Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAdmitted-Finance 4 1309 NEW SIR SYED NAGAR ALIGARH ALIGARH UTTAR PRADESH 202002 | ALIGARH | UTTAR PRADESH | 202002 | L1 | Admitted-Finance | |
| 2 | L2₹2.0 L+₹6,300 (3.26%)Admitted-Finance 90 A 2ND FLOOR MAIN ROAD AMRIT PURI B REGD EAST OF KAILASH SOUTH DELHI 110065 | DELHI | SOUTH DELHI | DELHI | 110065 | L2 | Admitted-Finance | |
| 3 | L3₹2.2 L+₹26,500 (13.7%)Admitted-Finance 0 LUCKY HOUSE BIJNOR ROAD RADHEY VIHAR COLONY VILLAGE TOWN AURANGABAD JAGIR CITY LUCKNOW LUCKNOW UTTAR PRADESH 226002 INDIA | LUCKNOW | UTTAR PRADESH | 226002 | L3 | Admitted-Finance | |
| 4 | L4₹2.4 L+₹48,500 (25.1%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | Rejected-Technical | - | Rejected-Technical Technical Bid Reject |
| Sl No | Description | Qty | Unit | Nevco Engineers Pvt Ltd L2 | LUCKY ELECTRICALS AND AUTOMATION L3 | Engineering and Environmental Solutions Private Limited L1 | Sarvnidhesh Enviro and Chemico Solutions L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installtion & commossioning of SPM analyzer with TUV. As per specifications, The system should have the below features as desired by CPCB.
A) The SPM analyzer should have continuous quality check for Zero and Spa point, prferably without human intervention to ensure continuous daya validity and credibility. (Please refer guidelines for Continuous Emission Monitoring System July 2017 page 8/100)
b) The system should have feature of automatic range setup.
c) The system does not required manual adjustment and should operate without any human intervention.
d) The system should have autotic drift compensation.
e) The system doen not have optical windows to be cleaned.
f) The system should not required any alignment for smooth operation.
g) The system doen not have any effect of vibrations on the system accuracy and readings.
h) The system should have TUV with QAL (EN15267 parts 1 to 3) with appropriate certification range as per CPCB guidelines.
Measurement principle: Inductive Electrification
Measurement objects: Solid particles in a gas Flow
Particle size : 0.3 um or larger
Measurement range: Approx 0.1 mg/m3 to 1 Kg/m3
Probe length: As per requirement (Standard 500,750,1000,1500,2000 mm)
Probe dia: 10 mm | 1 | - | 1,99,800 ₹1,99,800 | 2,20,000 ₹2,20,000 | 1,93,500 ₹1,93,500 Lowest | 2,42,000 ₹2,42,000 |
| 1.01 | Max temperature: Upto 300 Degree C. (Optional upto 700 degre C)
Max Pressure: 3 bar
Gas velocity: Min 4 m/s
Response Time: Less than 1 second
Self Zero span check: Yes
Signal Averaging: Adjustable 0-300 seond
Output signals: Isolated 4-20 mA Serial communicaiton RS-485 Modbus
- Two SPDT relays:5A-24 VAC/DC
Ambient Temperature: 20 to +60 degree C
Humidity: 95% RH (non- condensing)
Vibration: 5 m/s2 or less
Probe: SS316 L
Insulation of probe: Peek
Enclosure: Aluminmb Alloy
Power Supply: 230 VAC, 15 VAC, 24 VDC
Power consumption: 3 W
Protection: IP65
Certification: TUV with QAL1 | 1 | Each | - | - | - | - |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
19 Jul 2025, 5:00 pmClosed
General manager
The Kisan Sahkari Chini Mills ltd Nadehi
Supply and Installation and Commissioning of SPM Analyzer
2025_KCMN4_85343_1
PS/107A/2025-26
Open Tender
Miscellaneous Works
Item Wise
21 days
Nadehi
Please refer Tender documents.
2 documents required · 2 mandatory
₹354
GM (KSCML)
₹10,000
28 Aug 2025
5 Jul 2025
21 Jul 2025
5 Jul 2025
19 Jul 2025
5 Jul 2025
Supply, Installtion & commossioning of SPM analyzer with TUV. As per specifications, The system should have the below features as desired by CPCB. A) The SPM analyzer should have continuous quality check for Zero and Spa point, prferably without human intervention to ensure continuous daya validity and credibility. (Please refer guidelines for Continuous Emission Monitoring System July 2017 page 8/100) b) The system should have feature of automatic range setup. c) The system does not required manual adjustment and should operate without any human intervention. d) The system should have autotic drift compensation. e) The system doen not have optical windows to be cleaned. f) The system should not required any alignment for smooth operation. g) The system doen not have any effect of vibrations on the system accuracy and readings. h) The system should have TUV with QAL (EN15267 parts 1 to 3) with appropriate certification range as per CPCB guidelines. Measurement principle: Inductive Electrification Measurement objects: Solid particles in a gas Flow Particle size : 0.3 um or larger Measurement range: Approx 0.1 mg/m3 to 1 Kg/m3 Probe length: As per requirement (Standard 500,750,1000,1500,2000 mm) Probe dia: 10 mm
Max temperature: Upto 300 Degree C. (Optional upto 700 degre C) Max Pressure: 3 bar Gas velocity: Min 4 m/s Response Time: Less than 1 second Self Zero span check: Yes Signal Averaging: Adjustable 0-300 seond Output signals: Isolated 4-20 mA Serial communicaiton RS-485 Modbus - Two SPDT relays:5A-24 VAC/DC Ambient Temperature: 20 to +60 degree C Humidity: 95% RH (non- condensing) Vibration: 5 m/s2 or less Probe: SS316 L Insulation of probe: Peek Enclosure: Aluminmb Alloy Power Supply: 230 VAC, 15 VAC, 24 VDC Power consumption: 3 W Protection: IP65 Certification: TUV with QAL1
Nevco Engineers Pvt Ltd (BID ID -390778)
LUCKY ELECTRICALS AND AUTOMATION (BID ID -390953)
Sarvnidhesh Enviro and Chemico Solutions (BID ID -390942)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .