Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.4 LAccepted-AOC 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹19.4 L+₹1.9 L (11.1%)Rejected-Finance | L-2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L-3₹19.9 L+₹2.5 L (14.2%)Rejected-Finance 37 B MODEL TOWN NEAR HARI MANDIR BAREILLY UP 243001 | BAREILLY | UTTAR PRADESH | 243001 | L-3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L-4₹21.1 L+₹3.7 L (21.2%)Rejected-Finance H NO 786 ANAND VIHAR COLONY PILIBHIT BYPASS BAREILLY UP PIN 243005 | BAREILLY | UTTAR PRADESH | 243005 | L-4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L-5₹21.3 L+₹3.8 L (22.0%)Rejected-Finance 121 BEHARIPUR MEMARAN BAREILLY UP PIN 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L-5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹25.9 L
EMD Value
₹51,800
Closing Date
9 Jun 2020, 6:00 pmClosed
Garrison Engineer, Air Force, Izatnagar, Bareilly
Garrison Engineer, Air Force, Izatnagar, Bareilly, 243002
UPGRADATION / IMPROVEMENT OF DINNING HALL NO. 3 OF AIRMEN MESS, PROVISION OF INTERLOCKING ALONG ROADS AT CERTAIN PLACES AND PROVISION OF SHED OVER CERTAIN RMUs AT AF STATION IZATNAGAR, BAREILLY.
2020_MES_337002_1
8518 / E8
Open Tender
Civil Works
Item Rate
180 days
Izatnagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹51,800
Yes
4 Aug 2020
31 Mar 2020
11 Jun 2020
31 Mar 2020
9 Jun 2020
15 Apr 2020
31 Mar 2020 - 15 Apr 2020
Amount
Disconnecting existing tank exc. 500 Litre but not exc. 1000 Litres capacity, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
Dismantling of water tank exc. 250 Litre but not exc. 500 Litre capacity complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connection complete all as specified and directed.
Taking down PVC rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks etc. complete all as specified and directed.
S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position complete all as specified and directed.
S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
Re-fixing of 20 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repairs 75 mm dia cast iron floor trap long neck without grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed.
S & F in repairs 75 mm bore cast iron soil, waste and vent pipe, sand cast, in any length, with or without ears, with cement joints in cement sand mortar 1:1 with spun yarn laid in trenches or under floors complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels not exc. 3.00 Sqm each panel, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified.
M & L for rendering 10 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat etc. for fixing complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing 0.55 Kg per running metre including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door, hinges, anodised aluminum snap beading, screws etc. complete all as specified and directed.
Supply only 5.50 mm thick tinted or reflective type sheet glass in square any size as required at site complete all as specified and directed. NOTE- FIXING CHARGES OF THIS ITEM SHALL DEEMED INCLUDED IN THE UNIT RATE OF ITEM NO. 27.00 OF THIS SCHEDULE.
M & L for 12 mm thick block board grade 1 quality, exterior grade, decorative type with both faces decorative veneers and fixed with screws to timber framework complete all as specified and directed.
S & F of aluminium extruded sections body door closer hydraulically regulated designation No. 3, universal type suitable for door shutter 851 to 1000 mm in width and 61 to 80 Kg in weight complete all as specified and directed.
S & F of 65 mm size two levers, brass mortice lock, vertical type complete all as specified and directed.
S & F of 140 mm size (Overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
S & F of 150 mm long (Length of bolt) mild steel barrel tower bolt stove enamelled black with bright bolt complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for 25 mm thick (Average Thickness) cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in levelling course / sub floor of floor finishes, finished even and rough complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for vitrified ceramic, double charged, light coloured tiles 10 mm thick (Square or Rectangular) polished, area of each tile not exc. 0.36 Sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
M & L for glazed ceramic digital coloured or printed tiles 450 mm X 300 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
S & F in repairs 15 mm bore fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F of 100 mm dia grating doom of PTMT (minimum weight 25 gram) complete all as specified and directed.
S & F of 20 mm thick black granite (of any type) work (table rubbed and polished) in shelves, pillars, cooking platforms and the like, set in over and including 20 mm thick cement screed in cement mortar 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S & F in repairs 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F of 5 mm thick and 35 mm wide PVC sheet fillet for fixing of wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of solid PVC Wall Lining consisting of 5 mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of 5 mm thick dark coloured printed PVC sheet in strips and channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent cement as per specifications and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of Armstrong Mineral Fibre Accoustic Suspended Ceiling System with ANF Angled Tegular edge tiles with Armstrong Prelude 24 mm exposed grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS-476, Part-6 & 7) in module size of 600 X 600 X 15 mm, suitable for Green Building application, with Recycled content of 30%. The tile shall be laid on Armstrong Prelude 32 with 24 mm wide T-section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 8.5 Kgs per Sqm (as per standard installation layout mentioned below) & pull out strength of minimum 100 Kg. The T-Sections have a Galvanizing of 90 grams per Sqm and need to be installed with Suspension system of Armstrong make. INSTALLATION- To comprise main runner spaced at 1200 mm securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200 mm maximum. The First / Last Armstrong suspension system at the end of each main runner should not be greater than 450 mm from the adjacent wall. Contd......
Flush fitting 1200 mm long cross tees to be interlocked between main runners at 600 mm to form 1200 mm X 600 mm module. Cut cross tees longer than 600 mm require independent support. 600 X 600 mm module to be formed by fitting 600 mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000 X 19 X 19 mm, secured to walls at 450 mm maximum. Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure. ARMSTRONG SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M-6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia 2.50 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum pull strength of 110 kgs. (Adjustable hook clips of 0.7 mm thick, galvanized spring steel can also be used for installation purpose as an additional accessory. The adjustable clip also consists of a 4 mm aquiline wire to be used with the main runner).
Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges in rough finished surface of concrete complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1½:3 (Nominal Mix) type A-1, using 20 mm graded stone aggregate, as in chajjas and the like complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
M & L for providing precast cement concrete block in any shape as approved by GE made of PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in kerb stone 10 cm thick with and including necessary excavation, earth work and setting in cement mortar 1:4 complete all as specified and directed.
M & L for providing plain cement concrete, type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance exc. 1.50 Kilometres but not exc. 5.00 Kilometres and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for 60 mm thick, M-35 grade machine pressed pre-cast concrete interlocking paver block confirming to IS-15658 (2006) with grey cement and pigment in any shape and size as directed complete all as specified and directed.
M & L for 25 mm thick sand filling under floor finishes and the like including necessary watering and consolidation complete all as specified and directed.
M & L for preparation of new plastered or cement concrete surface of kerb stones and the like over 10 cm width or girth and applying two coats of synthetic enamel paint (In 02 different tints as directed at site) over one coat of primer complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out in soft / loose soil and removing surplus soil to a distance not exc. 50 m and making good disturbed surface complete all as specified and directed.
M & L for providing plain cement concrete, type B-2, 1:2:4 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS-1161(1979) grade St-240 complete all as specified and directed.
S & F of rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W (Grade E-250) quality-A complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S & F of mild steel bolts, purpose made, with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut, total length of bolt exc. 5 cm but not exc. 10 cm and dia of neck exc. 12 mm but not exc. 20 mm complete all as specified and directed.
Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, light fittings, shade conical etc. and making good disturbed surfaces of walls, floors ceiling as per existing specifications complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring of any description including batten or conduit complete all as specified and directed.
Taking down carefully old unserviceable main switch and distribution board any type and description with and including existing isolator, MCB and the like complete all as specified and directed.
M & L for point wiring in colour coding Red, Black and Green (RBG) for one light point / fan point (Independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including non-metallic PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 71.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 71.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 5 Ampere complete all as specified and directed.
S & F of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
S & F of ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate insulated body complete all as specified and directed.
S & F of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed.
S & F of wall / surface mounted type LED light fitting 1 X 20 watt (4 feet long), extruded aluminium batten with multiple lumen packages complete with all accessories internally pre-wired and including making electric connection with flexible twin core 1.00 sqmm size stranded copper conductor cable from light fitting to ceiling rose including dismantling of old unserviceable one complete all as specified and directed. Make- Philips Cat. Part No. BN021C LED20S PSU CW GR S2 (SmartBright) of Philips or ENDURALINEARNEOBS20WLED865SPCWH (ENDURA LINEAR NEO) of Havells.
S & F as in replacement ceiling or surface mounting suitable for 2'x2' ceiling grid as per Cat. Part No. RC380B LED36S 6500 G4 L60 W60 PSD OD WH OC (FullGlow Office Compliant) of Philips or VENUSNEOHE2X2R42WLED857SMARTPLUS (VENUS NEO HE 42W SMART PLUS) of Havells, duly pre-fitted with all accessories complete all as specified and directed.
Supply and fixing of 1200 mm sweep 240 volts, AC having BEE 5 star rating ISI marked, off white coloured ceiling fan complete with fan blade, capacitor, canopy, down rod etc. with and including making electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of ceiling fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high complete all as specified and directed.
S & F of electronic type fan regulator 230 volts, step type having five steps, switch type, hum free complete all as specified and directed.
S & F of 1100 volts grade heavy duty two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of multi-stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed for the following: -
(a) 2 X 4.00 sqmm as main wires + 1 X 2.50 sqmm as earth wire.
(b) 2 X 6.00 sqmm as main wires + 1 X 4.00 sqmm as earth wire.
S & F of flush mounting factory made Ekinoxe SPN DB's Double door, 8 way (Cat. Part No. 607711 of Legrand or Cat. Part No. A9HSND08 of SCHNEIDER or Cat. Part No. CSDBSPNDD08 of C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed.
S & F of MCB single pole and neutral, 240 volts, 32 to 40 Ampere breaking capacity 10 KA, ‘C’ Series complete all as specified and directed.
S & F of MCB single pole 240 volts, 6 to 32 Ampere 50 Hz, 10 KA, ‘C’ series complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
M/S Quality Constructions
MOHINDER SINGH AND SONS
Zaigham Enterprises
M/s M Aali construction co
VINOD TRADING CORPORATION
M/s KUMAR CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .