Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bid | |
| 2 | L2₹20.9 L+₹2.0 L (10.3%)Rejected-Finance KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹22.9 L+₹4.0 L (21.1%)Rejected-Finance MOTHER TERESA ROAD ZOO TINIALI GUWAHATI 781024 | GUWAHATI | KAMRUP METRO | ASSAM | 781024 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹23.0 L+₹4.0 L (21.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹23.4 L+₹4.5 L (23.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
REPAIRS TO FANS GEYSERS AND SUMMER AND COOLING APPLIANCES AT MASIMPUR MIL STATION UNDER GE SILCHAR
2023_MES_581385_1
8769
Open Tender
Civil Works
Item Rate
180 days
MASIMPUR
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE Silchar
₹40,000
31 Mar 2023
16 Feb 2023
16 Mar 2023
16 Feb 2023
9 Mar 2023
3 Mar 2023
23 Feb 2023 - 27 Feb 2023
Amount
M&L for taking down AC 1.5/2TR capacity for required servicing, cleaning of cooling coil, air filters/plasma filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solutions, etc., checking serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches, knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed for the following type of AC units: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of taking down, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate
Window type AC units
Spli type AC units
S&F in repairs the following spare parts including necessary fittings as per sample and suitable for air conditioner 1.5/2T, split / window type units complete all as specified
Thermostat switch with regulating knob
Starting capacitor 80/100/120Mfd
Blower motor capacitor 8Mfd
Running capacitor 36Mfd
Running capacitor 50Mfd
Relay box / open type
Overload protector relay
Remote control for AC
Front grill suitable as per existing pattern including fixing screw
Air filter
Remote control PCB
Capillary charging
MS stand for split AC
Drain pipe 15mm dia 3m long
S&F in repairs blower motor assembly of air conditioner split type of any make, as per existing including necessary fittings viz. clamps, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs blower motor assembly of air conditioner window type of any make, as per existing including necessary fittings viz. clamps, nuts, bolts, etc. complete all as specified and as directed
Supply, installing, testing and commissioning of compressors of AC units, in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed of the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
S&F in repairs condensing coil assembly of air conditioner of any make, including necessary fittings viz. clamps, nuts, bolts, etc. and all required soldering, brazing, etc. complete all as specified and as directed
M&L for charging refrigerant gas F-22/R-134A in split type AC unit of capacity 1.52Ton including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for attending complaints to non-functional air condiotioner units at UVA Kumbhigaram and Masimpur Mil Station at any time and rectifying the complaint on urgent nature, by repairing, replacing unserviceable parts, electric wire, etc. testing on commissioning in satisfactory working conditions complete all as specified and as directed Notes: (a) Each complaint on successful completion shall be measured as one unit of work (b) Minor spares viz. nuts, bolts, wiring, etc. shall be included in he quoted rate. Major spare parts if replaced, gas charging and overall servicing if required shall be measured and paid separately under relevant items of the schedule (c) Contractor shall mobilize technicians to attend complaint and get the same rectified within 24hrs from the time of communication by any means. In the event of any failure a penalty @Rs. 500/hour shall be levied from subsequent due payments of the Contractor
M&L for disconnecting from mains, for servicing refrigerators / deep freezers including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches, knobs, leakage of gas, etc. and making the deep freezer / refrigerator to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate
230/285/286/310llitres
165/175/185litres
Supply only the following spare parts as per sample and suitable for refrigerators / deep freezers including necessary fittings complete all as specified and as directed
Relay open type (over load cum relay)
Overload protector
Cooling coil door with locking spring
Thermostat switch with regulating knob
Fan motor / evaburator
Fan blade
Chiller tray as per existing model
Frost free timer
Frost free cooling coil
Capillary charging
Thermal fuse
S&F company made new sealed compressor units for refrigerators 165 to 310litres, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed
S&F company made new sealed compressor units for deep freezers 200/300litres, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed
Notes for item Nos. 43 & 44: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
M&L for charging refrigerant gas F-22/R-134A in refrigerator units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for charging refrigerant gas F-22/R-134A in deep freezer units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed
S&F in repairs capillary tube and silica drier type strainer suitable for deep freezer 200/300/345/400litres capacity complete all as specified and as directed
S&F in repairs starting capacitor 4/6/8Mfd as per requirement at site suitable for deep freezer 200/300/345/400litres capacity complete all as specified and as directed Make: TESLA/EPCOS/SIEMENS/USHA
S&F in repairs over load protector relay suitable for deep freezer 200/300/362litres capacity complete all as specified and as directed Make: SHRIRAM/RENUTROL/DANFOSS
M&L for submain wring using proper colour coding with 4 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 6sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including non-metallic PVC casing capping 25mm wide, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed Notes: (i) 4 runs of 6sqmm main cable, 1 run of earth conductors and 1 run of PVC casing capping as per item shall be measured as one length (ii) Separate casing capping shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F single pole and neutral sheet metal enclosure powder coated with a two pin and earth plug and socket complete with and including 01No. MCB 20A SP and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs MCB, SP, 6 to 32A, 240V, 10kA complete all as specified and as directed
M&L for repairs to voltage stabilizer 4/5kVA of different make including replacement of worn out parts viz. volt meter, transformer, circuit plate, step-up, step-down relays, etc. and testing for proper functioning complete all as specified and as directed
S&F in repairs thermostat switch suitable for deep freezer 200/300/362litres capacity complete all as specified and as directed Make: RENUTROL/DANFOSS/INDFOSS
S&F in repairs relay open type suitable for deep freezer 200/300 /362litres capacity complete all as specified and as directed Make: SHRIRAM/RENUTROL
S&F in repairs fan motor suitable for deep freezer 200/300/362litres capacity complete all as specified and as directed
M&L for disconnecting from mains and taking down for servicing water coolers including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and making the water cooler to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate
150litres
60/120litres
40/80litres
S&F company made new sealed compressor units for water coolers of capacity 60/120litres, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
M&L for charging refrigerant gas F-22/R-134A in water cooler units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed
S&F in repairs blower motor assembly of water coolers of any make, as per existing including necessary fittings viz. clamps, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs condensing coil assembly of water coolers of any make, including necessary fittings viz. clamps, nuts, bolts, etc. and all required soldering, brazing, etc. complete all as specified and as directed
Supply only the following spare parts as per sample and suitable for water coolers including necessary fittings complete all as specified and as directed
Starting capacitor 60-80Mfd
Running capacitor 25Mfd
Thermostatic switch with regulating knob
Push cock, self closing chromium plated 15mm bore including nut and washer, etc.
PVC drain pipe 1m long including clamps
Float valve of gun metel, 15mm bore with ball
Over load protector relay
Running capacitor 36Mfd
Pencil strainer
Water Tap with 6'' concealed end pipe of size 15mm
Taking down carefully exhaust fans (with or without louvers), 225 to 450mm, any type, from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Note: Cost of replaced minor spares shall be deemed to be inclusive in the quoted rates
M&L for taking down carefully exhaust fans / bracket fans / wall mounted fans / pedestal fans (with or without louvers), 225 to 300mm, any type, from any position / location, rewinding with super enameled copper winding wire of same gauge, aprox weight 250-300gm/fan, including insulating, varnishing, baking, etc., cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Notes: (a) RPM test of fan with suitable tachometer will be done in the presence of Engineer-in-charge (b) All T&P will be provided by the Contractor and rate quoted shall be deemed to be inclusive of same
M&L for taking down carefully exhaust fans / bracket fans / wall mounted fans / pedestal fans (with or without louvers), 350 to 450mm, any type, from any position / location, rewinding with super enameled copper winding wire of same gauge, aprox weight 275-325gm/fan, including insulating, varnishing, baking, etc., cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Notes: (a) RPM test of fan with suitable tachometer will be done in the presence of Engineer-in-charge (b) All T&P will be provided by the Contractor and rate quoted shall be deemed to be inclusive of same
M&L for removing old worn out paint from exhaust fans / bracket fans / wall mounted fans / pedestal fans and blades of fans by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and suitable sized font) in body of fan and cleaning off the premises complete all as specified and as directed for the following capacities: Notes: (a) Painting of fans shall be done and returned within stipulated time of 3days (b) All T&P shall be provided by the Contractor and rate shall be deemed to be inclusive of same
upto 300mm sweep
350 to 450mm sweep
S&F fan blades (set of three) of existing size, type suitable for exhaust fan / wall mounting fan / pedestal fans, of approved design including taking off worn out / defective metallic blades and diposing off complete all as specified and as directed
225 to 300mm sweep
350 to 450mm sweep
M&L for taking down carefully ceiling fans, 1200/1400mm sweep from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Note: Replaced minor spares shall be meaured and paid under respective items herein
M&L for removing old worn out paint from fan and blades of ceiling fans, 1200/1400mm sweep, by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and suitable sized font) in body of fan and cleaning off the premises complete all as specified and as directed Notes: (a) Painting of fans shall be done and returned within stipulated time of 3days (b) All T&P shall be provided by the Contractor and rate shall be deemed to be inclusive of same
M&L for taking down carefully ceiling fans 1200mm sweep, from any position / location, strip opening and rewinding with super enameled copper winding wire of same gauge, aprox weight 275-325gm/fan, including insulating, varnishing, baking, etc., cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Notes: (a) RPM test of fan with suitable tachometer will be done in the presence of Engineer-in-charge (b) All T&P will be provided by the Contractor and rate quoted shall be deemed to be inclusive of same
M&L for taking down carefully ceiling fans 1400mm sweep, from any position / location, strip opening and rewinding with super enameled copper winding wire of same gauge, aprox weight 300-350gm/fan, including insulating, varnishing, baking, etc., cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Notes: (a) RPM test of fan with suitable tachometer will be done in the presence of Engineer-in-charge (b) All T&P will be provided by the Contractor and rate quoted shall be deemed to be inclusive of same
S&F ball bearings suitable for ceiling fans complete all as specified and as directed of the following sizes: Make: SKF or technocommercially equivalent make of NBC/URB
S&F gun metal bush suitable for ceiling fans of any size/make including taking off existing worn out/defectivere bush and re-assembling and testing on completion complete all as specified and as directed
S&F condenser 220V including including taking off existing worn out/defectivere condensor and making connections etc. complete all as specified and as directed of the following capacities: Make: USHA or technocommercially equivalent make of BAJAJ/ HAVELLS
S&F electronic fan regulator, stepped type (5 steps), 120W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F canopy (set of 2 pieces) suitable for ceiling fans (of any size/make), approved design, pattern and colour, with screws complete all as specified and as directed
S&F plastic bottom cover suitable for ceiling fans (of any size/make), approved design, pattern and colour, with all necessary fixing arrangements complete all as specified and as directed
M&L for taking down carefully geysers of any capacity any make after disconnecting electric & water connections for carrying out repairs by replacing worn out / damaged parts / components, refixing the same after carrying out necessary repairs to original place and re-connecting electric & water supply lines complete all as specified and as directed Note: Replaced parts / components will be measured under respective items hereunder
S&F water heater inner tank, glass lined stainless steel, suitable for geysers, of existing make including taking down of geysers (if required) by disconnecting connections, taking out old unserviceable inner tank and disposing off and reconnecting connections complete all as specified and as directed suitable for the following capacities of geysers:
25litres
50litres
S&F in repairs heating element 1.5kW rating as required at site including rubber washers (ISI marked), triangular/round shape with pocket for thermostat complete all as specified and as directed
S&F in repairs heating element 2kW rating as required at site including rubber washers (ISI marked), triangular/round shape with pocket for thermostat complete all as specified and as directed
S&F in repairs thermostat, ISI marked suitable for the geysers 25 to 50litres capacity, 20A, 240V AC, adjustable type, 210mm long as required at site complete all as specified and as directed
S&F in repairs thermostat, ISI marked suitable for the geysers 25 to 50litres capacity, 20A, 240V AC, fixed type, 300mm long, set at 90+6o as required at site complete all as specified and as directed
S&F in repairs indicating bulb of geysers complete all as specified and as directed
S&F in repairs PVC insulated copper (flexible) conductor 2.5sqmm 3 core 1100V grade and connecting up complete all as specified and as directed
S&F in repairs 3 pin plug top 15A, 240VAC, heavy duty, ISI marked suitable for 15A socket outlet complete all as specified and as directed
S&F in repairs 3 pin plug top 5A, 240VAC, heavy duty, ISI marked suitable for 5A socket outlet complete all as specified and as directed
S&F in repairs apparatus plate bottom cover in two halves made out of GI sheet duly painted with two coats of synthetic enamel paint (of approved tint) suitable for geysers 25/35/50litres capacity complete all as specified and as directed
S&F in repairs clamp for apparatus plate suitable for geyser as per sample complete all as specified and as directed
S&F in repairs brass chromium plated water pipe with brass nut and washers of good quality, 45cm long including taking down of old unserviceable hot & cold water copper / PVC flexible pipe connections from geysers and connecting up complete all as specified and as directed
M&L for preparing surfaces of geysers 25/50 litres capacity by rubbing with emery paper/removing rust, etc. and painting with two coats of white synthetic enamel paint and writing MES No. in black markers in ligible font and refixing the same to original place and re-connecting electric and water supply lines complete all as specified and as directed
M/S SANJIB DEB
M/S LUIT CONSTRUCTION
M/S PIJUSH BHATTACHARJEE
M/S TAPAN KUMAR RAY
m/s builders and suppliers
M/S M P Sharma
M/S Manik Lal Gupta
M/S R A ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .