Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.4 LAccepted-AOC GARRISON ENGINEER GE NORTH BINNAGURI | JALPAIGURI | WEST BENGAL | 735232 | L-1 | Accepted-AOC Being L1 bidder | |
| 2 | L-2₹27.8 L+₹64,884 (2.39%)Rejected-Finance | L-2 | Rejected-Finance Being L 2 | |
| 3 | L-3₹29.4 L+₹2.2 L (8.25%)Rejected-Finance POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L-3 | Rejected-Finance Being L 3 |
Tender Value
₹32.6 L
EMD Value
₹62,500
Closing Date
29 Dec 2020, 6:00 pmClosed
GE North Binnaguri
Post Binnaguri Dist Jalpaiguri West Bengal
REPAIR AND MAINTENANCE TO STREET LIGHTS HIGH MAST LIGHTS FITTING AND EARTHING LT FEEDEER PILLAR BOX AND ALLIED WORK IN NORTH ZONE UNDER GE NORTH BINNAGURI
2020_MES_401387_1
NIT No. 8701/41/ 03 /E8 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BINNAGURI
Class D Category ai or bi
8 documents required · 8 mandatory
₹500
Yes
GE North Binnaguri
₹62,500
Yes
22 Jan 2021
7 Dec 2020
31 Dec 2020
7 Dec 2020
29 Dec 2020
17 Dec 2020
Amount
Taking down carefully old existing street light fitting (conventional) from pole without damaging the fittings and depossited to MES Store yard to kept in safe custody complete all as specified.
Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material and keep serviceable material for reuse in safe custody for any size complete as directed (Excavation/earth work shall be measured & paid separately under relevant item of this schedule)
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
Material and labour laying well burnt old size bricks, fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Labour only for laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Boring/Drilling ( horizontally) manually under existing road suitable for passing GI tubing of 40 to 80 mm bore complete all as specified.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 80 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 10 sqmm 2 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 16 sqmm 4 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 25 sqmm 4 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 25 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 35 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 50 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 95 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 185 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated,galvanised steel strip or wire armoured / PVC insulated armoured cable, aluuminium conductor stranded , 1100 volts grade 240 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Material and labour for Digging out incoming and outgoing cables of any sizes from loop near junction box/ feeder pillar box in tranches, cutting burntout uninsulated portion of cable abd rectify the defect and relaying the XLPE cable under ground aluminium conductor in trenches and returning and filling the excavated soil and connecting the cables with bus bars including provision of lugs as applicable and testing complete all as specified.
Supply and fixing in repairs street light bracket made out of GI pipe light grade 40 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.2 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 40 x 6 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixed LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen eual to/greater than 3300 lumen, system wattage 30 Watt, Ingress protection IP-66 with all acessories complete all as specified and directed.
Supply and fixed LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen eual to/greater than 4600 lumen, system wattage 45 Watt, Ingress protection IP-66 with all acessories complete all as specified and directed.
Supply and fixed LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen eual to/greater than 6000 lumen, system wattage 60 Watt, Ingress protection IP-66 with all acessories complete all as specified and directed.
Labour only for repairing of the street light fittings on pole or building / High mast light fittings (any height ) / garden lights / gate lights/ water proof flood light fittings etc by replacing the spares and refixing back its original position as given below:- Note : (i) The measurement of payment shall be made as per actual replacement of accessories, no extra cost will be paid to the contractor for T&P and tradesmen as required. (ii) Taking down the fitting as required for maintenance for cleaning or minor repairs such as tightening screw for loose connection, burnt wires , holders etc. and the cost of the same is deemed to be included in the rate quoted. (iii) The contractor shall depute one electrician and two helper on all working days in MES complaint cell for attending the complaint regarding the street light. All street light spares as given below shall be supply & replace as directed by Engineer-in-Charge . (iv) The components / parts like driver/ sensor /protector/ PVC insulated cable / acrylic cover for above fittings required to be replaced will be measured and paid separately under respective item of Sch ‘A’ as supply only. (v) Inventory of all defective parts required to be replaced will be recorded in a separate register alongwith pole No & location / area and type of light fittings before replacement duly signed by JE, Engineer-In-Charge & contractor and the same shall be produced as and when desired for verification.
Supply only electronic driver for 45/48 Watts LED street light fitting of any capacity complete all as specified.
Supply only electronic driver for 20-30 Watts LED street light fitting of any capacity complete all as specified.
Supply only surge protector of capacity 5 KV suitable for LED street light fitting of complete all as specified.
Material and labour for relaying the XLPE cable under ground aluminium conductor 1100 volts, in trenches or passing through pipe and connecting the cables with cable lugs, cable gland , nuts and bolts washer etc. and testing complete all as specified.
Supply and fixed in repairs powder coated Mild steel junction box of size 250 mm x 190 mm x 150 mm, out door type, weather proof, factory made out of CRCA sheet 2 mm thick with front openable hinged door having rubber lining, painting internally and externally with powder coated locking arrangements, 4 Nos copper bus bars , 100 Amps, mounted on porcelain insulator, glands and lugs etc. including one No MCB SP, 6 Amps, 10 kA, fixed on insulator and fixed on box in DIN rail , fix to pole with suitable size of FI clamps, nuts , bolts and washers complete with and including making good surface of existing surface and making connections complete all as specified.
Supplying and fixing in repair single run 2 core, 1.5 sqmm nominal cross sectional area multistranded copper conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated fixed to pole junction to light fitting complete all as specified.
Supply and fixed in repairs 20 mm nominal bore dia, low density polyethylene (LDPE) pipes of pressure rating 16 kgf/cm2 fixed to pole, any type including provision MS clamp of size 20mm x 3mm flat at interval of 1.5 m length complete all as specified and as directed
Supply and fixing in reapirs Time lite distribution board with in sheet steel enclouser of capacity 65 Amp comprising of 3 pole 65 Amp power contactor with coil voltage 415 Volt AC, MCB TPN 63 Amp 10 KA, Analog time switch and togle switch two way for manual and auto operation with and including internal connection with suitable size copper conductor wire complete all as specified and directed.
Supply and fixing in repair power contractor 50 amps 3 pole 415 Volts AC 50Hz,including connecting with existing system complete all as specified and directed.
Supply and fixed in repair of multifunction digital timer switch (10-60) Amps , 240 Volts , AC , Three phase complete all as specified and as directed.
Supply and fixed in repairs MCB TPN 40-63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Material and labour for removing old painted surface and apply two coats of exterior acrylic emulsion paint abrasion resistance, corrosion resistance, excellent adhesion with superior finish to PCC pole 9.00/9.50 mtr long including cross arms/street light bracket after preparation of existing painted surface including marking the strips of one feet each on pole with red and white exterior acrylic emulsion paint two coat upto 4 feet from the bottom of pole (Total 4 Nos strip of one feet each) and re-numbering of pole with approved size of letter (Example : CZ- 001) with synthetic enamel paint on black colour background and white colour lettering complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 63 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 100 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 160 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 200 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 250 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 400 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCB in panels etc. MCB, 63 Amps, TPN, 415 Volts, 10 kA, 50 Hz 'C" series complete all as specified and directed
Dismconnecing the existing cable from Panel/ Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint (Epoxy Type) suitable for LT XLPE cable of Size 3.5 /4 Core 25 to 50 Sqmm
Dismconnecing the existing cable from Panel/ Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint (Epoxy Type) suitable for LT XLPE cable of Size 3.5/4 Core 70 to 150 Sqmm
Material and labour for complete removal of existing paint of external steel surface by scrapping or heating of feeder pillar box / LT panel board and DBs of any size and applying two coats of spray painting of 1st quality over a coat of zinc chrome primer including applying filler coat for smooth surface and marking Sub-Station No, Feeder No, Feeding area, and Building with synthetic enamel paint as per existing complete all as specified
Supply and fixed in repairs powder coated mild steel junction box factory made of size 450 mm (B) x 300 mm (H) x 200 mm(D), made of CRCA sheet 2mm thickness, with front openable hinged door, locking arrangements with 4 Nos copper bus bars , 200 Amps, mounted on porcelain insulator, glands and lugs etc. and making connections complete all as specified.
Supply and fixed in repairs powder coated mild steel junction box factory made of size 350 mm (B) x 400 mm (H) x 200 mm(D) , made of CRCA sheet 2mm thickness, with front openable hinged door, locking arrangements with 4 Nos copper bus bars , 200 Amps, mounted on porcelain insulator, glands and lugs etc. and making connections complete all as specified.
Supplu and fixing of aluminium bus bar of size 400 mm X 40 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and directed.
Supply and fixing of aluminium bus bar of size 600 mm X 20 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and directed.
Supply, installation, testing and commissioning out door type cubical panel board of size (900 mm x 600 mm x 400 mm) overall outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system (Each door hinged with body at 4 places ) lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which included seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns , provided with suitable gasket to make it dust / vermin proof and general construction confirming to IS:8623/93. the TPN busbar shall be insulated with colour coaded heat shrinkable sleeve through out length of the busbar and shall be mounted on suitable size "F"class insulator at an interval not more than 250 mm. the cubicle incomer MCCB as well as outgoing shall have aluminium TPN extansion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. the extansion capacity not less than 300 mm long supported on suitable size "F"class insulator. all inter connection between the main busbar as well as outgoing feeder shall be carried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves, Danger Notice Board size as per IE Rule 1956 and including taking down of unserviceable panel board from site all as directed.
Supply, installation, testing and commissioning out door type cubical panel board of size (1500 mm (H) x 1000 mm (B) x 600 mm (D)) overall made out of 3.15 mm thick CRCA and MS angle section 50x50x6 mm CPRI approved degree of protection IP-55 and general construction confirming to IS; 13947 on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system (Each door hinged with body at 4 places ) lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which included seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns , provided with suitable gasket to make it dust / vermin proof and general construction confirming to IS:8623/93. the TPN busbar shall be insulated with colour coaded heat shrinkable sleeve through out length of the busbar and shall be mounted on suitable size "F"class insulator at an interval not more than 250 mm. the cubicle incomer MCCB as well as outgoing shall have aluminium TPN extansion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. the extansion capacity not less than 300 mm long supported on suitable size "F"class insulator. all inter connection between the main busbar as well as outgoing feeder shall be carried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves, Danger Notice Board size as per IE Rule 1956 including PCC foundation of size 0.80m x 0.60m x 1.05m depth (45cm below GL and 60 cm above GL in PCC 1:3:6 type C2 comprising of the following and including taking down of unserviceable panel board from site all as directed. (a) Incomming TPN acopper busbar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulators of non hygroscopic non combustable , all internal connection from main busbar to switch gear etc - 04 Nos (b) Outgoing TPN acopper busbar 300 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulators of non hygroscopic non combustable , all internal connection from main busbar to switch gear etc - 04 Nos (b) Incoming MCCB TPN 200 Amps 16 KA 415 volts, 50 Hz, FP withadjustable thermal magneti c release with Icu = 100 % Icu, neutral adjustmnet 100 % including all fixing accessories with both ends spreader links - 01 No NOTE: Rate of earthwork and PCC are deemed to be inclusive in the unit rate quoted against this item.
Supply and fixed in repairs powder coated Mild steel junction box of size 600 mm x 900 mm x 200 mm (depth) , indoor type, weather proof, factory made out of CRCA sheet 2.00 mm thick CPRI Approved with front openable hinged door having rubber lining, painting internally and externally with powder coated locking arrangements, to accomodated DBs, KWH Meter etc flush in wall including making good surface of existing surface omplete all as specified.
Supply & fixing in repairs LED indicating RED lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs LED indicating YELLOW lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs LED indicating BLUE lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs CT coil 100/5 Amps including necessary connection complete all as specified and directed.
Supply & fixing in repairs danger notice board / plate of size 20 cm x 15 cm, made out of 1.6 mm thickness mild sheet, vitreous enamelled white letters, figure and conventional skull and bones in Red colour and fixed with nuts and bolts for 1100 volts current complete all as specified and directed.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Permises around pole, around panel board along boundaries fencing, removing runnish material from work site and depositing where directed not exc. 100 meter from the starting point complete all as directed. Note : The item shall be operated maximum 2 (Two) times in the entire period of the Contract period and measurement will be taken every time independently for payment.
Supply and fixing in repairs Test point terminal block made of gun metal or Phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8 mm dia. 25 mm long hexagonal head screw all as specified and as directed.
Supply and fixed in repairs for 25 x 4 mm galvanized strip, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or fixed to poles or roof with saddle and screw complete all as specified and as directed.
Supply and fixed in repairs for 25 x 3 mm aluminium strip, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or fixed to poles or roof with saddle and screw complete all as specified and as directed.
Supply and fixing in repairs Air termination, single pointed aluminium rod 12 mm dia and 300 mm long fixed nwith 2 Nos suitable size of nut and bolt with washer all as specified and as directed.
Supply and fixed in repairs heavy duty porcelain?PVC insulator of size 65mm x 31 mm x 30 mm (height) to fixed aluminium/ galvanized strips on roof top, wall including PVC plug and gutties, screws complete all as specified.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 20 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for earthing complete with copper earth plate electrode 600 x 600 x 3.15mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using copper strip 20 x 3 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32mm x 6 mm thick as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 40mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Ms Singh Co
M/S East India Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .