Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹27.7 L+₹4,876 (0.18%)Rejected-Finance MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹29.6 L+₹1.9 L (7.01%)Rejected-Finance P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹30.8 L+₹3.1 L (11.3%)Rejected-Finance VILL LAKHOPARA PO GARUBANDHA DISTT SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹32.5 L+₹4.8 L (17.2%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
14 Mar 2023, 6:00 pmClosed
GE MISAMARI
PO-Missamari Dist-Sonitpur Assam
SPECIAL REPAIR TO BLDG NO - T1A (STAFF MESS) AT CSD DEPOT UNDER GE MISSAMARI
2023_MES_580790_1
8345
Open Tender
Civil Works
Item Rate
270 days
GE MISAMARI
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
Yes
GE MISAMARI
₹72,000
Yes
9 Sept 2023
14 Feb 2023
16 Mar 2023
14 Feb 2023
14 Mar 2023
28 Feb 2023
Amount
Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames), complete all as specified and as directed.
Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame), complete all as specified and as directed.
S & F facroty made Second class hard wood kiln seasoned and chemically pressure treated plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as specified and as directed.
S & F 35 mm thick factory made Second class hard wood kiln seasoned and chemically pressure treated Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc, complete all as specified and as directed.
S & F Solid pvc Door Frame of size 100mmx45 mm made out of 5mm wood grain colour PVC Sheet reinforced with MS Square etc, complete all as specified and as directed.
Supplying and fixing in frame at site, factory made solid panel pvc moulded door shutter 28 to 30 mm thick (style) with 2,4,or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified and as directed.
S&F anodised aluminium frame for doors, windows, ventiletors with one or more rebates including joining cleat for fixing etc complete all as specified in cl power coating above aluminium section.(minimum thickness of poweder coating 50 micron), complete all as specified and as directed.
S&F for anodised window/ventiletor shutters, side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips,ruber neoprene packing,anodised aluminium snap beading screws,anodised aluminium fittings such as peg stays 150 mm long(1 no),hinges type-B-21 100 mm long( 2 no) suitable handle 1 no complete all as specified incl power coating of any colour (thick ness of powder coating not less than 50 micron), complete all as specified and as directed.
S&F framed work as in grills, grating etc with end of bars shouldered and or riveted or forged into spikes, framed guard bars, brred iron doors and similar works to fe 290.gde E-150, complete all as specified and as directed.
S & F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sq. M in each pane, complete all as specified and as directed.
Supplyand fixed aluminium wire cloth with 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium stapple complete all as specified and directed.
M&L 18/19 mm thick pre-laminated particle boards exterior grade prelaminated both sides with decoratative choice lamination fixed in alum frame work, complete all as specified and as directed.
M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded granite stone aggregate) as in hold fast, complete all as specified and as directed.
S&F mild steel flat iron of as in hold fast, etc,complete all as specified and as directed.
S & F 100 mm long extruded aluminium alloy with galvanised mild steel Butt hinges and fixed type B-21, complete all as specified and as directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges and fixed, complete all as specified and as directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as specified and as directed.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and as directed.
S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified and as directed.
Supply fix in repairs Harrison rails, mild steel, chromium plated fixed alongwith 2 Nos. of brackets, stops, rollers etc, complete all as specified.
S&F in repairs 10 Ltrs. Capacity PVC flusing cistern low level with all accessories, complete all as specified and as directed.
Supply & Fix in repairs Vitreous EWC size 580 x 440 mm white with includig 'P' or 'S' traps, complete all as specified and as directed.
S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including cutting for and pinning ends of brackets or erecting stand, complete all as specified and as directed.
S &F in repairs Vitreous china urinals, bowl typeflat back size 465 x 355x 265 mm whiten minimum with grating and union for discharge pipe , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, complete all as specified and as directed.
PVC connection pipe 15 mm bore 450 mm long, complete all as specified and as directed.
S&F in repairs brass cromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises, complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surfaces 450x 350x 7 mm thick set and jointed in neat cement slurry & painted in white or colour cement to match incl sreed bed 10 mm thick in CM 1:4, complete all as specified and as directed.
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes.
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes.
Demolition of stone slabs tiles of any description or thickness in floors aprons laid bedded and pointed in any morter etc
M&L for Machine cut kota stone flooring 20-25 mm thick over 20 mm thick cement screed 1:6 base laid and jointed with gey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed.
M&L for Machine cut kota stone 20-25 mm thick over 10 mm thick cement screed 1:4 backing coat in vertical surfaces and jointed with gey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Granite 20mm thick of any type cut beded and jointed with grey cement slurry and pointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete incl 20 MM thick bed 1:6 CM in floors or kitchen slab, complete all as specified and as directed.
M&L for Granite 20mm thick of any type cut beded and jointed with grey cement slurry and pointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete incl 10 mm thick bed 1:4 CM as in vertical surfaces, complete all as specified and as directed.
Demolition of Reinforced cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for Pre-cast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in landing, cover slabs (for manhole covers, drains etc) set in CM 1:6 complete all as specified.
M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, hooking etc binding with mild steel wire not less than 0.90 mm dia (annealed), complete all as specified and as directed.
Demolition of un- reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level)
M&L for 75 mm thick cement concrete as in plinth protection type C-2 1:3:6 (using 40mm graded aggregate) finishing concrete surface even and smooth with using extra cement complete all as specified and directed.
M&L for 100 mm thick cement concrete type B-2 (1:2:4) using 20 mm graded stone aggregate as in path/hardstanding/sub base complete all as specified.
M&L for Pre-polished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors including screed bed in CM 1:4 complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets.
S&F for Anodised aluminium/ GI snap grid power coated framed work of size main runner 39x24.70x0.80 mm, cross tee size 29.x24.70x0.80 mm, wall angle 22.2x22.2x0.65 mm and size of grid 605x605 mm for false ceiling all as specified with 4mm thick GI suspender complete all as specified and as directed.
M & L for 4m thick Non Asbestos designed Cement E board incl two coats of distempering in one side as approved by GE of size fixed in ceiling as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
Demolition of reed lathing single or double including battens and plaster or chicken wire lathing, complete all as specified and as directed.
M&L for GI Wire netting 0.9 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc., in walls, ceilings, stanchions, beams, etc., including all laps, cutting and waste, complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including removal to rubbish complete all as specified and as directed.
M&L for brick work with burnt modular size bricks built in cement mortar 1:6 straight or curved on plan exceeding 6mtr mean radius, complete all as specified and as directed.
M&L for half brick work burnt modular bricks built in cement mortar 1:4 straight or curved on plan exceeding 6mtr mean radius and all as directed.
M&L for 15mm thick plaster on fair faces of brick work or concrete surface in cm (1:4) with wpc @2% by weight face of conc work to wall surface and the surface is finished even and smooth without using extra cement, complete all as specified and as directed.
M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth.
M&L rendering 10mm thick on on otherside of lathing in cement mortar 1:6 be finished fair & even without using extra cement, complete all as specified and as directed.
Supply only Integral water proofing compound
Dismantling plain or corrugated asbestos sheeting any thickness in roof covering.
S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws , complete all as specified and as directed.
S&F pre painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws, complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed in walls, complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) bends of any radius, complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door, complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) Vent Cowl, complete all as specified and as directed.
S&F 50 mm bore sand cast cast iron soil waste in any length with or without ears with cement joints laid in trenches or in floors
S&F 50 mm bore bends any radious with ducks foot or heel rest.
M&L 50 mm bore for cast iron floor trap with grating incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and as directed.
Supply & fix 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store
Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for Refixing or removal to store
Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supply and laying 25 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supply and laying 32 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S & F in repairs 15mm bore angular/ concealed stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified and as directed.
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed.
S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
Taking down/Dismantlinig wrought iron or mild steel work of any description not otherwise proveded for, complete all as specified and as directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates to Fe-290 (Gde E- 165) complete all as specified
Dismantling Unframed timber scantlings 40 Sq. cm and over in section and in any position, complete all as specified and as directed.
M&L 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed.
Dismantling of timber boarding of any description fixed in any position with nails complete all as specified and directed.
S&F 20 mm thick second class hard wood boarding with butt joints clean sawn fixed with nails in any situation (except flooring and skirting) complete all as specified and directed.
Preparation of new or previously treated steel surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of Red Oxide, zinc chorme and applying two coat of synthetic enamel paint, complete all as specified and as directed.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of synthetic enamel paint, complete all as specified and as directed.
Preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of pink primer over applying two coat of synthetic enamel paint, complete all as specified and as directed.
Preparation of old painted wood surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed.
Material & Labour for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface over 1 mm thick wall care putty, complete all as specified and as directed.
M & L for Complete removal of old surface for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface over 1 mm thick wall care putty, complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemper including one coat of chalk whiting on plastered surface to prepara-tory to distempering over 1 mm thick wall care putty, complete all as specified and as directed.
M&L for complete removal of old surfaces of walls and applying two coats of acrylic distemper including one coat of chalk whiting on plastered/putty surface to prepara-tory to distempering over 1 mm thick wall care putty, complete all as specified and as directed.
Dismantling water tanks and removing to store exc 500 & not exc 1000 ltrs, complete all as specified and as directed.
S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed, complete all as specified and as directed.
M & L for Providing and injecting chemical emulsion Anti Termite Treatment of soil under existing floors using chemical emulsion at the rate of One liter per hole, 300 mm apart including drilling and plugging 12 mm dia., holes with cement mortar 1:2 to match existing floors, complete all as specified and as directed.
M & L for Providing and injecting chemical emulsion for Anti Termite Treatment along the external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litres per linear metre including drilling and plugging holes etc., in apron, complete all as specified and as directed.
M & L for Providing and injecting chemical emulsion for Anti Termite Treatment at points of contact of wood work by chemical emulsion (water based solution) at the rate of 0.50 litres per hole by drilling 6 mm dia., holes at a down ward angle, complete all as specified and as directed.
Taking down carefully existing unserviceable copper/ aluminium point wiring (light,call bell, two way, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators,bracket light fittings and making good to the disturbed surface complete all as directed by Engr-in-Charge.
Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified by Engr-in- Charge.
Taking down carefully unsv aluminium submain wiring of any type /loc including conduit /casing and earth wire and making good the distributed surface of walls /ceiling matching with existing finishes all as directed by Engr-in-Charge.
Taking out unsv UG Cable any cross sectional area and connection of any description of any description laying in trenches or fixing with wall or poles all as specified and directed.
M & L for Point wiring with 1.5 Sq mm copper conductor single core FRLSH PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC Casing Caping and its accessories of suitable size, high grade ISI marked in walls /roof and PVC boxes of suitable size including fixing/grouting sunken/ surface as per site requirement for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor FRLSH PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for One light point controlled by one, one way switch 5 Amps
All as per Item No 102 but One ceiling fan / exhaust fan point controlled by one , one way switch and regulator
All as per Item No 102 but One 3 point 5 Amps socket outlets point controlled by one switch on the same board
All as per Item No 102 but One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board
All as per Item No 102 but for one light point controlled by one, two way switch 5 Amps
All as per item No 5 above but with two run of 2.5 sqmm multi stranded Single core copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with one run of FRLSH PVC 2.5 Sqmm multi standard insulated sheathed copper wire as earth continuity conductor along with wiring and connecting to the common earth dolly on independent board.
S & F Switch piano flush type single pole one way 5 Amp, 230 Volts complete all as specified.
S & F Modular switch piano single pole flush type, two way, 6 amps, 230 volts.complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 Amps complete all as specified and directed.
S & F Switch socket combination flush type multipurpose 2/3 pin 5 Amps two in one , 230 volts complete all as specified
S&F Switch socket combination 2 in 1 3 pin, 15 Amp flush type universal.
S&F ceilling rose three terminal surface bakelite type AC 50 Hz 230 Volt of size 65x50mm complete all specified
S & F ceiling fan regulator step type, flush type heavy duty suitable to work on 230 Volt AC supply complete all as specified.
S & F Lamp holder with insulated body, with back plate suitable for batten fittings complete all as directed.
S&F Decorative wall light fixture made up of polycarbonate suitable for 10W LED Lamp complete all as specified.Make- Philips , Model - Comet Wall Light 30575 and equivalent in Havells and Surya.
S & F LED ADORE 10 W B22 CDL 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified.Make-Make- Havells, Cat No: LHLDEUEBML8Z010 or equivalent in CG or Surya.
S&F of Sheet steel enclouser TPN distribution boards, double door factory made 3 phase 415 volts 4 way IP -43 protection ,metal door ,provided with 100 A insulated phase bus bars/neutral bars with shrouds/ earth bars/ sticking saddles/ cement spill protector/ colour coded interconnecting wire set/cable ties /blanking plates and circuit identification lables and 12 outgoing MCBs with a provn for MCB TPN(FP) as incomer and SP MCB as out going .Make : L&T Model-DBTPE004DD and equivalent in Indo Asian and Legrand.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified. Make:- L&T, Model -DBSPN006D and equivalent in Legrand and Indo Asian.
S & F MCB Double Pole 32 Amps 240/415 Volt, confirms to IS/IEC 60898 Breaking Capacity of 10 kA, C-curve, complete all as specified and directed.Make- L&T, Cat No: BB20320C or equivalent in Schinder/ Legrand.
S & F MCB SP, 240 volts, 6-32A Amps 50 Hz ,confirms to IS/IEC 60898 Breaking Capacity of 10 kA, C-curve, complete all as specified and directed. Make -L&T,Model No-BB10060C,BB10100C,BB10160C and equivalent in Schinder/ Legrand.
S & F wall mounted LED 18 watts ,Batten type T 8 light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including Ultra bright LED polycarbonate (T8) tube (Single side connection) 4' x 18 watts with G13 lamp holder complete all as directed by Engineer-in-Charge.Model -REGALBATTENT8UPTO1X18WDSBSWH For Batten Fitting and Model-PHOTONULTRAE2.01213T8SSTL18WLED865SPC For T8 Tubelight ,Make Havells, or equivalent in CG, Surya, all as specifed and directed.
S & F wall mounted LED 10 watts ,Batten type T 5 Mirror light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting ,Make Havells, or equivalent in CG, Surya, all as specifed and directed.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 15/25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete all as directed by Engineer-in-Charge. Make- Havells,Model No - ENDURAPEARLSL15WLED757SASYTOPCMP Or Equivalent in CG and Surya all as specified and directed.
Excavation in trenches n exc 1.50 m wide and n exc 1.50 m depth in soft /loose soil and getting out for lying of cable and errection pipe etc complete all as directed.
Returning, filling in, trenches in soft /loose soil including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as directed.
Removal of excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed.
M & L sand cushioning in trenches for cable protection with coarse sand laid dry in trenches with uniform thickness including consolidation complete all as directed.
Supply & Laying well burnt brick , locally available best quality (sub class "B" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified.
Supply & Laying LT heavy duty UG Cable of size 25 Sqmm 3.5 Core laid in trences /floor/on wall/service connection PVC Insulated, sheathing and armd 1100 Volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed. Make :- Polycab and equivalent in Havells and KEI
S & F GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clam as per site requirement etc all as specified and directed.
Taking down ceiling fan/ Exhaust Fan of any sweep, keeping with safe custody and refixing the same with replacement of unsv core PVC insulated PVC sheathed 3 core multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal over hauling the fan, complete all as specified and as directed.
M&L for replacement Sub main wiring 2 x 6 Sqmm multi-strand FRLSH PVC insulated copper conductor unsheathed cable including concealed conduit and continuous earth wire of FRLSH PVC insulated multi-strand copper conductor of size 6.0 sqmm complete all as specified and directed. Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, check nuts and washers including excavation earth work provisioning of PCC chamber made of PCC 1:3:6 RCC cover funnel with wiremesh 20mm dia watering pipe Medium grade, GI protection pipe 20mm dia bore all as specified in Electrical Plate No.3 of SSR Part I.
MAA CONSTRUCTION
M/S RANA ENGINEERING ENTERPRISE
BEE KAAY TRADERS
MS Awash Ghosh and Brothers
S H ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .