| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 1ST FLOOR B 3 111 9 YASHIKA APARTMENT KISHAN GARH VASANT KUNJ NEW DELHI 110070 | NEW DELHI | DELHI | 110070 | Accepted-Technical Accepted |
| 2 | Not Admitted-Fee/PreQual/Technical 121 RANI DURGAWATI WARD NO 34 H S S SCHOOL SHOBHAPUR BETUL MADHYA PRADESH 460449 | BETUL | MADHYA PRADESH | 460449 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹7.0 L
EMD Value
₹13,922
Closing Date
15 Jun 2026, 3:00 pmClosed
Executive Engineer (E)
O/o The Executive Engineer (E) South Elect. Div., PWD, Sukhdev Vihar, Mathura Road, Near Okhla Flyover, New Delhi
Replacement of Electrical bus bar trunking system at B Block, D-II, Vasant Kunj, New Delhi
2026_PWD_293002_1
27/EE(E)/EMD South Elect. Divn./PWD/2026-27
Open Tender
Electrical Works
Works
30 days
New Delhi
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹13,922
Yes
24 Jun 2026
8 Jun 2026
15 Jun 2026
8 Jun 2026
15 Jun 2026
8 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying Installation, Testing and Commissioning of on wall, testing and commissioning of following capacity rising mains made of 1.6mm thick IP 42 sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium bus bars having current density of 130 A/sq.cm at nominal current rating in convenient sections and suitable for 415 V, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439). | |||||
| 1.01 | 800 A (S.C. rating for 1 sec - 50 kA) | 28 | Mtr | 13,241 | ₹3,70,748 |
| 2Supplying Installation, Testing and Commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. | |||||
| 2.01 | 63 A TPN | 18 | Each | 12,116 | ₹2,18,088 |
| 3Supplying Installation, Testing and Commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. | |||||
| 3.01 | 800 A TPN | 1 | Each | 38,140 | ₹38,140 |
| 4Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning with steel enclosure etc. as required. | |||||
| 4.01 | 63 A | 18 | Each | 3,597 | ₹64,746 |
| 5 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. | 2 | Sets | 8,351 | ₹16,702 |
| 6 | Core cutting of following sizes on the existing wall/cc foundation with help of heavy duty hammer machine & other special T & P items and after busbar work filling the gap with the help of mixture of cement, sand (mortar work) i/c finishing the surface etc. complete as required.
a) 40cm x 50cm– 9 Nos. | 1 | Job | 8,652 | ₹8,652 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.14 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.54 MB
BOQ_389248.xls
BOQ • 0.31 MB
NIT.pdf
Tender Documents • 2.53 MB
Corrigendum27.pdf
PDF • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .