Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical ROOM NO 1 SADAR BAZAR CHAIBASA SADAR BAZAR WEST SINGHBHUM JHARKHAND 833201 | WEST SINGHBHUM | JHARKHAND | 833201 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical JAMSHEPUR | PAKUR | JHARKHAND | 816104 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹75.1 L
EMD Value
₹1.5 L
Closing Date
17 Jun 2023, 6:30 pmClosed
Nodal Officer
e-Procurement Cell, Office of the Superintending Engineer, Building Construction Department, Chotanagpur Circle, Line Tank Road, Ranchi.
Proposed Construction of Community Hall in Campus of OLD DC Office Near Sadar Civil SDO Office at Chaibasa in the Dist. of West Singhbhum for the Year 2023-24
2023_BCD_72423_1
BCD/SECNC/15/Building Div. Chaibasa/2023-24
Open Tender
Civil Works - Buildings
Works
270 days
Chaibasa
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE, BCD, Building Division, Chaibasa
₹1.5 L
Yes
8 Jul 2023
12 Jun 2023
19 Jun 2023
12 Jun 2023
17 Jun 2023
12 Jun 2023
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.
Extra for earthwork in hard soil as per specification and direction of E/I. (vide classification of soil item-B)
Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
Earth filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 1.10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 1.10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Centering and shuttering including strutting, propping etc. and removal of form for :Stair
Providing and mixing liquid integral water proffing compound in conctrete of plaster as manufacturer specification and as per direction of engineer in charge. Brand. Sika plastocrate plus, MYK proff WP 10, Fosroc-Conplast x 4211C, Dr.Fixit, Pidiproff LW+ or Equivalent
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing TMT reinforcement of following dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
8 mm dia (20 % of total reinforcement)
10mm dia (20 %of total reinforcement)
12 mm dia (25 %of total reinforcement)
16 mm dia (25 %of total reinforcement)
20/25 mm dia (10%of total reinforcement)
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
Making 6x6mm grooves in plaster surface over walls truely horizontal or verical as specified at regular intervals, at all heights including cleaning, finishing scaffoding and curing with all leads and lifts of water all complete as per building specification and direction of E/l.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less then 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement:4 Coarse sand0, jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with wite cement and matching pigments etc, complete Size of tiles 600 x 600 mm.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:Profile C Fixing with adjustable lugs with split end tail to each jamb
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 35mm thick solid core type decorative Double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer- n-charge, manufacturer’s specification & drawing. 30 mm thick pre laminated PVC door shutters
Supplying, fitting & fixing M.S. Grill made of 20x6mm flat as per approved design and drawing aproperly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion - Powder coated aluminium (minimum thickness of powdercoating 50 micron)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
Prividing French spirit polishing over new wooden surface to give desired texture and gloss with apporoved make and shade of ready mixed french polish including preparing the surface sfter cleaning removing dirt
Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.
Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
Water proofing for old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flextble material brush, roller or spray for water proofing coating per manufacturer Specifications with following steps :-(a)surface preparation .-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing (loose paint / coating, and cement laitance by cleaning with compressed air water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage leakage. On identification of seepage cement grouting to be done with non shrink expanding admixture of Sika India Pvt.L.td.) MYK Schomberg / Dr Fixiti/ Fosroc or equivallent. Providing and reparing of all Corner and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150Mrn X 150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic pc?' lymer of Sika/ Fosroc/MYK Schomberg/Dr 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent.,Befor 'Chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar-including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)lst Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitiot.is material on surface saturated dry roof and inside wall of Parapet.Wall upto 600 mm by brush or roller . After 1st coat of application , 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat shOUld be applied @1.50 kg/Sqmt/coat. For the purpose of measurer-11609-1'e entire treated surface will be measured." (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified read to use, flexible cementtiOus material right angle to the 1st. coat over the glass fibre laid surface: 2nd coat-,should be applied @ 0.7 Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:- Sika Topseal 109hi / Fosroc Brushbond RFXI Dr. Fixit Pidiffin 2K / MYK Aquafin TG . Product Performance - Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder - Density 1.6 kg/I (mixed density) at +27°C Tensile Strength -2 Nimm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Siren th -2 f\l/mm2 concrete failure Accordin' to ISO4624) Slant-Shear Bond Strength -4 Nimm2 (According to FIP 5.15) Elongation at Break -35% Without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) )Protection of treated surface with PCG :- The treated surface should be covered with 25mm/50mm F'CC of M-20 grade (1.1.5:3). with proper slope ( 1:120) towards the rain outlets in alternate panels of 2 mt x 2 mt keeping 6 rnm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 co of 100 ml per bag of of cement to be added in the screed concreie(paid separately.for this items).All corners shall be chamfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed prorSeqswith ridti:corict'ete and the peripheral mouth to be sealed with,moisture insensitive epoxy putty of. Sika India .Pvt.Ltd. / MYK Schornbefg /Dr Fixit/Fosroc .For the purpose of measurement the entire treated surface will be measured." (e)Groove of PCC surface should be filled with POlysulphide Sealant.(Paid Separately). Be d - Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc . Warranty for five years.
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia
Providing & fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion
Bend 110 mm
Shoe 110 mm
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing 250 mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mmdia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.
Carriage of Material
Sand 8 km
Sand 8 km
Chips (1K+7P)
Brick (1K+7P)
Fly Ash Brick
Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable
Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.
Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
5/6 A switch
3 pin 5/6 A socket outlet
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Power Plug Wiring in PVC conduit (2x4 sq. mm): Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2x1.5 Sqmm + 1x1.5 sqmm earth wire for separate 3 pin 5A sockets
2x2.5 Sqmm + 1x2.5 sqmm earth wire for switch board
Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/ recess including cutting the wall and making good the same as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Bell push
S/F Modular Boxes, base & cover plate: Supplying and fixing following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 module (75 mm x 75 mm)
S/F TP MCB DB: Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR).
6 ways (4+18 ways) double door
S/F 'C' series SP MCB: Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.
6/32A Single Pole
S/F Ceiling Rose: Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required.
S/F Modular type electronic fan regulator: Supplying and fixing two module, stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
Supply of Metal Exhaust Fan 12"(300mm): Supply of 12"(300mm), 230V AC metal exhaust fan in the existing opening.
ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
LED tube with Batten 20W: Supplying and fixing of wall mounted LED 20W tube light suitable for 230V, single phase supply voltage, with all accessorieslike batten and electronic driver and accessories as required.
Surface mounted round Downlightes 6W/7W LED: Supply and installation of round shapeed surface mounting downlight for common areas.
LED Flood Light 100W:Supply installation Testing and Commissioning of LED flood lighting( 100W ) luminarie with prssure die cast housing and toughened glass cover (IP-66 protection in existing pole/ pipe for supply voltage 100-270 volts AC, 50Hz. Luminarie shall confirming to IS:10322 part-5/ section -5 and shall be conecessary accessories as per required.
Bulk head 10 LED Fitting: Supply and fixing of 10W LED, surface mounted bulk head PVE water proof housing for indoor/ outdoor.
LED Bulb 10W : Supplying and fixing of LED 10W bulb and accessories as required.
Copper Earth Plate Elecrode:- Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but with charcoal or cock and salt) complete etc. as required. Lightning Conductors=1 no + Panel=1 no).
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm
Providing and fixing 25 mm X 5 mm G.I. strip on surface or inbrecess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and Fixing Lightning Conductor Finial : P/F of lighting conductor finial, made of 25mm dia 300mm long GI tube, having single prong at top, with 85mm dia 6mm thick GI base plate including holes etc. complete as required.
GI lightning conductor tape in horizontal run - Providing and fixing of GI tape 20mm X3mm thick on parapet or surface of wall for lighting conductor etc complete as required.
GI lightning conductor tape in Vertical run - Providing and fixing of GI tape 20mm X3mm thick on parapet or surface of wall for lighting conductor etc complete as required.
MV Cable:- Supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS:7098 armoured, served, sheathed, 1100V grade with Termination and Laying of cable.
3.5CX 25 sq. mm armoured AL Cable.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable not exceeding 35 sq mm of 1.1 KV grade of direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3.5Cx 25 sq.mm
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., "p" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. 580mm. long - with 10 litre low level PVC cistern
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With "P" trap (b)10 lit. low level P.V.C. cistern
Urinal
Providing and fixing C.P. brass bib cock of approved conforming to IS 8931 : 15 mm nominal bore
Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 690gms.:15 mm nominal bore.
Providing and fixing PTMT Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, Weighing not less then 106 gms.
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
Providing and fixing C.P. extentsion Nipples 15mm size with 12” BSP threads, 70mm length and 30 mm bredth and weight not less than 18gms
Providing and fixing Mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing.Circular shape 450 mm dia
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :Falt back wash basin size 630X450 mm with a single 15mm C. P. pillar tap.
Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length
Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the wall etc..
15mm dia
20mm dia
25mm dia
32 mm dia.
40mm dia
Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe
Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
Providing and placing on terrace (at all floo levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and marking necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing c.p. towel rail complite with brackets fixed to wooden cleats with c.p.brass screws with concealed fitting arangement of approved qualite colour and make.(Mark or equipment)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 178 mm
Providing and fixing Sink Cock with Swinging casted spout
Providing and fixing PTMT/ C.P. swivelling shower,15mm nominal size, 95mm long, 65mm dia. of approved quality, color & make weighing not less than 40 gms with approximate 80 holes of 1.2 mm dia.
provding and laying of 75 mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.(SUPREME S.W.R.)
provding and laying of 110 mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.(SUPREME S.W.R.)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler 75 mm
Coupler 110 mm each
Single pushfit Coupler 75 mm
Single pushfit Coupler 110 mm
Single tee with door 75x75x75 mm
Single tee with door 110x110x110 mm
Single tee without door 75x75x75 mm
Single tee without doo 110x110x110 mm
Bend 87.5° 75 mm bend
Bend 87.5° 110 mm bend
Shoe (Plain) 75 mm Shoe each
Shoe (Plain) 110 mm Shoe
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as sper building specification and direction of E/I.
Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 1.5 mm. cement punning including curing carrage of water withall leads and lifts as per building specification and direction of E/I
Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M upto 150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supplying Full automatic star selta starter to operate induction motor working on 415v 3phase 50hz with no coil. Over load element , On _OFF push buttom with necessary materials and connection to Supply etc complete starter with original sheel steel encloser as per 3914. F.A.S.D starter upto 5 H.P
3 core PVC insulated PVC sheathed copper conductor flat submersible cable. Supplying , Flat flexible submersible cable with ,copper conductor , PVC insulated and PVC sheathed as IS:7098 3 Core 4 Sq mm. Copper wire
Supply fitting and fixing GI pipe 50 mm Dia (TATA or equivalent make) Medium Quaility as per IS:1239 ( part 01 ) 2004
Add 18 % GST (in Basic Rate must fill 12)
Add 1% Labour Cess (in Basic Rate must fill 1)
R K TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .