Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹10.8 L+₹79,740.50 (7.99%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹10.8 L+₹87,152.50 (8.74%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹11.0 L+₹98,765.50 (9.90%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹11.7 L+₹1.8 L (17.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
10 Jan 2022, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
REPAIR AND MAINTENANCE OF SECURITY/ STREET/ HIGH MAST/ SOLAR LIGHT SYSTEM, CERTAIN SUB STATION, LT DISTRIBUTION SYSTEM CAPACITOR BANKS AND OTHER ALLIED WORKS AT INS KARNA AND NAD (BHEEMUNIPATNAM) UNDER GE(P) NAVY KALINGA
2021_MES_494536_1
GE (P)/N/K/8849 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class E, Category b(i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹32,000
Yes
24 Mar 2022
14 Dec 2021
12 Jan 2022
14 Dec 2021
10 Jan 2022
28 Dec 2021
Amount
M&L for taking down high pressure SV/MV/MH/FTL/LED street light fittings and flood Light fittings of any wattage/ any height of pole/walls/ any location for repairs or replacement of burnt out the accessories and rectifying the fault etc. complete all as specified and as directed by the Engineer-in-Charge. Note: LED drivers, surge protection and cable etc. shall be measured separately under relevant items of this schedule.
S&F in repair LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 40 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LSTS-40-CDL-M or equivalent as approved by GE
S&F in repairs, LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 60 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No.LSTP-60-CDL-M or equivalent as approved by GE
S&F in repair LED Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 120 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LFLN-120-CDL/60-M or equivalent as approved by GE
S&F in repair LED Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 200 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LFLN-200-CDL/60-M or equivalent as approved by GE
S&F LED flood light 250 W, 230 Volts luminaire with pressure die-cast aluminium housing IP 65 protection, any height and any location including internal prewired with all materials complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LFLPI-250-CDL/60-M or equivalent as approved by GE
Supply only drivers for LED street lights 25W/35W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply only drivers for LED street lights 45W/60W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply only drivers for LED flood lights 100W/120W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply only drivers for LED flood lights150W/200W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply, laying and testing 3 core round flexible cable 1.5 Sq.mm. PVC insulated, 1100 Volts grade, PVC sheathed with two runs of single core multistranded FLRS copper conductor along with one run of necessary earth continuity conductor of 1.5 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge.
S&F digital time switches with battery back up 1100 hours with current capacity 16 A programmable every 1min with 1 changeover and total 28 programs complete all as specified and as directed by the Engineer-in-Charge. Make: Indoasian Cat. Part No. TDA43110 or equivalent as approved by GE
S&F in repairs contactor ML-2 of capacity of 32 Amps AC 3 phase heavy duty including taking down old unserviceable contactor complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs contactor ML-3 of capacity of 40 Amps AC 3 phase heavy duty including taking down old unserviceable contactor complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair timelite distribution board 32 Amps, 3 pole, 230 volts digital time switch complete all as specified and directed by Engineer-in-Charge. Make: Indoasian cat No. TL032DB0 or equivalent as approved by GE
M&L for cleaning the swaged steel tubular street light poles of 9/11 meters height including GI pipe of street light fitting and preparation of surfaces by cleaning including scrapping up old corroded paint/dirt/dust/rust carefully and applying two coats of aluminium paint over one coat of metal primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including writing of pole numbers and two coats of colour washing on PCC coping surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L for cleaning the pre-stressed cement concrete street light poles of 9/11 meters height, preparing old plastered or unplastered surfaces and applying two coats of cement based paint over one coat of primer including writing of pole numbers and two coats of colour washing on PCC coping surfaces complete all as specified and as directed by the Engineer-in-Charge.
S&F GI bracket suitable for street light fitting made out of 40mm dia. GI tubing of light grade bent to shape of 1.5m length complete including taking out old one complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying LT underground cable XLPE insulated and sheathed armoured cable 1100 Volts grade of size 4 core 16 Sq.mm. aluminium conductor in trenches/poles and connecting with all accessories including taking out the old unserviceable cable complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m depth and getting out soft/loose soil for laying of under ground cable complete all as specified and as directed by the Engineer-in-Charge.
Returning/filling including spreading, levelling and well ramming in layers n. exc. 25cm in thick complete all as specified and as directed by the Engineer-in-Charge.
Removal of surplus soil to a distance n. exc. 50m away and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and as directed by the Engineer-in-Charge. Note: Only punned thickness of 18cm will be measured for the purpose of payment.
Supply and lay unreinforced precast concrete cable cover class LV, type 1, flat, size 250mmX150mmX40mm for protection of cable, laying in trenches complete all as specified and directed by the Engr-in-Charge
Supply and lay GI pipe 25mm dia. light grade for cable protection as per site requirement and sealing the pipe both ends with sealing compound complete including taking down old one complete all as specified and as directed by the Engineer-in-Charge.
S&F HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP-65 protection of size 250x250x150mm with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and as directed by the Engineer-in-Charge. Make: Hansel/Sintex
S&F in repairs, MS clamps suitable for 40mm GI pipe made out of 25x4mm flat iron complete with necessary nuts and bolts complete all as specified and as directed by the Engineer-in-Charge.
S&F rigid non metallic PVC conduit 20mm dia. including all the fittings like Tees, bends, elbows, reducers etc. and fixtures such as couplers, lock nuts, saddles, pipe hooks etc. complete including taking down old one complete all as specified and as directed by the Engineer-in-Charge.
M&L for repairs and maintenance of LED solar lights with charging and topping up distilled water in solar light batteries to maintain necessary specific gravity with replacement of damaged battery lead clamps and worn out leads including taking down and fixing of batteries to its position complete all as specified and as directed by the Engineer-in-Charge.
Taking down high mast light of size 12/15/16 mtr from its base with help of crane, cleaning, greasing, and overhauling of all moveable parts like pullies,steel wire,chain,winches etc,replace unserviceable light if required and refix the mast on its original position complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs of Aviation light comprising aluminium housing and polycarbonated enclosure at any height and location complete all as specified and as directed by the Engineer-in-Charge. Make:-Bajaj/Havells/Crompton/C&S
S&F in repairs 12 Volt, DC, 75Ah/100Ah, maintenance free valve regulated Lead acid(VRLA) solar GEL Battery complete all as specified and as directed by the Engineer-in-Charge.
Labour charges for re-laying of serviceable bricks of any size and type recovered during taking out of old cable , over newly laid or re-laid cables all complete as specified and as directed.
M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type C-1 using 20mm graded aggregates complete all as specified
M&L for 50mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified.
M&L for 80mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified.
Taking down or out existing cable of sizes 2/3.5/4 core 10 sqmm to 70 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge (Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid separately under respective item of this schedule)
All as per Item No 37 here-in-before but for cable of size 3.5 core 95 sqmm to 300 sqmm
Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 2/3.5/4 core 10 to 70 sqmm in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as specified and as directed (Note :- Lugs and Glands will be measured and paid separately)
All as per Item Sl Item No 39 here-in-before but for cable of size 3.5 core 95 to 240sqmm
S&F XLPE insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc including taking out old unserviceable cable complete all as directed and specified.
All as per Item Sl Item No 41 here-in-before but for cable of size 10 sqmm 4 core
All as per Item Sl Item No 41 here-in-before but for cable of size 25 sqmm 4 core
All as per Item Sl Item No 41 here-in-before but for cable of size 35 sqmm 3.5 core
All as per Item Sl Item No 41 here-in-before but for cable of size 50 sqmm 3.5 core
All as per Item Sl Item No 41 here-in-before but for cable of size 70 sqmm 3.5 core
All as per Item Sl Item No 41 here-in-before but for cable of size 95 sqmm 3.5 core
All as per Item Sl Item No 41 here-in-before but for cable of size 120 sqmm 3.5 core
M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10/16 sqmm x 2/4 core cables including testing and commissioning complete all as specified and as directed.
All as per Item Sl Item No 49 here-in-before but for cable of size 25 to 50 sqmm x 3.5 /4 core
All as per Item Sl Item No 49 here-in-before but for cable of size 70 to 120 sqmm 3.5 /4 core
All as per Item Sl Item No 49 here-in-before but for cable of size 150 to 185 sqmm 3.5 /4 core
All as per Item Sl Item No 49 here-in-before but for cable of size 240 to 300 sqmm 3.5 /4 core
S&F in repair 400 Amp, 36 KA, 4 Pole MCCB, 50 KA, 415V, 50 Hz, AC supply, Ics=100% Icu, adjustable Overload 80-100%, thermal magnetic release mechanism including necessary cable lugs & wire etc complete all as specified and directed.
All as per Item Sl Item No 54 here-in-before but of capacity 250 Amp, 4 pole MCCB, Icu =35/36 KA
All as per Item Sl Item No 54 here-in-before but of capacity 200 Amp, 4 pole MCCB, Icu =25/26 KA
All as per Item Sl Item No 54 here-in-before but of capacity 125 Amp 4 pole MCCB, Icu =18 KA
All as per Item Sl Item No 54 here-in-before but of capacity 63 Amp 4 pole MCCB, Icu =18 KA
S&F in repair aluminium lugs suitable for 240 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed.
All as per Item Sl Item No 61 here-in-before but for 185 Sqmm.
All as per Item Sl Item No 61 here-in-before but for 120 Sqmm.
All as per Item Sl Item No 61 here-in-before but for 95 Sqmm.
All as per Item Sl Item No 61 here-in-before but for 70 Sqmm.
All as per Item Sl Item No 61 here-in-before but for 50 Sqmm.
All as per Item Sl Item No 61 here-in-before but for 25 Sqmm.
All as per Item Sl Item No 61 here-in-before but for 16 Sqmm.
All as per Item Sl Item No 61 here-in-before but for 400 Sqmm.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel, complete all as specified and testing on completion.
S&F in repair 250 Amp, 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site requirement, adjustable type of thermal and magnetic setting, handle, including necessary cable lugs & wire etc complete all as specified and directed.
S&F in repair 160 Amp, 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site requirement, adjustable type of thermal and magnetic setting, handle, including necessary cable lugs & wire etc complete all as specified and directed.
M&L for disconnecting, remove the electric supply of existing APFC panel, complete repairs and servicing the panel including remove and replacement of power factor contactors, relays, CT, indication lamps, capacitor banks, any make/ any capacity and calibration of APFC relay changing of copper wire for control wiring, for indication lamps, lugs, bolts and nuts and decarbonising, blowing with blower the panel board complete all specified and directed of capacity up to 250 KVR capacitor bank, complete testing and commissioning the panel all as directed and specified by Engineer in charge. (Note: - Capacitor, contactor, indication lamps, CT and APFC relay, shall be measured and paid separately.)
SRIVALLI ENGINEERS
SWATHI CONSTRUCTIONS
S V ENGINEERING WORKS
VASANTHA NAIDU ASSOCIATES
R AND A ASSOCIATES ENGINEERS CONTRACTORS
suresh electricals
S V S ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .