Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹52.2 L
EMD Value
₹1.0 L
Closing Date
13 May 2022, 4:00 pmClosed
Executive Engineer
STD GANDERBAL
SITC OF ACB LT AND HIGH MASS LIGHTS AT CENTRAL UNIVERSITY KASHMIR CAMPUS TULLAMULLA GANDERBAL
2022_PDD_166429_1
STDGBL 01 OF 2022-23 DATED 11-04-2022
Open Tender
Electrical Works
Item Rate
30 days
Tullamulla Ganderbal
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
Yes
EXECUTIVE ENGINEER
₹1.0 L
Yes
23 May 2022
11 Apr 2022
14 May 2022
11 Apr 2022
13 May 2022
11 Apr 2022
11 Apr 2022 - 13 May 2022
Amount
SITC OF ACB, LT AND HIGHMASS LIGHTS AT CENTRAL UNIVERSITY KASHMIR CAMPUS TULLAMULLA GANDERBAL
SITC of (1+1) set scheme 2000A, 4-Pole MDO type Air-circuit conformance IS/IEC-60947 (part-1,2) standard with 75-85KA Breaking capacity Microprocessor based Release Parameter, Mannual and automatic spring charge system,O LED Display builtin, variable current setting from 25-100% in at least 4-steps, under voltage, over-voltage, over current, Neutral, Phase failure etc protections inbuilt with assocaited relays, fire sensor with hooter and LED displays announciation system. (the set is be accomodated in metal enclosures of 12 SWG sheet metal duly powder coated and epoxy/plastic paint having various chambers/cutouts for switch gears and cables ducts etc as per BIS standards with individual chambers and doors with locking arrrangements, the cabinet should have xtra channel metal reinforcement at bottom and corners to bear the overall load of switch gear. The pannels includes control wiring interface with contactors MCB's etc, high precision type digital voltameters and amphere meters with ASS,VSS and allied accessories, etc. The Cabinet should be provided with 2000A Tinned Copper Bus capacity with seperate chambers as per requirement, the cutout should be provided holes for different size of Cable gland cut outs with individual chambers. (make Schneider, Siemens, L&T, ABB) (All ACB's and MCCB's should be accommodated in single cabnet with seperation in Bus-Bars). The 4 No. of ACB's is to be accomodated in single cabnet with 1 main and 1 feeder (outgoing) in 2 sets.
SITC of 630A 4-Pole 50KA MCCB's with allied accessories within the ACB Pannel. (make Schneider, Siemens, L&T, ABB)
SITC of 400A 4-pole 50 KA MCCB's with allied accessories within the ACB Pannel. (make Schneider, Siemens, L&T, ABB)
SITC of 250A 4-pole 50 KA MCCB's with allied accessories within the ACB Pannel. (make Schneider, Siemens, L&T, ABB)
SITC of 125A 4-Pole 35 KA MCCB's with allied accessories within the ACB Pannel. (make Schneider, Siemens, L&T, ABB)
SLTC of Single core 630 Sq.mm XLPE 1.1 KV H-4 Grade Aluminium Armoured cable IS-8130-84 including terminations with lugs at ends, Cables to be laid in underground in proper size HDPE pipe and to be routed on Perforated GI Cable trays with supports of angle or channel frames as per desired or directions by site incharge, all cable should be routed in metal ties with proper spaces as per REC standard and should be terminated with Pad clamps/Lugs of suitable sizes at each end. The cables includes spare lenghts at each circuit duly routed from source to load end
SLTC of Single core 185 Sq.mm XLPE 1.1 KV H-4 Grade Aluminium Armoured cable IS-8130-84 including terminations with lugs at ends, Cables to be laid in underground in proper size HDPE pipe and to be routed on Perforated GI Cable trays with supports of angle or channel frames as per desired or directions by site incharge, all cable should be routed in metal ties with proper spaces as per REC standard and should be terminated with Pad clamps/Lugs of suitable sizes at each end. The cables includes spare lenghts at each circuit duly routed from source to load end
SLTC of 3.5 -Core 150 Sq.mm Power cables of 1.1KV grade with FRLS PVC inner and outer sheath aluminium armoured cables including terminations with Lugs/Clamps as per requirement, All cables to be laid in underground in suitable size HDPE pipe by way of mannual excavation and backfills or to be routed along the walls supports etc in suitable clamps etc:
SLTC of 3.5 -Core 185 Sq.mm Power cables of 1.1KV grade with FRLS PVC inner and outer sheath aluminium armoured cables including terminations with Lugs/Clamps as per requirement, All cables to be laid in underground in suitable size HDPE pipe by way of mannual excavation and backfills or to be routed along the walls supports etc in suitable clamps etc
SLTC of 4 core 240 Sq.mm Power cables of 1.1KV grade with FRLS PVC inner and outer sheath aluminium armoured cables including terminations with Lugs/Clamps as per requirement, All cables to be laid in underground in suitable size HDPE pipe by way of mannual excavation and backfills or to be routed along the walls supports etc in suitable clamps etc
SLTC of 3.5 -Core 25 Sq.mm Power cables of 1.1KV grade with FRLS PVC inner and outer sheath aluminium armoured cables including terminations with Lugs/Clamps as per requirement, All cables to be laid in underground in suitable size HDPE pipe by way of mannual excavation and backfills or to be routed along the walls supports etc in suitable clamps etc
SLTC of 3-Core 16 Sq.mm Power cables of 1.1KV grade with FRLS PVC inner and outer sheath aluminium armoured cables including terminations with Lugs/Clamps as per requirement, All cables to be laid in underground in suitable size HDPE pipe by way of mannual excavation and backfills or to be routed along the walls supports etc in suitable clamps etc
SLTC of 8-Core 2.5 Sq.mm control cables of 1.1KV grade with FRLS PVC inner and outer sheath copper armoured cables including terminations with Lugs/Clamps as per requirement, All cables to be laid in underground in suitable size HDPE pipe by way of mannual excavation and backfills or to be routed along the walls supports etc in suitable clamps etc
SLTC of 12-core 2.5 Sq.mm control cables of 1.1KV grade with FRLS PVC inner and outer sheath copper armoured cables including terminations with Lugs/Clamps as per requirement, All cables to be laid in underground in suitable size HDPE pipe by way of mannual excavation and backfills or to be routed along the walls supports etc in suitable clamps etc
SLTC of 1-core 10 sq.mm copper flexible cable Power cables of 1.1KV grade with FRLS PVC inner and outer sheath aluminium armoured cables including terminations with Lugs/Clamps as per requirement, All cables to be laid in underground in suitable size HDPE pipe by way of mannual excavation and backfills or to be routed along the walls supports etc in suitable clamps etc
SFTC of GI Perforated Cable trays 1 feet wide 10 feet long with allied accessories i.e GI nuts and bolts channels etc and necessary fabrication as per requirement.
Proving and fixing of steel made cable ties for routing of 630A XLPE cable on perforated cable trays.
SFTC of Bi-metallic Al-Brs Pad clamps of 630A capacity including fabrication as per requirement
SFT of Single core 630 Sq.mm Metallic Cable glands Suitable for following sizes of cables.
SFT of Single core 180 Sq.mm Metallic Cable glands Suitable for following sizes of cables.
SFT of (b) 4-Core 150 Sq.mm Metallic Cable glands Suitable for following sizes of cables.
SFT of 4-Core 180 Sq.mm Metallic Cable glands Suitable for following sizes of cables.
SFT of (d) 3-Core 25 Sq.mm Metallic Cable glands Suitable for following sizes of cables.
Supply and errection of 11 meter long ST Pole (ST-410 SP56), including 100x50x6mm GI Channel iron Cross arm 7 ft long and GI angle iron braces of 65x6mm 7 ft long brace duly fabricated, GI clamps, Nuts and bolts, Cement bottoming of pole of 0.6cum. concrete/pole, pin insulators/shackle insulators with clamps 3 No.s each pole, Earthing with earthing rod, anti-climbing device, danger plate and painting of pole each pole etc. complet job.
Supply and laying of ACSR 0.05 Conductor including necessary terminations at required points.
SITC of 16 meter long High mast poly gonal GI poles Hot Dip (polygonal contineously tappered telescopicllay joint as per Bs-5135 or IS equalent), avg thickness of GI coating as per IS-4759-1984, IS-2629-1985, IS-2633-1972, with lightening protection of GI spike with earthing provision, wind speed and other bearing loads as per IS 875 Part-3-1987 and TR-7, 2000 of ILE, Foundaton and grouting type as per IS-456, 875 part-3-1987 and TR-7, 2000 of ILE with eight no. of GI bolts with allied accessories. Double drum winch for lowering and raising to ligt load with allied accessories as per IS-809, stainless steel rope 6mm flexible without having any joint. The Light mounting top of Hight mast pole must accomodate at least 15 lights with cable support as per IS standards
Providing and laying of concrete foundation for High mast pole including earth work excavation upto 8 feet deep and 3x3 feet sides of 1:3:6 mix RCC Block with 14kg TMT bars of 10mm as RCC work) complete job
SITC of LED Street lights of60 Watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on existing poles or new poles including necessary fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.)
SITC of LED Street lights of120 Watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on existing poles or new poles including necessary fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.)
SITC of LED Street lights of 150 Watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on existing poles or new poles including necessary fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.)
SITC of LED Street lights of 200 Watt IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on existing poles or new poles including necessary fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.)
Providing and fixing of Pole boxes on High mast poles with allied accessories to accommodate MCB's etc of 14 SWG Powder coated paint, Earthing Bar, weather proof design, IP-65 Protected body, locking arrangement and cable cut-outs of desired sizes etc.
SFTC of D-curve/type 2A MCB 10KA MCB including cable/wire terminations as per requirement for LED lights and ACDB's (Schneider, ABB, siemens, legrand.)
SFTC ofC-Curve/type 6A MCB. 10KA MCB including cable/wire terminations as per requirement for LED lights and ACDB's (Schneider, ABB, siemens, legrand.
SFTC of C-curve/type 10A-64A MCB. 10KA MCB including cable/wire terminations as per requirement for LED lights and ACDB's (Schneider, ABB, siemens, legrand.
SFTC of C-curve/type 4-pole 63A MCB 10KA MCB including cable/wire terminations as per requirement for LED lights and ACDB's (Schneider, ABB, siemens, legrand.
SITC of ACDB of TPN 28-Way 16SWG powder coated following ways with in-built copper bus bars for 4-wire system and earth,IP-65 protected textured double door type with proper locking sytem, to be fixed in walls with surface leveling by way of chiseling the wall including minor masonary works after completion, the job includes terminations of wire as per requirement.
SITC of ACDB of TPN 24-Way 16SWG powder coated following ways with in-built copper bus bars for 4-wire system and earth,IP-65 protected textured double door type with proper locking sytem, to be fixed in walls with surface leveling by way of chiseling the wall including minor masonary works after completion, the job includes terminations of wire as per requirement
Providing, Laying, Testing and commissioning of 1.5 Sq.mm FRLS PVC single core multi-stranded flexible copper cable in PVC conduits in surface/recessed for repairing/replacing of existing damaged/new cables from various terminations points for making various circuits funcational. the job includes dismantling/modification of existing circuits. ( the circuits inclues phase, neutral and earth all together for a circuit)
Providing, Laying, Testing and commissioning of 2.5 Sq.mm FRLS PVC single core multi-stranded flexible copper cable in PVC conduits in surface/recessed for repairing/replacing of existing damaged/new cables from various terminations points for making various circuits funcational. the job includes dismantling/modification of existing circuits. ( the circuits inclues phase, neutral and earth all together for a circuit)
Providing, Laying, Testing and commissioning of 4.0 Sq.mm FRLS PVC single core multi-stranded flexible copper cable in PVC conduits in surface/recessed for repairing/replacing of existing damaged/new cables from various terminations points for making various circuits funcational. the job includes dismantling/modification of existing circuits. ( the circuits inclues phase, neutral and earth all together for a circuit)
Providing, Laying, Testing and commissioning of 6.0 Sq.mm FRLS PVC single core multi-stranded flexible copper cable in PVC conduits in surface/recessed for repairing/replacing of existing damaged/new cables from various terminations points for making various circuits funcational. the job includes dismantling/modification of existing circuits. ( the circuits inclues phase, neutral and earth all together for a circuit)
Re-allignment of 7 No. of power cables of 150-300 sq.mm from existing termination point to ACB pannel by way of shifting including laying the cable on new installed cable trays and their terminations as required. The job includes fixing items i.e cable ties, clamps, saddles etc.
Supply and fixing of 25 KG C02 cylinder with trolly and allied accessories protective equipments/items for SOP's within the control room building including testing and commissioning, the equipment/items must be of REC standard or as per the instructions of site incharge.
Supply and fixing of 9 KG DCP cylinder with allied accessories protective equipments/items for SOP's within the control room building including testing and commissioning, the equipment/items must be of REC standard or as per the instructions of site incharge.
Supply and fixing of Rubber mats 3x6 feet size protective equipments/items for SOP's within the control room building including testing and commissioning, the equipment/items must be of REC standard or as per the instructions of site incharge.
SITC of metal clad 14 Swg kiosk/Distribution pannel out door type for cable termination point of size, 3x3x1 feet powder type IP-65 Protected pannel with inbuilt bus-bars of current capacity 400 A each of 4-wire sytem. The pannel must contain individual chambers with doors, cut-outs for cables, 4-No. of 65x6mm angle iron legs as per requirement and standards. The pannel legs is to be fixed in cement concrete of 1:2:4 mix of 0.5 cums underground.
Providing and fixing of maintanence free chemical earthing including digging/drilling of 3 mtrs/10 ft deep pit in hard/semi hard soil, chemical material and laying of pipe electrode with external dia of 80 mm and internal strip of 50x6mm GI make with back fill compound 50 kg in the pit and disposal of unwanted material from earthing site to disposal site, and earthing should provide desrible earth resistance value as per IS standards
Construction of cement concerete inspection Pit/Main holes atleast 1.5'x 1.5'x 9"(LBH) above the earth installations with main hole cover of GI/Hard plastic assembly and cavity to be filled with glass wool complete job.
Oil Topping of 1MVA Existing Transformer upto desired level including rectification of leakage if any.
Providing and laying of 25x3 mm GI strip to be fixed in clamps, nut bolts, saddles, etc including cutting, bending, drilling, welding as desired for earth terminations.
SITC of 33KV Gantry structure as per REC standard, drawing and design of GI angle iron (95x95x6mm, 75x75x6mm, 65x65x6mm and 50x50x6mm with GI nuts and bolts) including fabrication of angle (cutting, bending, welding, drilling etc complete job) by attaching the fabrication with exisiting structural gantry including dismantling of 33KV switch gears, equipments from existing gantry and shifting and installation of these dismantled equipments on new gantry structure complete job.
Providing and laying of concrete foundation for 33KV gantry structure including earth work excavation upto 8 feet deep and 3x3 feet sides of 1:3:6 mix RCC Block with 14kg TMT bars of 10mm as RCC work) with foundations bolts weights about 2kg per bolt ( for each gantry 4-no. of GI bolts to be provided as fastener of angle iron tempete) the gantry structure includes vertical and horzontal structural beams. complete job
SITC of 33KV Polymer disc insulator with fitting suitable for 0.15 ACSR Electrical Accessories at 33KV Gantry structures for creation of common buses and terminations for equipment structures complete job.
SITC of 33KV Polymer Pin insulator Electrical Accessories at 33KV Gantry structures for creation of common buses and terminations for equipment structures complete job.
SITC of PG Clamps suitable for 0.15 ACSR Electrical Accessories at 33KV Gantry structures for creation of common buses and terminations for equipment structures complete job.
SITC of T-Clamps suitable for 0.15 ACSR Electrical Accessories at 33KV Gantry structures for creation of common buses and terminations for equipment structures complete job.
SITC of metal clad 14 Swg AC Distribution pannel I door type for cable termination point of size, 3x3x1 feet powder type IP-65 Protected pannel with inbuilt bus-bars of current capacity 400 A each of 4-wire sytem. The pannel must contain individual chambers with doors, cut-outs for cables, -wall mounted type powder coated having individual chambers for incomming and out going switching controls as per drawing and directions by concerbed engineer incharge and as per requirement and standards. The pannel must be having cut outs for MCCB's and MCB's for power distribution of UPS including cable cut outs as desired locations including cable end terminations complete.
SFTC of 250A 4-pole 50 KA MCB & MCCB's including cable/wire terminations as per requirement for UPS ACDB's (Schneider, ABB, siemens, legrand make.)
SFTC of C-curve/type 10A-64A MCB. 10KA MCCB's including cable/wire terminations as per requirement for UPS ACDB's (Schneider, ABB, siemens, legrand make.)
SFTC of C-curve/type 4-pole 63A MCB 10KA MCCB's including cable/wire terminations as per requirement for UPS ACDB's (Schneider, ABB, siemens, legrand make.) C-curve/type 4-pole 63A MCB 10KA
SFTC of C-curve/type 4-pole 63A MCB 10KAACSR conductor 0.15 wolf MCCB's including cable/wire terminations as per requirement for UPS ACDB's (Schneider, ABB, siemens, legrand make.)
M/S RB POWER SOLOTIONS
SHEIKH ELECTRICALS
M/S WATT ELECTRICALS CONTRACTORS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .