| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.0 CrAccepted-AOC | ₹1.0 Cr | 1 | Accepted-AOC Being Lowest Bidder |
| 2 | 2₹1.1 Cr+₹2.6 L (2.53%)Rejected-Finance | ₹1.1 Cr+₹2.6 L (2.53%) | 2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | 3₹1.1 Cr+₹2.8 L (2.72%)Rejected-Finance H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | ₹1.1 Cr+₹2.8 L (2.72%) | 3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | 4₹1.1 Cr+₹3.7 L (3.57%)Rejected-Finance | ₹1.1 Cr+₹3.7 L (3.57%) | 4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | 5₹1.1 Cr+₹11.5 L (11.2%)Rejected-Finance M S VIJAYA VINAYAKA INFRA DOOR NO 39 33 62 1 4 PLOT NO MIG 95 96 SAMYAM ENCLAVE FLAT NO 101 VUDA COLONY MADHAVADHARA MARRIPALEM VISAKHAPATNAM 530018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | ₹1.1 Cr+₹11.5 L (11.2%) | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
16 Mar 2021, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs to A Wing of Building No. P - 62 at INS Virbahu, Visakhapatnam
2021_MES_420476_1
82120 / E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class B
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹2.2 L
Yes
27 Mar 2021
9 Feb 2021
23 Mar 2021
9 Feb 2021
16 Mar 2021
2 Mar 2021
9 Feb 2021 - 16 Feb 2021
Amount
S & F 20mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F 25mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F 50mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F 75mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F in repairs PP-R Gate Valves [Brass Insert] suitable for 20mm outer dia complete all as specified and as directed.
S & F in repairs PP-R Gate Valves [Brass Insert] suitable for 25mm outer dia complete all as specified and as directed.
S & F in repairs PP-R Gate Valves [Brass Insert] suitable for 75mm outer dia complete all as specified and as directed.
M & L for cutting holes into or through brick walls built in cement mortar and walls of cement concrete and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required for superficial area exceeding 400 Sq.cm and not exceeding 0.10 Sq.m complete all as specified and as directed.
M & L for cutting holes into or through cement concrete slabs, Chajjas, etc. reinforced or otherwise for superficial area exceeding 500 Sq.cm and not exceeding 0.10 Sq.m complete all as specified and as directed.
M & L for cutting holes into or through stone walls built in cement mortar and walls of cement concrete and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required for superficial area exceeding 400 Sq.cm and not exceeding 0.10 Sq.m complete all as specified and as directed.
M & L for cutting holes into or through cement concrete slabs, Chajjas, etc. reinforced or otherwise for superficial area exceeding 250 Sq.cm and not exceeding 500 Sq.cm complete all as specified and as directed.
S & F 150mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes or laid in trenches or in floors or in sunken floors including taking up / down unserviceable / cracked Cast Iron pipe including taking out joints of any type complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes or laid in trenches or in floors or in sunken floors including taking up / down unserviceable / cracked Cast Iron pipe including taking out joints of any type complete all as specified and as directed.
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes or laid in trenches or in floors or in sunken floors including taking up / down unserviceable / cracked Cast Iron pipe including taking out joints of any type complete all as specified and as directed.
S & F 150 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 150 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends [any radius] with duck's foot or heel rest, including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only Integral Water Proofing Compound [ISI marked] of approved make.
M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
S & F Factory made UPVC Sliding Window, Three Track, White Colour of area not exceeding 2.0 Sq.m, made of extruded profiles with wall thickness of 2.3mm±0.2mm, Window profile with hollow section with multi chamber, Frame of size 88mm X 52mm, Sliding Sash of size 42mm X 67mm, Sliding Mesh Sash of size 42mm X 57mm, Sliding Interlock [One vertical length in each shutter] of size 45.50mm X 28mm, Glazing Bead of size 24.50mm X 16mm shall be mitred cut and fusion welded at all corners, including drilling holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM Gasket, 1.2mm±0.2mm thick Galvanized Steel Frame of size 30mmx 18mm, 2 Nos, Sliding Sash of size 30mm x 18mm, Sliding Mesh Sash of size 26mm x 10mm profile to be inserted in required profile, frame shall be fixed to the wall with 8mm X 100mm long fasteners, Hardware such as Touch lock of zinc alloyed [white powder coated], Steel roller system, Stainless Steel Wire Cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories shall be provided with proper operative and locking hardware mechanism, frame shall be fixed to wall with high quality fasteners and silicon glue shall be applied to fill up gap between frame and wall to make leak proof complete all as specified and as per Manufacturer instructions. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.
Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 including Powder Coated Aluminium Channel of size 30 X 12 X 1.5mm for fixing Deco Grill complete all as specified and as directed.
M & L for Making good under Cills [or over arches, lintels and bressummers] including all pinning as necessary complete built in Cement Mortar 1:4 complete all as specified and directed.
M & L for Forming jambs etc to openings with stone supplied by MES including cutting, toothing and properly bonding in to old work including facing and pointing [if necessary] to match existing work, complete built in Cement Mortar 1:4 complete all as specified and directed.
Supply only 5mm thick Tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for Marble Stone Slabs of 18 to 20 mm thick of Green Colour as in Flooring, Treads, Landings of Staircase, Window Cills, Cooking Platform etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, slabs shall be of design / pattern as directed, including inlays, borders, margins, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious joint filler to match the shade of the Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 and grinding & polishing after laying of slabs to mirror polish [Tin Oxide Polish] complete all as specified and as directed. Note: Single stone slab shall be used for entire width of Cills & Landing etc. and joints shall match with the flooring. The edges of Window Cills, Treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves.
M & L for Marble Stone Slabs of 18 to 20 mm thick of Green Colour as in as in Skirting, Dado, Risers of Steps, Jambs, Pillars, Wall Lining [Veneering to Wall] etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, slabs shall be of design / pattern as directed, including inlays, borders, margins, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious joint filler to match the shade of the Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 and grinding & polishing after laying of slabs to mirror polish [Tin Oxide Polish] complete all as specified and as directed. Note: Single stone slab shall be used for entire height of Skirting / Dado / entire width of Risers and joints shall match with the flooring.
M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Sub base for flooring / Levelling course / Padding over roof slabs complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 15mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description including PCC padding of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for Plain / Chequered Cement Concrete Tiles of size 250 X 250 mm / 300 X 300 mm, 25mm thick, Hydraulically pressed as in Floors, set jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 47 above but for One Light Point controlled by Two Nos. of, Two way Switches complete all as specified and as directed.
All as per Serial Item No. 47 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 47 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 47 above but for one SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket, with 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 and including 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 as earth continuity conductor and connecting to earth dolly complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, One Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 4 runs of single core 16 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 16 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 16 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 25 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
S & F in repairs Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F in repairs LAN Outlet, RJ 45, Modular Type, One Module, including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F in repairs Heavy duty PVC Conduit, 20 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable or LAN Cable etc. complete all as specified
S & F MCCB, TP, 100 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCCB, TP, 160 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCCB, TP, 250 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB, SPN, 40 to 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 8 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 6 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB, TP, 63 Amps, 415 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, TP, 100 Amps, 415 Volts, 50 Hz complete all as specified and as directed.
M & L for Taking down Ceiling Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, replacement of Spares such as Capcitor 2.5 Mfd, Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
Taking down Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 Mfd, Bearings, Shaft Bushes, Condenser, Rubber Bushes, Nuts & Bolts etc. and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Aluminium Strip of size 25 X 3 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 25 X 4mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed.
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
Note for Serial Item No. 1 to 91: The work shall be carried out up to [G + 9] Storey Height / 30 Metres height and the rates quoted are deemed to be including providing double scaffolding and safety measures as required and removal of the same on completion complete all as specified and as directed. Nothing shall be paid extra on this account. The building wherein the subject work is to be carried out is under occupation. Accordingly, the subject work shall be carried out under the said condition and the contractor shall take all precautionary measures to avoid inconvenience to the users. The site of work shall be left clean and tidy after day’s work. No obstruction to passage shall be made by dumping materials etc. All the materials obtained from demolition shall be disposed and deposited out of MD land complete all as specified and as directed. Nothing shall be paid extra on this account.
N Sydeswara Rao
lakshmi Engineering Works
RAJESH ENTERPRISES
VIJAY VINAYAKA INFRA
CIVILEC ENGINEERING WORKS
P Govinda Reddy Infrastructure
RAGHU RAMA PANDA
Mahamaruti Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .