CX <=2.5sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 7CX <=2.5sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX 300 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX 240 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX 185 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX 150 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX >70 to 120 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX >35 to 70 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 3.5CX >16 to 35 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 4CX >6 to 16 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 4CX 4 to 6 sqmm
Removal of cable glanding and termination-LT cable 1.1kv- 2 to 4CX <=2.5sqmm
Laying of different size of pipes(GI/Hume/HDPE/PVC etc. as FIM) in pre-excavated trench/above ground locations.
PVC/HDPE pipe laying for cable- >75 to 150 mm dia
PVC/HDPE pipe laying for cable- >150 mm dia
GI pipe laying for cable<=75mm dia
PVC/HDPE pipe laying for cable<=75mm dia
INSTAL LT AND HT CABLE ROUTE MARKER MS CHANNEL TYPE
Installation of LT cable route marker MS channel type as per directions & approval of EIC.Job shall be completed in all respects with utmost safety precautions. All tools & tackles under contractor's scope as per the contract.
Cable laying above ground > 100 mm OD ( Overall outer diameter of cable) Excavation excluded
Cable laying above ground 51 to 100 mm OD ( Overall outer diameter of cable) Excavation excluded
Cable laying above ground 22.5 to 50 mm OD ( Overall outer diameter of cable) Excavation excluded
Cable laying above ground <=21.5 mm OD ( Overall outer diameter of cable) Excavation excluded
FABRIC & ERECT PERFORATED/ LADDER TRAY LAYING:
CABLE TRAY LAYING>100MM TO 150MM
LAYING OF CABLE TRAY ABOVE 150MM UPTO 250MM
LAYING OF CABLE TRAY, >250MM TO 450MM
LAYING OF CABLE TRAY UPTO 100MM
CABLE TRAY LAYING>450MM TO 600MM
CABLE TRAY LAYING >600 TO 750 MM
FABRIC & ERECT PERFORATED/ LADDER TRAY BEND .Job involves fabricating ladder type cable tray bends of various sizes at site and installation/erection as per requirements. Detailed scope as per the contract
FABR & EREC LAD TRAY BEND>600 UPTO 750MM
FABR & EREC LAD TRAY BEND>450 UPTO 600MM
FABR & EREC LAD TRAY BEND>150 UPTO 250MM
FABR & EREC LAD TRAY BEND>100 UPTO 150MM
FABR & EREC LAD TRAY BEND >75 UPTO 100MM
FABR & EREC LAD TRAY BEND UPTO 75MM
Laying and termination-Telephone cable of different sizes
Laying and termination TEL CAB.-02 PAIR
Laying and termination CAB.-05 PAIR
Laying and termination CAB.-20PAIR
Telephone installation/removal with its LAN and supply connection
FO Cable Laying
FO cable termination/Splicing/testing
LHS Cable laying for Fire systems
FP/NFP (FLAME PRROF/NON FLAME PROOF) LIGHTING & CEILING FAN EQUIPMENT MAINTENANCE
Replacement of LED/GLS lamps/floodlight fixture lamp 300/500/400/250/150 Watt
Replacement of choke/ballast in high/medium bay type fluorescent tube fixture
Replacement of items like ceiling fan pin/rubber bush
Replacement of LED/DC/GLS lamps/CFL up to 100 Watt in normal fitting
Replacement of lamp holder in aviation fixture
Replacement of condenser/starter in open industrial reflector type fluorescent tube fixture
Replacement of condenser/starter in decorative type fluorescent tube fixture
REP.OF 20/36/40/80 WATT FLUOR TUBES
Replacement of condenser/starter in high/medium bay type fluorescent tube fixture
Replacement of choke /ballast in HPMV/HPSV/LPSV/MLL/GLS fittings
Replacement of miscellaneous items like ceiling rose / pendant holder / terminal etc.
Repl. of electrical equipment
Replacment of lamps in different fitting HPMV/HPSV/LPSV/MLL/Blended lamp/halogen lamp/LED Lamp
Replacement of starter holder/lamp holder
Replacement of lamp holder /connectors in LED/HPMV/HPSV/LPSV/MLL/GLS fittings
Replacement of louvres / diffusers for fluorescent fixture in safe area
Replacement of Perspex cover/protective glass/decorative dome for different fitting and all ratings
Replacement of Toggle Switch complete with connection
Replacement of lamp in aviation fixture
"Replacement of wiring of light / fan point, single phase socket with single core insulated wires up to 6sqmm size"
Replacement of Bakelite sheet (up to 8 Nos switch / socket combination)
Installation of electrical equipment
Installation of ELCB / MCB with connection
Install LED/HPMV/HPSV/MH/MLL/LPS 70/125/150 W NFPF type fixture
Installation of weather proof type fluorescent tube fixture
Installation of control gear box / junction box for HPMV / HPSV lamp 70/125/150W
Installation of high/medium bay type fluorescent tube fixture
Installation of decorative incandescent lamp fixture/CFL
WIRING USING CSNG&CPNG/RIGID PVC CNDT
Installation of flexible conduit(PVC) of all size
WIRING USING METALLIC CNDT
Wiring using metallic conduit irrespective of no. of wire inside.Wires,conduit as FIM's.Screws,grips,saddles under contractor's scope of supply.
Removal of LDB up to 3X12 way-MCB
Removal of LDB up to 3X7way-MCB
Removal of LDB up to 3X6way-MCB
Removal of casing and capping / rigid conduit including wires
Removal of ELCB / MCB with connection
Removal of high/medium bay type fluorescent tube fixture
Removal of Ceiling fan complete with down road including disconnection and wire removal.
REM OF HIGH BAY FIXTURE
Removal of aviation lighting fixture ( single / twin )
Removal of Industrial type lamp fixture
Installation of electrical equipment
Install LED/HPMV/HPSV/MH/MLL/LPS 70/125/150 W FP type fixture
INSTL OF TUBE LIGHT FIXTURE
Installation of miscellaneous electrical equipment's like buzzer / stabilizer etc
Installation of Flame proof / Weather proof aviation fixtures
Installation of control gear box / junction box for HPMV / HPSV lamp 70/125/150W
Miscellaneous Electrical works
Removal of exhaust fan with wall opening
Removal of air circulator
Replacement /installation of MCB box > 6 modules and up to 12 modules
Removal of ceiling fan / wall mounted fans on ceiling hook/wall base frame already fixed.
CONCEALED WIRING WITH 2.5 MM2 PVC WIRE
Concealed wiring job involving circuit wiring for DB, lighting & ceiling fan points on wall/RCC etc. with 2.5 mm2, 650 V grade PVC insulated copper conductor with ISI mark. Colour coding to be used as red,yellow,blue for phases, black for neutral and green for earthing. Each unit length measured consists of a set of 5 lengths of wires (R,Y,B,Black,green)of 1 meter each. Wires/spares/consumables under hurl scope
Installation of ceiling fan / wall mounted fans on ceiling hook/wall base frame already fixed.
Installation of air circulator
Installation of exhaust fan with wall opening already made & payable separately.
Replacement /installation of 5/6 amp switch / socket / plug for decorative lighting accessories
Replacement /installation of 16/32/63 AMP SWTH/SOCKET/PLUG
Replacement /installation of timers
Making wall opening for exhaust fan
Installation of Photocell for light control
Installation of 1 phase energy meter. Detailed scope as per the contract.
Installation & wiring of single phase voltage stabilizer
Installation of Meter Box
Installation of 3 phase energy meter
"Installation of Anchor fasteners with bolt size1/4"" / 3/8"""
Installation of concrete cable route markers as per standard design
Installation of 500 V 63 A (3PH & E) metal clad switch socket/welding socket unit
"Replacement of TPN isolators non-MCB type,125 amp"
"Replacement of TPN isolators non-MCB type,63 Amp"
Replacement of TPN isolators MCB type
"Erection & commissioning of feeder pillar,250 AMPS"
"Erection & commissioning of feeder pillar,125 AMPS"
"Erection & commissioning of feeder pillar,63 AMPS"
Installation of power distribution board
Installation of rod/spike type lightning conductor
INST.OF INDUST.TYP PUSH BUTTON STN-NFLP
INST.OF INDUST.TYP PUSH BUTTON STN-FLP
TEMPORARY CONNECTION OF DEWATERING PUMP
"Replacement of TPN isolators non-MCB type,250 amp"
"Replacement of TPN isolators non-MCB type,400 amp"
"Replacement of TPN isolators non-MCB type,630 amp"
REM.OF INDUST.TYP PUSH BUTTON STN-FLP
REM.OF INDUST.TYP PUSH BUTTON STN-NFLP
FPF-REPAIR OF AVIATION LIGHT FIXTURE
REMOVE TEMP. CONNECT OF DEWATERING PUMP
DEWATERING OF CABLE TRENCH/PIT
MONSOON PROTEC LIGHT JB
MONSOON PROTEC INDUST.LIGHT DB
MONSOON PROTEC INDUS.TYPE POWER SOCKET
INS.INT JN BOX>400X400&<600X600MM NFP/FP
INS.INT JN BOX>600X600MM<900X900MM NFP/FP
INS.INT.JBOX>900X900&<1200X1200MM NFP/FP
INS INT JN BOX>200X200&<400X400MM NFP/FP
REM CAB.CON.EQUP/PNL-6.6/11KV- <=300SQMM
INST INTERM JN BOX <=200X200MM NFP/FP
MONSOON PROT LCS/ GEARBOX/O/L>20-63A
PM OF FLP TPN WELDING SOCKET UPTO 63A
PM OF NFLP TPN WELDING SOCKET UPTO 63A
Installation / connection of earthing wire 8 /12/14 SWG GI wire
INSTL- HRC FUSE 100A
INSTL-GI CLAMP FOR MARSHALLING BOX
INSTL-32SQMM ELMEX CONNECTOR
INSTLNEOPRENE GASKET OF MARSHL BOX
INSTL- MS COVER OF MARSHLING BOX
INSTL -4 WAY MARSHALING BOX
INSTL- LTST.JT KIT1.1KV3.5CX70SQMM
INSTL LTST.JT KIT1.1KV3.5CX35SQMM
INSTL-LTST.JT KIT1.1KV3.5CX25SQMM
INSTL- LTST.JT KIT1.1KV3.5CX16SQMM
INSTL- HRC FUSE 63A
INSTL- HRC FUSE 32A
INSTL- HRC FUSE UP TO 10A
INSTL-FUSE BASE WITH TOP16 AMP
INSTL-.FUSE BASE WITH TOP 32A
INSTL-FUSE BASE WITH TOP 63A
INSTL MCP(120X140X80MM) ON WALL
INST NEW 3/6KEY LOUDOPH POINTS.
INST. SMOKE/HEAT DETECR ON CEILIG
TESTING OF MCPS FOR HEALTHINESS
Testing of MCPs for healthiness in-coordination with Fire Control Room of all safe as well as IS MCPs
ARTISTIC LETTER / PAINTING BOARDS
NAME/NUMBER PAINTING-EQUPT/PIPES
INST CABLE IDENTIFICATION TAG
INST OF LOCAL CONTROL STATION
INST-8 SWG GI WIRE FOR EARTHING
INST-CHECKER PLATE FOR COVER TRENC
Part-B Manpower Supply
SUPERVISOR -1 No
ELECTRICIAN/ FITTER-23 Nos for 12 month (23nos X 27 days X 12 months)
HELPER-23 Nos for 12 month (23nos X 27 days X 12 months)
Bidder Name
Amount in Words
sheema and company
SR ELECTRICALS
SR ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .