| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | ₹13.2 L | L1 | Accepted-AOC AOC |
| 2 | L2₹13.2 LRejected-Finance | ₹13.2 L | L2 | Rejected-Finance H |
Tender Value
₹13 L
EMD Value
₹1.3 L
Closing Date
28 Mar 2026, 12:00 pmClosed
Executive Engineer P.D. P.W.D. Ballia
Executive Engineer P.D. P.W.D. Ballia
Repair work on the damaged culvert located on the Sikandarpur Pandah road
2026_CEUAZ_1128068_1
1234/4A Date 13.03.2026
Open Tender
Civil Works
30 days
Ballia
Please refer Tender documents.
2 documents required · 2 mandatory
₹945
₹1.3 L
5 Jun 2026
23 Mar 2026
28 Mar 2026
23 Mar 2026
28 Mar 2026
23 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Constn. Of embankment with approved materials obtained from borrow pits with all lifts and leas, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.1 & 300.2As per Technical specification clause 301.5 | |||||
| 2G.S.B.(Granular sub base) for filling in rain cut trenches as per drawing and technical specification | |||||
| 3Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications. | |||||
| 4Demolising RCC work by Mechnical means and stackpilling at designated location and disposal of dismentalled matgerials upto a lead of 1 Km. Stacking serviceable and unserviceable matgerials seperately and including cutting rainforcement bar complete in all respect. S.I. No. 694 | |||||
| 5RCC grade M30 using batching plant transit mixer & concrete pump. | |||||
| 6Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. | |||||
| 7Plain cement concrete M25 nominal mix with crushed stone aggregate 40 mm nominal size mechanically mixed | |||||
| 8Struck cement pointing in 1:2 cement and fine sand mortar complete in all respect. As per MORT&H 13.2-1300 &2200 | |||||
| 9Finishing walls with water proof cement paint. New work two or more coat applied S.I. No. 660+661 | |||||
| 10Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC 67 made of high intensity grade sheeting vide clause 801.3 fixed over alluminium sheeting 1.5mm. Thick supported on a mild steel angle iron post 75mm. X 75mmx6mm. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45x45x60cm. below ground level as per approved drawing. | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.42 MB
Tendernotice_2.pdf
PDF • 1.52 MB
BOQ_2103932.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid