Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 CrAccepted-AOC VILLAGE KAITHA POST ITMA NADEE TEER AMARPATAN ROAD SATNA | SATNA | SATNA | MADHYA PRADESH | ₹4.4 Cr Quoted ₹3.7 Cr | L1 | Accepted-AOC Agreement signed |
| 2 | L2₹4.2 Cr+₹48.1 L (13.1%)Rejected-Finance BAANSAGAR COLONY BEHIND BAANSA VILLAGE GOVINDGARH POLICE STATION REWA DISTRICT M P PIN 486550 | REWA | MADHYA PRADESH | 486550 | ₹4.2 Cr+₹48.1 L (13.1%) | L2 | Rejected-Finance L2 |
Tender Value
₹4.4 Cr
EMD Value
₹4.4 L
Closing Date
13 Jan 2026, 6:00 pmClosed
Executive Engineer PWD B and R Division Satna
Executive Engineer PWD B and R Division Satna
CONSTRUCTION OF KHERWASANI DOODI ROAD LENGTH 3.20 KM, UNDER SUB DIVISION MAIHAR.
2025_PWDRB_471643_1
34.04-SATNA-2025-26
Open Tender
Civil Works - Roads
Percentage
180 days
satna
3 documents required · 3 mandatory
₹15,000
₹4.4 L
30 May 2026
31 Dec 2025
15 Jan 2026
1 Jan 2026
13 Jan 2026
1 Jan 2026
Clearing and grubbing road land including uprooting rankvegetation, grass, bushes, shrubs, saplings and trees girth up to 300mm, removal of stumps of trees cut earlier and disposal ofunserviceable materials and stacking of serviceable material to beused or auctioned up to a lead of 1000 metres including removal anddisposal of top organic soil not exceeding 150 mm in thickness A) In area of light jungle
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead up to 1000 meters. (i) Lime /Cement Concrete B) Cement Concrete Grade M-15 & M-20
(ix) Removing all type of Hume pipes and stacking within a lead of 1000 meters including earthwork and dismantling of masonry works. C) Above 900 mm
Scarifying existing bituminous surface to a depth of 50 mm by mechanical means Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead up to 1000 meters.
Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling Serviceable material at designated locations and disposal of unserviceable materials up to a lead of 1000 meters,
Excavation in Soil using Hydraulic Excavator and Tippers with disposal up to 1000 meters. Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting suitable earth to the embankment location and disposing off unsuitable earth with all lifts and lead up to 1000m as per relevant clauses of section-300 of specification.
Construction of Embankment with Material Deposited from Roadway Cutting Construction of embankment with approved materials having CBR>7 deposited at site from roadway cutting and excavation from drain or foundation of structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevant clauses of section-300.
Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site,spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.
Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications ii) For 37.5 mm maximum size
Wet Mix Macadam Providing, laying, spreading and compacting graded stoneaggregate to wet mix macadam specification includingpremixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13 and as per clause of section 406 of specifications. A) By Sensor Paver
Deduction for item No.4.3 if sensor paver is not used
Prime coat Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.75 kg/sqm using mechanical means as per clause 502 of specifications.
Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications. (II) @0.30 kg per sqm (dry & hungry bituminous surfaces/granular surfaces treated with primer)
Bituminous Macadam Providing and laying bituminous macadam using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with Electronic Sensor paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction and as per clause 504 of specifications. a) Using Batch Mix Plant of appropriate capacity and Hydraustatic Paver finisher with Sensor. (ii) for Grading II (19 mm nominal size) bitumen content 3.5% with bitumen 60/70 (VG 30)
Open - Graded Premix Surfacing Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tone capacity, finished to required level and grades all complete as per clause 510 of specification. (i) Case - I: Mechanical method using Penetration grade Bitumen VG 30 and HMP of appropriate capacity not less than 75 tones/hour.
Seal Coat Providing and laying seal coat, sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats, all complete as per clause 511 of Specification. (ii) Case - II: Type B (Providing and laying of premix sand seal coat using HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm sieve and retained to 180-micron sieve) and penetration bitumen VG 30 of suitable grade all complete as per clause 511 of specification.
Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc (ii) Ordinary Kilometer stone (Precast)
Hectometer stone ( Precast) ( 0.2 Km Stone)
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT &H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. iv) 60 cm equilateral triangle
x) 80 cm x 60 cm rectangular
xii) 60 cm x 45 cm rectangular
xiii) 60 cm x 60 cm square
Surface Drains in Soil Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions to the requirement of clause 301 and 309. Suitable Excavated material to be used in embankment within a lead of 50 meters as per relevant clauses of section-300.
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beeds on Concrete surface. Providing and applying (Cleaning of concrete surface and after applying Concrete primer) thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35 along with concrete primer. The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. Note: - The guarantee of Thermoplastic should be minimum 3 Years.
Direction and Place Identification signs more than 0.9 sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC:67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thickskins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8of the IRC 67-2012 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 100 x100 x 3mm Square Pipe of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25x50x1.25mm tubular frame with the help of suitable sizes pop rivettes of 6mm or by the help of G I / Nickle Chome plated nut & bolts to be hammered after tightening. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor.
Providing and laying reinforced cement concrete pipe NP-4 for service ducts below concrete pavement. a) 300 mm Dia
b) 600 mm Dia
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade or drainage layer w ith coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver finisher with electronic sensor, compacting with 8- 10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect
Deduct from Item No.6.1 above if paver finisher with electronic sensor is not used and laying, (The acceptance criteria regarding level, thickness, surface regularity, texture finish, strength of concrete and all other quality control measures shall be the same as in case of machine laid work.)
Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement with M-30 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with electronic sensor slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc. including groove cutting for width of 4 mm- 6mm and 1/3rd depth of PQC within 8-10 hrs of placing/ finishing of PQC Including cost of cutting including cleaning of groove and providing approved sealant filling etc. as per clause 602.2.10 and 600.10 and IRC-57-2006 as per drawing and as per specification.
Deduct from Item No.6.3 & 6.4 above if slip form paver with electronic sensor is not used and laying, compaction is done by fix form paver having 60 mm vibratory needle @ 2 Nos. per metre. (The acceptance criteria regarding level, thickness, surface regularity, texture finish, strength of concrete and all other quality control measures shall be the same as in case of machine laid work.)
Providing and fixing Steel in dowel bar and tie rod including craddle, laps etc. complete required as per design. (b) Tor steel confirming to IS: 1786:2008
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in I) Ordinary soil (including back filling with approved material) (i) Depth upto 3 m
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in II) Ordinary rock (not requiring blasting) (ii) 3 m to 6 m depth
Add extra as follows in the rates of the above items if dewatering is resorted to A) upto 3 m depth (50% extra)
Add extra as follows in the rates of the above items if dewatering is resorted to b) beyond 3 m to 6 m depth (75% extra)
PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.
Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.
Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. (b) 1000mm Dia Pipe
Laying Reinforced Cement Concrete Pipe NP 4 /prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4 /prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in double rowincluding fixing collar with cement mortar 1:2 but excluding excavation, protection works,backfilling, concrete and masonry works in head walls and parapets. (b) 1000mm Dia Pipe
Taking, exploratory boring 100mm dia at the location of piers and abutments or for high embankments in approaches in all types of strata as per IRC-78-1983 and section 2400 of pecifications a) Upto 1.0 m below bed level
Taking, exploratory boring 100mm dia at the location of piers and abutments or for high embankments in approaches in all types of strata as per IRC-78-1983 and section 2400 of pecifications b) Beyond 1.0 m depth upto 5.0 m
Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
Providing & Filling Annular Space Around Footing in Rock upto top of rock with Lean cement concrete M-15 nominal mix in foundation 1.5 m in soft rock and 0.60 m in hard rock with crushed stone aggregate 40 mm nominal size and as per relevant clauses of sections 1500, 1700 and 2100.
Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with. (i) With Batching Plant, (Pan Type or Twin Shaft type) Transit Mixer and Concrete Pump B) PCC Grade M20
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600. FE 500D/FE 550/FE 550D
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications B) PCC Grade M20 With Batching Plant, (Pan Type or Twin Shaft type)Transit Mixer and Concrete Pump
Supplying, fitting and placing HYSD bar einforcement in sub- structure complete as per drawing and technical specifications and as per relevant clause of section 1600. FE 500
Providing weep holes in Brick asonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78. A Granular material
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided behind entire surface after abutment, return wall and wing wall to the full height compacted to a firm condition complete as per drawing and technical specification.
Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398.
Providing and Placing Reinforced/Prestressed cement concrete in super structure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in C) RCC Grade M 30 (ii) For Cast in Situ RCC T beam and slab 1 Height up to 5 m
Supplying, fitting and placing HYSD bars einforcement in super- structure complete as per confirming to IS 1786:2000 drawing and technical specifications as per relevant clauses of section 1600 FE 500
Providing and laying Cement concrete wearing coat 75 mm thick with M-30 grade concrete with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 19 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with static paver, spread, compacted and finished with power trowel in a continuous operation including provision of admixtures as approved, curing compound, finishing to lines and grades as per drawing but including cost of steel etc. including reinforcement, texuring with texuring brush complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications.
Drainage Spouts complete as per MOST standard drawing and Technical specification and as per clause 2705 of specifications.
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification and as per relevant clauses of section 1700.
Reinforced Cement Concrete Crash Barrier Providing of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MoRT&H circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified.
Reinforced cement concrete non-structural approach slab (Grade of concrete M 30) as per MOST standard drawing including reinforcement and formwork complete as per drawing and Technical specification and as per relevant clauses of section 1500, 1600, 1700 and clause 2704 of specifications.
Filler Joint (ii) Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
Filler Joint iii) Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications.
Filler Joint iv) Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight
Testing of span of bridge for deflection due to live load with platforms for loading arrangements apparatus for measurement including unloading etc. complete as per approved drawing
Providing and fixing in position Marble Plates of size 0.9 m. x 1.2 m. with inscribed details as per detailed drawings.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
TenDoc.pdf
Tender Documents • 34.23 MB
OtherDoc.pdf
Other Document • 0.01 MB
BOQ_555109.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .