Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAdmitted-Fee/PreQual/Technical/Finance | ₹33.8 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹33.9 L+₹7,856.88 (0.23%)Admitted-Fee/PreQual/Technical/Finance | ₹33.9 L+₹7,856.88 (0.23%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | INTIMATE REFRIGERATION AND AIR CONDITIONS L2 | PIONEER COOLTECH L1 |
|---|---|---|---|---|---|
| 1.00Air Conditioning | |||||
| 1.00 | OD81520/2025-2026:Supply, installation, testing & commissioning of cassette type VRF indoor unit. All indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. Unit shall be provided wireless remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting. 4 Way Cassette 1.5 TR. | 10 | each | 55,890 ₹5,58,900 Lowest | 57,200 ₹5,72,000 |
| 1.00 | OD81524/2025-2026:Supply, installation, testing & commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSM. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit 6 TR. | 1 | each | 1,38,460 ₹1,38,460 Lowest | 1,41,500 ₹1,41,500 |
| 1.00 | OD81523/2025-2026:Supply, installation, testing & commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSM. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit 8 TR. | 1 | each | 1,44,072 ₹1,44,072 Lowest | 1,45,580 ₹1,45,580 |
| 1.00 | OD81521/2025-2026:Supply, Installation, Testing and Commissioning of modular type VRF odu. the outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF /VRV system shall be compact air-cooled type. all the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. Oem should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than ? 3.4 at Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket. 14 HP. | 1 | each | 3,96,760 ₹3,96,760 Lowest | 4,11,842.8 ₹4,11,842.8 |
| 1.00 | OD81525/2025-2026:Supply, installation, testing & commissioning of modular type VRF ODU. The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF/VRV system shall be compact air-cooled type. All the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. OEM should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than ? 3.4 at Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket. 22 HP . | 1 | each | 5,54,116 ₹5,54,116 Lowest | 5,75,205.1 ₹5,75,205.1 |
| 1.01 | OD81519/2025-2026:Supply, installation, testing and commissioning of Y joints indoor side, JRBLN03321, JRBLN07121 JRBLN014521. | 11 | each | 8,300 ₹91,300 | 7,925.54 ₹87,180.94 Lowest |
| 1.01 | OD81518/2025-2026:Supply, installation, testing and commissioning of Y joints outdoor side, ARCNN21. | 1 | each | 12,000 ₹12,000 Lowest | 12,032.05 ₹12,032.05 |
| 1.01 | OD81522/2025-2026:Supply and Fixing Wireless Remote for Ductable Air conditioning unit. | 10 | each | 2,000 ₹20,000 Lowest | 2,004.54 ₹20,045.4 |
| 1.01 | OD81530/2025-2026:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports.Ø6.35 | 45 | metre | 850 ₹38,250 Lowest | 858.54 ₹38,634.3 |
Tender Value
₹36.0 L
EMD Value
₹50,000
Closing Date
18 Sept 2026, 6:00 pmClosed
Executive Engineer
Office of Executive Engineer, PWD Electrical Division, Thiruvananthapuram 695033
DEPOSIT Govt Medical College Hospital Thiruvananthapuram Master Plan KIIFB Fund Upgradation of the Nuclear Medicine Department with High Dose Therapy Facility Air conditioning Electrical AC Work
2026_PWD_869281_1
PWD/BLDG/EST/12600/2025/AC
Open Tender
Electrical Works
Item Rate
180 days
Thiruvananthapuram
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,760
Yes
₹50,000
Yes
22 Sept 2026
11 Sept 2026
22 Sept 2026
11 Sept 2026
18 Sept 2026
11 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Air Conditioning | |||||
| 1.001 | OD81520/2025-2026:Supply, installation, testing & commissioning of cassette type VRF indoor unit. All indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. Unit shall be provided wireless remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting. 4 Way Cassette 1.5 TR. | 10 | each | - | - |
| 1.002 | OD81524/2025-2026:Supply, installation, testing & commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSM. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit 6 TR. | 1 | each | - | - |
| 1.003 | OD81523/2025-2026:Supply, installation, testing & commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSM. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit 8 TR. | 1 | each | - | - |
| 1.004 | OD81521/2025-2026:Supply, Installation, Testing and Commissioning of modular type VRF odu. the outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF /VRV system shall be compact air-cooled type. all the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. Oem should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than ? 3.4 at Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket. 14 HP. | 1 | each | - | - |
| 1.005 | OD81525/2025-2026:Supply, installation, testing & commissioning of modular type VRF ODU. The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF/VRV system shall be compact air-cooled type. All the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. OEM should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than ? 3.4 at Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket. 22 HP . | 1 | each | - | - |
| 1.006 | OD81519/2025-2026:Supply, installation, testing and commissioning of Y joints indoor side, JRBLN03321, JRBLN07121 JRBLN014521. | 11 | each | - | - |
| 1.007 | OD81518/2025-2026:Supply, installation, testing and commissioning of Y joints outdoor side, ARCNN21. | 1 | each | - | - |
| 1.008 | OD81522/2025-2026:Supply and Fixing Wireless Remote for Ductable Air conditioning unit. | 10 | each | - | - |
| 1.009 | OD81530/2025-2026:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports.Ø6.35 | 45 | metre | - | - |
stage.html
html • 0.02 MB
finance_1472607.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
MOM.pdf
Other Document • 0.08 MB
BOQ_1472607.xls
BOQ • 0.33 MB
viewsbd.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .