Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.2 LAccepted-AOC | ₹55.2 L | L1 | Accepted-AOC Being L1 accepted. |
| 2 | L2₹58.0 L+₹2.8 L (5.03%)Rejected-Finance | ₹58.0 L+₹2.8 L (5.03%) | L2 | Rejected-Finance Being L2 Rejected. |
| 3 | L3₹59.9 L+₹4.7 L (8.50%)Rejected-Finance | ₹59.9 L+₹4.7 L (8.50%) | L3 | Rejected-Finance Being L3 Rejected. |
| 4 | L4₹60.4 L+₹5.2 L (9.47%)Rejected-Finance EWS 38 ROAD NO 03 KPHB COLONY HYDERABAD 500072 | MEDCHAL MALKAJGIRI | TELANGANA | 500072 | ₹60.4 L+₹5.2 L (9.47%) | L4 | Rejected-Finance Being L4 Rejected. |
| 5 | L5₹62.4 L+₹7.2 L (13.1%)Rejected-Finance | ₹62.4 L+₹7.2 L (13.1%) | L5 | Rejected-Finance Being L5 Rejected. |
Tender Value
₹67.2 L
EMD Value
₹1.3 L
Closing Date
1 Sept 2023, 6:00 pmClosed
S Gopal Krishna
O/o GM(CIC), Begumpet Airport, Hyderabad.
Augmentation of water supply at Begumpet Airport Residential Colony, Hyderabad.
2023_AAI_164012_1
AAI/HYD/ENGG(C)/W-02/2023-24
Open Tender
Civil Works
Item Rate
120 days
Begumpet Airport, Hyderabad.
As per NIT.
12 documents required · 12 mandatory
₹1,180
₹1.3 L
2 Apr 2024
11 Aug 2023
4 Sept 2023
12 Aug 2023
1 Sept 2023
12 Aug 2023
12 Aug 2023 - 18 Aug 2023
Amount
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc, not exceeding 80 mm dia.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :bituminous road
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall: 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall: 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall: 40 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall: 50 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 40 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 80 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 25 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required: 40 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required: 50 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required: 80 mm nominal bore
Geologist survey for identification of ground water available location for Boring/drilling bore well of required depth by suitable method as per directions of Engineering in charge.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 6 1/2" (165mm)Bore. Upto 30Mtrs.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 6 1/2" (165mm)Bore. Upto 30Mtrs.From 31 to 60M
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 6 1/2" (165mm)Bore. Upto 30Mtrs.From 61 to 90M
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 6 1/2" (165mm)Bore. Upto 30Mtrs.From 91 to 120M
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 6 1/2" (165mm)Bore. Upto 30Mtrs.From 121 to 150M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 250 mm (10 ") nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 165 mm (7 ") nominal size dia
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :50 mm dia
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :80 mm dia
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm nominal bore Horizontal
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm nominal bore Vertical
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :20 mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :25 mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :40 mm diameter pipe
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :50 mm diameter pipe
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and filling with coarse sand allroung G.I pipes in external work as per the directions of Engineer in charge .20 mm to 80mm nominal diameter pipe
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall: 80 mm dia nominal bore
Supply and installation of following Stainless Steel borewell Submercible pumpsets with motor along with suitable capacity starter & NRV for new bore drilling of 6 1/2"at various areas of Airport i/c bore covers, nippals/reducers/unions etc. as per the site requirement , suitable for operation on 415 V, 50 Hz 3-Phase supply complete as required. a) Minimum 12.5 HP/22 Stage, 50mm outlet with minimum discharge of 195 LPM at 135 Mtr head, stainless steel impeller, casing and shaft etc., fully automatic S/D starter
Supply and installation of following Stainless Steel borewell Submercible pumpsets with motor along with suitable capacity starter & NRV for new bore drilling of 6 1/2"at various areas of Airport i/c bore covers, nippals/reducers/unions etc. as per the site requirement , suitable for operation on 415 V, 50 Hz 3-Phase supply complete as required. b) Minimum 10 HP/20 Stage, 50mm outlet with minimum discharge of 195 LPM at 108 Mtr head, stainless steel housing and shaft etc., fully automatic S/D starter
Supply and installation of following Stainless Steel borewell Submercible pumpsets with motor along with suitable capacity starter & NRV for new bore drilling of 6 1/2"at various areas of Airport i/c bore covers, nippals/reducers/unions etc. as per the site requirement , suitable for operation on 415 V, 50 Hz 3-Phase supply complete as required. c) Minimum 5 HP/22 Stage, 38mm outlet with minimum discharge of 90 LPM at 91 Mtr head, stainless steel impeller, casing and shaft etc., DOL starter
Supply and installation of following size 16 kg/cm2 pressure density PE 100 grade HDPE pipes in the bore well for delivery of submercible pump with all connections and required accessories i/c cutting, threading, Heat shrinking etc. as pplicable complete as required. a) 50 mm Dia.
Supply and installation of following size 16 kg/cm2 pressure density PE 100 grade HDPE pipes in the bore well for delivery of submercible pump with all connections and required accessories i/c cutting, threading, Heat shrinking etc. as pplicable complete as required. b) 40 mm Dia.
Supply and laying of following size copper conductor weather proof submersible flat cable in the existing borewell confirming to IS:694 with upto date ammendments etc. complete as required. a) 3 X 4 Sq.mm.
Supply and laying of following size copper conductor weather proof submersible flat cable in the existing borewell confirming to IS:694 with upto date ammendments etc. complete as required. b)3 X 2.5 Sq.mm.
Supply of following size XLPE insulated, PVC sheathed aluminium conductor armoured power cable of 1.1KV grade confirming to IS 7098 (Part I) 1978 with upto date amendments etc as required. a) 4 X 25 Sq.mm
Supply of following size XLPE insulated, PVC sheathed aluminium conductor armoured power cable of 1.1KV grade confirming to IS 7098 (Part I) 1978 with upto date amendments etc as required. b) 4 X 16 Sq.mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories conforming to IS 14930, Part II etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a) 50 mm dia (OD-50 mm & ID-38 mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required. a) Upto 35 sq. mm
Excavation of the cable trenches in hard rock/any type of roads, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. a) 50 mm dia
SUYAMBU PROJECTS
Srinivas Gannamaneni
MAHALAKSHMI CONSTRUCTIONS
Yogesh builders
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .