| 1 | L1₹7.7 CrAdmitted-Finance | ₹7.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹7.8 Cr+₹9.9 L (1.30%)Admitted-Finance N A | PALWAL | HARYANA | 121004 | ₹7.8 Cr+₹9.9 L (1.30%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical A 127 SHIVAM VIHAR RAJPUR ROAD JAKHAN DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical bid is non responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical bid is non responsive |
| 5 | Rejected-Technical 11 NARENDRA VIHAR BALLUPUR ROAD DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical bid is non responsive |
| Sl No | Description | Qty | Unit | M/s Mahalaxmi Construction L2 | COMBINED PROMOTORS AND INFRASTRUCTURES (P) LTD L1 |
|---|---|---|---|---|---|
| 1.00CIVIL WORK | |||||
| 2.00Structure Work | |||||
| 3.00Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | |||||
| 4.00 | All kind of soil | 2,335.23 | Cum | 225 ₹5,25,426.75 | 221 ₹5,16,085.83 Lowest |
| 5.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 2,335.23 | Cum | 196 ₹4,57,705.08 | 192 ₹4,48,364.16 Lowest |
| 6.00 | Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials. | 934.09 | Cum | 71.5 ₹66,787.44 Lowest | 79 ₹73,793.11 |
| 7.00All kinds of soil | |||||
| 8.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | |||||
| 9.00 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) | 84.57 | Cum. | 5,169 ₹4,37,142.33 | 5,076 ₹4,29,277.32 Lowest |
| 10.00Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. | |||||
Tender Value
₹7.9 Cr
EMD Value
₹15.9 L
Closing Date
2 Nov 2021, 3:00 pmClosed
GM CIVIL
BRIDCUL Avasthapna Bhavan, 583-TH, Oppo. Govt ITI, Niranjanpur, Majra Saharanpur Road, Dehradun-248001
Construction of 30 bedded urban community health center, bhupatwala Haridwar, Uttarakhand.
2021_BRID2_37373_1
1644/BRIDCUL/736/2021 Dated 08.10.2021
Open Tender
Civil Works - Buildings
Item Rate
540 days
Bhoopatwala Haridwar
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
MD - BRIDCUL
₹15.9 L
BRIDCUL Dehradun
20 Nov 2021
13 Oct 2021
2 Nov 2021
13 Oct 2021
2 Nov 2021
22 Oct 2021
21 Oct 2021
Amount
CIVIL WORK
Structure Work
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kind of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
25 mm thick
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls
Under 20 cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick Work
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Door /Window ( Wood Works )
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete :
150x125x27x5 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Steel Works
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B
Fixing with adjustable lugs with split end tail to each jamb
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
4 mm thick glass panes
Providing and fixing of metal false ceiling using 0.50 mm thick metal lay in plain tegular tile size 600 x600 mm and armstrong 24 mm Prelude 38 frame work including main tee 3000 mm , 1200 mm and 600 mm cross tee , GI wall angle complete with all acessories ( Grid size 600 x 600 mm)
Suply and fixing of Gypsum board step false ceiling using 12.50 mm thick saint gobin gyproc board plain and saint gobin gyproc ultra frame work including GI ceiling section 3660 mm , GI intermediate channel 3660 mm , GI perimeter 3660 mm , GI L- hanger 3660 mm etc complete with jointing and finishing (without painting)
Flooring Works
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm or300x600mm (satin Finish)
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Finishing Works
12 mm cement plaster of mix :
1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix:
1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge.
Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Waterproofing Works
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at jointsof PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works upto plinth level
All works above plinth level
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
12 mm cement plaster of mix :
1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix:
1:6 (1 cement: 6 coarse sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of ngineer-in-charge.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete :
150x125x27x5 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B
Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing soil, waste and vent pipes: Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
Providing & filling the tee /bend /collar/tapper etc., with rubber jount filler including all complete
Providing and fixing plain bend of required degree.100 mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing double equal plain invert branch of required degree:100x100x100x100 mm Sand cast iron S&S as per IS 3989
Providing and fixing plain bend of required degree.75 mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing double equal plain invert branch of required degree:75x75x75x75 mm Sand cast iron S&S as per IS - 3989
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron(100 mm)
Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm
Bend 87.5° 110 mm bend
Shoe (Plain) 110 mm Shoe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
20 mm dia nominal bore
25 mm dia nominal bore
Sanitary Fixture & Fittings
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink with drain board
(For Janitor & Oth. areas) 510x1040 mm bowl depth 200mm.
Providing & fixing P.V.C waste pipe for sink or wash basin including PVC waste fittings complete .
Flexible pipe
40 mm dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing
Rectangular shape 453x357 mm
Rectangular shape 1500x450 m
Providing and fixing toilet paper holder.
C.P brass
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
White Agaria Marble Stone
Providing & fixing uplasticised PVC connection pipe with brass unions.
45 cm length
15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
15 mm nominal bore
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap( PUSH TYPE)
Sanitary Fixture & Fittings
Providing and fixing bib cock of approved quality : Providing and fixing brass bib cock of approved quality(Jaguar/Parryware) :15 mm nominal bore(Push type as per approval of E-in CHARGE)
Providing and fixing C.P. brass angle cock/ valve for basin mixer , geyser points or to other similar fittings of approved quality conforming to IS:8931(Jaguar/Parryware) :15 mm nominal bore(Push type as per approval of E-in CHARGE
Providing and fixing C.P. brass Pillar cock of approved quality in wash basin or other fittings as per requirement conforming to IS:8931(Parryware/Jaguar) :15 mm nominal bore(Push type as per approval of E-in CHARGE)
Soil, Waste, Vent Water Pipes
Providing and fixing cast brass Floor Clean Out plug with suitable insert keys for opening, male threaded joint with G.I. socket lead caulked to soil pipe / waste pipe of C.I. and C.I.(LA) pipe as required complete as per instruction of the Engineer in charge.
100mm dia
Providing and fixing Floor Drain as per requirement
100 mm x 50 mm
Providing and fixing Floor trap P type/ S type as per requirement complete with GI hopper etc.
100mm dia
For Handicapped Toilet
Supply,Installation,Testing & Commissioning .of 2 Nos. support arms and backrest to mount at fixed height for handicap toilet as required.
Supply,Installation,Testing & Commissioning .of raised toilet seat with cover for handicap toilet.(Make Parryware/Jaguar or approved by Engineer in charge)
SITC in position of adjustable type white vitreous china wash basin for handicapped complete with tracks(IR 4360-Commander or equivalent) with C.I./M.S. brackets painted white, 32 mm C.P. brass waste, C.P. brass chain with rubber plug, 32mm dia C.P. cast brass bottle with extension piece, wall flanges and union complete including cutting and making good the walls floors wherever required.
Supply,Installation,Testing & Commissioning .of 35 mm dia powder coated steel grab L-SHAPED CORNER RAIL(800MM+800MM) (for handicapped toilet).
Providing and fixing of Health Foucet complete with all accessories including divertor, angle valve etc required for for complete successful commissioning.
Earth work in excavation by mechanical means ( hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sq.m on plan ) including disposal of excavated earth, lead upto 50 m and lift upto 1.50 m, disposed earth to be levelled and neatly dressed. All kinds of soil.
Providing and laying in cement concrte 1:4:8(1cement :4fine sand:08graded brick aggregated 40mm .nominal size.) and curing complete excluding cost of form work in foundation and floors.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
40 mm. thick cement concrete flooring 1 :2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. nominal size ) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.
15mm thick plaster on the rough side of mix 1:3 ( 1 cement : 6 fine sand )mortar.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Earth work in excavation by mechanical means ( hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sq.m on plan ) including disposal of excavated earth, lead upto 50 m and lift upto 1.50 m, disposed earth to be levelled and neatly dressed. All kinds of soil.
Providing and laying in cement concrte 1:4:8(1cement :4fine sand:08graded brick aggregated 40mm .nominal size.) and curing complete excluding cost of form work in foundation and floors.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing units of reinforced cement concrte 1:1.5:3(1cement :1.5 coarse sand:3graded stone aggregate 20mm.nomnal size) of strength not less than M-150 in lintels and band over door and windows excluding supply of reinforcement and its bending including
Reinforcement for R.C.C work including straighting, cutting, bending , placing in position and bending all complete Thermo-Mechanically Treated bars.
40 mm. thick cement concrete flooring 1 :2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. nominal size ) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.
15mm thick plaster on the rough side of mix 1:3 ( 1 cement : 6 fine sand )mortar.
Providing & fixing of R.C.C manhole covering tank (600 x 600)
Providing & fixing of foot rest in tank
Suspended floors, roofs, landings, balconies and access platform
DRAIN
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Pipes, cables etc, not exceeding 80 mm dia.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for therm 110 mm diameteral expansion, (i) Single socketed pipes.110 mm diameter
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Coupler
Bend 87.5 degree
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
150 mm diameter S.W. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.6
G.I.PIPE
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc
15 mm dia nominal bore
20 mm dia nominal bore
25 mm nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
G.I.UNION
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
STOP COCK
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
BALL VLAVE
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore
NON-RETURN VALVE
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
25 mm nominal bore (Horizontal)
TERRACE TANK
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suppor
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (20% of excavation earth)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Mild steel and Medium Tensile steel bars.
Centring and shuttering including strutting,ropping etc. and removal of form for
Suspended floors, roofs, landings, balconies and access platform.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix
1:3 (1 cement : 3 fine sand)
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate.
Providing and fixing in position precast R.C.C. manhole cover and frame of requiredRectangular shape 600x450mm internal dimensions
Providing and fixing plain bend of required degree Inlet Pipe 100 mm dia
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc, not exceeding 80 mm dia.
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter :
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, totalweight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
ELECTRICAL WORK
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group c
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, LED Fixtures, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
GROUP C
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays bends with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
100 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays tees with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fabricating and installing following size of perforated pre painted M.S. cable trays cross members with perforation not more than 17.5%, in convenient sections, joints with connectors, suspended from the ceiling with M.S. suspenders including bolt & nuts, painting suspenders as required.
150 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/existing open trence/as required.
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface and overhead as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
2 X 10 sq. mm (19mm)
3½ X 35 sq. mm (32mm)
3½ X 95 sq. mm (38mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (45mm)
4 X 10 sq. mm (25mm)
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
40 mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.
100 mm dia
150 mm dia
Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 120 sq. mm
Supplying & making of INDOOR cable end terminations with HEAT SHRINKABLE JOINTING KIT with all accessories including lugs suitable for following sizes of 3 core, XLPE Al conductor cable of 11 KV grade as required.
3 X120 sq mm.
Supplying & making of OUTDOOR cable end terminations with HEAT SHRINKABLE JOINTING KIT with all accessories including lugs suitable for following sizes of 3 core, XLPE Al conductor cable of 11 KV grade as required.
3 X120 sq mm.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required
150 mm dia
Supply, installation, testing and commissioning of following ennealed tinned electric grade copper conductor PVC insulated and PVC sheathed jelly filled armoured telecommunication cable as per specifications.
5 pair armoured riser cable of 0.60 mm dia copper conductor
10 pair armoured riser cable of 0.60 mm dia copper conductor
20 pair armoured riser cable of 0.60 mm dia copper conductor
50 pair armoured riser cable of 0.60 mm dia copper conductor
Supply and installation, testing and commissioning following size KRONE make telephone tag block in lockable 16 gauge sheet medium duity PVC enclosure complete as required.
5 pair Krone type tag block
10 pair Krone type tag block
20 pair Krone type tag block
50 pair Krone type tag block
Supply of 20 Watt LED Linear Metal Construction commercial batten fitting with fuse protection suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for both surface & suspended Mounting, complete in all respect 2000 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side of existing MS pipe (in case of hanging )complete accessories all respect and as directed by engineer in charge.,
Supply of LED indoor surface downlighter suitable for general lighting. Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification.The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of approx 2000 lumens and maximum system wattage of 18 Watts.power factor >0.95 , THD <10%. he fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameter
Supply of Downlighter 12 watt/1200 lumens suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for recessed Mounting, complete in all respect 1200 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side of existing MS pipe (in case of hanging )complete accessories all respect and as directed by engineer in charge.
Supply of 2' * 2' panel light 30 watt/3600 lumens suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for recessed Mounting, complete in all respect 3600 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side of existing MS pipe (in case of hanging )complete accessories all respect and as directed by engineer in charge.,
Supply of Mirror Light 10 watt/1150 lumens suitable for Polycarbonate diffuser & aluminium heat sink complete suitable for Surface Mounting, complete in all respect 1150 system lumens PF>0.95, THD<10%, CRI>80, Sheet Thickness 0.8mm, Average Life 40000hrs @L70 with fixing clamps, nut, bolts and fixing arrangement with both side of existing MS pipe (in case of hanging )complete accessories all respect and as directed by engineer in charge.,
Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required, in case of rode length exceed more that 30 cm then fixing clamps, nut, bolts and fixing arrangement with both side in existing steel conduit/MS pipe as directed by engineer in charge.
Supply of Exhaust fan 300 mm sweep metal body with 50 HZ 230 volt ac complete with all respective accessories.
PANEL-1 Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & indoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. Make: Legrand(Adlec) or eqivalent as per approved make list and as direction by engneer in charge.
INCOMER: TRANSFORMER
1 nos. 630A 415V, Ics=Icu=Icw=50KA, 4P MCCB with MP release with LCD display having O/L, S/C , G/F Over temperature and neutral failure protection, release should have minimum 10 Nos fault history for diagnosis of fault, Make: Legrand (DMX)/ Schneider (Masterpact ) /Siemens (3WL), L&T Upower omega.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 630/5A. Make : Legrand/ Siemens/ Schneider/L&T
1 Set of phase indicating lamp with MCB
INCOMER: 250 KVA DG SET
1 nos. 400A 415V, Ics=Icu=Icw=50KA, 4P MCCB with MP release with LCD display having O/L, S/C , G/F Over temperature and neutral failure protection, release should have minimum 10 Nos fault history for diagnosis of fault, Make: Legrand (DMX)/ Schneider (Masterpact ) /Siemens (3WL), L&T Upower omega.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 400/5A. Make : Legrand/ Siemens/ Schneider/L&T
1 Set of phase indicating lamp with MCB
INCOMER: 125 KVA DG SET
1 nos. 250A 415V, Ics=Icu=Icw=50KA, 4P MCCB with MP release with LCD display having O/L, S/C , G/F Over temperature and neutral failure protection, release should have minimum 10 Nos fault history for diagnosis of fault, Make: Legrand (DMX)/ Schneider (Masterpact ) /Siemens (3WL), L&T Upower omega.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 250/5A. Make : Legrand/ Siemens/ Schneider/L&T
1 Set of phase indicating lamp with MCB
BUS COUPLER
1 nos. 630A 415V, Ics=Icu=Icw=50KA, 4P MCCB with MP release with LCD display having O/L, S/C , G/F Over temperature and neutral failure protection, release should have minimum 10 Nos fault history for diagnosis of fault, Make: Legrand (DMX)/ Schneider (Masterpact ) /Siemens (3WL), L&T Upower omega.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 630/5A. Make : Legrand/ Siemens/ Schneider/L&T
1 Set of phase indicating lamp with MCB
BUSBAR
800 A TPN Bus bar of aluminimum alloy.
OUTGOING
1 nos. 400 A, 415V, FP MCCB of 50 kA.with adjustable O/L and S/C protection. Make: Legrand (DPX3)/ Schneider (Compact NSX) /Siemens (3VL)/L&T
2 nos. 200 A, 415V, FP MCCB of 36kA.with adjustable O/L and S/C protection. Make: Legrand (DPX3)/ Schneider (Compact NSX) /Siemens (3VL)/L&T
4 nos. 160 A, 415V, FP MCCB of 36kA.with adjustable O/L and S/C protection. Make: Legrand (DPX3)/ Schneider (Compact NSX) /Siemens (3VL)/L&T
6 nos. 100 A, 415V, FP MCCB of 36kA.with adjustable O/L and S/C protection. Make: Legrand (DPX3)/ Schneider (Compact NSX) /Siemens (3VL)/L&T
4 nos. 63 A, 415V, FP MCCB of 25kA.with adjustable O/L and S/C protection. Make: Legrand (DPX3)/ Schneider (Compact NSX) /Siemens (3VL)/L&T
2 nos. 63A, 415V, FP MCB
6 nos. 40A, 415V, 4P MCB of 10kA..
1 No. APFC Relay suitable for controlling of 12 Nos relay output.
200KVAR Capacitor Bank in 12 steps having MCB/MCCB for protection, Contactors as per AC6 Duty for automatic switching, having auto manual switch and indication for each step.
There will be an automatic interlocking system between incoming breakers and bus coupler fulfilling the complete AMF function of both DG sets including automatic start and stop functions. This will be achieved through PLC logic controls.
Any item not specifically mentioned but required for completing the Interlocking scheme will be considered as part of scope of supply of vendor.
PANEL-2 (FLOOR PANELS)Supplying, fixing, testing & commissioning of 415V ,3Phase 50Hz, 4wire system,sheet steel clad,dust & vermin proof cubical & indoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2mm/1.6mm CRCA sheet steel complete with aluminium Bus Bars, Providing & Fixing of base plate /channel, P/F the following Switchgears,complete with earth Bus Bar throughout the length of the panel,terminal arrangement for incomings/outgoings cables and also outgoing terminations for various sizes of cables,the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement,adequate size bus duct/cable alley, Sign writing,Painting,Earthing,Numbering,Danger plate etc. Complete as requried,numbering, danger plate etc. complete as required as per specification and drawing. All MCCBs Shall be Ics=100%Icu. Make: Legrand(Adlec) or eqivalent as per approved make list and as direction by engneer in charge. PTTA Panel
INCOMER:
1 nos. 160A 415V, Ics=36KA, 4P MCCB with TM release having adjustable O/L, S/C protection.
1 nos. Digital type multi function meters (V+A+Hz) with cast resin CTs 630/5A.
1 Set of phase indicating lamp with MCB
1 No. 500A, 4pole onload changeover switch.
BUSBAR
500A TPN Bus bar of aluminimum alloy.
OUTGOING
6 nos. 63A, 415V, FP MCB
6 nos. 40A, 415V, 4P MCB of 10kA..
6 nos. 32A, 415 V, 4P MCB of 10kA
12 nos. 63A, 230V, 2P MCB of 10kA
Supply of following sizes of XLPE insulated Aluminum Armoured cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications.
2CX10 SQMM AL ARMOURD CABLE
4CX10 SQMM AL ARMOURD CABLE
3.5CX35 SQMM AL ARMOURD CABLE
3.5CX95 SQMM AL ARMOURD CABLE
3.5CX120 SQMM AL ARMOURD CABLE
3.5CX150 SQMM AL ARMOURD CABLE
SITC of 11 KV, 630 Amp Outdoor type HT RMU. The RMU Should consist on one no of Load break switch (LBS) as incomer and one VCB as outgoing. The RMU should be type tested according to IEC 62271-100, 200 & 102, IAC AFL, 21 kA for 1 sec, IP class 54, IP 67 for Tank. The rated voltage should be 12 kV, impulse withstand voltage of 75 kVp, Power frequency withstand voltage of 28 kV, rated short time current of 21 kA for 3 sec. The RMU should have SF6 gas insulation, robotic welding of gas tank. The RMU should be suitable for outdoor application. The manufacturer should have service centre in the state of uttarakhand.
Supply,Installation, testing & Commissioning of double pole structure suitable for 11 KV HT system as per CEA & UPCL norms & comprising of the following ,but not limited to it for completion of works . RSJ pole of 9 mtrs length of size 175 X 90 mm complete with suitable MS base plate welded at bottom base plate - 2 nos.MS channel of size 100 X 50 mm , length 4 mtrs (approx.)11 KV AB switch - 1 set , 11 KV Horn gap fuse unit - 1 set , 11 KV Lightning Arrestor , 11 KV Disc Insulator , 11 KV pin insulator 6 swg copper wire for jumpering Supply and erection of stay set complete with necessary foundation , excavation, and refilling of earth etc. as required. Concrete foundation for RJS poles burried upto a depth of 1830mm in ground in a pit of size 450 X 450 mm in CC 1:3:6 along with 200 mm copping above ground inclusive of earth work.Necessary Nut , Bolts, Clamps, operating handle for AB switch , clamping welding etc. complete as required. Painting the RSJ poles complete with two coat of red oxide and two coats of GI enamel paints complete as required.
Supply, installation, testing and commissioning of outdoor TYPE, OIL type transformer with copper winding having a continuous rating of 400 kVA, 11kV/415 +/- 1% V, 3 phase, 50 Hz, DY-11 vector group, The transformer shall have cable end box for indoor termination of HT cable on HT side and Cable Box for indoor termination on LT side, complete in all respects including standard accessories. It is To be installed on Top of two pole structure with proper iron angle channel support as required.Compliance to BEE Standards AND BIS Standards (IS 1180).
Supply of HT (UE) AL XLPE Cable of size 3 C X 120 sq mm
Fire Hydrant System
Supply,installation,testing and commissioning of MS C class Heavy duty pipe Inclueding forged fitting such as bends, tees, reducers,welding rods,two cote red oxide peimer and one cote post office red paint,angle,fastnor,two cote black japan etc. as follow
100 mm line (approx.) C Class
80mm line (approx.) C Class
25mm line (approx.) C Class
SITC of wrapping coating of pipe line in trenches
Supply,installation, testing and commissioning of single headed landing valve of 63mm dia. Made of SS hydrant valve complete with necessary fitting.
Supply,installation, testing and commissioning of RRL Hose pipe with 63mm dia. and 15mtr.length with SS male and female couplings.
Supply,installation, testing and commissioning of 63mm dia. SS short branch pipe nozzle suitable for instantaneous connection to hose coupling as required.
Supply,installation, testing and commissioning of MS hose box keeping two no.of RRL hose pipe and one no.of short branch pipe.
Supply,installation, testing and commissioning of two way fire brigade inlet connection suitable for local fire tender complete as required.
Supply,installation,testing and commissioning of swinging type first aid fire hose reel of 20mm internal dia and 30 mtr long with MS drum and 5mm shut of nozzle complete with fitting complete as required.
Supply,installation,testing and commissioning of gun matel body air release valve complete with all fitting as equired like ball vlave,holdtite,suta etc.
Supply,installation,testing and commissioning of Cast Iron body Butterfly Valve complte with all fitting as requied like MS flange, nut bolts,washers etc.
Supply,installation,testing and commissioning of Cast Iron body Non return valve complte with all fitting as requied like MS flange, nut bolts,washers etc.
Supply,installation,testing and commissioning of Pressure Gauge. (0-10kg).
Supply,laying,testing and commissioning of alluminium armoud cable complete with all fitting as required like lugs,glands etc.of following sizes:
16mm x 4core. From pump electric panel to fire pump .
35mm x 3.5 core
10mm x 4 core
Supply,installation,testing and commissioning of gun matel body Ball Valve.25mm dia.
Supply,installation,testing and commissioning of pressure switch (maximum pressure range 10kg/sq high)for hydrant stand by and jocky pumps, complete as required.
Supply,installation,testing and commissioning of air vashal tank complete with all fitting like air release valve,ball valve,MS Flanges,holdtite,suta etc.(200mm dia x 2000mm length).
Supply,installation,testing and commissioning of Terrace tank made of zinc aluminium sheet and plastic lining 10,000 Ltr
Connection of terrace tank with existing water supply line
Supplying,Installatoin,Testing,& Commissioning of Terrace pumps of 450 lpm @ 45 mtr head
Supply, installation, testing and commissioning of starter for terrace pumps
RCC Hole Cutting
Digging of underground line
Providing and fixing anti vivration mounting for pipe line - 100 mm dia
Supplying,Installatoin,Testing,& Commissioning of electric driven Hydrant Pump suitable for automatic operation consisting of the following complete in all respects as required.Horizontal type,multistage,centrifugal,split casing pump of cast iron body & bronze impeller with stainless steel shaft,mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm at highest and farthest oulet at specified flow of 1620 LPM at 50 M head conforming to IS:152 Suitable HP Squirrel cage induction motor,TEFC synchronous speed1 RPM,suitable for operation on 415 V3 phase 50 Hz,AC with IP 55 protection for enclosure,horizontal foot mounted type with class F insulation,conforming to IS:325.Pump set shall be assembled at works and tested to satisfy performance requirements.MS fabricated Common base plate,coupling,coupling guard,found bolts etc as require Suitable cement concrete pump foundation duly plastered with anti vibration pads.
Supplying,installation,testing,& commissioning of diesel engine driven Horizontal type,multi stage,centrifugal pump of cast iron body and bronze impeller with stainless steel shaft,mechanical seal to ensure a minimum pressure of 3.5 kg/sq. cm at highest and fartest outlet at specifiedflow of 1620 LPM at 50 M Head conforming to IS:1520 Suitable hp,2000 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standarde complete with auto starting mechanism,12 volts/24 volts electric starting equipment,Diesel Tank,exhaust pipe extended to1.0 Moutside pump house duly insulated with 50 mm thick glass wool with1.0 mm thick aluminium sheet cladding,residential silencer, instruments and protection as per satisfy performance requirements. MS fabricated specification,stop solenoid for auto stop in the event of fault with audio indications,apinted with post office red colour etc as required.Pump set shall be assembled at works and tested to Common base plate,coupling,coupling guard,foundation bolts etc as required.Suitable cement concrete pump foundation duly plas - tered with anti vibration pads.
Supplying,Installatoin,Testing,& Commissioning of electric driven Pressurisation Pump (Jockey pump) suitable for automatic operation consisting of the following complete in all respects as required.Horizontal type, multi stage,centrifugal,split casing pump of cast iron body & bronze impeller with stainless steel shaft,mechanical seal and flow of 180 LPM at 50 M head conforming to IS:1520.Suitable HP Squirrel cage induction motor,TEFC,synchronous speed 2900 RPM,suitable for operation on 415 V,3 phase 50 Hz,AC with IP 5 protection for enclosure,horizontal foot mounted type with class F insulation conforming to IS:325.MS fabricated Common base plate,coupling, coupling guard, foundation bolts etc as required Suitable cement concrete pump foundation duly plastered with anti vibration pads.
Fabrication and Supplying of Fire Fighting Panel of cubical construction, floor mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, having switchgears and accessories mounting and internal wiring, earth terminal, numbering etc.complete in all respects, suitable for operation on 415 V, 3 phase 50 Hz. AC supply with enclosure protection class IP 52 as required.
(INCOMER & METERING)
200A TP 36 KA MCCB with Inbuilt thermal magnetic release
Set of 3 Phase indicating lamp.
Set of Al. bus bar of 400A capacity.
(OUTGOING)
(a) MAIN FIRE PUMP- Nos
100A TP 36 KA MCCB with inbuilt thermal magentic release
withsuitable for 40HP fully automatic Star delta starter with Power
Contrator, over load protection, current sensing type single phase
preventor complete with all accessories and internal wiring required
/OFF operation.
(b) JOCKEY PUMP - Nos
63A TP 10 KA MCB with inbuilt thermal magnetic release with
suitable for 10 HP fully automatic Dol starter with Power Contractor,
over load protection, current sensing type single phase preventor
complete with all accessories and internal wiring required for
OFF operation.
(c) DIESEL ENGINE CONTROL - Nos.
Control for 24V Diesel Engine comprising-
and relays as required, push buttons, start/stop in manual mode.
Indication lamp for High/low lub. Oil pressure, High water Temp.
and Engine ON Indication.
Fire fighting panel as above
Supply and installation of ABC powder stored pressure type portable fire extinguisher ISI marked 15683- 2006 & ISO - 9001, complete as required capacity - 6 kg
Supply and installation of CO2 type fire extinguisher ISI marked steel body 15683- 2006 & ISO - 9001, complete as required capacity - 4.5 kg
Supply and installation of Mechanical Foam (AFFF) type fire extinguisher ISI marked steel body 15683- 2006 & ISO - 9001, complete as required capacity - 9 ltr
Supply,installation of fire Bucket as per IS spacification with stand (holding four bucket).
Supply, Installation, Testing and Commissioning of 5 HP Electric Driven Fire Pump suitable for auto/maual operation & consisting of following: complete in all respect like pump, motor, coupling etc.
Fabrication, Supplying, Installation, Testing & Commissioning of Starter for Pumps
SITC of Cable for pump 4cx6 mm Aluminium armoured
SITC of Foot Valve
Supply and fixing of GI line of 50 mmdia for pump room
Supply,installation,testing and commissioning of Cast Iron body Butterfly Valve complte with all fitting as requied like MS flange, nut bolts,washers etc.
FIRE ALARM SYSTEM
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply, installation testing and commissioning of the following Addressable Fire Detection and Alarm System items as per specification
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector, soft addressable Photothermal type with inbuilt fault isolator complete with base as required
Supply, Installation,Testing & Commisioning of Analogue Addressable Intelligent multisensor detector photothermal type(O2T WITH ALARM DEVICES) with inbuilt fault isolator,sounder,flasher and speech unit complete with base as requiredAddressable Intelligent Smoke detector photoelectric type with inbuilt fault isolator,sounder,flasher and speach unit complete with base as required.
Supply, Installation, Testing & Commissioning of Response Indicator as required. As approved
Supply, Installation,Testing & Commisioning of Microprocessor based 2 loop fire alarm control panel fully networkable with each loop capable of taking 127 devices, 8 line x 40 character alpha-numeric liquid crystal display.The panel shall be soft addressable type . The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, built in printer to log all fire or fault events complete in all respects, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. for each Tower
Supply, Installation,Testing & Commisioning of Repeater Panel with 8 line X 40 characters alpha numeric LCD display with all commands such as reset, mute, silence with suitable battery backup complete as required
Providing and fixing of Exit Sign Boards with compact flurecent light complete in all respects
Supply and fixing of High intensity Sounder with mounting base.
Providing , installation , testing & commissioning of Glass Break Type Manual Call Point
VRF SYSTEM
Variable Refrigerant Volume / Flow system
Supply, Instalaltion, testing & commissioning of Variable Refrigerant Flow modular type airconditioning system with stepless modulation complete with indoor and outdoor units, individual remote controller & centralized controller, interconnected refrigerant piping , full charge of refrigerantgas & oil, control cabling etc. as per detail given in specifications & having following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.
SITC of Outdoor Unit
Supply Instalaltion, testing & commissioning of Modular type outdoor units equipped with highly efficient scroll compressors with one inverter & other constant speed type compressor (s) , special heat exchanger, low noise condenser fan , auto check function for connection error, auto address setting and capacity as mentioned below.
36 HP Heat Pump Type (Cooling & Heating )
Supply Instalaltion, testing & commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, coil section with DX coil, outer cabinet, drain pan, drain water lift-up mechanism insulation, pipe connections, fresh air intake etc. of various capacities as per specifications and drawings
Ceiling Mounted Cassette Type : 1.0 TR
Ceiling Mounted Cassette Type : 1.33 TR
Ceiling Mounted Cassette Type : 1.6 TR
Ceiling Mounted Cassette Type : 2.0 TR
Ductable Type : 6.6 TR
Supply Instalaltion, testing & commissioning of TFA Unit
5.0 HP TFA UNIT
Supply Instalaltion, testing & commissioning of Y-joints.
Supply Instalaltion, testing & commissioning of self diagnostic type remote controllers .
Corded Type
Supply& Fixing of Interconnecting copper refrigerant pipe work 25 mm / 19 mm thick duly insulated with XLPE Foam closed cell cross linked polythene insulation between indoor and outdoor units as per specifications. All piping inside the rooms shall be properly supported on MS Slotted trays and all external piping shall run in covered slotted tray.
41.3 mm O.D. (insulation – 19 mm thick)
38.1 mm O.D. (insulation – 19 mm thick)
34.9 mm O.D. (insulation – 19 mm thick)
31.7 mm O.D. (insulation – 19 mm thick)
28.6 mm O.D. (insulation – 19 mm thick)
25.4 mm O.D. (insulation – 19 mm thick)
22.2 mm O.D. (insulation – 13 mm thick)
19.1 mm O.D. (insulation – 13 mm thick)
15.9 mm O.D. (insulation – 13 mm thick)
12.7 mm O.D. (insulation – 13 mm thick)
9.5 mm O.D. (insulation – 13 mm thick)
6.4 mm O.D. (insulation – 19 mm thick)
Supply and fixing of PVC drain water piping complete with fittings, support as per specification and insulated with 6 mm thick insulated with XLPE Foam closed cell cross linked polythene insulation.
25 mm dia
32 mm dia
Supply , fabrication & installation of Sheet Metal ducting complete with supports dampers etc. as per ISI specification and drawings.
0.63 mm ( 24 Gauge)
0.80 mm ( 22 Gauge)
Providing and fixing of aluminium supply air and return air grilles and diffusers fabricated from extruded aluminium sections duly powder coated.
Supply air grill with damper
Return air grill without damper
Duct Damper - VCD
Supplying & fixing of Fresh air intake louvers with bird screen dampers (Aluminium extruded only).
Supplying and fixing of acoustic lining of duct with Open Cell Nitrile Rubber density 140-180 Kg/m³. Applied by Adhesive, conforming to standard specification.
10 mm thick open cell nitrile rubber.
Supplying and fixing of external thermal insulation on ducts with Closed Cell Cross Linked Polythylene (XLPE) Foam of density 33 Kg/m³ with 13 mm & 09 mm thick & thermal Conductivy not exceding 0.035 W/mK at an average Temperature of 40°C. The Material Shall be rated as Class 1, As per BS476 Part 7 , The Smoke Density as per AS - 1530.3 Shall not exceed 1. The Material shall have Fire Approval from CBRI - Roorkie & no toxicity under flaming and non- flaming condition as per AITM 3.000 (1993) . Adhesive used for setting the insulation shall be non - flammable, Vapour Proof. All Joints should be sealed with 3 mm thick 50 mm wide PE tape and Flange to be overlapped by 6" width of the same material thickness. Finally Duct insulated should be strapped by 12 mm Plastic Packing strip at every random meter and conforming to standard Specification
13 mm thick Closed Cell Cross Linked Polythylene( XLPE) Foam with Factory Laminated Al PE Foil for Supply Air Duct
Providing and Fixing Canvas Connection of Fire Retardant and non porous double layer material between each indoor units and ducts
M/s Mahalaxmi Construction
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
SBD.pdf
Tender Documents • 7.28 MB
BOQ_44055.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .