| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC C 234 ADG P CHENNAI | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹41.3 L+₹1.7 L (4.38%)Rejected-Finance PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹43.7 L+₹4.1 L (10.5%)Rejected-Finance RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹79,700
Closing Date
30 Oct 2021, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_479551_1
GE MAINT EZHIMALA 8430
Open Tender
Civil Works
Item Rate
180 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹79,700
Yes
13 Nov 2021
4 Oct 2021
1 Nov 2021
4 Oct 2021
30 Oct 2021
18 Oct 2021
5 Oct 2021 - 12 Oct 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing)/ removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for screed bed or bedding layer of cement mortar 1:6, 20mm thick for laying floor finishes complete all as specified and as directed.
M&L for 10 mm thick rendering on faces of brick/concrete surface in cement mortar 1:4 surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for Glazed ceramic tiles 7 to 8 mm thick (Square / rectangular ) area of each tile exc 0.06 sqm but n. exc. 0.11 sqm on vertical surfaces such as skirting dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for granite (of any type) tile 20 mm thick machine cut, bedded and jointed with white cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
Rounding to edge of stone slabs one edge ,such as in steps, cooking platform, and other similar situation complete all as specified and as directed.
Taking down of cement plaster of any description or thickness / chipping of cement concrete in any situation from brick or concrete surface including raking out of joints, hacking for key scrubbing down with water to received new plaster complete all as specified and as directed.
M&L for rendering on fair faces of brick work or concrete surfaces 10mm thick in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering on fair faces of brick work or concrete surfaces 10 mm thick in CM 1:3 in ceiling finished even and smooth without using extra cement but using water proofing compound complete all as specified and as directed.
M&L for preparation of new plastered surface and applying two coats of acrylic emulsion paint (interior grade) on wall over a coat of acrylic primer all as specified and as per manufacturer's instructions.
M&L for preparation of new plastered surface and applying three coats of white wash all as specified and as per manufacturer's instructions.
M&L for preparation of old treated surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
M&L for preparation of old treated surfaces and applying one coat of acrylic emulsion paint (interior grade) on wall all as specified and as per manufacturer's instructions.
S&F GI framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similiar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for cutting holes into or through brick walls built in stone walls, built in cement mortar or cement lime mortar and walls of cement concrete, superficial area not exc 150 sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed.
M&L for applying two coats of OBD emulsion over a coat of primer on newly plastered surface including preperation complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/ dense soil complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate ) as in foundations, filling and mass concrete complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 Grade St-240 for square or rectangular tube complete all as specified and as directed.
S&F GI Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment (Fe-410W, Gde E-250, Qlty-B) including necessary cutting in wall complete all as specified and as directed.
S&F MS anchor fasteners of size 12mm dia and 100mm length for fixing the plates to the wall surface complete all as specified and as directed.
M&L for cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement complete all as specified and as directed.
M&L for providing cement concrete in roof kerbs or mud stops, rounded or chamfered on edges, type B0, 1:2:4 using 12.5 mm graded aggregate complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for finishing walls with Acrylic Smooth exterior paint of required shade, new work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed.
M&L for preparation of old treated surfaces and applying one coat of acrylic emulsion paint (exterior grade) on wall all as specified and as per manufacture's instructions.
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated/tile pattern steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, and not exceeding 10 sqm on plan for foundation, etc. and getting out in hard/dense soil complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for laterite stone walling of regular coursed , well bonded , bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
Returning, filling in trenches and inside plinth, including spreading, leveling, watering and well ramming in layers n.exc 25cm complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M&L for rendering 15mm thick on stone masonry surfaces in cement mortar 1:4 and finish the surface even and smooth complete all as specified and as directed.
M&L for cement concrete 1:1½:3 type B-1 (using 20 mm graded stone aggregate ) as in foundation for machineries, plants etc complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken boulders or stones complete all as specified and as directed.
M&L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for cement concrete 100mm thick type B-1, 1:2:4 (20mm graded aggregate) finished surface even and smooth without using extra cement complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2,75mm thick for plinth protection and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for forming construction joint 30mm deep x 10mm wide filledwith sealing compound - Grade 'B' complete all as specified and as directed.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new /old surfaces complete all as specified and as directed.
M&L for Point wiring complete as specified with 1100 volt grade confirming to IS 694, 1.5sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor drawn through and including instove enamild steel conduit of suitable size but not less than 20mm dia , with all fittings, fixed on wall/ceiling /floor including fixing of rotary switches and duly earthed with same cable as for point wiring above but green in colour as continuous earthing wire complete all as specified & directed by Engineer-in-Chrage. (a) One light/ point controlled by one rotary switch. Notes:- (i) Necessary instove enamild steel conduit junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED tube light fitting 1 x16W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, recommeded for Gas / vapour group of IIA & IIB and zone 1&2 IP 65protected etc. complete with all accessories prewired and including connecting up with three core 1.5Sqmm FRLS copper coductor complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing FLP-WP , Flame proof MCB distribution board for fixing of suitable MCB SPN / TPN, LM-6, IP-66 including suitable lenth of instove enamild steel conduit and junction boxes etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing FLP-WP, Flame proof switch fuse unit with MCCB 63Amps, LM-6, IP-66 including suitable lenth of instove enamild steel conduit and junction boxes etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing FLP-WP, Flame proof switch fuse unit with MCCB 32Amps, LM-6, IP-66 including suitable lenth of instove enamild steel conduit and junction boxes etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing FLP-WP, Flame proof switch fuse unit with MCCB 16Amps, LM-6, IP-66 including suitable lenth of instove enamild steel conduit and junction boxes etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing FLP-WP, Flame proof switch fuse unit with MCB 10Amps, LM-6, IP-66 including suitable lenth of instove enamild steel conduit and junction boxes etc complete all as specified and directed by Engineer-in-Charge.
Supply and spreading river sand / riddle earth for cushioning and covering of the UG cable in trenches complete all as specifed and directed by Engneer-in-Charge. Note:- Punned thickness shall be measured for payment purpose.
Supply and laying PCC un reinforced cable cover of size 250 mmx 150mmx40mm , class LV type I flat for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 150 sqmm 3.5core complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of multi criteria detectors with base for below for false ceiling model FAPT 851B501 including taking down old unserviceable complete all as specified and directed by Engineer-in-Charge. Make:- Honey well or equivalent as approved by GE.
Supply and fixing fire extingusher portable 4.5 Kg CO2 type as per IS 2878 complete all as specified and directed by Engineer-in-Charge.
Supply and fix pressure type DCP Fire extinguisher 6 KG capacity with ISI mark including taking out old one and stand etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix AFFF fire extinguisher 9 Litre capacity with ISI mark including taking out old one and stand etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 sqmm, 4 Core complete all as specified and directed by Engineer-in-Charge.
Gates Infra Construction Co
SANDR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .