| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC 37 A MURGI MAHAL SADAR BAZAR PO BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | BARRACKPORE | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹42.9 L+₹3.8 L (9.60%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹44.3 L+₹5.1 L (13.0%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹44.5 L+₹5.3 L (13.5%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹45.9 L+₹6.7 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹38.2 L
EMD Value
₹76,460
Closing Date
4 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata 700120
PROVN/ MODIFICATION OF AUDIOMETRY ROOM IN BLDG NO. B-1 OPD COMPLEX AT BH AND PROVN OF WP AMN SHED WITH HARD STANDING AND 01 X STATIC WATER TANK (5000 LTRS) AT CENTRAL MAGAZINE AT BARRACKPORE UNDER GE BARRACKPORE
2023_MES_603072_1
8778/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹76,460
Yes
26 Jul 2023
13 Jun 2023
6 Jul 2023
13 Jun 2023
4 Jul 2023
27 Jun 2023
Amount
PART-I Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
Bringing approved earth filling, earth obtained from out side of Defence land to a distance exceeding 5.00 Km but not exceeding distance 15 Km and depositing where directed and spreading and levelling in layers not exceeding 25 cm thick complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 25mm thick damp proof course to horizontal surface including necessary form work in cement concrete (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole, landings cover slab for manhole, chullah hoods, chajjas, water through, managers, shelves and similar articles set in cement mortar (1:6) complete all as specified and directed. (NOTE: Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor and reinforcement shall be measured and paid Separately.)
M&L for cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
S&F of solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing as mentioned in SSR Part-II (2020), Section 8, Page No.180 complete all as specified and directed.
S&F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No.180 complete all as specified and directed.
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 140mm) complete all as specified and directed.
S&F of mortice lock, brass vertical type of size 100mm with 4 levers complete all as specified and directed.
S&F of 125 mm long butt hinges, extruded brass, with mild steel hinge pin, bright pol?ished and fixed, type B-11 complete all as specified and directed.
S&Fof 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of aluminium extuded body door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg as fixed complete all as specified and directed.
S&F of 40 mm thick flush door shutters (factory made) solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
S&F of second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints etc complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of rolled mild steel roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410W (Gde E-250) quality 'B' complete all as specified and directed.
Supply only MS round bars 10mm dia for securing chain link fencing fixed to RCC fencing posts as per Fe-410-W (Gde- E-250) quality 'A' or Fe-290 (Gde E-165) complete all as spcrified and directed.
Supply only MS galvanised iron chain link fencing any size and type complete all as specified and directed.
Fixing only galvanised iron chain link fencing including line wires, any mesh, size and type to any type of standards, rails, staining bolts, etc. and fixed with 10 mm dia MS round bars and straining including provision of binding wire for securing chain link fencing as per relevant IS specification and as approved complete all as specified and directed. (Note: 10 mm dia MS round bar shall be measured and paid separately under Item No. as "supply only")
S & F of mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed..
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 12mm thick gypsum board (Make: Everest, type/pattern -oceanic or equivalent of Armstrong/Charminar) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base of floor complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base of foot path/ paving complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc finished even and smooth without using extra cement complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4 type B0 as in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection & floor including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 20mm thick screed bed of cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 18mm-20mm thick granite (any type) work (table rubbed and polished) machine cut in steps, jambs, pillars, window cill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) as screed bed complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 350 mmX7 mm thick or equivalent set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:3) complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) laying complete all as specified and directed.
M&L for 80mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-40 grade) laying complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with cement mortar (1:4) mixing with mixed with WPC @200ml per 50 Kg of cement or as per manufacturer's instructions , finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
S&F of 6mm thick figured glass pin headed type and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkaline resistant primer after preparation of new surfaces of ceiling complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on newly plastered surface of wall after and including preparation of surfaces complete all as specified and directed.
M&L for applying two coats of acrylic exterior emulsion paint over a coat of acrylic primer on old pastered wall surfaces as directed by GE as per site condition after and including complete removal of existing treatment and preparation of surfaces using smart painting technic complete all as specified and directed .
M&L for applying one coat of synthetic enamel paint (1st grade quality) after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
S&F of 15mm dia bib tap, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F of 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
Audiometry Two room setup (9x6feet)& (9x5.9 Feet):- Side Paneling : GI galvanized iron box panel frame work of 24 gauge perforated to an extent of 70% and of 4" thick box panels of (8'x1') in dimension. The panels with 4"(100MM) thick box panel should have infill acoustic material density varies from 32 & 16kg/cum (glass wool as acoustic material). The Material should have the ability to attain 50% insertion loss and attenuate incident sound energy from frequencies that are concentrated in the 125 to 8000 hertz range to meet the ANSI standards. The external surface having cladded with noise reduction coefficiqent rated fabric & the encapsulated panels will be secured to floor with mild steel track frame work made up of 16 gauge of U channel approx size (20mm x 55mm x 40mm) and fasteners complete. Material standard: GI Sheet Specs: JSW/JINDAL/TATA Alloyed coating containing zinc and about 55 % aluminium. ● Products have heat resistance and heat reflection property of aluminium in addition to corrosion resistance of zinc and aluminium. ● Surface is attractive white silver. MS(Mild Steel) JSW/JINDAL/TATA Appropriate framework to be made & powder coated to 0.80- 0.90 micron. Glass wool Spec: Twiga/ Rockwool/Insul. Its would be FR rated & with appropriate NRC as specified.
Ceiling Panelling : Ditto all as per item above, but for ceiling having mild steel angle frame work (16 gauge mild steel powder coated L angle 50 x 50mm in size) to support the ceiling panel . Material standard: GI Sheet Specs: JSW/JINDAL/TATA Alloyed coating containing zinc and about 55 % aluminium. ● Products have heat resistance and heat reflection property of aluminium in addition to corrosion resistance of zinc and aluminium. ● Surface is attractive white silver. MS(Mild Steel) JSW/JINDAL/TATA Appropriate thickness & framework to be made. Powder coated to 0.80-0.90 micron. Glass wool Spec: Twiga/ Rockwool/Insul. Its would be FR rated & with appropriate NRC as specified.
Floor: 5mm thick loop pile carpet, the material attenuates the low frequency waves 125 to 4k Hz and less interference from low frequency sound.Material Standards Carpet: Loop Pile of 10mm thick ISO 4919:2012
Door Frame: Door frame made up to 19mm & 24mm thick plywood box type size approx (50mm x 300mm) with infill of acoustic material, cladded with a layer of foam and 3 mm thick fabric. The groove to facilitate perfect sealing of the door shutter Door: Door shutter made up of 12mm thick plywood (double layer) insulated internally and externally with foam and covered 3mm fabric. The rate includes suitable door handle, lock and necessary hardware Note:: Double doors and single door frameworks constitute this requirement. Material Standards Clas 1 / ISO/TC 218:2007 / wooden batten ISO 12465:2002 best in class: with anti-termite & marine proof. Glass wool Spec: Twiga/ Rockwool/ tranquil/Insul. Its would be FR rated & with appropriate NRC as specified. STC 45
Observation window: Comprising of double layers 8mm thick glass with the inside glass being placed at an angle of 45 degrees. If desired. This is secured to a wooden frame work with rubber gaskets and silica gel. Material Standards Clas 1/ ISO/TC 218:2007 / wooden batten ISO 12465:2002 best in class: with anti-termite & marine proof. Glass: toughened with lamination, thickness as per STC 45
JACK PANEL; Appropriate socket and jack pins will be provided as per the compatibility of audiometer based on your requirement. Please inform well in advance the compatible jacks (stereo / mono /AV pins) Material Standards ISO/TS 10303A
LED light fixture: 12 watts LED white light Material Standards: ISO 9001
Center Partition Wall: Double layered gypsum of 12 mm with GI frame work and insulated with glass wool. Material Standards: ISO 6308:1980 Glass wool Spec: Twiga/ Rockwool/ tranquil/Insul. Its would be FR rated & with appropriate NRC as specified. STC 45 GI Sheet Specs: JSW/JINDAL/TATA Alloyed coating containing zinc and about 55 % aluminium.
PART-II (INTERNAL ELECTRIFICATION) Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One ceiling fan/exhaust fan point controlled by one switch and one regulator.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One bell/buzzer point controlled by one bell push.
One light point controlled by two 2 way switch.
All as per Item No.67.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
All as per Item No.67.00 here-in-before but point wiring with 4sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4.00 sqmm for One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board complete all as specified and directed .
S&F of modular switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 2 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular bell push 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular red colour lighting indicator 6 Amps, single pole, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular socket shuttered type 10 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular socket 6/16 Amps, 6 pin combined shutter socket, 2/3 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F of ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F of call bell, AC, 230 Volts single pole, multi music type ISI marked complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of round shape LED light fitting with LED lamps 1X12 watts, 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holder, LED lamp suitable for roof ceiling and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of required size complete all as specified and directed.
S&F of LED light fitting 2X16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F of flame proof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F for switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F for 70/75 watt LED secruity light fitting, with LED lamps in aluminium PDC housing, toughened glass cover with IP66 protection with minimum 4kv inbuilt surge protector and cable connection from looping box to light fitting and testing complete all as specified and directed . (Make:- Bajaj Cat No. BRTFG 75W LED I/Havells cat No.ENDURACITYLINERNEOSL70WLED757PASYBOTG /Crompton Greaves as approved or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of recess mounting 2'x2' LED 34/36 Watt light fittings with LED lamp and required driver, slim in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout modular ceiling grid and also can be suspended with provided kit and necessary electric connection with and including required size three coat sheathed flexible copper conductor cable from looping box to light fitting and testing complete all as specified and directed. (Make: Bajaj Cat No. BCTBLR 36W LED FP CW/Crompton Greaves Cat No.LCTLSNE-36-F0-CDL/ Havells Cat No.PLUTOSURFACE4X1PLS34WLED857S / Philips Cat No. RC 380B LED36S 6500 G4 L60 W60 PSU ODOC or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface complete all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way / L&T Cat No. DBTPN004GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / L&T Cat No.DBSPN008GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 4 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way /L&T Cat No. DBSPN004GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F of MCB, SPN, 32 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
S&F of MCB, FP, 40 to 63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
S&F of MCB, FP, 63 to 100 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed. {Note : (i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate}.
S&F of flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after).
M&L for 50mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for test point termination block made of gun metal or phospherous bronze size 75mmX75mmX25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw complete all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required).
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x .75mm laid dry flat complete all as specified and directed.
Supply and laying for GI pipe 40 mm "Medium grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed.
S&F of air termination single pointed copper Rod 20mm dia of 1.0 mtrs long shall be fixed by using support pipe of 600mm long GI 40mm dia medium grade, lower end of support pipe shall be fitted on MS base plate 150 x 150x 6mm thick grouted on top surface of bldg of any height and making necessary PCC block 1:3:6 type C-2 using 40mm graded stone aggregate, including necessary from work for casting of PCC blocks for placing and mounting of air termination rods and connecting & jointing of air termination rod duly connected with down/horizontal conductor with suitable nuts, bolts, washer etc and top end of support pipe to be plugged and all as specified and directed.
Supply, installation, commissioning and testing split type wall mounted air conditioner (indoor & outdoor unit with cordless remote control unit) of capacity not less than 1.5 TR, BEE 5 Star rating, fitted with rotary compressor (5 years warranty), refrigerant type R-410A/R-32, cooling capacity not less than 5100 watts/17400 BTU/hr, PVC FRLS grade multi stranded copper conductor cable 4 core 2.5 sqmm for connection with outdoor unit, clamps, nuts, bolts, washers, drilling holes on wall/ceiling for connection/drain pipes including power coated bracket for outdoor unit (one set) and making good the disturbed surfaces of wall/ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. (Note: PVC drain pipe of suitable size & heavy duty copper connection pipes including suitable insulation upto 3mtrs are deemed to be included in above quoted rate).
Supply, installation & commissioning single phase voltage stabilizer digital type naturally air cool indoor type and designed for input variation between 170 Volt to 250 Volt with output voltage stabilize at 230 Volts with accuracy of + 2.5 % of 5 KVA rating complete all as specified and as directed.
M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground after complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed or any other indicated situation for loop earthing etc as required 20x4 mm GI strip complete all as specified and directed.
M&L for earthing with galvanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers with galvanised iron strips of size 32 x 6 as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Note: Galvanised iron strip of size 32x6mm upto 7.5m long including testing is deemed to be included with quoted rate)
M&L for earthing with galvanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
PART-III (FURNITURE) Supply of 'L' type wooden table with storage cabinet made with first class teak hard wood as per specification/ user reqirement with minimum knots, of size:- Top size: one side 6'x3' and other side 5' x 2.5' height 2.5', thickness 1.5", leg to be provided 3" x 3" square shaped, rail size 4" x 1.5", stiffener to be provided all aound the legs. All surfaces to be smoothened with sand paper and glossy finesh polished complete all as specified and as directed. (Drawing No.- TP)
Supply of couch examination with cushion and modified with wooden storage cabinet with three steps as per sample/ user requirement complete all as specified and directed. (Drawing No.- FD-122M))
Supply of chair visitors stainless steel with cushion complete all as specified and directed. (Make:- Methodex Model No. V-29 V2 NS or equivalent model of make Nilkamal/ Geeken)
Supply of chair executive with arms complete all as specified and directed. (Make:- Nikamal Model No. Neal Revolving Chair or equivalent model of make Geeken/ Methodex) (Note for item No. 111.00 to 114.00:- Bidders quoted their rates after visit BSO subdivision for the sample of furniture.)
M/S. ARUP KUMAR DEY
N C DUTTA
RISING ENTERPRISE
DE CONSTRUCTION CO
SHANKAR CONSTRUCTION CO
PIONEER TRADING
KOLAY CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .